PUMPS DIVISION CONTACTS A-1 - A-2
PARTS SECTION:
BARRELS H-1 - H-3
BUSHINGS I-1 - I-2
BUSHINGS, TUBING PUMPS J-1 - J-2
CAGES K-1 - K-53
CONNECTORS - COUPLINGS L-1 - L-6
GUIDES, VALVE ROD M-1 - M-2
NIPPLES N-1 - N-4
PLUGS O-1 - O-3
PLUNGERS P-1 - P-11
PULLERS Q-1 - Q-3
RODS R-1 - R-4
SEATINGS S-1 - S-10
PULL TUBES T-1
SEATS AND BALLS U-1 - U-7
ACCESSORIES V-1 - V-18
A-1
CATALOG 2012.05
Bolland
HEAD OFFICE
Tte. Gral. J.D. Pern 925 - 6 piso, (C1038AAS) Buenos Aires, Argentina
Suipacha 238 - 7 piso, (C1008AAF) Buenos Aires, Argentina
Phone: (54 11) 4320-7500 - Fax: (54 11) 4320-7561
INDUSTRIAL PLANT
Parque Industrial, Macizo 6, (U9006DFA) Comodoro Rivadavia, Chubut, Argentina
Phone: (54 297) 449-0000 - Fax: (54 297) 448-2436
BRANCHES
COMODORO RIVADAVIA
Parque Industrial, Macizo 6, (U9006DFA) Comodoro Rivadavia, Chubut, Argentina
Phone: (54 297) 449-0000 - Fax: (54 297) 448-2436
Base Caadn Seco Phone: (54 297) 485-0082
Ruta Prov. N 12 s/n, (9013) Caadn Seco, Santa Cruz, Argentina
Base Pico Truncado Phone: (54 297) 499-2235
Barrio Industrial, Fraccin E, Seccin D, (9015) Pico Truncado, Santa cruz, Argentina
Base Las Heras Phone: (54 297) 497-5429
1 de Mayo s/n, Parque Industrial, (9017) Las Heras, Santa Cruz, Argentina
Base Los Perales (From Argentina) Phone: (0 297) 15-592-6950
Distrito 4, Divisin Regional Sur, (From abroad) Phone: (54 9 297) 592-6950
(9017) Las Heras - Los Perales, Santa Cruz, Argentina
NEUQUN
Avenida Argentina 1262, (Q8300AYZ) Neuqun, Argentina
Phone / Fax: (54 299) 448-9977 / 449-7000
Industrial Plant: Ruta 7, Km 4,5 (Q8300AYZ) Neuqun, Argentina
Phone / Fax: (54 299) 448-9977 / 449-7000
Base Plaza Huincul Phone: (54 299) 496-3237
Principal Saenz 956, (8322) Cutral-C, Neuqun, Argentina
Base Catriel Phone: (54 299) 491-1443 / 491-4661
Jamaica s/n, Barrio Industrial, (8307) Colonia Catriel, Ro Negro, Argentina
Base Rincn de los Sauces Phone: (54 299) 488-6005 / 488-6007
Parque Industrial, Ruta 6 s/n, (8319) Rincn de Los Sauces, Neuqun, Argentina
MENDOZA
San Martn 1832, Mayor Drummond, (M5507EUL) Lujn de Cuyo, Mendoza, Argentina
Phone: (54 261) 498-9100 - Fax: (54 261) 498-9112
Base Malarge Phone: (54 260) 447-1586 / 447-0960
Jorge Newbery s/n, (5613) Malarge, Mendoza, Argentina
SALTA
Av. Alberdi 1115 y Amrica, (A4560AQL) Tartagal, Salta, Argentina
Phone / Fax: (54 3875) 42-1626 / 42-2000 / 42-2004
A-2
CATALOG 2012.05
Bolland
SUBSURFACE
SUCKER ROD PUMPS
B-1
CATALOG 2012.05
Bolland
INTRODUCTION
The sucker rod pumping is the oldest, the most economical and the most commonly
used method for artificial lifting. It is mechanically simple, it can work under a wide range of
conditions and has a wide variety of available parts and skilled staff. All these conditions make
it a well-accepted and applicable method and approximately 85 percent of all artificially lifted
wells are produced by sucker rod pumps
The sucker rod pump is only one part of the pumping system. The other mayor
components are: the sucker rod string, the tubing, the surface pumping unit and the prime
mover.
In those cases where oil conditions make extraction difficult, it is possible to modify
designs and to use special materials and devices as to lift the desired quantities and improve
service life. Pump low efficiency implies higher energy costs and lower performance, thus
increasing operational expenses.
The choice of an artificial lift system shall consider both technical and economic
aspects, in order to select the most efficient and reliable system at the lowest total operational
cost.
There are two aspects to be considered: no system shall be able to meet all
requirements at the same time and the lifting system chosen shall be replaced during the well
life as a consequence of the change of its operational conditions.
Limitations:
Below graph shows approximate economic application ranges compared with other
pumping systems.
EL EC
2400
TR IC
ME C H
S UB M
2100
HYDRAULIC PUMPS
ANIC
DEPTH (MTS)
ER SIB
1800
LE
1500
=
1200 A U LIC
H Y DR M ER
S.
B MECHANIC=HYDRAULI
C T R IC S U C
E LE
900
MECHANIC
600 SUCKER ROD ELECTRIC SUBMERSIBLE PUMPS
PUMPS
300
1100
1200
200
1000
600
300
400
700
900
500
800
Depth is another factor to be considered in the selection of the pump. In deep wells, the
following elements have to be taken into consideration: pump bore, materials of component
parts and type of anchor.
Bolland y Ca. experienced staff will assist their customers in the selection of the best
alternative for an efficient, reliable and economical production.
D-1
CATALOG 2012.05
Bolland
The downhole sucker rod pump is one of the elements of the Sucker Rod Pumping
System. Its main components are:
The pump stationary assembly, formed by the barrel and the standing valve at its
bottom. In most cases, the stationary assembly is attached to the tubing by an anchor system.
The pump traveling assembly, formed by the plunger and the traveling valve.
The motion of the pumping unit causes in the traveling assembly -through the rods- a
reciprocating movement (uptstroke/downstroke). This movement lifts the fluid from the bottom
of the well to the surface through the tubing.
Likewise, the stationary assembly bears the maximum tension during the downstroke.
These efforts cause the elongation and contraction of the involved parts, with the consequent
reduction in the actual pump stroke.
The effective pump stroke, the slippage of oil between the barrel and the plunger, the
presence of gas and the water content, are some of the aspects to be considered in the
selection of the pump and the estimation of oil production.
The American Petroleum Institute, API, has established the types and sizes of pumps
and components under the 11AX Spec.
This Institute has issued many publications on the subject, such as Recommendation
for the use and care of sucker rod pumps (RP 11AR) and the Recommended practice for
design calculations for sucker rod pumping (RP 11L), amongst others.
There are different types of subsurface pumps for every application. API denominations
appear between brackets.
Below we describe the most commonly used, as well as their advantages and
limitations.
TUBING PUMPS ( TH ) :
The tubing pump is tough in construction and simple in design. The barrel is attached
directly to the tubing and the sucker rods directly connect to the plunger. Below the barrel
there is a seating nipple that locks in place the standing valve.
One of the possibilities consists in lowering the standing valve with a puller coupled to
the plunger bottom until locking it to the nipple. Then, the plunger may be released from the
standing valve when is rotated counterclockwise.
TH pumps provide the largest displacement possible in any size of tubing and the
plunger diameter is slightly smaller than the tubing internal diameter.
The heavy wall barrel is directly connected to the tubing through a nipple.
The sucker rod string connects directly to the plunger top cage, eliminating the need for
valve rods.
Due to its advantages, this type of pump is used by producers in wells where no
frequent controls are needed.
Limitations:
ROD PUMPS ( RH RX RW ) :
The main characteristic of rod pumps is that they are attached to the tubing through an
anchor system, so they can be pulled without disturbing the tubing. This reduces pulling unit
time by more than 50 percent.
For installation purposes, first a seating nipple is run in the tubing; afterwards, the pump
is run by the sucker rods until it clamps on the seating nipple and the pump is ready for
operation.
The widespread use of this type of pumps has generated a variety of options, such as:
The main characteristic of this type of pumps is that the traveling component is the
barrel with its valve, instead of the plunger. In this case, the plunger is clamped to the seat by
means of a hollow tube called pull tube.
Standing and traveling valves are placed in the upper part of the plunger and the barrel,
respectively.
The movement of the barrel keeps the fluid in motion almost down to the seating
nipple; this minimizes the possibility of sand settling around the pump and sticking it.
As the traveling valve in the top cage will seat when the well is shut down, sand cannot
settle inside the pump. This is important since even a small quantity of sand settling on top of
the plunger to cause the plunger to stick when the well starts pumping again.
- The sucker rod string directly connects to the barrel top cage, which is stronger than
the plunger top cage.
- Both the standing and traveling valves have open type cages that allow a better
fluid passage.
- Due to equal pressures outside and inside the barrel, a bottom-anchored pump has
greater resistance to bursting and fluid pound.
Limitations
- They are at a disadvantage in wells that have a low static fluid level due to the higher
pressure drop between the well bore and the pumping chamber caused by the fluid flow
inside the pull tube.
- Since the standing valve is located in the plunger, it is smaller in diameter than the
standing valve of a stationary-barrel pump.
- If, in deep wells, the fluid load is significant, it may cause deformation in the pull tube.
D-4
CATALOG 2012.05
Bolland
TOP ANCHOR HEAVY OR THIN WALL BARREL ROD PUMP ( RWA RHA ) :
Top anchor pumps are widely used in sandy wells. These pumps discharge fluid at the
anchor, thus avoiding the settling of sand and the sticking of the pump.
Deep wells have to be carefully observed, especially in the case of thin wall barrels, as
the inside pressure during downstroke is usually higher than the outside pressure and it may
break the barrel.
BOTTOM ANCHOR HEAVY, HEAVY-WALL BOX THREAD OR THIN WALL BARREL ROD
PUMP ( RWB RXB RHB ) :
In this type of pump, anchor is under the barrel standing valve, so pressures inside and
outside the barrel in the downstroke are equal and depth should not be a problem.
One exception is the case where, due to a restricted intake valve (because of very
viscous fluid or partial blockage of the valve), the barrel does not fill completely during the
upstroke, reducing the pressure inside and causing failure due to dent or collapse.
It is recommended for those wells with low fluid dynamic level, not only because the
pump intake is close to the barrel valve, but also because this valve is bigger than the one for
RHT and RWT. Both conditions significantly improve the pump filling.
There appears a limitation in sandy wells, where sand settles between the barrel and
the tubing from the bottom to the top of the pump, making pump removal impossible. This
situation makes it necessary to remove the tubing full of oil.
As the barrel is open on the top, in case of intermittent operations during the unit
shutdown, sand or other elements may enter the pump and stick the plunger when starting
again.
Hollow-valve Bolland pumps are designed for pumping gassy fluids. Free gas
accumulates in the annular chamber formed by the hollow rod and the barrel, between the
upper plunger side and the rod guide.
The traveling assembly of hollow-valve pumps uses a perforated coupling between the
plunger and the rod lower end, and a cage, with ball and seat, in the respective upper end.
In the downstroke, the closing of the top valve assumes the hydrostatic pressure and
opens the plunger bottom valve. Besides, vacuum created in the chamber allows the passage
of gas through the perforated coupling and its accumulation in the annulus chamber.
