Air supply per person per minute for auditoriums; 0.3 cubic meters.
Minimum horizontal clearance of the curb line to the outermost edge of the marquee;
300 mm.
Minimum wind load capacity for roofs for vertical projection; 120 kilograms
per square meters.
Maximum distance of any portion of a building from the nozzle of a 23 meters fire
hose; 6 meters.
Minimum open space requirement for a corner lot; 10% of lot area.
Office building parking ratio; 1 is to 125 square meters Of gross floor area.
Minimum number of wheelchair seating space for 51 to 300 seating capacity for
auditoriums; 4.
Minimum height of signs on walls and doors for the disabled to see comfortable;
1.4 meters.
Minimum dimensions for an accessible water closet stall; 1.7 by 1.8 meters.
Maximum height of signs on walls and doors for the disabled to see comfortably;
1.6 meters.
Minimum ceiling height from 3rd floor to succeeding floors with artificial
ventilation; 2.1 meters.
-----------------------------------------------------------------------------------
-------------------------------------------------
Minimum width of an exit door; 0.9 meters.
Maximum width reduced by handrails and doors fully opened to balconies and
corridors ; 200 mm.
Maximum reduction in width of a stair due to trims and handrails; 100 mm.
Maximum number of seats between the wall and the aisle; 7 seats.
Maximum distance between the back of each seat to the front of the seat behind it;
300 mm.
Maximum ratio of a penthouse area to that of the supporting roof; one third .
Minimum thickness of rubble stone masonry chimney for residentials; 300 mm.
minimum thickness of front and side smoke chamber walls; 200 mm.
Minimum volume of water a dry standpipe should provide; 900 liters per
minute.
Minimum volume of water an interior wet standpipe should provide; 190 liters
per minute.
Maximum projection into a sidewalk of a sign 4.5 mts. above grade; 1 meter.
Minimum horizontal distance of the curb line to the outermost face of an arcade;
500 mm
Slope of driveway to sidewalk where the height of curb is 200 mm and above;
One is to Eight.
Minimum vertical clearance of primary lines from the crown of the pavement when
crossing the highway ; 10 meters.
Minimum vertical clearance of primary lines from top of sidewalk when installed
along the side of the highway; 7.5 meters.
Vertical clearance of secondary lines from sidewalks along or crossing the street;
7.5 meters.
Minimum clearance of conductors from the highest point of a roof; 2.5 meters.
)))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))
)))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))))
The unit area per occupant for dining establishments; 1.4 square meters.
The unit area per occupant for theaters; 0.65 square meters.
Offices shall be provided how many cubic meters of air per person; 12 cubic
meters.
Multiple living units of up to 6 units built on the same lot shall have an access
road directly connecting said building to a public street a width of.; 3
meters.
Sidewalks of 2 meters or more in width shall include on its outer side a planting
strip of not less than how many millimeters in width; 800 mm or 0.8 meter.
Arcades shall be cantilevered from the building line over the sidewalk and the
horizontal clearance between the curb line and the outermost face of any part of
the arcade shall not be less than; 500 mm.
Repair garages shall be classified under what type of occupancy; Storage and
hazardous.
Turnabout should also be provided at or within how many meters of dead end;
3.5 meters.
Under B.P. 344, a level area of not less than how many meters shall be provided at
the top and bottom of any ramp; 1.8 meters.
Under what classification of occupancy does cold storage and creameries fall;
Industrial.
Minimum loading slot requirement for Hospitals and hotels; 1 truck loading
slot.
Percentage required for number of parking if parking garages are available within
200 meters of structure; 20%.
Parking requirement for markets; 1 per 150 square meters of shopping floor
area.
Parking requirement for multi-family living units of more than 100 square meter of
living unit area; 1 per living unit.
Maximum projection of a balcony over a street of over 3 meters but not more than 6
meters; 0.6 meter.
Maximum height of 1st the floor for a 2-story wood structure with a height of 7
meters; 4.5 meters.
Maximum spacing of posts for 2-storey wooden structure with a height of 8 meters;
4.5 meters.
Under what classification of occupancy does fences of over 1.8 meters in height
fall; Accessory.
Under what classification of occupancy does police and fire stations fall;
Business and mercantile.
How many meters above the floor is the comfortable reach of persons confined to a
wheelchair; 0.7 to 1.2 meters.
How many meters is the comfortable clearance for knee and leg space under tables
for wheelchair users; 0.74 meters.
A raised rim of concrete, stone or metal which forms the edge of street, sidewalk,
etc; Curb.
___________________________________________________________________________________
_____________________
Courtrooms with an occupant load of more than 100 are classified under what
classification of occupancy; Assembly.
Armories with an occupant load of more than 100 are classified under what
classification of occupancy; Assembly.
Rooms where baled, bundled or piled materials segregated into desired sizes or
groups; Picking rooms.
An air compartment or chamber to which 1 or more ducts are connected and which form
part of an air distribution system; Plenum.
A process where a piece of metal is heated prior to changing its shape and
dimension; Forging.
The process of first raising the temperature to separate the more volatile from the
less volatile parts and then cooling and condensing the result vapor so as to
produce a nearly purified substance; Distillation.
A finely powdered substance which, when mixed with air in the proper proportion and
ignited will cause an explosion; Dust.
The minimum temperature at which any material gives off vapor in sufficient
concentration to form an ignitable mixture with air; Flash Point.
A gas, fume or vapor used for the destruction or control of insects, fungi, vermin,
germs, rodents or other pests; Fumigant.
Minimum width of any driveway in and around a lumber yard or piles; 4.5
meters.
Minimum height of fence for a lumber yard for exterior storage of lumbers;
1.8 meters.
Maximum width of sumps for the retention of oil and petroleum products; 3.7
meters.
For Refineries, distilleries, and chemical plants, the minimum height for a fence;
1.5 meters.
Minimum travel distance from any individual room subject to occupancy by not more
6 persons; 15 meters.
Maximum distance of travel from the high hazard area to an exit; 23 meters.
Minimum distance of an incinerator from any structure used other than a single
family dwelling; 3 meters.
Minimum stair width for a class B stair serving an occupant load of less than 50;
91 centimeters.
Length of a nosing or effective projection over the level immediately below it for