MMC-GAMUDA KVMRT (PDP) SDN BHD

PROJEK MASS RAPID TRANSIT LEMBAH KELANG JAJARAN SUNGAI BULOH


KAJANG

O&M MANUAL
SEWERAGE PUMPING STATION
PACKAGE DPT 1: CONSTRUCTION AND COMPLETION OF
SUNGAI BULOH MAINTENANCE DEPOT, ADMINISTRATION
BUILDING, EXTERNAL WORKS AND OTHER ASSOSIATED
WORKS

Document No. : KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023

WPC Ref. No. : N/A

Revision : 00

Date Issued : 30/09/2016

Prepared by Reviewed by Approved by

NOORIDAYU DAVID KHOO


Name Name CHIN MIN NGEE Name
MAT RIPIN TAT WAI
SR.
QAQC PROJECT
Position Position CONSTRUCTION Position
MANAGER MANAGER
MANAGER

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 1 of 35


KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

REVISION HISTORY

REVISION NO. ISSUE DATE DETAILS OF REVISION


00 23/03/2016 Initial Submission

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 2 of 35

Page 2 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

TABLE OF CONTENTS

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 3 of 35

Page 3 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

1 INTRODUCTION 5

1.1 PURPOSE 5

1.2 SCOPE 5

2 ABBREVIATIONS & DEFINITIONS 5

2.1 ABBREVIATIONS 5

2.2 DEFINITIONS 5

3 REFERENCES 6

3.1 PROJECT DOCUMENTS 6

3.2 STANDARDS 6

4 O&M DOCUMENT STRUCTURE 6

5 O&M MANUAL CONTENT 7

5.1 VOLUME 1: GENERAL INFORMATION 7

5.1.1 INTRODUCTION 7

5.1.2 DESIGN CONCEPT 7

5.1.3 FEATURES & PERFORMANCE 7

5.1.3.1 PRIMARY SCREEN CHAMBER 7

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 4 of 35

Page 4 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

5.1.3.2 PUMP SUMP 7

5.2 VOLUME 2: OPERATION MANUAL 8

5.3 VOLUME 3: MAINTENANCE MANUAL 8

5.3.1 INTRODUCTION 8

5.3.2 SAFETY INFORMATION 8

5.3.3 MAINTENANCE PLANNING DATA 9

5.3.3.1 LUBRICATION 9

5.3.3.2 PENSTOCKS 9

5.3.3.3 PUMPS AND ANCILLARY 9

5.3.3.4 VALVE AND PIPEWORKS 9

5.3.3.5 LEVEL CONTROL 9

5.3.4 PREVENTIVE MAINTENANCE 10

5.3.4.1 MAINTENANCE WORKS 10

5.3.5 CORRECTIVE MAINTENANCE 11

5.3.6 WORKSHOP MAINTENANCE & OVERHAUL 11

5.4 VOLUME 4: ILLUSTRATED PART CATALOGUE 11

5.4.1 INTRODUCTION 11

5.4.2 SAFETY INFORMATION 12

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 5 of 35

Page 5 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

5.4.3 CLASSIFICATION OF SPARE PARTS 12

5.4.4 PARTS CATALOGUE 12

5.4.5 STORAGE REQUIREMENTS 12

5.4.6 DISPOSAL 12

5.5 VOLUME 5: DIAGNOSTIC TEST EQUIPMENT & SPECIAL TOOLS MANUAL 12

APPENDIX 1 PRODUCT CATALOGUE


APPENDIX 2 SEWERAGE PUMP TROUBLESHOOTING & INSTRUCTION MANUAL

List of Tables
Table 2-1: Table of Abbreviations............................................................................................5
Table 2-2: Table of Definitions................................................................................................5
Table 3-1: List of References ~ Contractual Documents.........................................................6
Table 3-2: List of References ~ Standards..............................................................................6
Table 4-1: O&M Manual Structure..........................................................................................6
Table 5-1: General................................................................................................................ 10
Table 5-2: Primary Screen Chamber....................................................................................10
Table 5-3: Pump Sump (Wet Well).......................................................................................10
Table 5-4: Control Panel.......................................................................................................11
Table 5-5: Product Material Details 1....................................................................................11
Table 5-6: List of Supplier.....................................................................................................11

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 6 of 35

Page 6 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 7 of 35

Page 7 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 8 of 35

Page 8 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

1 INTRODUCTION
This sewerage pumping station is designed in compliance to the design guideline
(Guidelines for Developers Vol. III Sewer Networks and Pump Station. This operation and
maintenance (O&M) manual for the sewerage pump station in KVMRT Sg. Buloh Depot.

