Professional Documents
Culture Documents
Nondestructive Testing
PROBE SELECTION
SONSOCAN Straight Beam Probes
The ergonomic straight beam probes of the SONOSCAN series for nondestructive material
testing comply with the European standard DIN EN 12668-2. They are used to check metals,
plastics and ceramic materials for discontinuities, such as cracks, inclusions, blowholes and
other material flaws. The pulse echo and dual element probes Made in Germany are powerful,
robust ultrasonic transducers, which are compatible to the new ultrasonic flaw detector
SONOSCREEN ST10 and common mobile ultrasonic test equipment.
Advantages
Excellent acoustic characteristics
Unique ergonomics and fatigue-proof, handy usage
Suitable for DGS evaluation
We offer our precise ultrasonic probes with different frequencies and transducer sizes. Choose
the most suitable probe for your application, depending on material characteristics, thickness
and geometry of the work piece. In addition to standard probes, customer specific solutions can be
realized.
25
The SONOSCAN series angle beam probes for non-destructive material testing detect even
smallest discontinuities and quality failures such as cracks, incomplete fusions, blowholes or
inclusions. All SONOSCAN probes are compatible with the new flaw detector SONOSCREEN
ST10 and other common ultrasonic testing equipment. During the testing process, the transducer
transmits ultrasonic waves through an integrated wedge into the test object. Typical incident
angles are 45, 60 and 70. There exist several construction types and sizes for various
applications. By individual grinding, the probes can be adapted to differently curved surfaces.
Their unique and ergonomic design allows comfortable and fatigue proof testing.
Advantages
Excellent acoustic characteristics
EN 12668-2 certified
Realization of customized solutions possible
The high precision SONOSCAN probes are manufactured in three different construction types.
They can be selected according to their angle, frequency, transducer size and environmental
conditions.
Probe Selection
Probe Selection
Frequency
Transducer
Order number
PL2 EN
PL4 EN
PS2 EN
PS4 EN
2 MHz
4 MHz
2 MHz
4 MHz
24 mm
24 mm
10 mm
10 mm
100 02 0002
100 02 0003
100 02 0004
100 02 0005
Page
6
8
10
12
Frequency
Transducer
Order number
HS4 EN
4 MHz
10 mm
100 02 0007
Page
14
Connection: LEMO 00
Frequency
Transducer
Order number
TL2 EN
TL4 EN
TS2 EN
TS4 EN
2 MHz
4 MHz
2 MHz
4 MHz
7 x 18 mm
6 x 20 mm
11/2 mm
3.5 x 10 mm
100 02 0008
100 02 0009
100 02 0010
100 02 0011
Page
16
18
20
22
Connections: 2 x LEMO 00
Probe certificate according to DIN EN 12668-2 included
Optional accessories
Connection cable
Couplant
Calibration blocks
Probe Selection
SONOSCAN PL2 EN
Pulse Echo Probe for Contact Technique
Transducer dimensions: 24 mm
Centre frequency:
2 MHz
Coupling membrane:
Vulkollan
Technical Data
Reference
Tolerance
Dimensions
1.7
0.5
Centre frequency *
0.2
MHz
Relative bandwidth @ -6 dB *
46
-33
dB
24
0.1
mm
45
mm
Focal diameter
2.9
0.3
mm
Focal length @ -6 dB
70
14
mm
Divergence angle
3.7
0.4
Degree
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Piezoelectric ceramics
Electrical connection
LEMO 00
Housing material
Epoxy filled
Wear allowance
0.4 mm
Working temperature
Weight
208 g
Order number
100 02 0002
* measured on 40 mm polystyrene;
All other values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
Test Conditions
Test apparatus
SONOSCREEN ST10
Voltage
100 V
Damping
50
Pulse width
250 ns
Probe Selection
DGS-Diagram
Noise level
Pulse Shape
Spectrum
Electrical Impedance
Probe Selection
SONOSCAN PL4 EN
Pulse Echo Probe for Contact Technique
Transducer dimensions: 24 mm
Centre frequency:
4 MHz
Coupling membrane:
Vulkollan
Technical Data
Reference
Tolerance
Dimensions
1.6
0.5
Centre frequency *
0.4
MHz
Relative bandwidth @ -6 dB *
35
-41
dB
24
0.1
mm
88
mm
Focal diameter
2.9
0.3
mm
Focal length @ -6 dB
120
24
mm
Divergence angle
1.9
0.5
Degree
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Piezoelectric ceramics
Electrical connection
LEMO 00
Housing material
Epoxy filled
Wear allowance
0.2 mm
Working temperature
Weight
208 g
Order number
100 02 0003
* measured on 40 mm polystyrene;
All other values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
Test Conditions
Test apparatus
SONOSCREEN ST10
Voltage
100 V
Damping
50
Pulse width
125 ns
Probe Selection
DGS-Diagram
Noise level
Pulse Shape
Spectrum
Electrical Impedance
Probe Selection
SONOSCAN PS2 EN
Pulse Echo Probe for Contact Technique
Transducer dimensions: 10 mm
Centre frequency:
2 MHz
Coupling membrane:
Vulkollan
Technical Data
Reference
Tolerance
Dimensions
2.3
0.4
Centre frequency *
0.2
MHz
Relative bandwidth @ -6 dB *
36
-35
dB
10
0.05
