Product Data

HEMPAREA DTM 55973

55973: BASE 55977: CURING AGENT 98990


Description: HEMPAREA DTM 55973 is a very fast curing, two-component, high solid, DTM-polyurea enamel with
zinc phosphate and good gloss and colour retention.
Recommended use: As a very fast curing, low VOC, high-build enamel for protection of structural steel in medium to sever
corrosive atmospheric environment. To be applied by dual feed airless spray equipment.
HEMPAREA DTM can be used as one coat direct to metal specifications up to C3 according to ISO
12944.
HEMPAREA DTM can be used in C4 and C5 specifications on metallized surfaces according to ISO
12944.
Service temperature: Maximum, dry exposure only: 80C/176F
Availability: Not included in Group Assortment. Availability subject to special agreement.
PHYSICAL CONSTANTS:
Shade nos/Colours: 11150/ Grey.
Finish: Semi-gloss
Volume solids, %: 83 1
Theoretical spreading rate: 4.2 m2/l [168.4 sq.ft./US gallon] - 200 micron/8 mils
Flash point: 23.1 C [73.58 F]
Specific gravity: 1.5 kg/litre [12.8 lbs/US gallon]
Surface-dry: 30 minute(s) 20C/68F
Through-dry: 1 hour(s) 20C/68F
Dry to walk on: 1.5 hour(s) , 20C/68F (RH 50%)
Dry to handle: 2 hour(s) 20C/68F (RH 50%)
Fully cured: 7 day(s) , 20C/68F
VOC content: 145 g/l [1.2 lbs/US gallon] (ISO 3233)
- The physical constants stated are nominal data according to the HEMPEL Group's approved formulas.

APPLICATION DETAILS:
Version, mixed product: 55973
Mixing ratio: BASE 55977: CURING AGENT 98990
4:1 by volume
Application method: Dual feed airless spray
Thinner (max.vol.): HEMPEL'S THINNER 08710
Pot life: 10 minute(s) (20C/68F)
Indicated film thickness, dry: 200 micron [8 mils]
Indicated film thickness, wet: 250 micron [10 mils]
Overcoat interval, min: 2 hour(s) 20C/68F
Overcoat interval, max: 7 day(s) 20C/68F
-
Safety: Handle with care. Before and during use, observe all safety labels on packaging and paint containers,
consult HEMPEL Safety Data Sheets and follow all local or national safety regulations.

Date of issue: July 2016 Page: 1/2


Product Data
HEMPAREA DTM 55973

SURFACE PREPARATION: Remove oil and grease etc. thoroughly with suitable detergent. Remove salts and other contaminants
by high pressure fresh water cleaning. Abrasive blasting to Sa 2 (ISO 8501-1:2007).
APPLICATION CONDITIONS: The surface must be completely clean and dry at the time of application and its temperature must be
above the dew point to avoid condensation.Use only where application and curing can proceed at
temperatures above: 0C/32F
The temperature of paint itself should be 15C/59F or above. For optimal automatic spraying condition
the paint temperature should preferable be kept between: 20-25C/68-77F.
In confined spaces provide adequate ventilation during application and drying.
Curing conditions: Temperature: preferably 15-40C/59-104F. Relative humidity 20-80% preferably
40-60%.
PRECEDING COAT: None or metallization, according to specification.
SUBSEQUENT COAT: None.
REMARKS:

Film thicknesses/thinning: May be specified in another film thickness than indicated depending on purpose and area of use.
Normal range is: 125-250 micron/5-10 mils. This will alter spreading rate and may influence drying time
and overcoat interval.
Curing agent: CURING AGENT 98990 : is sensitive to moisture. Store in a dry place and keep the can tightly closed
until use. Opened containers can be protected either by CO2 or silica driers.
Overcoating intervals: If the maximum over coating interval is exceeded, roughening of the surface is necessary to ensure
intercoat adhesion.
Note: HEMPAREA DTM 55973 For professional use only.
ISSUED BY: HEMPEL A/S 5597311150

This Product Data Sheet supersedes those previously issued.


For explanations, definitions and scope, see Explanatory Notes available on www.hempel.com. Data, specifications, directions and recommendations given in this data sheet
represent only test results or experience obtained under controlled or specially defined circumstances. Their accuracy, completeness or appropriateness under the actual conditions
of any intended use of the Products herein must be determined exclusively by the Buyer and/or User.
The Products are supplied and all technical assistance is given subject to HEMPEL's GENERAL CONDITIONS OF SALES, DELIVERY AND SERVICE, unless otherwise expressly agreed
in writing. The Manufacturer and Seller disclaim, and Buyer and/or User waive all claims involving, any liability, including but not limited to negligence, except as expressed in said
GENERAL CONDITIONS for all results, injury or direct or consequential losses or damages arising from the use of the Products as recommended above, on the overleaf or otherwise.
Product data are subject to change without notice and become void five years from the date of issue.

Date of issue: July 2016 Page: 2/2