In the upstroke, annular chamber compression forces the gas through the perforated
coupling to the hollow rod where it is produced with the fluid.
D-5
CATALOG 2012.05
Bolland
Special attention should be put in deep installations with top anchor, especially with thin
wall barrels, since in case of defective locking of the top valve or leaks in the plunger, the
inside pressure during downstroke may be extremely higher than the outside pressure and
cause the barrel to burst.
As it can be seen from above description of units, their advantages and limitations, and
the variety of existing applications, it is very complex to choose the most suitable equipment
for every application.
Bolland y Ca. technical staff offer their services to producers in order to give
assistance with their knowledge and experience in the selection of the best product for
their needs.
E-1
CATALOG 2012.05
Bolland
FLUID POUND :
When a pump does not fill completely with liquid during the upstroke, a low-pressure
gas cap forms in the top of the pump chamber between the traveling and standing valves.
During the subsequent downstroke, the traveling valve stays closed until it impacts the fluid.
This condition is called Fluid Pound and causes a severe shock load to the entire pumping
system.
Pump off: It occurs when the fluid level is not enough to fill the pump. A Pump Off
condition can be determined by shutting the well down for a few minutes and then restarting
the system. If pump fillage is good after start up and then a short time later a Fluid Pound
condition reoccurs, the Pump Off is confirmed.
Restricted Intake (Starved pump): It occurs when any cause prevents or hinders the
incoming fluid to enter the pump, notwithstanding the sufficient fluid level. Testing for this
condition is accomplished by shutting the well down for a few minutes and restarting the
system. If Fluid Pound occurs immediately after start-up, it is indicative of a Starved Pump
condition.
Viscosity and strokes per minute: The pump chamber incomplete fillage occurs due
to the stationary valve resistance to passage of fluid and the volume required by the pumping
speed.
A Fluid Pound situation during pumping operations is not desirable. Sometimes it can
be detected by vibrations and blows on the surface. In other cases, especially in deep wells, it
can only be seen in dynamometer charts (depending on intensity).
The following actions can be followed in order to reduce or eliminate Fluid Pound
consequences:
E-2
CATALOG 2012.05
Bolland
A good approach to this problem is to design a pumping system that, when working at
80 percent efficiency, will achieve the desired production from the reservoir.
In the case the unit works at a higher efficiency, which is not a very common situation,
Fluid Pound that occurs in the first 20% of the downstroke is less severe, unless it combines
with a critical installation depth.
When pump capacity greatly exceeds the well productivity, some parameters that
regulate the volume pumped such as stroke length or strokes per minute should be changed to
more closely approach good design guidelines.
A timer within the motor control that enables the operator to match pumping time to well
productivity will reduce the Fluid Pound condition. Normally, the idle periods should be of
short duration to prevent a high fluid level build-up in the casing that would reduce rate of flow
into the well bore.
Nowadays, various devices are available to manage the whole process of production
and control the standard pumping characteristics. They act on undesirable conditions such as
Fluid pound.
These systems control the incoming fluid by means of the permanent setting of control
parameters in order to avoid the non-productive pumping and the damage to the pump
components. The shutdown and restarting of the pumping system are automatic, thus
permanently optimizing production time.
When Fluid Pound is caused by a Starved Pump condition, timers and pump-off
devices will not eliminate the problem.
GAS INTERFERENCE :
When the well bottom pressure significantly decreases, in most cases gas bubbles are
released and a gaseous atmosphere appears at the pump intake. The immediate
consequence is a lower pump performance since part of its chamber is filled with gas when
working.
GAS POUND :
If there is an increase of incoming gas, a Gas Pound situation can occur. This is an
undesirable situation that, although is not as serious as the fluid pound, can also damage the
unit.
Under this situation, it is advisable to use well controllers to optimize production and
avoid damage to pump components. It is also advisable to use special parts for gas pumping,
such as gas lock preventer devices.
E-3
CATALOG 2012.05
Bolland
GAS LOCK :
If gas entering the pump increases, the fluid production can be stopped. If this condition
occurs, the maximum gas pressure at the downstroke is not enough to open the traveling
valve, and also, the pressure inside the pump is not low enough to open the stationary valve in
the upstroke. Therefore, inside the pump, gas is compressed and expanded in every stroke,
avoiding fluid to be pumped.
Special devices used in the pump can prevent this problem. It is advisable to use
controllers that stop pumping until pressure in the annulus allows the opening of the stationary
valve and pumping starts again. If the conditions to start and keep pumping are not met, the
controller stops pumping to prevent failures.
If sand enters the well bore with produced fluid, numerous problems can occur. Not
only the entire subsurface equipment design must be considered to reduce the frequency of
sand problems, but practical experience in the particular locale as well.
To analyze possible solutions, it is necessary to know the oil viscosity, grain size and
quantity of sand per unit of volume.
In these cases, it is advisable to set the pump above the casing perforations to allow
sand to settle while going upwards through the tubing and below the pump intake.
Plunger clearances shall depend on the size of the sand grain and the fluid viscosity.
Experience shows that a small clearance between the barrel and the plunger avoids the
incoming of sand grains bigger than the difference between radios. However, this is not
possible when the fluid viscosity requires wider clearance. In this case, it is necessary to
choose the clearance that allows the passage of sand and the resulting slippage must be
limited with a longer plunger.
In the case of stationary barrel pumps, it is advisable to replace the rod guide by a gas
lock preventer device which avoids, in the upstroke and in the case of shutdown of the
pumping unit, the entrance of sand inside the barrel.
Extensions with bigger diameters than the barrel diameters are also used in pumps.
The length of the extensions, barrels and plunger are estimated to allow the plunger to
displace outside the barrel in each stroke, cleaning the area and avoiding stuck conditions due
to sand and scaling.
Many wells contain produced fluids that cause scale deposits in areas where agitation
or pressure drops occur. Usually this problem is best resolved by the use of chemical
treatment that prevents, reduces or dissolves the deposit.
E-4
CATALOG 2012.05
Bolland
CORROSION :
Corrosion is a serious problem for oil production, especially if artificial lifting methods
are needed.
After some years of production, productive wells start to increase their water content
due to natural causes or injection for secondary recovery and, consequently, the first corrosion
signs appear.
New technologies have been developed to increase well depths and this development
has made it more difficult to control corrosion through chemical methods or corrosion-resistant
materials that bear the tension borne by the pumps at these new depths .
When corrosion is present, it is not possible to completely eliminate it, but action must
be taken to reduce damage to acceptable technical-economic levels. In general, corrosion
depends on Ph level and water content percentage. There are also some other factors to be
considered, such as well bottom temperature and possible contamination with acid gases (i.e.
CO2 and/or H2S).
When facing a corrosive well, it is necessary to consider first the development of an
inhibitor application program.
In sucker rod systems, the subsurface pump is one of the most difficult parts to be
protected by means of inhibitors; even if its outer surface may be protected with the chemicals,
its inside presents problems associated with fluid flow speed, abrasion and cavitation, which
negatively affect the chemical performance.
Therefore, if it is difficult for the inhibitor to access the affected areas and a long service
life is necessary, it is advisable to use materials most likely to resist the corrosion and abrasive
action of an oil well environment.
F-1
CATALOG 2012.05
Bolland
BARRELS
Our barrels go through strict controls from the reception of raw materials to the
packaging inspection. Quality control is made to every manufactured part, guaranteeing 100%
compliance with international quality standards. Barrels are manufactured with the most
updated techniques of precision honing and polishing to obtain a mirror finished inside surface.
LAC: Chrome plated brass tube. Properties: Minimum thickness 0.076 mm (0.003 in.),
hardness 67 / 71 HRC on a base material of minimum yield strength 345 Mpa (50 ksi).
Applications: To be used under conditions of HIGH abrasion and corrosion.
F-2
CATALOG 2012.05
Bolland
PLUNGERS
The friction between barrel and plunger is a very important factor to consider when
designing pumps as it determines their service life. The correct selection of the clearance, as
to allow the formation of a lubricant layer between the surfaces, will result in an excellent
performance of the unit. Therefore, precision and surface finishing determine the plunger
reliability.
There are plungers manufactured with different materials to be adapted to the different
fluids and applications, but, in general, the most commonly used plungers are those with an
outside coating. Adherence, thickness, homogeneity and hardness of this coating determine
their service life.
The most commonly used materials and their properties are the following:
Plungers are manufactured in all API Standard sizes, with pin or box threads and
clearance as required by customer.
F-3
CATALOG 2012.05
Bolland
TM
LUBRI - PLUNGER
The special design of sealing rings prevents the spillage of fluid between plunger and
barrel, both in the upstroke and in the downstroke, achieving maximum pumping performance.
The rings have two functions: while they sweep the barrel surface preventing the
passage of any particle between piston and barrel, the special lubricant contained in the
chamber between the rings lubricates the barrel in every stroke, thus reducing pump wear and
stuck against the barrel.
These plungers are ideal in solid drag conditions and produce more fluid at lower
speeds, decreasing, consequently, wear of the whole pumping system.
VALVES
Pump valves are made of balls and seats and they are a key component when working
under high hydraulic pressure due to depth. Only a perfect design and a correct selection of
the material can guarantee their service life.
Bolland offers the following materials and qualities to be used in assemblies of the
same or combined materials:
HD: Alloy steel. Characteristics: Minimum yield strength: 580 MPa (84 ksi). Applications:
MEDIUM corrosion and HIGH mechanical requirements.
LA: Naval brass. Characteristics: Hardness: 43 to 55 HRA. Minimum yield strength: 275 MPa
(40 ksi). Applications: HIGH corrosion.
SS: Stainless steel. Characteristics: Hardness: 74 HRB to 23 HRC. Minimum yield strength:
240 MPa (35 ksi). Applications:
HIGH corrosion.
DENOMINATION
AND SELECTION
BOLLAND Y CA. S.A. KEEPS THE RIGHT TO MODIFY TECHNICAL SPECIFICATIONS WITHOUT
PREVIOUS NOTIFICATION.
G-1
CATALOG 2012.05
Bolland
1 - The different types of Subsurface Sucker Rod Pumps are identified in compliance with
specification API 11AX as follows:
2 - Complete pump designation includes: Nominal tubing size, basic pump bore, type of pump
including type of barrel and location and type of seating assembly, barrel length in feet,
nominal plunger length in feet, length of every extension in whole feet when required.
See chart on next page for the meaning of each part of the code.
G-2
CATALOG 2012.05
Bolland
XX - XXX X X X X X-X-X-X
15 ( 1,90 48,3 mm )
20 ( 2 3/8 60,3 mm )
Tubing size 25 ( 2 7/8 73,0 mm )
30 ( 3 1/2 88,9 mm )
40 ( 4 1/2 114,3 mm )
H : heavy wall
Type of barrel W : thin wall
X : heavy wall, thin wall
thread configuration
Location A : top
of seating B : bottom
assembly T : bottom, traveling barrel
Example: A 1 in. bore rod type pump with a 16 ft steel chrome heavy wall barrel, a 4 ft
spray metal plunger, a 2 ft upper extension, a 2 ft lower extension and a bottom cup type
seating assembly for operation in 2 7/8 in. tubing.
Would be designated as follows: 25-175 RHBC-16-4-2-2 Barrel ACI - Plunger ML, clearance
3 - Seats Tungsten Carbide and balls Titanium Carbide - Fittings Regular.