mm
1.5
mm
Focal diameter
1.2
0.1
mm
Focal length @ -6 dB
10
mm
Divergence angle
Degree
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Near field length
Piezoelectric ceramics
Electrical connection
LEMO 00
Housing material
Epoxy filled
Wear allowance
0.4 mm
Working temperature
Weight
51 g
Order number
100 02 0004
* measured on 40 mm polystyrene;
All other values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
Test Conditions
Test apparatus
Energy
low
Damping
400
Filter
STD
10
Probe Selection
DGS-Diagram
Noise level
Pulse Shape
Spectrum
Electrical Impedance
11
Probe Selection
SONOSCAN PS4 EN
Pulse Echo Probe for Contact Technique
Transducer dimensions: 10 mm
Centre frequency:
4 MHz
Coupling membrane:
Vulkollan
Technical Data
Reference
Tolerance
Dimensions
0.9
0.2
Centre frequency *
0.4
MHz
Relative bandwidth @ -6 dB *
47
-35
dB
Transducer dimensions
10
0.05
mm
15.6
mm
Focal diameter
1.2
0.1
mm
Focal length @ -6 dB
28
5.5
mm
Divergence angle
4.4
0.4
Degree
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Piezoelectric ceramics
Electrical connection
LEMO 00
Housing material
Epoxy filled
Wear allowance
0.2 mm
Working temperature
Weight
51 g
Order number
100 02 0005
* measured on 40 mm polystyrene;
All other values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
Test Conditions
Test apparatus
Energy
high
Damping
50
Filter
STD
12
Probe Selection
DGS-Diagram
Noise level
Pulse Shape
Spectrum
Electrical Impedance
13
Probe Selection
SONOSCAN HS4 EN
Pulse Echo Probe for Contact Technique
Transducer dimensions: 10 mm
Centre frequency:
4 MHz
Protective layer:
Aluminum oxide
Technical Data
Reference
Tolerance
Dimensions
0.7
0.2
Centre frequency
0.4
MHz
Relative bandwidth @ -6 dB
58
10
-33
dB
Transducer dimensions
10
0.05
mm
15.6
mm
Focal diameter
1.2
0.1
mm
Focal length @ -6 dB
26
mm
Divergence angle
4.4
0.4
Degree
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Piezoelectric ceramics
Electrical connection
LEMO 00
Housing material
Aluminum oxide
Working temperature
Weight
55 g
Order number
100 02 0007
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
Test Conditions
Test apparatus
Energy
low
Damping
50
Filter
STD
14
Probe Selection
DGS-Diagram
Noise level
Pulse Shape
Spectrum
Electrical Impedance
15
Probe Selection
SONOSCAN TL2 EN
Dual Element Probe for Contact Technique
Transducer dimensions: 7 mm x 18 mm
Centre frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
1.7
0.3
Centre frequency
0.2
MHz
Relative bandwidth @ -6 dB
75
-43
dB
>42
dB
7 x 18
0.05
mm2
Focal distance
15
mm
3.5
0.7
mm
6.5
1.3
mm
Focal length @ -6 dB
40
mm
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Piezoelectric ceramics
Electrical connection
2 x LEMO 00
Housing material
Delay material
Plastics
Wear allowance
3 mm
Working temperature
Weight
195 g
Order number
100 02 0008
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C
Test conditions
Test apparatus
SONOSCREEN ST10
Voltage
100 V
Damping
400
Pulse width
250 ns
16
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
17
Probe Selection
SONOSCAN TL4 EN
Dual Element Probe for Contact Technique
Transducer dimensions: 6 mm x 20 mm
Centre frequency:
4 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
0.8
0.3
Centre frequency
0.4
MHz
Relative bandwidth @ -6 dB
65
-42
dB
>45
dB
6 x 20
0.05
mm2
Focal distance
12
2.4
mm
2.5
0.5
mm
1.4
mm
Focal length @ -6 dB
35
mm
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Piezoelectric ceramics
Electrical connection
2 x LEMO 00
Housing material
Delay material
Plastics
Wear allowance
3 mm
Working temperature
Weight
195 g
Order number
100 02 0009
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C
Test conditions
Test apparatus
SONOSCREEN ST10
Voltage
100 V
Damping
400
Pulse width
125 ns
18
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
19
Probe Selection
SONOSCAN TS2 EN
Dual Element Probe for Contact Technique
Transducer dimensions: 11 / 2 mm
Centre frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
1.6
0.3
Centre frequency
0.2
MHz
Relative bandwidth @ -6 dB
62
-49
dB
>35
dB
11 / 2
0.05
mm
Focal distance
1.6
mm
0.4
mm
2.5
0.5
mm
Focal length @ -6 dB
20
mm
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Piezoelectric ceramics
Electrical connection
2 x LEMO 00
Housing material
Delay material
Plastics
Wear allowance
3 mm
Working temperature
Weight
57 g
Order number
100 02 0010
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C
Test conditions
Test apparatus
SONOSCREEN ST10
Voltage
100 V
Damping
400
Pulse width
250 ns
20
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
21
Probe Selection
SONOSCAN TS4 EN
Dual Element Probe for Contact Technique
4 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
0.8
0.3
Centre frequency
