You are on page 1of 2

Pressure Drop First Pass

Method 1

Method 2

fL 1.5 N b G
v 5
P =
+
+
Di 12 12 10
Capacity
#elements
f
L
Di
As
Nb
v
G
P

P = 3.36 x10 6 fW 2 Le

75.000,00 Lb/hr
9
0,0208
78,7 ft.
1,67 in.
0,13690013 ft2
4,79
0,7413 ft3/lb
547.844,63 Lb/h-ft2
33,4708707 Psi

37,7194277 Psi

v
d i5

Pressure Drop Second Pass


Method 1

Method 2

fL 1.5 N b G
v 5
P =
+
+
Di 12 12 10
Capacity
#elements
f
L
Di
As
Nb
v
G
P

P = 3.36 x10

75.000,00 Lb/hr
9
0,0208
78,7 ft.
1,67 in.

47,1887188 Psi

P(tot)

84,9081464 Psi

0,13690013 ft2
4,79
0,9274 ft3/lb
547.844,63 Lb/h-ft2
41,8735809 Psi

Total Pressure Drop


P(tot)

75,3444516 Psi

v
fW Le 5
di
2

You might also like