G-3
CATALOG 2012.05
Bolland
N11
N14 S11
R11
S12
S13
S14
S21
S15
C12
C31
P12
C14 C14
V11 V11
N11
S22
S11
S12
N12 S13
S14
S16
G-5
CATALOG 2012.05
Bolland
P11
C33 C33
N11
S22
S11
S12
S13
N12
S14
S16
G-6
CATALOG 2012.05
Bolland
N11
N14 S11
R11
S12
S13
S14
S21
S15
C12
P12
C14 C14
V11
V11
N11
S22
S11
S12
S13
N12
S14
S16
G-8
CATALOG 2012.05
Bolland
P12
C14 C14
V11
V11
N11
S22 S11
S12
S13
N12
S14
S16
G-9
CATALOG 2012.05
Bolland
T11
P11
C33 C33
N11
S22
S11
S12
S13
N12
S14
S16
G-10
CATALOG 2012.05
Bolland
C34
C11
TUBING, HEAVY WALL BARREL PUMP
V11
( TH ) OPCIONAL
N21
P21
C34 S22
ALTERNATIVA
N13
N12
ALTERNATIVA
G-11
CATALOG 2012.05
Bolland
C11
V11
HOLLOW VALVE ROD PUMP,
HEAVY WALL BARREL, TOP ANCHOR
C33
( RHACP )
G11
N11
C13
C31 V11
P12
C14
V11
B22
G-12
CATALOG 2012.05
Bolland
C11
V11
HOLLOW VALVE ROD PUMP,
HEAVY WALL BARREL, BOTTOM ANCHOR
C33
( RHBCP )
G11
N11
S11
S12
S13
S14
S16
G-13
CATALOG 2012.05
Bolland
C11
V11
HOLLOW VALVE ROD PUMP,
THIN WALL BARREL, TOP ANCHOR
C33
( RWACP )
G11
N11
TUBING SIZE 2 7/8 S11
T11
S12
PUMP 25-200
S13
B11 Barrel, thin wall B11-200
B22 Bushing, barrel cage B22-25 S14
C11 Cage, top open C11-25 S15
C13 Cage, closed plunger C13-200
C14 Cage, closed barrel C14-25 C32
C32 Coupling, lower hvrp C32-200T
C33 Coupling, upper hvrp C33-175T
G11 Guide, pull tube hvrp G11-175T
N11 Nipple, seating, cup N11-25
P12 Plug, seat P12-200
P21 Plunger, one piece P21-200
S11 Seating mandrel, cup S11-25T B11
S12 Seating cup S12-25TC
S13 Seating cup ring S13-25T
S14 Seating cup nut S14-25T P21
S15 Seating cup bushing S15-25T
T11 Tube, pull T11-200
V11 Valve (traveling, lower) V11-200
V11 Valve (traveling, upper) V11-225
V11 Valve (standing) V11-225
C13
V11
P12
C14
V11
B22
G-14
CATALOG 2012.05
Bolland
C11
V11
HOLLOW VALVE ROD PUMP,
THIN WALL BARREL, BOTTOM ANCHOR
C33
( RWBCP )
G11
P12
C14
V11
N11
S11
S12
S13
S14
S16
G-15
CATALOG 2012.05
Bolland
CIRCLE A PUMPS
1 - The different types of Subsurface Sucker Rod Circle A Pumps are identified as follows:
Metal PlungerPump
Type of Pump
2 - Complete pump designation includes: Nominal tubing size, basic pump bore, type of pump
including type of barrel and location and type of seating assembly, barrel length in feet,
nominal plunger length in feet, length of upper extension in whole feet when required,
length of lower extension in whole feet when required.
See chart on next page for the meaning of each part of the code.
G-17
CATALOG 2012.05
Bolland
XX - XXX X X X - X - XX X - X - X - X
15 ( 1,90 48,3 mm )
20 ( 2 3/8 60,3 mm )
Tubing size 25 ( 2 7/8 73,0 mm )
30 ( 3 1/2 88,9 mm )
40 ( 4 1/2 114,3 mm )
R : rod
Type of pump AT : circle A tubing
AR: circle A rod
Location A : top
of seating B : bottom
assembly T : bottom, traveling barrel
Example: A 1 in. bore rod type circle A two stage pump with a 16 ft steel chrome heavy wall
barrel, a 4 ft spray metal plunger, a 2 ft upper extension, a 2 ft lower extension and a bottom
friction type seating assembly for operation in 2 7/8 in. tubing.
Would be designated as follows: 25-175 ARHB-F-TS 16-4-2-2 Barrel ACI - Plunger ML,
clearance 3 - Seats and balls Staralloy - Fittings Regular.
G-18
CATALOG 2012.05
Bolland
B21
R11
S28
C31
B25
C18
V12
V12R
P13
G-19
CATALOG 2012.05
Bolland
B21
C20
R11
S41
S28
TUBING SIZE 2 7/8 2 7/8" 3 1/2" R13
R14
PUMP 25-150 25-175 30-225
S27
B12 Barrel, heavy wall B12-150 B12-175 B12-225
B21 Bushing, valve rod B21-20 B21-25 N16 B26
B21-30V
B25 Cage body, insert type B25-25 B25-25 B25-30 C31
B26 Cage, top plunger B26-150 B26-175 B26-225
C18 Insert type guide (traveling) C18-125 C18-150 C18-200
C18 Insert type guide (standing) C18-200 C18-200 C18-250
C20 Cage, annular valve C20-25 C20-25 C20-30
C31 Coupling, extension C31-150 C31-175 C31-225 P25
N16 Nipple, seating, friction N16-25 N16-25 N16-30
P13 Plug, seat (barrel) P13-225 P13-225 P13-275
P13 Plug, seat (plunger) P13-150 P13-175 P13-225
P25 Cage plain plunger P25-150 P25-175 P25-225
C18
R11 Rod, valve R11-20 R11-25 R11-30V
R13 Friction ring R13A25 R13A25 R13A30 V12
R14 O-ring, friction mandrel R14-25 R14-25 R14-30 V12R
S27 Seating, friction mandrel S27-25 S27-25 S27-30 P13
S28 No-go seat S28-25 S28-25 S28-30
B12
S41 Spool ring valve S41-200 S41-200 S41-250
V12 Valve (traveling) V12-125 V12-150 V12-200
V12 Valve (standing) V12-200 V12-200 V12-250
V12R O-ring, valve (traveling) V12R125 V12R150 V12R200
V12R O-ring, valve (standing) V12R200 V12R200 V12R250
C31
B25
C18
V12
V12R
P13
G-20
CATALOG 2012.05
Bolland
B21
G11
R11
S28
TUBING SIZE 2 7/8 3 1/2"
R13
R14
PUMP 25-200 30-250
B11 Barrel, thin wall B11-200 B11-250 S27
B21 Bushing, valve rod B21-25 B26
B21-30V N16
B25 Cage body, insert type B25-25 B25-30
B26 Cage, top plunger B26-200 B26-250
C18 Insert type guide (traveling) C18-175 C18-225
C18 Insert type guide (standing) C18-200 C18-250
G11 Guide, valve rod G11-25A G11-30A
N16 Nipple, seating, friction N16-25 N16-30 P25
P13 Plug, seat (barrel) P13-225 P13-275
P13 Plug, seat (plunger) P13-200 P13-250
P25 Cage plain plunger P25-200 P25-250
R11 Rod, valve R11-25 R11-30V
C18
R13 Friction ring R13A25 R13A30
R14 O-ring, friction mandrel R14-25 R14-30 V12
V12R
S27 Seating, friction mandrel S27-25 S27-30
S28 No-go seat S28-25 S28-30 P13
V12 Valve (traveling) V12-175 V12-225
V12 Valve (standing) V12-200 V12-250 B11
B25
C18
V12
V12R
P13
G-21
CATALOG 2012.05
Bolland
B21
C20
R11
S41
S28
TUBING SIZE 2 7/8 3 1/2"
R13
R14
PUMP 25-200 30-250
B11 Barrel, thin wall B11-200 B11-250 S27
B21 Bushing, valve rod B21-25 B26
B21-30V N16
B25 Cage body, insert type B25-25 B25-30
B26 Cage, top plunger B26-200 B26-250
C18 Insert type guide (traveling) C18-175 C18-225
C18 Insert type guide (standing) C18-200 C18-250
C20 Cage, annular valve C20-25 C20-30
N16 Nipple, seating, friction N16-25 N16-30 P25
P13 Plug, seat (barrel) P13-225 P13-275
P13 Plug, seat (plunger) P13-200 P13-250
P25 Cage plain plunger P25-200 P25-250
R11 Rod, valve R11-25 R11-30V
C18
R13 Friction ring R13A25 R13A30
R14 O-ring, friction mandrel R14-25 R14-30 V12
V12R
S27 Seating, friction mandrel S27-25 S27-30
S28 No-go seat S28-25 S28-30 P13
S41 Spool ring valve S41-200 S41-250
V12 Valve (traveling) V12-175 V12-225 B11
B25
C18
V12
V12R
P13
G-22
CATALOG 2012.05
Bolland
B21
ROD, CIRCLE A, STATIONARY HEAVY WALL BARREL,
BOTTOM FRICTION OR MECHANICAL ANCHOR PUMP
( ARHB-F )
( ARHB-M )
G11
R11
C21
B26
C31
P25
C18
V12
V12R
P13
B12
B25
C18
C31
V12
V12R
AAI B25
S22
C18
V12 V12R
B21
ROD, CIRCLE A, STATIONARY HEAVY WALL BARREL,
BOTTOM FRICTION OR MECHANICAL ANCHOR,
TWO STAGE PUMP
( ARHB-F-TS )
( ARHB-M-TS )
C20
R11
S41
C23
C31
B26
P25
C18
V12
V12R
P13
B12
B25
C18
C31
V12
V12R
AAI B25
S22
C18
V12 V12R
B25
C18
V12
V12R
AAI B25
S22
C18
V12 V12R
B25
C18
V12
V12R
AAI B25
S22
C18
V12 V12R
C11
C31
C16
V11
TUBING SIZE 2 7/8 3 1/2"
P11
C33
X12
R13
R14
M11
N15
G-29
CATALOG 2012.05
Bolland
C11
C16
V11
TUBING SIZE 2 3/8 2 7/8 3 1/2"
P11
C33
X12
R13
R14
M11
N15
G-30
CATALOG 2012.05
Bolland
C34
C35
TUBING SIZE 2 7/8 3 1/2" 4 1/2"
N15
N12
ALTERNATIVA
PS
CATALOG 2012.05
Bolland
PARTS SECTION
H
CATALOG 2012.05
Bolland
BARRELS
H-1
CATALOG 2012.05
Bolland
BUSHINGS
I-1
CATALOG 2012.05
Bolland
1 Outside diameter reduced to avoid its passage through the top coupling of the 2-3/4 heavy wall,
box thread barrel.
