A flat horizontal roof has a temperature of 10C in the winter. The roof is square and
measures 40 x 40 m. determine the heat transfer rate from the roof to air at -10C
when the wind velocity is
(a) 2ms-1
(b) 6ms-1
(c) 12ms-1.
For forced convection from a flat plate, use the correlation: Nu = 0:664Re1/2 Pr1/3
Note that the density of air can be estimated to be = 1:2 kgm-3, its viscosity 18 x
10-6 Pa s, its heat capacity Cp = 1:0 kJ kg-1 K-1, and its thermal conductivity
0:024Wm-1 K-1.
Given:
T =10 283 K
T s=10263 K
A roof =1600 m2
1
Nu=0.664 2 Pr 3
air =1.2
kg
m3
KJ
J
=1000
kg K
kg K
k air =0.024
W
m K
Find:
Wind velocity is
V =2
m
s
Q=hA (T sT )
(Eq 0.1)
1
Nu=
VL
(Eq 0.3)
P r=
Cp
k
(Eq 0.4)
Calculate
VL 2 1.2 40
6
=
=5.3 10
6
18 10
Calculate
Pr=
(Eq 0.2)
hL
=0.664 2 Pr 3
k
Pr
Cp 18 106 1000
=
=0.75
k
0.024
Calculate
Nu
1
0.75 3 =1393
1
6
5.3 10 2
1
Nu=0.664 2 Pr 3 =0.664
Calculate
h=
from Eq 0.2
Nu k 1390 0.024
W
=
=0.836
L
40
m K
Calculate
from Eq 0.1