0.4
MHz
Relative bandwidth @ -6 dB
62
-45
dB
>40
dB
3.5 x 10
0.05
mm2
Focal distance
12
2.4
mm
2.2
0.4
mm
3.5
0.7
mm
Focal length @ -6 dB
27
mm
Squint angle
Degree
Offset
<1
mm
<0.05
mm
Transducer dimensions
Piezoelectric ceramics
Electrical connection
2 x LEMO 00
Housing material
Delay material
Plastics
Wear allowance
3 mm
Working temperature
Weight
57 g
Order number
100 02 0011
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C
Test conditions
Test apparatus
SONOSCREEN ST10
Voltage
100 V
Damping
400
Pulse width
125 ns
22
Probe Selection
DGS-Diagram
Noise level
Pulse Shape
Spectrum
23
Probe Selection
24
Probe Selection
Angle
WS 45-2
WS 60-2
WS 70-2
WS 45-4
WS 60-4
WS 70-4
45
60
70
45
60
70
2 MHz
2 MHz
2 MHz
4 MHz
4 MHz
4 MHz
8 x 9 mm
8 x 9 mm
8 x 9 mm
8 x 9 mm
8 x 9 mm
8 x 9 mm
100 01 0170
100 01 0171
100 01 0172
100 01 0173
100 01 0174
100 01 0175
Page
26
28
30
32
34
36
Connection: LEMO 00
Medium types
Type
Angle
WM 45-2
WM 60-2
WM 70-2
45
60
70
2 MHz
2 MHz
2 MHz
14 x 14 mm
14 x 14 mm
14 x 14 mm
100 02 0012
100 02 0013
100 02 0014
Page
38
40
42
Connection: LEMO 00
Large types
Type
Angle
WL 45-2
WL 60-2
WL 70-2
45
60
70
2 MHz
2 MHz
2 MHz
20 x 22 mm
20 x 22 mm
20 x 22 mm
100 01 0176
100 01 0177
100 01 0178
Page
44
46
48
Connection: LEMO 1S
Optional accessories
Connection cable
Couplant
Calibration blocks
25
Probe Selection
SONOSCAN WS 45-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 8 x 9 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
35
10
-51
dB
Index point
13
mm
Angle of incidence *
45
Degree
7.0
Degree
4.6
Degree
Squint angle
<2
Degree
Offset
<1
mm
15
8x9
Transducer dimensions
2.5
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
1 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
18 g
Label
Order number
100 01 0170
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
26
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
27
Probe Selection
SONOSCAN WS 60-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 8 x 9 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
40
10
-53
dB
Index point
12
mm
Angle of incidence *
60
Degree
7.5
Degree
4.6
Degree
Squint angle
<2
Degree
Offset
<1
mm
15
8x9
Transducer dimensions
2.5
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
1 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
18 g
Label
Order number
100 01 0171
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
28
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
29
Probe Selection
SONOSCAN WS 70-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 8 x 9 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
35
10
-55
dB
Index point
12
mm
Angle of incidence *
70
Degree
8.0
Degree
4.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
15
8x9
Transducer dimensions
2.5
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
1 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
18 g
Label
Order number
100 01 0172
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
30
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
31
Probe Selection
SONOSCAN WS 45-4
Angle Beam Probe for Transverse Waves
Transducer dimensions: 8 x 9 mm
Center frequency:
4 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.2
MHz
Relative bandwidth @ -6 dB
40
10
-44
dB
Index point
13
mm
Angle of incidence *
45
Degree
4.2
Degree
2.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
30
8x9
Transducer dimensions
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
1 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
18 g
Label
Order number
100 01 0173
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
32
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
33
Probe Selection
SONOSCAN WS 60-4
Angle Beam Probe for Transverse Waves
Transducer dimensions: 8 x 9 mm
Center frequency:
4 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.2
MHz
Relative bandwidth @ -6 dB
35
10
-45
dB
Index point
12
mm
Angle of incidence *
60
Degree
5.0
Degree
2.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
30
8x9
Transducer dimensions
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
1 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
18 g
Label
Order number
100 01 0174
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
34
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
35
Probe Selection
SONOSCAN WS 70-4
Angle Beam Probe for Transverse Waves
Transducer dimensions: 8 x 9 mm
Center frequency:
4 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.2
MHz
Relative bandwidth @ -6 dB
35
10
-50
dB
Index point
11
mm
Angle of incidence *
70
Degree
5.5
Degree
2.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
30
8x9
Transducer dimensions
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
1 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