B
BUSHING, SEAT, BARREL CAGE, WITH LOCK NUT
B 22 - MT
ASSEMBLY
REGULAR B22-30MT
A PARTS
A REGULAR B22-30MT1
B REGULAR P12-275T
B
BUSHING, SEAT, BARREL CAGE, TUBING PUMP
B 22 / B 22 - T
ITEM A ITEM B NIPPLE STRAINER
API TUBING REGULAR HEAVY DUTY REGULAR CONNECT. 1- 1/2
A 2- 7/8 B22-278 B22-278HD NO TIENE YES
3- 1/2 B22-325N278 B22-325N278HD B22-325T YES
3- 1/2 B22-325N312 B22-325N312HD B22-325T NO
3- 1/2 B22-375N312 B22-375N312HD B22-375T NO
BUSHING,
TUBING PUMP
BR
FROM THREAD TO THREAD REGULAR
LINE PIPE 1-1/4 NOM. BOX LINE PIPE 1 NOM. PIN BR114H1M
LINE PIPE 2 NOM. PINM LINE PIPE 1- 1/2 NOM. BOX BR2M112H
A.P.I. TUBING E.U. 2- 7/8 NOM. PIN 2- 11 NPT BOX BR278M2H
A.P.I. TUBING E.U. 2- 7/8 NOM. PIN A.P.I. TUBING E.U. 2- 3/8 NOM. PIN BR278M238M
A.P.I. TUBING E.U. 2- 7/8 NOM. PIN A.P.I. TUBING E.U. 2- 3/8 NOM. BOX BR278M238H
A.P.I. TUBING E.U. 2- 7/8 NOM. PIN A.P.I. TUBING E.U. 2- 7/8 NOM. PIN BR278M278M
A.P.I. TUBING E.U. 2- 7/8 NOM. PIN A.P.I. TUBING E.U. 2- 7/8 NOM. BOX BR278M278H
A.P.I. TUBING E.U. 2- 7/8 NOM. BOX A.P.I. TUBING E.U. 2- 3/8 NOM. PIN BR278H238M
A.P.I. TUBING E.U. 2- 7/8 NOM. BOX A.P.I. TUBING E.U. 2- 3/8 NOM. BOX BR278H238H
A.P.I. TUBING E.U. 3- 1/2 NOM. PIN A.P.I. TUBING E.U. 2- 7/8 NOM. PIN BR312M278M
A.P.I. TUBING E.U. 3- 1/2 NOM. PIN A.P.I. TUBING E.U. 2- 7/8 NOM. BOX BR312M278H
A.P.I. TUBING E.U. 3- 1/2 NOM. BOX A.P.I. TUBING E.U. 2- 3/8 NOM. BOX BR312H238H
A.P.I. TUBING E.U. 3- 1/2 NOM. BOX A.P.I. TUBING E.U. 2- 7/8 NOM. PIN BR312H278M
A.P.I. TUBING E.U. 3- 1/2 NOM. BOX A.P.I. TUBING E.U. 2- 7/8 NOM. BOX BR312H278H
1- 1/4- 11 NPT PIN A.P.I. TUBING E.U. 2- 3/8 NOM. PIN BR114M238M
2,0870-16NS-3 BOX 1,5730-16NS-3 BOX BR2087H1573H
2,8750-16NS3 PIN A.P.I. TUBING E.U. 2- 7/8 NOM. BOX BR2875M278H
3,3825-11 NS3 PIN A.P.I. TUBING E.U. 3- 1/2 NOM. PIN BRB11325M312M
3,3825-11 NS3 PIN A.P.I. TUBING E.U. 2- 7/8 NOM. PIN BR3382M278M
3,3825-11 NS3 PIN A.P.I. TUBING E.U. 3- 1/2 NOM.BOX BR3382M312H
3,3825-11 NS3 BOX A.P.I. TUBING E.U. 3- 1/2 NOM. PIN BR3382H312M
3,3825-11 NS3 BOX A.P.I. TUBING E.U. 3- 1/2 NOM. BOX BR3382H312H
BUSHING,
TUBING PUMP
BR
FROM THREAD TO THREAD BRASS
3,2380-11 NS3 BOX A.P.I. TUBING E.U. 2- 7/8 NOM. BOX BR3238H278HLA
CAGES
K-1
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
K-3
CATALOG 2012.05
Bolland
ASSEMBLY
VALVE ROD SIZE 7/8 7/8 7/8 1- 1/16 1- 1/16
REGULAR C12-150-25M C12-175M C12-200M C12-225M C12-250M
MONEL C12-150-25MMO C12-175MMO C12-200MMO C12-225MMO C12-250MMO
BRASS C12-150-25MLA C12-175MLA C12-200MLA C12-225MLA C12-250MLA
STAINLESS STEEL C12-150-25MSS C12-175MSS C12-200MSS C12-225MSS C12-250MSS
ITEM MATERIAL PARTS
REGULAR C12-150-25M1 C12-175M1 C12-200M1 C12-225M1 C12-250M1
A MONEL C12-150-25M1MO C12-175M1MO C12-200M1MO C12-225M1MO C12-250M1MO
BRASS C12-150-25M1LA C12-175M1LA C12-200M1LA C12-225M1LA C12-250M1LA
STAINLESS C12-150-25M1SS C12-175M1SS C12-200M1SS C12-225M1SS C12-250M1SS
REGULAR C12-150-25M2 C12-25M2 C12-25M2 C12-30M2 C12-30M2
B MONEL C12-150-25M2MO C12-25M2MO C12-25M2MO C12-30M2MO C12-30M2MO
BASS C12-150-25M2LA C12-25M2LA C12-25M2LA C12-30M2LA C12-30M2LA
STAINLESS C12-150-25M2SS C12-25M2SS C12-25M2SS C12-30M2SS C12-30M2SS
Also available with left hand thread. In such case, add letter I at the end of the code.
ASSEMBLY
VALVE ROD SIZE 7/8 7/8 7/8 1- 1/16 1- 1/16
REGULAR C12-150-25CM C12-175CM C12-200CM C12-225CM C12-250CM
MONEL C12-150-25CMMO C12-175CMMO C12-200CMMO C12-225CMMO C12-250CMMO
BRASS C12-150-25CMLA C12-175CMLA C12-200CMLA C12-225CMLA C12-250CMLA
STAINLESS STEEL C12-150-25CMSS C12-175CMSS C12-200CMSS C12-225CMSS C12-250CMSS
ITEM MATERIAL PARTS
REGULAR C12-150-25CM1 C12-175CM1 C12-200CM1 C12-225CM1 C12-250CM1
A MONEL C12-150-25CM1MO C12-175CM1MO C12-200CM1MO C12-225CM1MO C12-250CM1MO
BRASS C12-150-25CM1LA C12-175CM1LA C12-200CM1LA C12-225CM1LA C12-250CM1LA
STAINLESS C12-150-25CM1SS C12-175CM1SS C12-200CM1SS C12-225CM1SS C12-250CM1SS
REGULAR C12-150-25M2 C12-25M2 C12-25M2 C12-30M2 C12-30M2
B MONEL C12-150-25M2MO C12-25M2MO C12-25M2MO C12-30M2MO C12-30M2MO
BRASS C12-150-25M2LA C12-25M2LA C12-25M2LA C12-30M2LA C12-30M2LA
STAINLESS C12-150-25M2SS C12-25M2SS C12-25M2SS C12-30M2SS C12-30M2SS
Also available with left hand thread. In such case, add letter I at the end of the code.
USED AS TOP PLUNGER CONNECTOR WITHOUT VALVE SEAT IN CASES OF EXTREME SOLICITATION,
TO PREVENT THE VALVE ROD BREAKAGE IN THE THREAD SECTION.
K-8
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
K-9
CATALOG 2012.05
Bolland
CALIFORNIA BALL
C 13 - L C 13 - LC
HEAT TREATED HEAT TREATED
C13-325HTL C13-325HTLC
C13-375HTL C13-375HTLC
BIG SIZE CAGES FOR VISCOUS FLUIDS WITH MORE CLEARANCE IN BALL GUIDES.
BIG SIZE CAGES FOR VISCOUS FLUIDS WITH MORE CLEARANCE IN BALL GUIDES.
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
K-10
CATALOG 2012.05
Bolland
ASSEMBLY
REGULAR C13-225AP C13-250AP C13-275AP C13-325AP
HEAT TREATED C13-225HTP C13-250HTP C13-275HTP C13.325HTP
C MONEL C13-225MOP C13-250MOP C13-275MOP C13-325MOP
BRASS C13-225LAP C13-250LAP C13-275LAP C13-325LAP
STAINLESS STEEL C13-225SSP C13-250SSP C13-275SSP C13-325SSP
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-11
CATALOG 2012.05
Bolland
PARTS
ASSEMBLY
REGULAR C13-225APC C13-250APC C13-275APC C13-325APC
HEAT TREATED C13-225HTPC C13-250HTPC C13-275HTPC C13-325HTPC
C
MONEL C13-225MOPC C13-250MOPC C13-275MOPC C13-325MOPC
BRASS C13-225LAPC C13-250LAPC C13-275LAPC C13-325LAPC
STAINLESS STEEL C13-225SSPC C13-250SSPC C13-275SSPC C13-325SSPC
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-12
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
PARTS
ASSEMBLY
REGULAR C13-225APD C13-250APD C13-275APD C13-325APD
HEAT TREATED C13-225HTPD C13-250HTPD C13-275HTPD C13-325HTPD
C
MONEL C13-225MOPD C13-250MOPD C13-275MOPD C13-325MOPD
BRASS C13-225LAPD C13-250LAPD C13-275LAPD C13-325LAPD
STAINLESS C13-225SSPD C13-250SSPD C13-275SSPD C13-325SSPD
PARTS
USED IN WELLS WITH SAND OR SOLIDS. MUST BE INSTALLED IN COMBINATION WITH ANY VERSION OF THE C13
STANDARD CAGE. CAUTION IN GASSY WELLS BECAUSE IT INCREASES THE UNSWEPT VOLUME.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-14
CATALOG 2012.05
Bolland
PARTS
ASSEMBLY
REGULAR C13-225APDC C13-250APDC C13-275APDC C13-325APDC
HEAT TREATED C13-225HTPDC C13-250HTPDC C13-275HTPDC C13-325HTPDC
C
MONEL C13-225MOPDC C13-250MOPDC C13-275MOPDC C13-325MOPDC
BRASS C13-225LAPDC C13-250LAPDC C13-275LAPDC C13-325LAPDC
STAINLESS STEEL C13-225SSPDC C13-250SSPDC C13-275SSPDC C13-325SSPDC
PARTS
USED IN WELLS WITH SAND OR SOLIDS. MUST BE INSTALLED IN COMBINATION WITH ANY VERSION OF THE C13
STANDARD CAGE. CAUTION IN GASSY WELLS BECAUSE IT INCREASES THE UNSWEPT VOLUME.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-15
CATALOG 2012.05
Bolland
A ASSEMBLY
PARTS
B A REGULAR C13-125A4 C13-150A4 C13-175A4 C13-200A4
ASSEMBLY
D
HEAT TREATED C13-225ABHT C13-250ABHT C13-275ABHT
PARTS
USED IN COMBINATION WITH THE DIFFERENT VERSIONS OF GAS LOCK PREVENTER CAGES C14-AB AND C16-AB.
PREVENTS THE GAS LOCK BY FORCING THE OPENING OF THE TRAVELING VALVE IN A MECHANICAL WAY.
K-16
CATALOG 2012.05
Bolland
PARTS
REGULAR C13-150A4 C13-175A4 C13-200A4
A NICKEL PLT. C13-150SS4 C13-175SS4 C13-200SS4
A
MONEL C13-150MO4 C13-175MO4 C13-200MO4
STAINLESS C13-150SS4 C13-175SS4 C13-200SS4
ASSEMBLY
REGULAR C13-225ABGD C13-250ABGD C13-275ABGD
D
NICKEL PLATED C13-225ABGDNQ C13-250ABGDNQ C13-275ABGDNQ
MONEL C13-225ABGDMO C13-250ABGDMO C13-275ABGDMO
STAINLESS STEEL C13-225ABGDSS C13-250ABGDSS C13-275ABGDSS
PARTS
REGULAR C13-225A4 C13-250A4 C13-275A4
A NICKEL PLT. C13-225SS4 C13-250SS4 C13-275SS4
MONEL C13-225MO4 C13-250MO4 C13-275MO4
STAINLESS C13-225SS4 C13-250SS4 C13-275SS4
USED IN COMBINATION WITH THE DIFFERENT VERSIONS OF GAS LOCK PREVENTER CAGES C14-AB AND C16-AB.
