You are on page 1of 32

Institut Latihan Sultan Ahmad Shah

(ILSAS)

KURSUS LATIHAN KEKOMPETENAN

PERLINDUNGAN PENGHANTARAN
(SETAKAT 132kV)
Unit Perlindungan
Seksyen Latihan Penghantaran
Institut Latihan Sultan Ahmad Shah (ILSAS)
Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Institut Latihan Sultan Ahmad Shah


(ILSAS)

PENGENALAN KEPADA SISTEM


SCADA
Disampaikan Oleh :
Ramlah Binti Awang
Jurutera Telekontrol Unit sekunder
Senggaraan Rangkaian Tengah

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

Subjek: KONSEP ASAS SISTEM SCADA


132kV

15MVA
132/11kV

OPEN??
CLOSE??

Pusat Kawalan
Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

OPEN??
CLOSE??

11kV

PMU
Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

OBJEKTIF
MENGENALPASTI

PERBEZAAN
RTU
&
SAS

KOMPONEN
ASAS SCADA

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

FUNGSI
KOMPONEN

JENIS DATA

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

PENGENALAN
SCADA

Supervisory
Control
And
Data
Acquisition

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

NLDC-Single Line Diagram

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

TERMINOLOGI
Operator

-Jurutera Kawalan di Pusat kawalan


Out station - PMU
Master Station Pusat Kawalan
Supervisory Control
- Kawalan dari jarak jauh yang melibatkan operator.
Remote Control
-Kawalan dipanel bilik kawalan di PMU terlibat melalui
Authorize Person/SSO
Automatic Control
-Kawalan automatik dari jarak jauh tanpa melibatkan
operator.
Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

TERMINOLOGI (sambungan)
LDC

Load Dispatch Center

RTU

Remote Terminal Unit

SAS-

Substation Automation System

SCS-

Substation Control System

BCU-

Bay Control Unit

AGC- Automatic
SAMs-

Generation Control

Substation Alarm Monitoring System

Tx

Transmit

Rx

Receive

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

OBJEKTIF
MENGENALPASTI

PERBEZAAN
RTU
&
SAS

KOMPONEN
ASAS SCADA

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

FUNGSI
KOMPONEN

JENIS DATA

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

JENIS SISTEM SCADA

RTU

SAS/SCS

telinga
mata

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

tangan

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

PERBEZAAN ANTARA RTU & SAS


PUSAT
KAWALAN

RTU

COMMUNICATION MEDIUM
TX
-48 VDC

RX

RTU

RP
CP

HV
APPARATUS

LDC
Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

PERBEZAAN ANTARA RTU & SAS


PUSAT
KAWALAN

SAS/SCS

COMMUNICATION MEDIUM
TX

RX

HMI

110 VDC

RP
CP
BCU

HV
APPARATUS

***
Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

OBJEKTIF
MENGENALPASTI

PERBEZAAN
RTU
&
SAS

KOMPONEN
ASAS SCADA

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

FUNGSI
KOMPONEN

JENIS DATA

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KOMPONEN ASAS

PMU
NLDC

Communication medium

Out Station

Master Station

PENERIMA

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

PENGHANTAR

PEMBERI

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KOMPONEN ASAS-Out Station


CB

10101100

CP
Data Flow via
Communication
Medium

RP
Comms
RTU
Equipment

LDC

RTCCP
AC/DC

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KOMPONEN ASAS-Master Station


Server

Host Computer

Logger

10101100
Data Flow To or
From PMU via
Communication
Medium

Data

Tkt. 5

Front End

Tkt. 6

Printer
Control Engineer Work Station 1
Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Control Engineer Work Station 2


Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

COMMUNICATION
COMMUNICATION
FIBER

MEDIUM

OPTIC

PLC
PILOT CABLE
LEASE

LINE
RADIO MODEM

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

OBJEKTIF
MENGENALPASTI

PERBEZAAN
RTU
&
SAS

KOMPONEN
ASAS SCADA

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

FUNGSI
KOMPONEN

JENIS DATA

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

DATA-Jenis Dan Kegunaannya


Data

dari OS ke MS (Monitoring Direction):

Analog

: Mwatt, Mvar, KV, Hz dan Tap Position


Alarm & Indication: Voltage free contact from plant
Data

dari MS ke OS (Command Direction):


Operasi Kawalan oleh NLDC: Open/Close CB &
Isolator, Raise-Lower Tap Position, Select-Cancel AVR

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

DATA-Jenis Dan Kegunaannya


ANALOG

CT & VT

Daripada keluaran Transducer

TRANSDUCER 4-20mA

ADC
(RTU)

10101100

TO
MASTER
STATION

Aux. Supply 110VDC

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

DATA-Jenis Dan Kegunaannya


DIGITAL

Voltage Free Contact

1 or 0
Open or Close

PLANT EQUIPMENT

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

TO
1 or 0 MASTER
STATION

LDC

RTU

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

DATA-Jenis Dan Kegunaannya


CONTROL

48VDC HDIR
+48Vdc

-48Vdc

48Vdc HDIR Coil


TRIP

RTU
(Control Card)

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

HDIR contact to
plant 110Vdc

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KONSEP KESELURUHAN SCADA


Communication medium

PMU
NLDC

Out Station

Master Station

Alarms & Indication


Control Operation
Analog Reading

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KEPERLUAN
Kepentingan
Sebagai

SCADA kepada system TNB

wartawan
PMU

NLDC
GENERATION

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

PMU
PMU

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KEPERLUAN
Siapa

yang akan menggunakan system


SCADA ini??
PUSAT

KAWALAN NLDC, RCC

OPP(GSMD)-load forecast

Unit-Unit

Lain-SAMs event tripping & alarms

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KENAPA SCADA??

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

SCADA??
106

CB OPEN
Open CB
*REPORT
*CLOSE CB,RESTORE BACK

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

104

105
103
0MW
0Mvar

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

DENGAN SYARAT!!!
106

104

R
105
103

SUPERVISORY

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

APAKAH YANG BOLEH DIPERHATIKAN

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

KESAN KEPADA SISTEM GRID


LOAD LOSS

GENERATION
FORECAST
SALAH

PEMULIHAN
BEKALAN
LAMBAT

$$$
$$

AKIBATNYA

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

PHILOSOPHY
The Right Information
In the Right Quantity
At the Right Time
To make the Right Decision
And take the Right Action

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang

Institut Latihan Sultan Ahmad Shah


(ILSAS)

Unit Perlindungan, Seksyen Latihan Penghantaran - 2007

Ramlah Awang