18 g
Label
Order number
100 01 0175
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
36
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
37
Probe Selection
SONOSCAN WM 45-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 14 x 14 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
35
10
-46
dB
Index point
21
mm
Angle of incidence *
45
Degree
3.5
0.5
Degree
0.5
Degree
Squint angle
<2
Degree
Offset
<1
mm
39
14 x 14
Transducer dimensions
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
2 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
52 g
Label
Order number
100 02 0012
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
38
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
39
Probe Selection
SONOSCAN WM 60-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 14 x 14 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
35
10
-48
dB
Index point
19
mm
Angle of incidence *
60
Degree
3.5
0.5
Degree
0.5
Degree
Squint angle
<2
Degree
Offset
<1
mm
39
14 x 14
Transducer dimensions
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
2 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
52 g
Label
Order number
100 02 0013
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
40
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
41
Probe Selection
SONOSCAN WM 70-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 14 x 14 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
35
10
-51
dB
Index point
17
mm
Angle of incidence *
70
Degree
3.5
0.5
Degree
0.5
Degree
Squint angle
<2
Degree
Offset
<1
mm
39
14 x 14
Transducer dimensions
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 00
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
2 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
52 g
Label
Order number
100 02 0014
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
42
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
43
Probe Selection
SONOSCAN WL 45-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 20 x 22 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
40
10
-43
dB
Index point
32
mm
Angle of incidence *
45
Degree
3.0
Degree
2.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
90
20 x 22
Transducer dimensions
15
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 1S
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
2 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
85 g
Label
Order number
100 01 0176
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
44
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
45
Probe Selection
SONOSCAN WL 60-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 20 x 22 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
40
10
-44
dB
Index point
30
mm
Angle of incidence *
60
Degree
3.5
Degree
2.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
90
20 x 22
Transducer dimensions
15
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 1S
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
2 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
85 g
Label
Order number
100 01 0177
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
46
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
47
Probe Selection
SONOSCAN WL 70-2
Angle Beam Probe for Transverse Waves
Transducer dimensions: 20 x 22 mm
Center frequency:
2 MHz
Transducer Characteristics
Reference
Tolerance
Dimension
Center frequency
0.1
MHz
Relative bandwidth @ -6 dB
40
10
-44
dB
Index point
28
mm
Angle of incidence *
70
Degree
4.0
Degree
2.4
Degree
Squint angle
<2
Degree
Offset
<1
mm
90
20 x 22
Transducer dimensions
15
mm
mm2
Transducer material
Piezoelectric ceramics
Electrical connector
LEMO 1S
Housing material
Anodized aluminum
Protective layer
Plastics
Wear allowance
2 mm
Working temperature
0 C ... +60 C
Storage temperature
-20 C +70 C
Weight
85 g
Label
Order number
100 01 0178
All values refer to steel as described in EN 12223 concerning manufacture of calibration block no. 1, temperature range 23 5 C.
* Guaranteed for a working temperature of 10 40 C (caused by temperature dependency of sound velocity)
Test Conditions
Test apparatus
SONOSCREEN ST10
Intensity
100 V
Damping
50
48
Probe Selection
DGS-Diagram
Pulse Shape
Spectrum
Electrical Impedance
49
Probe Selection
E-mail:
Internet:
sonotec@sonotec.de
www.sonotec.eu
2014
SONOTEC Ultraschallsensorik Halle GmbH
All rights reserved
The content of this document is the property of SONOTEC Ultraschallsensorik
Halle GmbH and is protected by copyright. Duplication and distribution in any form,
particularly reprinting, photographic, mechanical or electronic reproduction, or in
the form of storage in data processing systems or data networks, is prohibited
without the consent of the copyright holder.