PREVENTS THE GAS LOCK BY FORCING THE OPENING OF THE TRAVELING VALVE IN A MECHANICAL WAY.
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
K-17
CATALOG 2012.05
Bolland
PREVENTS PUMP BLOCKAGE DUE TO THE PRESENCE OF GAS, BOTH IN ITS SHUT POSITION (BY THE COMPRESSION
OF THE GAS) AS IN ITS OPEN POSITION (BY THE FLOWING OF A HIGH AMOUNT OF GAS).
AT THE BEGINNING OF THE DOWNSTROKE, ITEM D TENDS TO STOP AGAINST THE BARREL AND ITEM C , CONNECTED
TO IT, OPENS THE VALVE BY PUSHING THE BALL.
IN THE UPSTROKE, ITEM D TENDS TO STOP AGAINST THE BARREL AND ITEM C CAUSES A STRANGULATION WITH
THE VALVE SEAT, HELPING TO THE CLOSURE OF THE VALVE.
K-18
CATALOG 2012.05
Bolland
C
ASSEMBLY
REGULAR C13-225AG1RB C13-250AG1RB C13-275AG1RB C13-325AG1RB
MONEL C13-225AG1RBMO C13-250AG1RBMO C13-275AG1RBMO C13-325AG1RBMO
D C13-225AG1RBSS C13-250AG1RBSS C13-275AG1RBSS C13-325AG1RBSS
STAINLESS
PARTS
REG. C13-225AP C13-250AP C13-275AP C13-325HTPC
A MONEL C13-225MOP C13-250MOP C13-275MOP C13-325MOPC
STAINL. C13-225SSP C13-250SSP C13-275SSP C13-325SSPC
REG. C13-226AG1 C13-251AG1 C13-276AG1 C13-326AG1
B MONEL C13-226AG1MO C13-251AG1MO C13-276AG1MO C13-326AG1MO
STAINL. C13-226AG1SS C13-251AG1SS C13-276AG1SS C13-326AG1SS
REG. C13-227AG1 C13-252AG1 C13-277AG1 C13-327AG1
C MONEL C13-227AG1MO C13-252AG1MO C13-277AG1MO C13-327AG1MO
STAINL. C13-227AG1SS C13-252AG1SS C13-277AG1SS C13-327AG1SS
REG. C13-228AG1RB C13-253AG1RB C13-278AG1RB C13-328AG1RB
D MONEL C13-228AG1RBQ C13-253AG1RBQ C13-278AG1RBQ C13-328AG1RBQ
STAINL. C13-228AG1RBSS C13-253AG1RBSS C13-278AG1RBSS C13-328AG1RBSS
PREVENTS PUMP BLOCKAGE DUE TO THE PRESENCE OF GAS, BOTH IN ITS SHUT POSITION (BY THE COMPRESSIO0N
OF THE GAS) AS IN ITS OPEN POSITION (BY THE FLOWING OF A HIGH AMOUNT OF GAS).
AT THE BEGINNING OF THE DOWNSTROKE, ITEM D TENDS TO STOP AGAINST THE BARREL AND ITEM C , CONNECTED
TO IT, OPENS THE VALVE BY PUSHING THE BALL.
IN THE UPSTROKE, ITEM D TENDS TO STOP AGAINST THE BARREL AND ITEM C CAUSES A STRANGULATION WITH
THE VALVE SEAT, HELPING TO THE CLOSURE OF THE VALVE.
THE SOFT RINGS INCREASE THE ADHERENCE AGAINST THE BARREL AND PROTECT AGAINST WEAR BOTH THE
PLUNGER OF THE VALVE AND THE BARREL.
K-19
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
1 ASSEMBLY
REGULAR C14-20-125AP C14-20AP C14-25AP C14-30AP
HEAT TREATED C14-20-125HTP C14-20HTP C14-25HTP C14-30HTP
MONEL C14-20-125MOP C14-20MOP C14-25MOP C14-30MOP
BRASS C14-20-125LAP C14-20LAP C14-25LAP C14-30LAP
STAINLESS ST. C14-20-125SSP C14-20SSP C14-25SSP C14-30SSP
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-21
CATALOG 2012.05
Bolland
1 ASSEMBLY
REGULAR C14-20-125APC C14-20APC C14-25APC C14-30APC
HEAT TREATED C14-20-125HTPC C14-20HTPC C14-25HTPC C14-30HTPC
MONEL C14-20-125MOPC C14-20MOPC C14-25MOPC C14-30MOPC
BRASS C14-20-125LAPC C14-20LAPC C14-25LAPC C14-30LAPC
STAINLESS ST. C14-20-125SSPC C14-20SSPC C14-25SSPC C14-30SSPC
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-22
CATALOG 2012.05
Bolland
B SOLE C14-25MPC2
B
REGULAR C14-25MPC3
C HEAT TREAT. C14-25MPC3HT
A MONEL C14-25MPC3MO
REGULAR C14-25MPC4
D HEAT TREAT. C14-25MPC4
MONEL C14-25MPC4MO
REGULAR C14-25MPC5
C E HEAT TREAT. C14-25MPC5HT
MONEL C14-25MPC5MO
FOR THEIR RESPECTIVE COMPONENTS, SEE PART C13-PD OF THIS SAME CHAPTER.
USED IN COMBINATION WITH THE P12-E PLUG REDUCES THE UNSWEPT VOLUME
WHICH PREVENTS PUMP BLOCKAGE IN GASSY WELLS.
PARTS PARTS
PARTS
A SOLE C13-175H1 C13-225H1
D
B SOLE C13-175A2 C13-225A2
C REGULAR C13-175X3 C13-225X3
HEAT TR. C13-175X3HT C13-225X3HT
B D REGULAR C14-20A4B C14-25A4B125 C14-25A4B150
HEAT TR. C14-20A4BHT C14-25A4B125HT C14-25A4B150HT
A
ASSEMBLY 3 4
REGULAR C14-25APB175 C14-30APB175 C14-30APB
HEAT TREATED C14-25APB175HT C14-30APB175HT C14-30APBHT
PARTS
C
A SOLE C13-225H1 C13-250H1
CONNECTED DIRECTLY TO THE HEAVY WALL BARREL, AVOIDS THE USE OF THE C31
EXTENSION COUPLING.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-26
CATALOG 2012.05
Bolland
PARTS
A SOLE C13-175H1C C13-225H1C
D B SOLE C13-175A2 C13-225A2
C REGULAR C13-175X3 C13-225X3
HEAT TR. C13-175X3HT C13-225X3HT
B D REGULAR C14-20A4B C14-25A4B125 C14-25A4B150
HEAT TR. C14-20A4BHT C14-25A4B125HT C14-25A4B150HT
ASSEMBLY 3 4
REGULAR C14-25APB175C C14-30APB175C C14-30APBC
HEAT TREATED C14-25APB175HTC C14-30APB175HTC C14-30APBHTC
C
PARTS
A SOLE C13-225H1C C13-250H1C
CONNECTED DIRECTLY TO THE HEAVY WALL BARREL, AVOIDS THE USE OF THE C31
EXTENSION COUPLING.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-27
CATALOG 2012.05
Bolland
C 14 - AB STELLITE LINED
HEAVY DUTY HEAT TREATED
C 14 - ABGD
1 C14-25AB150HD C14-25AB150HT REGULAR STAINLESS ST.E
2 C14-25AB175HD C14-25AB175HT C14-20ABGD C14-20ABGDSS
C14-30ABHD C14-30ABHT 1 C14-25ABGD150 C14-25ABGD150SS
2 C14-25ABGD175 C14-25ABGD175SS
1 For use with C13-150AB cage.
2 For use with C13-175AB cage or larger. C14-30ABGD C14-30ABGSSD
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
THESE GAS LOCK PREVENTER CAGES USED IN COMBINATION WITH THE DIFFERENT VERSIONS
OF GAS LOCK PREVENTER CAGE C13-AB , AVOID THE GAS LOCK BY FORCING THE OPENING OF
THE TRAVELING VALVE IN A MECHANICAL WAY.
K-28
CATALOG 2012.05
Bolland
USED IN COMBINATION WITH THE DIFFERENT VERSIONS OF GAS LOCK PREVENTER CAGE
C13-AB , AVOIDS THE GAS LOCK BY FORCING THE OPENING OF THE TRAVELING VALVE IN A
MECHANICAL WAY.
K-29
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
B
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
B
CAGE, CLOSED BARREL, TUBING PUMP, PLAIN
C 14 - L
THREAD A THREAD B BALL DIAM. HEAT TREATED
2,8067-12NS-3 3,3825"-11 NS-3 2 1/8" C14-325HTL
THESE CAGES ARE USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , TO PROVIDE THE NECESSARY
LOCK POINT FOR THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
WITH VISCOUS FLUIDS, PROVIDE A BETTER PASSAGE SECTION AT THE STANDING VALVE.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
K-30
CATALOG 2012.05
Bolland
THREAD 2 2,8750"-16NS-3 A.P.I. TUBING E.U. 2 " NOM. A.P.I. TUBING E.U. 3 " NOM. 3,3825"-11 NS-3
THREAD 1 2,8067"-12NS-3
BALL DIAMETER 2"
ASSEMBLY
HEAT TREATED C14-277HTP C14-278HTP C14-312HTP C14-325HTP
MONEL C14-277MOP C14-278MOP C14-312MOP C14-325MOP
PARTS
A SOLE C13-325H1
B SOLE C13-325A2
HEAT TR. C14-325RHT3
C
MONEL C14-325RMO3
HEAT TR. C14-277HT4 C14-278HT4 C14-312HT4 C14-325HT4
D
MONEL C14-277UMO4 C14-278UMO4 C14-312UMO4 C14-325UMO4
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT FOR THE
CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-32
CATALOG 2012.05
Bolland
THREAD 2 2,8750"-16NS-3 A.P.I. TUBING E.U. 2 " NOM. A.P.I. TUBING E.U. 3 " NOM. 3,3825"-11 NS-3
THREAD 1 2,8067"-12NS-3
BALL DIAMETER 2"
ASSEMBLY
A SOLE C13-325H1C
B SOLE C13-325A2
HEAT TR. C14-325RHT3
C
MONEL C14-325RMO3
HEAT TR. C14-277HT4 C14-278HT4 C14-312HT4 C14-325HT4
D
MONEL C14-277UMO4 C14-278UMO4 C14-312UMO4 C14-325UMO4
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT FOR THE
CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-33
CATALOG 2012.05
Bolland
A
CAGE, CLOSED BARREL, TUBING PUMP,
STELLITE LINED, CALIFORNIA BALL
C C 14 - GDC
THREAD A THREAD B THREAD C BALL REGULAR HEAVY DUTY
A.P.I. TUB E.U. 2 N 2,8750-16NS-3 2,1095-11 NS-3 1 1/2" C14-278-277GDC C14-278-277GDCHD
A.P.I. TUB E.U. 2 " N A.P.I. TUB E.U. 2 N 2,1095-11 NS-3 1 1/2" C14-278-278GDC C14-278-278GDCHD
B
CAGE, CLOSED BARREL, TUBING PUMP,
WITH BAR, STELLITE LINED
C 14 - TGD
A
THE UPPER LOCK BAR IMPROVES THE RESISTANCE AGAINST DAMAGE
OF THE ON AND OFF TOOL LOCK.
