You are on page 1of 1

NEW BOUNDARY WALL

(EXISTING BOUNDARY WALL


SHALL BE DEMOLISHED)
TYPE 2
A TYPE 1-300mm WIDE
B
INTERNAL TRENCH
TYPE 2
-400 -780 -700
-1000 -1050 -1350 -1300
-450
-1100 -1000
-700 -740
99. 6.598 N

TYPE 1-300mm WIDE


-1185 CP 10
555 E
106 6.158

W1 300x300
-1050
Z

M
103

BRICK WALL U1 S1 TYPE 1-300mm WIDE Q1 O1 L TYPE 2


V1 -650

TYPE 2
-650 CP 14 -1100 -400
INTERNAL TRENCH

CP 11
INTERNAL TRENCH

1000x1000 1200x1200 CP 9
300x300
N
TYPE 2

TYPE 2

7792
P
TYPE 2

TYPE 2 N1 C
-1350 TYPE 2

TYPE 2
K X1
T1 TR-3 P1 TYPE 2 -1300 TYPE 2
R1 M1 O Q
-1000
J1 -1050
-1220 CP 7 K1 TYPE 2 L1
-1050 -720 300x300
CP 8
-755 -1040 300x300

TYPE 1-300mm WIDE


1200x1200
TYPE 2
-505 -1000

CP 6
BRICK WALL -1080 -1250

TYPE 1-300mm WIDE


100.25MSL -900 NEW BOUNDARY WALL
TYPE 2
-1100
100.2MSL
INTERNAL TRENCH

INTERNAL TRENCH
INTERNAL TRENCH

INTERNAL TRENCH

INTERNAL TRENCH

INTERNAL TRENCH
LEVEL DETAILS OF CATCH PITS
TYPE 3-400mm WIDE

CATCH PIT NO. opening size (mxm) INVERT LEVEL (MSL)


CP 1 1.2 x 1.2 101.30
R S

TYPE 1-300mm WIDE


TYPE 1-300mm WIDE
CP 2 1.2 x 1.2 100.30
-1100 TYPE 1 D CP 3 1.2 x 1.2 100.20
-1300 CP 4 1.2 x 1.2 100.43

P
CP 5 0.3 x 0.3 100.65
-400 CP 6 1.2 x 1.2 100.53

TYPE 2
-1350 CP 7 0.3 x 0.3 100.55 Structural Details of Drains
CP 4 CP 8 0.3 x 0.3 101.00 Drain type Drain width (mm)
TYPE 2-250mm WIDE

1200x1200 CP 9 0.3 x 0.3 100.65


TYPE 2-250mm WIDE

TYPE 2 -700 Type 1 300


-1150 T W CP 10 0.3 x 0.3 100.65 Type 2 250
V CP 11 1.2 x 1.2 100.60 Type 3 400
CP 12 1.2 x 1.2 101.45 Type 4 450

TYPE 2

TYPE 1-300mm WIDE


H1 CP 13 1.2 x 1.2 101.50 Type 5 500
-900 CP 14 1.2 x 1.2 101.62
CP 15 1.2 x 1.2 100.20
TYPE 2 U
-900 -1075 -750
9150 8000 8000 15740 6340 14090 11780
INTERNAL TRENCH
TYPE 2 -1000
TYPE 3-400mm WIDE CP 3 CP 2
TYPE 3-400mm WIDE E
J3 1200x1200 1200x1200

E=1055.181
N=856.945
TYPE 4-450mm WIDE
TYPE 4-450mm WIDE 100.25 MSL 100.3 MSL TYPE 4 -450mm WIDE
100.1 MSL 100.15 MSL 100.5 MSL
TYPE 4-450mm WIDE TYPE 4-450mm WIDE
Rev. No. Date Description Drawn Checked Approved
100.15MSL 100.2 MSL 100.7 MSL
Employer
100.8 MSL

REFER ACCESS
ROAD DRAIN
LAYOUT
CEYLON ELECTRICITY BOARD
GENERAL NOTES:-
SRI LANKA
Contractor
(1) ALL DIMENSIONS ARE IN mm. UNLESS OTHERWISE SPECIFIED. SIEMENS LTD. India
(PLOT NO. 6A, SECTOR-18, GURGAON, HARYANA)
(2) THE CHAINAGES & ROAD LEVELS ARE GIVEN IN METERS
Project Title
(3) ALL COORDINATES ARE GIVEN IN METERS GREEN POWER DEVELOPMENT AND ENERGY EFFICIENCY
100mmTHICK CLEAN HARD CRUSHED IMPROVEMENT INVESTMENT PROGRAMME-PART2-LOT B1
STONE LAYER GRADED FROM 16-40 (4) ALL DRAINS IN SWITCH YARD AREA WILL BE COVERED WITH PRECAST COVER SLAB
Contract No. Drawing Title:
(5) MINIMUM SLOPE OF 0.5% SHALL BE MAINTAINED ON ALL DRAINS CEB/AGM/TR/2014/1CB/GPDEEIIP1-2/B1
DOCUMENT TREE NO: P90924-1B1-EC1-8861 DRAINAGE LAYOUT
(5) 225 PVC PIPES SHALL BE PLACED 50mm ABOVE THE CATCH PIT INVERT LEVEL
Signature Date
FOR 132/33 kV SUBSTATION AT ANURADHAPURA GSS.
Drawn CSH 24.09.16
TYPICAL CROSS SECTION FOR INTERNAL DRAIN TRENCH (6) FINISHING LEVEL OF THE DRAINS SHALL BE BASED ON SURFACE CHIPPING LEVEL.
Designed HACJ 24.09.16
(7) FGL CORRESPONDS TO 0.0 M Checked KKND 24.09.16 Scale - 1:25 Size - A2 Rev.

RELEASED FOR
Preliminary
(8) INVERT LEVELS ARE SHOWN IN "mm" FROM FGL TO TOP OF THE BASE SLAB OF CABLE TRENCHES Dwg. No. Sheet. No.
Engineering Approval 0
(2)-G71770-AE90924-V160-1B-F02-0 No. of Sheets
Construction