1.1 Purpose
The purpose of this document is to be used as a guide for proper operation and
maintenance for the sewerage pump station. This is to prevent damages blockage, which
might result in losses. This manual should be read carefully before any operation and
maintenance works. Proper operation instruction and procedure must be adhered to ensure
optimum efficiency and to pro-long the life span of the equipment.

1.2 Scope
This manual shall cover and explains operation and maintenance procedure required for the
sewerage pump station in KVMRT Sungai Buloh Depot.

2 ABBREVIATIONS & DEFINITIONS


The following table lists out the abbreviation and acronyms used in this document.

1.3 Abbreviations
Abbreviation Definition
KVMRT Klang Valley Mass Rapid Transit

MRT Corp Mass Rapid Transit Corporation Sdn Bhd

PDP Project Delivery Partner

IPC Illustrated Part Catalogue

Table 2-1: Table of Abbreviations

1.4 Definitions
Terms Definition
Project Projek Mass Rapid Transit Lembah Klang ~ Sungai Buloh-
Kajang

Table 2-2: Table of Definitions

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 9 of 35

Page 9 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

3 REFERENCES

1.5 Project Documents

Document Number Document Title

KVMRT-PDP1-SBK-SC08A-
Operation and Maintenance Manual Specification
SYSW-SPC-OPM-000001

As-Built Drawings Sewerage Pump Station

Table 3-3: List of References ~ Contractual Documents

1.6 Standards

Document Number Document Title

Guidelines for Developers Sewer Networks and Pump Station


Vol. III (Malaysian Sewerage Industry Guidelines)

Table 3-4: List of References ~ Standard

4 O&M DOCUMENT STRUCTURE


The O&M Manual shall consist of four (4) major volumes as described in Table 4-1. This
arrangement will allow different users referring to the relevant volume easily without having
to read whole document. This O&M manual for sewerage pump station does not include the
Volume 5: Diagnostic Test Equipment & Special Tools Manual which is not applicable.

Volume Manual Title Key End User Remarks


1. Operation Staff
1 General Information Manual 2. Maintenance Staff
3. Training Staff
1. Operation Staff
2 Operation Manual
2. Training Staff

1. Maintenance Staff
3 Maintenance Manual
2. Training Staff

1. Maintenance Staff
4 Illustrated Part Catalogue
2. Training Staff

Diagnostic Test Equipment & 1. Maintenance Staff


5 Not Applicable
Special Tools Manual 2. Training Staff

Table 4-1: O&M Manual Structure

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 10 of 35

Page 10 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

5 O&M MANUAL CONTENT


This section describes the details information of material and finishes use at the respective
buildings including typical maintenance action or activities in effective manners.

1.7 Volume 1: General Information Manual


1.7.1 Introduction

This manual shall provide the general information for sewerage pump station in KVMRT
Sungai Buloh Depot including suppliers details, operation and maintenance information for
the installed equipment.

1.7.2 Design Concept

Through gravity, the domestic wastewater collected from all the buildings in KVMRT Sungai
Buloh Depot will end up flowing into the last manhole and subsequently into the primary
screen chamber of the pump station.
This is where the raw wastewater will undergo the primary screening before it is
accumulated in pump sump. The untreated raw wastewater will, when it reaches certain
level, be pumped up, through D.I. force main, into the nearest and approved existing public
sewer manhole, which would lead to an existing public sewage system.

