FLOORS REINFORCEMENT
HIGH-PERFORMANCE FLOORS
COMPOSITE STEEL AND CONCRETE STRUCTURES:
STATIC AND ECONOMIC ADVANTAGES
Shank diameter 12 mm
Stud height from 40 a 135 mm
Minimum dimension of base plate: 38 mm
Statically the shear stud connector TECNARIA has better
mechanical characteristics and ductility if compared to a
"Nelson" welded stud of the same shank diameter.
Reduced dimensions of the connector (easily positioned on
most profiled metal decking shape).
Reduced deformation values for limited loads and high
deformation values for high loads (ductile behaviour).
The head prevents the detachment of the slab due to
dynamic stress or excessive deformation.
Each connector is zinc plated
APPLICATION
PRACTICAL, QUIK AND SAFE APPLICATION!
The TECNARIA connectors are very simple to install. Once the profiled decking has been positioned over the beam, the two
high-resistance nails supplied with the connector are fastened in. The operation is simple, quick and safe.
The nails are driven using a powder-actuated tool, with a special barrel.
S 235
S 275
S 355
tensile strength
2
< 510 N\mm
tensile strength
2
< 560 N\mm
tensile strength
2
< 630 N\mm
assembled
pin
assembled
pin
not assembled
pin
*According to EN 10027-1
The TECNARIA stud connector can be fastened with the base plate turned either way. In the fastening phase it can
adapt to a wide variety of steel deck patterns available on the market (base plate minimum dimensions = 38 mm). To get
a correct application the sheet steel must adhere closely to the beam. The base material thickness must be > 8 mm.
Total sheet thickness fastened may not exceed: 2 sheets x 1.0 mm or 1 sheet x 1.5 mm.
Slab Thickness
Pd*
Behaviour
40 mm
50-60 mm
22.5 kN
base plate 38 X 50 mm
Data Sheet
38
Code
CTF 12/40
CTF 12/60
CTF 12/70
CTF 12/80
CTF 12/90
CTF 12/105
CTF 12/125
CTF 12/135
12 X 40 mm
12 X 60 mm
12 X 70 mm
12 X 80 mm
12 X 90 mm
12 X105 mm
12 X125 mm
12 X135 mm
50
Laboratory Tests
The connector's resistance to loading and the efficiency of the nailed (riveted) connection to the steel beam
have been experimentally tested according to Eurocode 4 EN 1994-1-1 "Design of composite steel and
concrete structures - Part 1.1: General rules and rules for builidings".
Push-out tests required for design have been carried out as described in Annex B of Eurocode.
Besides load tests on simply supported composite beam have been conducted, including both beams
connected to solid slab and beams with profiled steel sheeting. The stud's bending tests have been
successfully carried out up to a 90 bending angle. The tests proved the optimum performance of the
connector and of its single parts. Its high deformation capacity justifies the assumption of ideal plastic behaviour of the shear
connection and allows redistribution of shear along the beam.
The tests have been all carried out at the 'Laboratories of the Department of Structural and Transportation Engineering,
University of Padua' (Italy).
Shear resistance
Following design shear resistances have been determined by push tests in accordance with requirements in Annex B of Eurocode 4.
Connector's
height
Shear
resistance Pd
Ductility
Solid slab
height 5-6 cm
40 mm
22.5 kN
Not - ductile
Steel sheeting
# Hi-Bond 55 105 mm of total
slab thickness
90 mm
18.2 kN
Ductile
Steel sheeting
# Hi-Bond 55 115 mm of total
slab thickness
105 mm
26.6 kN
Ductile
Steel sheeting
# Hi-Bond 55 135 mm of total
slab thickness
125 mm
30.6 kN
Ductile
Application
Slab
Rehabilitation
New structure
New structure
New structure
Example
TECHNICAL CHARACTERISTICS
TECNARIA connector's shear resistance with solid slabs
Shear resistance of Tecnaria connector with solid slab is not variable with concrete strength class
(for classes higher than C20/25).
Application
Slab
Example
Solid slab
slab thickness 15 cm
Connector's
height
Shear
resistance Pd
Ductility
125 mm
30.6 kN
Ductile
solid slab
profiled decking
kt = 0,7
hp
Nr
b0
hp
h
hp
1 <1
Where:
Nr is the number of stud connectors in one rib at a beam intersection, (not to exceed 2 in
computations) and other symbols are as defined in figure.
b0
DESIGN SOTFWARE:
ad carlo guazzo
It is advised to choose:
- connectors as high as possible (compatible with the cover over connector required);
- profiled steel sheeting with ribs with high ratio width / height;
- class concrete not lower than C25/30
a valuable tool
bf
tf
tfi
tw
ha
bfi
TECNARIA S.p.A. Viale Pecori Giraldi 55 - Bassano del Grappa (VI) - Italy - Tel. +39. 0424 502029
Fax +39.0424.502386 - E-mail: info@tecnaria.com - http://www.tecnaria.com
TECNARIA reserves the right to modify its product without any prior notice