C
THESE CAGES ARE SUITABLE FOR WELLS WITH A HIGH PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE
BALL.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT FOR THE
CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
K-34
CATALOG 2012.05
Bolland
SUITABLE FOR WELLS WITH A HIGH PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE DIFFERENT VERSIONS OF GAS LOCK PREVENTER CAGES C13-AB , AVOIDS THE
GAS LOCK BY FORCING THE OPENING OF THE TRAVELING VALVE IN A MECHANICAL WAY.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT FOR
THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
K-35
CATALOG 2012.05
Bolland
A SOLE C13-250H1
B SOLE C13-250A2
C REGULAR C14-278-278A3
C MONEL C14-278-278MO3
D REGULAR C14-277TA4 C14-278TA4
1
MONEL C14-277TMO4 C14-278TMO4
SUITABLE FOR WELLS WITH A HIGH PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT
FOR THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE
TUBING DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-36
CATALOG 2012.05
Bolland
A SOLE C13-250H1C
B SOLE C13-250A2
C REGULAR C14-278-278A3
C MONEL C14-278-278MO3
D REGULAR C14-277TA4 C14-278TA4
1
MONEL C14-277TMO4 C14-278TMO4
SUITABLE FOR WELLS WITH A HIGH PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT
FOR THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE
TUBING DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-37
CATALOG 2012.05
Bolland
A B SOLE C13-250A2
C REGULAR C14-278-278A3
MONEL C14-278-278MO3
D REGULAR C14-277ABA4 C14-278ABA4
MONEL C14-277ABMO4 C14-278ABMO4
C
SUITABLE FOR WELLS WITH A HIGH PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE DIFFERENT VERSIONS OF GAS LOCK PREVENTER CAGE C13-AB , AVOIDS THE
GAS LOCK BY FORCING THE OPENING OF THE TRAVELING VALVE IN A MECHANICAL WAY.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT FOR
THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-38
CATALOG 2012.05
Bolland
A B SOLE C13-250A2
C REGULAR C14-278-278A3
MONEL C14-278-278MO3
D REGULAR C14-277ABA4 C14-278ABA4
MONEL C14-277ABMO4 C14-278ABMO4
C
SUITABLE FOR WELLS WITH A HIGH PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE DIFFERENT VERSIONS OF GAS LOCK PREVENTER CAGE C13-AB , AVOIDS THE
GAS LOCK BY FORCING THE OPENING OF THE TRAVELING VALVE IN A MECHANICAL WAY.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT FOR
THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN COMBINATION WITH THE TUBING
DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-39
CATALOG 2012.05
Bolland
2
D
THREAD 3 2,1095"-11 NS-3
THREAD 2 2,8750"-16NS-3 A.P.I. TUBING E.U. 2 " NOM.
THREAD 1 A.P.I. TUBING E.U. 2 " NOM.
BALL DIAMETER 1 11/16"
B
ASSEMBLY
SUITABLE FOR WELLS WITH SAND OR SOLIDS AND A HIGH PERCENTAGE OF WATER
DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE
NECESSARY LOCK POINT FOR THE CONNECTION AND DISCONNECTION OF THE ON
AND OFF TOOL.
F
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN
COMBINATION WITH THE TUBING DRAIN VALVE.
1 LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
.
K-40
CATALOG 2012.05
Bolland
2
D THREAD 3 2,1095"-11 NS-3
THREAD 2 2,8750"-16NS-3 A.P.I. TUBING E.U. 2 " NOM.
THREAD 1 A.P.I. TUBING E.U. 2 " NOM.
BALL DIAMETER 1 1/2"
B
ASSEMBLY
REGULAR C14-278-277DTPC C14-278-278DTPC
A
MONEL C14-278-277DTPCMO C14-278-278DTPCMO
PARTS
SUITABLE FOR WELLS WITH SAND OR SOLIDS AND A HIGH PERCENTAGE OF WATER
DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE
NECESSARY LOCK POINT FOR THE CONNECTION AND DISCONNECTION OF THE ON
AND OFF TOOL.
F THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN
COMBINATION WITH THE TUBING DRAIN VALVE.
1 LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
3
K-41
CATALOG 2012.05
Bolland
2
D
PARTS
C A SOLE C13-250H1 (required 2)
D MONEL C14-278MO4
E MONEL C14-278MO5
E
COMPONENT C HAS CHROME PLATED INTERIOR.
A
SUITABLE FOR WELLS WITH SAND OR SOLIDS, HIGH CORROSION AND WITH A HIGH
PERCENTAGE OF WATER DUE TO THE SMALL SIZE OF THE BALL.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE
NECESSARY LOCK POINT FOR THE CONNECTION AND DISCONNECTION OF THE ON
AND OFF TOOL.
THE PUMP HAS TO BE TAKEN OUT WITH THE TUBING FULL, UNLESS IT IS USED IN
C COMBINATION WITH THE TUBING DRAIN VALVE.
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
1
K-42
CATALOG 2012.05
Bolland
B SOLE C13-225A2
C HEAT TREAT. C14-238HT3
C
MONEL C14-238MO3
HEAT TREAT. C14-238HT4
D
MONEL C14-238MO4
B
CALIFORNIA BALL
C 14 - 238 PC
D
ASSEMBLY
HEAT TREATED C14-238HTPC
MONEL C14-238MOPC
PARTS
A SOLE C13-225H1CM
B SOLE C13-225A2
HEAT TREAT. C14-238HT3
C
MONEL C14-238MO3
HEAT TREAT. C14-238HT4
D
MONEL C14-238MO4
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-43
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
K-44
CATALOG 2012.05
Bolland
ASSEMBLY
REGULAR C15-175AP C15-225AP C15-275AP C15-325AP
HEAT TREATED C15-175HTP C15-225HTP C15-275HTP C15-325HTP
MONEL C15-175MOP C15-225MOP C15-275MOP C15-325MOP
BRASS C15-175LAP C15-225LAP C15-275LAP C15-325LAP
STAINLESS ST. C15-175SSP C15-225SSP C15-275SSP C15-325SSP
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-45
CATALOG 2012.05
Bolland
ASSEMBLY
REGULAR C15-175APC C15-225APC C15-275APC C15-325APC
HEAT TREATED C15-175HTPC C15-225HTPC C15-275HTPC C15-325HTPC
MONEL C15-175MOPC C15-225MOPC C15-275MOPC C15-325MOPC
BRASS C15-175LAPC C15-225LAPC C15-275LAPC C15-325LAPC
STAINLESS ST. C15-175SSPC C15-225SSPC C15-275SSPC C15-325SSPC
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-46
CATALOG 2012.05
Bolland
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
K-47
CATALOG 2012.05
Bolland
PARTS
A
A SOLE C13-175H1 C13-225H1 C13-250H1 C13-325H1
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
PARTS
LONGER CAGE SERVICE LIFE DUE TO THE HARDENED STAINLESS STEEL INSERT GUIDE.
K-49
CATALOG 2012.05
Bolland
C 16 - CE
HEAT TREATED
C16-225CEHT
C16-275CEHT
STELLITE LINED
C 16 - CEGD
REGULAR
C16-225CEGD
C16-275CEGD
LONGER CAGE SERVICE LIFE DUE TO THE STELLITE WELDED HARD GUIDES.
USED IN COMBINATION WITH THE PLUG WITH NOTCH P12-CE , PROVIDES THE NECESSARY LOCK POINT
FOR THE CONNECTION AND DISCONNECTION OF THE ON AND OFF TOOL.
K-50
CATALOG 2012.05
Bolland
C 16 - AB
HEAT TREATED
STELLITE LINED
C16-175ABHT
C 16 - ABGD
C16-225ABHT
REGULAR
C16-275ABHT
C16-175ABGD
C16-225ABGD
C16-275ABGD
THESE GAS LOCK PREVENTER CAGES USED IN COMBINATION WITH THE DIFFERENT VER5IONS
OF GAS LOCK PREVENTER CAGE C13-AB , AVOID THE GAS LOCK BY FORCING THE OPENING OF
THE TRAVELING VALVE IN A MECHANICAL WAY.
K-51
CATALOG 2012.05
Bolland
CONNECTORS - COUPLINGS
L-1
CATALOG 2012.05
Bolland
USED IN COMBINATION WITH THE TOP PLUNGER, COLLET TYPE, LEFT HAND THREAD
CAGE C12 - M I , OFFERS AN AL TERNATIVE POINT TO ROTATE THE PUMP (SEATING)
IN CASES OF DAMAGED LOCKS IN G11 AND B21 PARTS.
L-2
CATALOG 2012.05
Bolland
COUPLING, EXTENSION
C 31
REGULAR BRASS NICKEL PLATED
C31-106-XX C31-106-XXLA C31-106-XXNQ
C31-125-XX C31-125-XXLA C31-125-XXNQ
C31-150-XX C31-150-XXLA C31-150-XXNQ
C31-175-XX C31-175-XXLA C31-175-XXNQ
C31-225-XX C31-225-XXLA C31-225-XXNQ
C31-275-XX
COUPLING, LOWER,
HOLLOW VALVE ROD PUMP
C 32 - T
REGULAR
C32-150T
C32-175T
C32-200T
C32-225T
COUPLING, TUBING
C 34
REGULAR NICKEL PLATED
C34-20 C34-20NQ
C34-25 C34-25NQ
C34-30 C34-30NQ
C34-40 C34-40NQ
COUPLING, BARREL
C 35
REGULAR HEAVY DUTY NICKEL PLATED
C35-20 C35-20HD C35-20NQ
C35-25 C35-25HD C35-25NQ
1 C35-25M1 C35-25M1HD C35-25M1NQ
2 C35-30-278 C35-30-278HD C35-30-278NQ
C35-30 C35-30HD C35-30NQ
3 C35-30M1 C35-30M1HD C35-30M1NQ
C35-35 C35-35HD C35-35NQ
C35-40 C35-40HD C35-40NQ
C35-25M
1 C35-25M2
C35-30M
2 C35-30M2
PREVENTS THE PLUNGER FROM COMING OUT OF THE BARREL, THUS AVOIDING
THE RINGS DAMAGE.
IT IS RECOMMENDED TO USE THIS COUPLING WITH THE ON AND OFF TOOL TO
DISCONNECT THE SUCKER RODS.
M
CATALOG 2012.05
Bolland
NIPPLES
N-1
CATALOG 2012.05
Bolland
NIPPLE, SEATING,
MECHANICAL TOP LOCK
A
N 14
ASSEMBLY
STANDARD N14-20 N14-25 N14-30
B
PARTS
PLUGS
O-1
CATALOG 2012.05
Bolland
PLUG, PULL
P 11
REGULAR HEAVY DUTY HEAT TREATED BRASS STAINLESS ST.
