You are on page 1of 5

ZND140-AMT-Td-0001-Rev.

FAST PLANETS Co Ltd.,


ENGINEERING DEPARTMENT
P.0. BOX : 34620 RIYADH - 11478

Project: CI&3G Project 2011

COMPARISON OF ANTENNA LOADING FOR 30.0m TEP 6 TOWER

Main Site No.: ZND332 Far end Site No.: ZND140


EXISTING + PROPOSED LOADING CONDITION FOR BASIC WIND SPEED @ 39 m/s & BASIC WIND SPEED @ 35 m/s

ZND140-AMT-Td-0001 Rev. A TABLE OF CONTENTS TITLE No. COVER PAGE TABLE OF CONTENTS SCOPE ATTACHED CALCULATIONS
(ORIGINAL DESIGNED ANTENNA LOADS vs ACTUAL & EXISTING + PROPOSED ANTENNA LOADS)

PAGE 1 2 3 4-5 6

CONCLUSION

Analyzed by: Approved by: _____________ J.B.Vasquez Telecom Engr. Manager

Checked by:

______________ J.A.hasson Structural Engr.

_______________ M.A. Aqeel Projects

Page 2

ZND140-AMT-Td-0001 Rev. A SCOPE: The existing tower at this site is a 30.0m Type II tower. The scope of study is, Comparison of the existing Antennas with the original designed Antennas of the tower. Please see Attached Calculations showing Original Designed Antenna Loads vs Actual & Existing + Proposed Antenna Loads for reference. All calculations comply with the provisions of TIA-EIA-222-F.

Page 3

ZND140-AMT-Td-0001 Rev. A

ATTACHED CALCULATIONS

Conclusion: By comparing the existing & proposed antennas with the Original Designed antennas as shown in the above tables, it is concluded that under a wind speed
Page 4

ZND140-AMT-Td-0001 Rev. A of 39 m/s, the combined load due to existing & proposed antennas is GREATER than the Original Designed antenna loads. However, under a wind speed of 35 m/s, it is concluded that the combined load due to existing & proposed antennas is LESSER than the Original Designed antenna loads. Therefore, the existing tower can safely support the combined existing & proposed antenna loading under a wind speed of 35 m/s only.

Page 5