1.7.3 Features & Performance

1.7.3.1 Primary Screen Chamber

This is often the first stage of treatment in pump station. The screen must be provided
upstream of flow to protect the downstream processes and equipments from rags, woods
and other junky debris as well as to reduce interference with in-plant flow and performance.
All solids must be removed from the collection bin and disposed off regularly by the SPAN
licensed contractor.

1 Pump Sump

Inlet of pumping sump must be preceded by primary screen for protection of pumps from
being damaged or clogged. The inlet pumps of treatment works have to be equipped
with sewage application pumps and not water pumps. This is due to the characteristic of
the sewage flow that is not compatible with normal water pumps. The raw sewage will be
pumped via 2 nos. raw sewage submersible pumps to, in this case, an existing public
sewer manhole at the neighboring housing estate.

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 11 of 35

Page 11 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

Except during the two designated peak flow moments when two pumps are pumping, only
one pump will be operating in normal flow situation. During normal operations, the pump
is automatically controlled by a high/ low level switches (floating ball).

1.8 Volume 2: Operation Manual


The sewerage pump station is designed to run in automated mode with change over to
manual mode. The followings are the step-by-step description to start up and shut down the
plant: (Please also refer to the electrical circuit drawing for better understanding)

1. Switch on the MCCB (Moulded Case Circuit Breaker) to give power to the
switchboard.
2. Switch on all the MCB (Miniature Circuit Breaker) on the switchboard.
3. Check if the timer settings for other mechanical equipments that are controlled by
time switch are properly set. Ensure that all valves are opened before pumps are
turned on.
4. Turn on all the selector switches for all equipments to the M (manual) position and
test run the equipment one after another.
5. If all the equipments are in order, then turn on all the selector switches to the A
(auto) position for automated operation. It is advised not to shut down the entire
treatment plant unless under specific circumstances and reason.

1.9 Volume 3: Maintenance Manual


1.9.1 Introduction

This section shall cover the maintenance instructions upon first operation of the plant.

1.9.2 Safety Information

This section shall brief general safety information and advice to be considered during the
maintenance operation.

Fence
Fences must be in good condition covering the whole site boundary. There must be no gaps
in or under the fence of more than 100mm. Fences will be minimum 8 feet high. The fence
will have a method of deterring climbing (barbed wire).

Access
Access shall be sufficient width to allow tankers to enter site without to cause damage to the
vehicle, fence, gates or surrounding property and pavements.

Service Condition
MMC-GAMUDA KVMRT (PDP) SDN BHD Page 12 of 35

Page 12 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

Plant and equipment must be maintained by SPAN-licensed contractor at all times.

Odour Levels
The contractor will ensure no unpleasant odors due to operational activities are detectable
outside the site boundary. There will not be any persistent smells or hydrogen Sulphide in
tanks, channels, pump wells, open chambers and plant enclosures.

Main Switchboard
This plant is designed to run in automated mode, therefore it is important to make sure all
push-button are turned on and are set on automatic mode. All checking and testing involving
electrical panel must be done by a qualified person as this panel incoming current involve 3
phase. (415v).

1.9.3 Maintenance Planning Data

This section shall provide sufficient information for the Operators Maintenance Personnel to
define the required maintenance planning data. The following preventive maintenance tasks
shall be conducted at least once every month for the all electrical and mechanical
equipment:-

1.9.3.1 Lubrication

Check / Change / Top up lubricant oil


Service / Replace oil filters
Grease Bearing (It is important to grease as per manufacturer instructions. Lack of
greasing is a major cause of breakdowns. Care has to be taken when greasing the
bearings on electric motors as too much grease can be as harmful as lack of
grease).

1.9.3.2 Penstocks

Inspect, clean and grease operating spindles


Inspect and tighten if necessary all connections, joints, bolts, nuts etc
Repaint with approved epoxy paint all expose bare metal of frame and gate

1.9.3.3 Pumps and Ancillary

To lift up the pump and clean the impeller


Check lifting guide rails and to make sure it is in right position
Check condition of the electrical cables and to make sure that there is no cuts or
swellings
To check cable entry into pump for tightness or any faulty sealant
To off the isolator switch button before lifting up the pumps

1.9.3.4 Valve and Pipework

Check for any blockage in pipework


MMC-GAMUDA KVMRT (PDP) SDN BHD Page 13 of 35

Page 13 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

Clean, inspect and lubricate or grease all valves


Check if valves operate correctly after maintenance and no flow passes through
after the valve is closed.