1 P11-106 P11-106HD P11-106HT P11-106LA P11-106SS
2 P11-125-15 P11-125-15HD P11-125-15HT P11-125-15LA P11-125-15SS
3 P11-125 P11-125HD P11-125HT P11-125LA P11-125SS
4 P11-150-20 P11-150-20HD P11-150-20HT P11-150-20LA P11-150-20SS
5 P11-150-25 P11-150-25HD P11-150-25HT P11-150-25LA P11-150-25SS
6 P11-175 P11-175HD P11-175HT P11-175LA P11-175SS
7 P11-200 P11-200HD P11-200HT P11-200LA P11-200SS
8 P11-225 P11-225HD P11-225HT P11-225LA P11-225SS
1 For use with 1-1/16 heavy wall barrel with extension coupling in tubing 20.
2 For use with 1-1/4 thin wall barrel in tubing 15 or 20.
3 For use with 1-1/4 heavy wall barrel with extension coupling in tubing 20.
4 For use with 1-1/2 thin wall barrel in tubing 20.
5 For use with 1-1/2 heavy wall barrel with extension coupling in tubing 25.
6 For use with 1-3/4 heavy wall barrel with extension coupling in tubing 25.
7 For use with 2 thin wall barrel in tubing 25.
8 For use with 2-1/4 heavy wall barrel with extension coupling in tubing 30.
8 For use with 2-1/2 thin wall barrel in tubing 30.
PLUG, SEAT
P 12
REGULAR HEAVY DUTY HEAT TREATED BRASS STAINLESS ST.
P12-106 P12-106HD P12-106HT P12-106LA P12-106SS
P12-125 P12-125HD P12-125HT P12-125LA P12-125SS
P12-150 P12-150HD P12-150HT P12-150LA P12-150SS
P12-175 P12-175HD P12-175HT P12-175LA P12-175SS
P12-200 P12-200HD P12-200HT P12-200LA P12-200SS
P12-225 P12-225HD P12-225HT P12-225LA P12-225SS
P12-250 P12-250HD P12-250HT P12-250LA P12-250SS
P12-275 P12-275HD P12-275HT P12-275LA P12-275SS
O-2
CATALOG 2012.05
Bolland
NOTCHED PLUG
FOR ON AND OFF TOOL LOCK
P 12 - CE
REGULAR HEAVY DUTY MONEL
P12-225CE P12-225CEHD P12-225CEMO
P12-250CE P12-250CEHD P12-250CEMO
P12-275CE P12-275CEHD P12-275CEMO
P12-325CE P12-325CEHD P12-325CEMO
PLUG SEAT
P 13
REGULAR
P13-150
P13-175
P13-200
P13-225
P13-250
P13-275
P13-325
P13-350
P13-375
PLUNGERS
P-1
CATALOG 2012.05
Bolland
IN WELLS WITH SAND, THEY ARE USED CONNECTED TO BOTH ENDS OF A PLAIN
METAL SPRAYED PLUNGER.
THE SOFT RINGS INSTALLED IN THE GROOVES, PREVENT THE ENTERING OF SAND
BETWEEN THE PLUNGER AND THE BARREL, THUS EXTENDING THE SERVICE LIFE
OF THE PUMP.
THE MATERIAL OF THE RINGS MUST BE SELECTED TAKING INTO ACCOUNT THE
TEMPERATURE OF THE WELL AND THE TYPE OF CHEMICAL PRODUCT USED.
RING, PLUNGER
APB
APB125X
APB150X
APB175X
APB200X
APB225X
APB250X
APB275X
APB325X
IN WELLS WITH SAND, THEY ARE USED CONNECTED TO BOTH ENDS OF A PLAIN
METAL SPRAYED PLUNGER.
THE SOFT RINGS INSTALLED IN THE GROOVES, PREVENT THE ENTERING OF SAND
BETWEEN THE PLUNGER AND THE BARREL, THUS EXTENDING THE SERVICE LIFE
OF THE PUMP.
THE MATERIAL OF THE RINGS MUST BE SELECTED TAKING INTO ACCOUNT THE
TEMPERATURE OF THE WELL AND THE TYPE OF CHEMICAL PRODUCT USED.
LUBRI - PLUNGER
P 26
P26-125
P26-150
P26-175
P26-200
P26-225
P26-250
P26-275
P26-325
LUBRI - PLUNGER,
MONEL PIN ENDS
P 26 - MP
P26-125MP
P26-150MP
P26-175MP
P26-200MP
P26-225MP
P26-250MP
P26-275MP
P26-325MP
PULLERS
Q-1
CATALOG 2012.05
Bolland
ASSEMBLY
REGULAR P31-175T P31-225T P31-275T P31-325T P31-375T
HEAVY DUTY P31-175THD P31-225THD P31-275THD P31-325THD P31-375THD
HEAT TREATED P31-175THT P31-225THT P31-275THT P31-325THT P31-375THT
BRASS P31-175TLA P31-225TLA P31-275TLA P31-325TLA P31-375TLA
STAINLESS STEEL P31-175TSS P31-225TSS P31-275TSS P31-325TSS P31-375TSS
PARTS
REGULAR P31-175TC P31-225TC P31-275TC P31-325TC P31-375TC
HEAVY DUTY P31-175TCHD P31-225TCHD P31-275TCHD P31-325TCHD P31-375TCHD
A HEAT TREAT. P31-175TCHT P31-225TCHT P31-275TCHT P31-325TCHT P31-375TCHT
BRASS P31-175TCLA P31-225TCLA P31-275TCLA P31-325TCLA P31-375TCLA
STAINLESS P31-175TCSS P31-225TCSS P31-275TCSS P31-325TCSS P31-375TCSS
REGULAR
HEAVY DUTY P31-175TR
B HEAT TREAT.
BRASS
P31-175TRSS
STAINLESS
REGULAR
HEAVY DUTY P31-175TG
C HEAT TREAT.
BRASS P31-175TGLA
STAINLESS P31-175TGSS
REGULAR
HEAVY DUTY
D HEAT TREAT. P31-175TT
BRASS
STAINLESS
Q-2
CATALOG 2012.05
Bolland
ASSEMBLY
REGULAR P31-175TB P31-225TB P31-275TB P31-325TB P31-375TB
HEAVY DUTY P31-175TBHD P31-225TBHD P31-275TBHD P31-325TBHD P31-375TBHD
HEAT TREATED P31-175TBHT P31-225TBHT P31-275TBHT P31-325TBHT P31-375TBHT
BRASS P31-175TBLA P31-225TBLA P31-275TBLA P31-325TBLA P31-375TBLA
STAINLESS STEEL P31-175TBSS P31-225TBSS P31-275TBSS P31-325TBSS P31-375TBSS
PARTS
REGULAR P31-175TBC P31-225TBC P31-275TBC P31-325TBC P31-375TBC
HEAVY DUTY P31-175TBCHD P31-225TBCHD P31-275TBCHD P31-325TBCHD P31-375TBCHD
A HEAT TREAT. P31-175TBCHT P31-225TBCHT P31-275TBCHT P31-325TBCHT P31-375TBCHT
BRASS P31-175TBCLA P31-225TBCLA P31-275TBCLA P31-325TBCLA P31-375TBCLA
STAINLESS P31-175TBCSS P31-225TBCSS P31-275TBCSS P31-325TBCSS P31-375TBCSS
REGULAR
HEAVY DUTY P31-175TR
B HEAT TREAT.
BRASS
P31-175TRSS
STAINLESS
REGULAR
HEAVY DUTY P31-175TG
C HEAT TREAT.
BRASS P31-175TGLA
STAINLESS P31-175TGSS
REGULAR
HEAVY DUTY
D HEAT TREAT. P31-175TT
BRASS
STAINLESS
Q-3
CATALOG 2012.05
Bolland
RODS
R-1
CATALOG 2012.05
Bolland
POLISHED ROD
PR
DIAMETER POLISHED CHROME PLATED
1- 1/4 PRP114-XX PRC114-XX
1- 1/2 PRP112-XX PRC112-XX
THE USE OF CLAMPS IS NOT RECOMMENDED WHEN THE POLISHED ROD IS COMPLETELY
CHROME PLATED. IN THIS CASES, IT IS RECOMMENDED TO REPLACE THE CLAMP WITH A
POLISHED ROD COUPLING. THE SPACING IS OBTAINED INSTALLING THESE SUPPLEMENTS
BETWEEN THE CARRIER BAR AND THE COUPLING.
R-4
CATALOG 2012.05
Bolland
ROD, VALVE
R 11
STANDARD STAINLESS ST.
R11-20-XXX
R11-25-XXX R11-25-XXXSS
R11-30-XXX
R11-30V-XXX
R11-35-XXX
SEATINGS
S-1
CATALOG 2012.05
Bolland
SEATING CUP,
HOLLOW VALVE ROD PUMP
S 12 - T
TEFLON WITH COKE
S12-25TC
A
SEATING ASSEMBLY,
MECHANICAL TOP LOCK
S 21
ASSEMBLY
B STANDARD S21-20-125 S21-20 S21-25 S21-30
PARTS
A
B SEATING ASSEMBLY,
MECHANICAL TOP LOCK, SEAL RING
S 21 - U
C ASSEMBLY
STANDARD S21-20-125U S21-20U S21-25U S21-30U
PARTS
D A S21-20MU S21-20MU S21-25MU S21-30MU
SEATING ASSEMBLY,
MECHANICAL BOTTOM LOCK
S 22
ASSEMBLY
STANDARD S22-20 S22-25 S22-30 S22-35 S22-40
PARTS
NO-GO SEAT
S 28
REGULAR
S28-25
S28-30
S28-35
PULL TUBES
T-1
CATALOG 2012.05
Bolland
TUBE, PULL
T 11
STANDARD
T11-106-XXX
T11-125-XXX
T11-150-XXX
T11-175-XXX
T11-200-XXX
T11-225-XXX
TUBE, PULL,
HOLLOW VALVE ROD PUMP
T 11 - T
STANDARD
T11-175T-XXX
USED IN THE TOP PLUNGER CAGE C12 , REPLACES THE VALVE SEAT IN CASES
WHEN THE VALVE (SEAT AND BALL ASSEMBLY) IS NOT NEEDED.
U-2
CATALOG 2012.05
Bolland
V 11
(CONTINUE)
V 11
SEAT
VAS
DESCRIPTION SEAT
BALL
VBO
DIAMETER BALL
BALL STAINLESS ST. MAXALLOY TUNGSTEN C. SILICON NITRIDE
5/8 VBO106ST VBO106M VBO106C VBO106N
* 11/16 VBO125STC VBO125MC VBO125CC
3/4" VBO125ST VBO125M VBO125C VBO125N
* 7/8 VBO150STC VBO150MC VBO150CC VBO150NC
15/16 VBO150ST VBO150M VBO150C VBO150N
* 1 VBO175STC VBO175MC VBO175CC VBO175NC
1- 1/8 VBO175ST VBO175M VBO175C VBO175N
1- 1/4" VBO200ST VBO200M VBO200C VBO200N
1- 3/8 VBO225ST VBO225M VBO225C VBO225N
* 1- 1/2" VBO250STC VBO250MC VBO250CC VBO250NC
1- 11/16 VBO250ST VBO250M VBO250C VBO250N
* 2 VBO325STC VBO325CC VBO325NC
2- 1/8 VBO325C VBO325N
2- 1/4
DIAMETER BALL
SEAT
V 12 A
DESCRIPTION SEAT
BALL
V 12 B / VBO
DIAMETER BALL
O-RING, VALVE
V 12 R
VALVE AFLAS 83
1- 1/4 V12R125
1- 1/2" V12R150
1- 3/4" V12R175
2" V12R200
2- 1/4" V12R225
2- 1/2 V12R250
3" V12R300
3- 1/4" V12R325
3- 1/2 V12R350
V
CATALOG 2012.05
Bolland
ACCESSORIES
V-1
CATALOG 2012.05
Bolland
TUBING SIZE ROD SIZE EXT. DIAMETER THREAD 1 THREAD 2 PART NUMBER
20 5/8 1- 13/16 PIN BOX 88B21-20MH58
20 3/4 1- 13/16 PIN BOX 88B21-20MH34
25 3/4 2- 5/16 BOX BOX 88B21-25HH34
25 3/4 2- 5/16 BOX PIN 88B21-25HM34
25 7/8 2- 5/16 BOX PIN 88B21-25HM78
25 7/8 2- 5/16 PIN PIN 88B21-25MM78
25 7/8 2- 5/16 PIN BOX 88B21-25MH78
30 3/4 2- 3/4 BOX BOX 88B21-30HH34
30 3/4 2- 3/4 PIN BOX 88B21-30MH34
30 7/8 2- 3/4 BOX BOX 88B21-30HH78
30 7/8 2- 3/4 BOX PIN 88B21-30HM78
30 1 2- 3/4 PIN PIN 88B21-30MM1
40 1" 3- 5/8" PIN PIN 88B21-40MM1
INSTALLED ABOVE THE PUMP, IT CENTERS THE SUCKER ROD STRING, REDUCING WEAR BETWEEN
THE SUCKER ROD COUPLINGS AND THE TUBING.
