P.D.. 1096
Maximum height of a combustible stand.
Minimum spacing for seats in a chair type measurement from back to back.
Maximum line of travel to an exit of an aisle.
Maximum slope of an aisle.
In standard seating, the minimum spacing of rows measured from back to back.
Minimum width of any seat.
Minimum area of a double acting door view panel.
Minimum clear width of an exit doorway.
Maximum width of an exit door leaf.
Minimum width of an exit corridor.
Minimum number of exit for floors above the first storey having an occupant load of
more than 10
Number of exit for occupant load of 599-999.
Minimum downward projection of a draft curtain
Maximum floor area for an attic made of combustible materials.
Maximum center to center spacing of a draft curtain sprinkler.
Maximum floor area for an attic made of incombustible materials.
Standard gauge for metal hoods in barbeques.
Minimum height of a Siamese connection above grade.
Standard maximum distance of a standpipe from an opening in a stairway.
Minimum wall thickness of a fireplace.
Minimum number of exit for a projection room.
Minimum extended portion of a chimney above the roof.
Minimum air space between walls of a masonry chimney above the roof.
Minimum thickness of glass used for floors.
Maximum rise of one row of seat to the next.
Minimum number of exit for stands within a building serving an occupant load of 300.
Minimum height of a guard rail located in front of the grandstand.
Minimum width of a run in a stand stair.
Minimum spacing for seats with backrests measured from back to back.
Minimum spacing for seats without backrests measured from back to back.
Minimum width of an exit door in an aisle.
Minimum intensity of lights for exits.
Minimum width of side aisles.
Minimum increase in width of aisles for every linear meter.
Minimum width of an aisle serving only one side.
Open space requirement for an interior lot.
Open space requirement for a corner lot or a through lot.
Bounded on all sides or around its periphery by building lines.
Minimum stair width for a residence.
Standard minimum area of a toilet.
Minimum dimension of a kitchen.
Minimum area for vent shafts.
Air space requirement for a school room per person.
Air space requirement for a habitable room per person.
Minimum area of opening of an air duct.
Maximum projection beyond the property line of a footing along the national road and at
least 2.40 mts. In depth.
Minimum clearance of a canopy or a marquee from the sidewalk.
Minimum stair width for occupant load of less than 50.
Minimum width of a temporary walkway.
Minimum clearance of an arcade above sidewalk.
Vacant space left between the building and lot lines less than 2.00 mts in width.
Minimum horizontal dimension of a court.
Minimum width of a passageway connecting a street and a court.
Page 1 of 6
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
12.00 cum.
1.80 mts.
0.30 cum
10% of flr. Area
0.60 mtr.
300 mm
2.40 mts.
2.40 mts.
600 kgs./sqm.
1.00 mtr.
120 kgs./sqm.
0.90 mtr.
2.70 mts.
0.80 mtr.
1.20 mts.
One is to ten (1:10)
250 mm
2.00 mts.
One is to Eight (1:8)
1.20 m
6.00 mts.
2
1.20 mts.
750 mm
5.60 mm
1.20 mts.
900 mm
2.50 mts.
Show window
1.20 mts.
1.00 mtr.
10% of lot area
300 mm
One is to ten (1:10)
2
1.50 mts.
1:125 sqm. Of gross floor area
2.40 X 5.00 mts.
1:10 bedrooms
1:25 beds
60.00 mts.
1:5 classrooms
1:50 sqm. Of spectators' area
4
0.90 mtr.
1.10 X 1.40 mts.
30.00 mts.
1.40 mts.
0.80 mtr.
1.70 X 1.80 mts.
1.60 mts.
3.70 mts.
200 mm
2.10 mts.
6.00 sqm.
2.00 mts.
Page 2 of 6
300 mm
500 mm
0.90 mts.
200 mm
1.10 mts.
750 mm
100 mm
150 mm
300 mm
5 mm
3.00 mts.
1.00 mts.
7
300 mm
480 mm
8.40 mts
one third (1/3)
100 mm
300 mm
250 mm
150 mm
200 mm
4
900 liters/minute
4" (100mm)
5" (125mm)
6" (150mm)
190 liters/minute
2" (50mm)
2 1/2" (63mm)
23.00 mts
6.00 mts.
38 mm (11/2")
1.00 mtr.
5.00 mts.
3.00 mts.
120 days
0.80 mtr.
500 mm
6.00 mts.
1/3 - 1/4
One is to Eight (1:8)
10.00 mts.
7.5 mts.
7.5 mts.
2.50 mts.
1.20 mts.
3,861 sqcms.
3.00 mts.
3.00 mts.
Page 3 of 6
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
5.50 mts.
277 kgs.
3.00 mts.
28.00 sqm.
18.6 sqm.
9.30 sqm.
1.80 sqm.
5.60 sqm.
3.25 sqm.
2.80 sqm.
8.40 sqm.
46.50 sqm.
28.00 sqm.
0.65 sqm.
1 slot/5 rooms
1 slot/50 sqm. Of spectators' area
1slot/8 units
1 slot/unit
1 slot/4 units
1 slot/100 sqm of gross flr.area
1 slot/unit
1 slot/50 parking slots
1 slot/5 classrooms
1 slot/10 classrooms
1.20 mts.
1:20
1:12
12.00 mts.
1:12
60.00 mts.
1.50 mts.
0.50 mts.
1.10 mts.
0.90 mts.
1.20 mts.
3.70 mts.
0.70 mtr.
6.00 mts.
1.50 mts.
Dwelling unit
Footing
Course
Apartment
Barbecue
Balcony
Chimney connector
Fireplace
Girder
Page 4 of 6
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
Helistop
Suportales
Vault
Cross wall
18.60 sqm.
1.40 sqm.
0.65 sqm.
120 days / 4 mos.
8.00 mts.
12.00 cum.
3.00 mts.
800 mm / 0.80 mtr.
500 mm
Business and mercantile
Industrial
Residentials, hotels
and apartments.
Storage and hazardous
Institutional
3.50 mts.
1:12
1.80 mts.
Institutional
Residentials, hotels
and apartments.
Business and mercantile
Industrial
Accessory
1 truck loading slot
60 mts.
20%
1/50 sqm of gross floor area
1/150 sqm of shopping flr area
1/100 sqm of shopping flr area
1/living unit
1/8 living units
1/50 sqm of congregation are
0.60 mtr.
1.00 mtr.
4.50 mts.
4.50 mts.
Accessory
Storage and hazardous
Industrial
Page 5 of 6
Page 6 of 6