1.9.3.5 Level Control

Remove, clean, and test level regulators / sensors and adjust accordingly

1.9.4 Preventive Maintenance

1.9.4.1 Maintenance Works:

Routine Inspection

The frequency of Operation and Maintenance (O&M) visit to the pump station shall
be weekly basis.

Task Description

Item Task
Read and record all designated meters (e.g. hours run, ampere
1 readings etc) attach Form/Checklist.

Visual check plant for vandalism and theft


2

3 Operate, lubricate valves and penstocks not in regular use

Check security of grating, sump covers and fencing.


4
5
Clean access roads within site boundary
6
Cut the grass and remove rubbishes

Table 5.1 General

Item Task

1 Clean screen area and dispose of screenings

2 Hose down area and clean out screen bars


Clear rubbishes and large debris from screenings
3
MMC-GAMUDA KVMRT (PDP) SDN BHD Page 14 of 35
Channel

Page 14 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

Table 5.2 Primary Screen Chamber

Item Task
1 Check all equipment for correct operation

2 Clean wet well level control equipment

3 Change duty/ standby rota

Table 5.3 Pump Sump (Wet Well)

Item Task
1 General cleaning

Table 5.4 - Control Panel

1.9.5 Corrective Maintenance

Corrective maintenance shall refer to Appendix 2 Troubleshooting & Instruction Manual for
Sewerage Pump.

1.9.6 Workshop Maintenance & Overhaul

Workshop Maintenance & Overhaul shall refer to Appendix 2 Troubleshooting & Instruction
Manual for Sewerage Pump.

1.10 Volume 4: Illustrated Part Catalogue


1.10.1 Introduction

The section is prepared for the use of maintainer and contains information relating to the
provisioning, requesting, storing and issuing spare parts required for all levels of
maintenance activities.

No Type Brand Model Power Quantity


MMC-GAMUDA KVMRT (PDP) SDN BHD Page 15 of 35

Page 15 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

2 nos
1. Raw Sewerage Pump Ebara 100 DML 511 11.0 kW (1 Duty; 1 Standby)

Table 5-5: Product Material Details 1

Equipment
Model Supplier/Address Tel/Fax
Description
Ebara Pumps Malaysia Sdn. Bhd. Tel: 03-55691655
Raw Sewerage Ebara
20, Jalan Juruhebah U1/50, Fax: 03-
Pump 100 DML 511
Temasya Industrial Park, 55693766
40150 Shah Alam,
Selangor Darul Ehsan

Table 5-6: List of Supplier

1.10.2 Safety Information

Safety information shall refer to item 5.3.2 Safety Information.

1.10.3 Classification of Spare Parts

This section is not applicable for Sewerage Pumping Station Manual. Any replacement shall
contact the supplier of the material Ebara Pump Malaysia Sdn Bhd.

1.10.4 Parts Catalogue

Please refer to the Ebara Pump Catalogue Appendix 1.

1.10.5 Storage Requirements

This section is not applicable for this manual.

1.10.6 Disposal

This section is not applicable for this manual.

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 16 of 35

Page 16 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

1.11 Volume 5: Diagnostic Test Equipment & Special Tools Manual


This section is not applicable for this manual.

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 17 of 35

Page 17 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
SEWERAGE PUMPING STATION Revision: 00

Appendix 1
Product Catalogue

MMC-GAMUDA KVMRT (PDP) SDN BHD Page 18 of 35

Page 18 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 19 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 20 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 21 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 22 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
Appendix 2
Sewerage Pump
Trouble Shooting and Instruction
Manual

MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 23 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 24 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 25 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 26 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 27 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 28 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 29 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 30 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 31 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 32 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 33 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 34 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023
MMC-GAMUDA KVMRT (PDP) SDN BHD

Page 35 of 35
KVMRT-TRC-SBK-PKG1-SUBD-MAN-OPM-000023

You might also like