IT IS ALSO USED TO ELIMINATE PARAFFIN FROM THE TUBING WALLS.
V-2
CATALOG 2012.05
Bolland
NIPPLE, STRAINER
CF
TUBING SIZE NOM. PIPE SIZE LENGTH ( mm ) HOLE DIAM. ( mm ) STANDARD BRASS
20 1 470 5 CF238-070 CF238-070LA
20 1 470 7 CF238-070-7 CF238-070-7LA
25 1- 1/4 400 5 CF278-070 CF278-070LA
25 1- 1/4 400 9 CF278-070-9 CF278-070-9LA
25 1- 1/4 700 5 CF278-120 CF278-120LA
25 1- 1/4 700 9 CF278-120-9 CF278-120-9LA
30 1- 1/2 400 5 CF312-070 CF312-070LA
30 1- 1/2 400 9 CF312-070-9 CF312-070-9LA
30 1- 1/2 700 5 CF312-120 CF312-120LA
30 1- 1/2 700 9 CF312-120-9 CF312-120-9LA
V-3
CATALOG 2012.05
Bolland
F
ASSEMBLY 1
EXT. DIA. ( mm ) 49,8 58,5 58,5 62,0
B
STANDARD COO278-78 COO300-78 COO300-78-100 COO312-78
C MONEL COO278-78MO COO300-78MO COO300-78-100MO COO312-78MO
ITEM PARTS
G
STANDARD COO278-78-1 COO300-78-1 COO300-100-1 COO312-78-1
A
D MONEL COO278-78-1MO COO300-78-1MO COO300-100-1MO COO312-78-1MO
ALLOWS THE INSTALLATION OF LARGER SIZED TH PUMPS THAN THOSE ALLOWED BY THE
E TUBING. IT IS ALSO USED FOR TH PUMPS WITH PLUNGERS WITH SOFT RINGS.
IN BOTH CASES, THE BARREL IS LOWERED WITH THE PLUNGER INSIDE. THEN THE
SUCKER RODS ARE LOWERED AND CONNECTED OR DISCONNECTED TO THE PLUNGER
BY THIS TOOL.
V-4
CATALOG 2012.05
Bolland
B
ASSEMBLY
EXT. DIAMETER ( mm ) 58,5
STANDARD COT300-78
MONEL COT300-78MO
ITEM PARTS
STANDARD COT300-78-1
A
MONEL COT300-78-1MO
STANDARD COT300-78-2
B
A MONEL COT300-78-2MO
STANDARD COT300-78-3
C
MONEL COT300-78-3MO
E
D STANDARD COT300-78-4
C
E STANDARD COT300-78-5
ALLOWS THE INSTALLATION OF LARGER SIZED TH PUMPS THAN THOSE ALLOWED BY THE
TUBING. IT IS ALSO USED FOR TH PUMPS WITH PLUNGERS WITH SOFT RINGS.
IN BOTH CASES, THE BARREL IS LOWERED WITH THE PLUNGER INSIDE. THEN THE
SUCKER RODS ARE LOWERED AND CONNECTED OR DISCONNECTED TO THE PLUNGER
BY THIS TOOL.
V-5
CATALOG 2012.05
Bolland
ASSEMBLY
REGULAR DRI 34
PARTS
A DRI 34-1
B DRI 34-2
INSTALLED BETWEEN THE SUCKER ROD STRING AND THE BUSHING VALVE
ROD B21 , ALLOWS, WHEN NECESSARY, TO UNSCREW THE WHOLE SUCKER
B ROD STRING FROM THE PUMP.
BEEING THE ONLY PART WITH LEFT-HAND THREAD, IT IS THE ONLY POINT THAT
LOOSENS WHILE ALL THE OTHERS TIGHTEN.
IN CASES OF STUCK PUMPS, IT ALLOWS TO RETRIEVE FROM THE SURFACE ALL
THE SUCKER RODS, SEPARATELY FROM THE TUBING.
V-6
CATALOG 2012.05
Bolland
RECIRCULATORY VALVE
VR 25
ASSEMBLY
B VR 25
C ITEM PARTS
A VR 25-1
B VR 25-2
D C VR 25-3
D VR 25-4
E C13-225A2
F C13-225X1
G C13-225X3HT
E
F
ALLOWS TO SIMULTANEOUSLY OPEN THE STANDING AND THE TRAVELING
G VALVES, TO INJECT CHEMICAL PRODUCTS, STEAM, OR HOT OIL, INVERSELY
THROUGH THE PRODUCTION LINE.
V-7
CATALOG 2012.05
Bolland
ASSEMBLY
INSTALLED AT THE TOP OF THE PUMP AND BELOW THE VALVE ROD GUIDE G11 , ALLOWS TO
REDUCE THE PUMP DISCHARGE PRESSURE AND, CONSEQUENTLY, TO FACILITATE THE OPENING
OF THE TRAVELING VALVE.
V-8
CATALOG 2012.05
Bolland
E
G
ASSEMBLY
ITEM PARTS
A SSA278-1 SSA312-1
C SSA278-3 SSA312-3
D SSA278-4 SSA312-4
E SSA278-5 SSA312-5
G SSA278-7 SSA312-7
ASSEMBLY
A
2- 7/8 3- 1/2
D DT278 DT312
ITEM PARTS
B
C A DT278-1 DT312-1
E B DT278-2 DT312-2
C DT278-3 DT312-3
D DT278-4 DT312-4
E DT278-5 (required 6)
USED TO PURGE THE PRODUCTION LINE (TUBING), IT ALLOWS THE REMOVAL OF THE PUMP
WITHOUT PETROLEUM INSIDE.
ITS 4 HOLES LET A QUICK DRAIN OF THE FLUID COLUMN, EVEN WITH VISCOUS FLUIDS.
REDUCES OPERATION COSTS IN PULLING MANEUVERS, PROVIDING A SAFER JOB AND
ELIMINATING CONTAMINATION DUE TO PETROLEUM SPILLING.
INSTALLED IN THE TUBING AT A REQUIRED DEPTH, IT IS ACTIVATED BY BREAKING THE PINS
WITH HYDRAULIC PRESSURE INSIDE THE TUBING.
V-10
CATALOG 2012.05
Bolland
GAS SEPARATOR
SG 278 AX
ASSEMBLY
CASING 5- 1/2"
TUBING 2- 7/8
ARRIBA
A C34-25
B N21-25-36
C SG278A3-1 SG278A6-1
D N22-25-24
C
IT IS USED TO RELEASE GAS FROM THE FLUID BEFORE IT REACHES THE PUMP. IN THIS WAY,
THE GAS RELEASED WILL FLOW TO THE SURFACE THROUGH THE ANNULAR BETWEEN THE
TUBING AND CASING, TO BE EXTRACTED WITHOUT GENERATING PUMPING PROBLEMS.
1) THE VOLUME OF THE CALM ZONE SHALL BE EQUAL OR SUPERIOR TO THE ACTUAL PUMP
VOLUME.
2) THE MAXIMUM PUMPING SPEED SHALL BE SUCH AS TO ALLOW A FLUID SPEED OF LOWER
THAN 15 cm PER SECOND IN THE SEPARATOR CALM ZONE.
4) THE LOWER END MUST BE CLOSED, EITHER BY PLACING PIPES WITH A BLOCKED END OR
BY THE COMBINATION OF A SEPARATOR WITH A CHECK VALVE (SEE NEXT PAGE).
D
V-11
CATALOG 2012.05
Bolland
BLANK COVER,
GAS SEPARATOR
TCSG 278
REGULAR
TCSG278
PURGE VALVE,
GAS SEPARATOR
VPSG 278
A
ASSEMBLY
VPSG278
ITEM PARTS
B A VPSG278-1
B VPSG278-2
C C V11-225ST
D D VPSG278-4
E VPSG278-3
E F VPSG278-6
F G VPSG278-5
G
SAND PUMP
BPA 25300
I
H
ASSEMBLY
BPA25300
E H 1 BPA25300-8
I 1 BPA25300-9
D
J 1 BPA25300-10
K K 1 VBO175STC
C L 2 BPA25300-12
L
B
J
V-13
CATALOG 2012.05
Bolland
RETAINING VALVE
BPA - 13
ASSEMBLY
2- 7/8
BPA25300-13
A ITEM PARTS
A BPA25300-13A
B P12-250E
C
C V11-250STC
ADVANCE TOOL,
TOOTHED SPOON
BPA - 14
2- 7/8
STANDARD
BPA25300-14
ADVANCE TOOL,
SPOON
BPA - 15
2- 7/8
STANDARD
BPA25300-15
TUBING
2-7/8"
PUMP
BPA25300
TUBING
2-7/8"
** RETAINING
VALVE BPA25300-13
TUBING
2-7/8"
** RETAINING **
VALVE BPA25300-13 VALVES REQUIREMENT
ACCORDING TO WELL
TUBING
2-7/8"
** RETAINING
VALVE BPA25300-13
BPA25300-15
BPA25300-14
ADVANCE
TOOL
V-15
CATALOG 2012.05
Bolland
ALLOWS TO TRANSFORM A BOX END PLUNGER P23 INTO A PIN END PLUNGER P22.
USED TO FIT A DOUBLE SEATING PUMP WITH A SIMPLE CLOSED BARREL CAGE C14
INTO A DOUBLE SEATING NIPPLE TUBING, DESIGNED FOR A PUMP WITH DOUBLE
CLOSED BARREL CAGE C14-D.
IT MUST BE INSTALLED BETWEEN THE C14 CAGE AND THE S22 MECHANICAL
BOTTOM LOCK SEATING ASSEMBLY.
THE SHORT ONE IS USED WITH THE API DIMENSIONS C14 CAGE.
THE LONG ONE IS USED WITH THE SHORT C14 CAGE.
MANDREL CONNECTOR
X 12
STANDARD
X12-150
X12-200
X12-250
B INSTALLED AT THE TOP OF THE PUMP, BETWEEN THE CONNECTOR UPPER BARREL
C23 OR NO-GO SEAT S28 AND THE VALVE ROD GUIDE G11, ALLOWS TO REDUCE
THE PUMP DISCHARGE PRESSURE AND, CONSEQUENTLY, TO FACILITATE THE
OPENING OF THE TRAVELING VALVE.
PUMP CENTRALIZER
CB
STANDARD
CB20-25
CB25-30
CB25-35
CB30-35