Report Title Ultrasonic Thickness Testing


Report Number 046132-1-1
Report Date 12 June 2017
Customer FQM AUSTRALIA NICKEL PTY LTD
Customer Contact Benjamin Price
Customer Address Locked Bag 100, RAVENSTHORPE, WA 6346 Australia
Order Number
Test Description Ultrasonic Wall Thickness Evaluation of Tank 7's Lower Strake
Place of Test FQM Ravensthorpe
Test Date Between 05 June 2017 and 06 June 2017
Technician(s) Vijayananthan ARUMUGAM
Qualifications /
ISO 9712 Level I
Certifications

Product Standard NA
Test Procedure NDT.UT.003 Thickness Determination
Test Standard AS 2452.3 - 2005
Material Specification Carbon Steel
Acceptance Standard Report All Findings

Attachments 01 Attached

Accredited for compliance with ISO/IEC 17025 - Testing.


Accreditation # 218. This document shall not be reproduced
except in full.

046132-1-1 Page 1 of 2

Right Solutions Right Partner www.alsglobal.com


TEST CONDITIONS

Surface Preparation Painted

Surface Condition In Service


Area Tested Ultrasonic Thickness Testing was performed on nominated locations of Tank 7
bottom strake first shell plates.
Test Restrictions NIL

RESULTS OF EXAMINATION

Identification Location Thickness (mm)

Tank 7 Please refer to attachment 7.7-13.5

Abbreviations
C = Complies with Acceptance Standard/Code DNC = Does Not Comply with Acceptance Standard/Code Acc = Acceptable UAcc = Unacceptable NA = Not Applicable

TECHNICAL DATA

UT Set Type USM 35S UT Set Serial A2274


Calibration Block AS 2083 No 7 Calibration Block Serial B0027
Couplant Cellulose paste Reading Accuracy +(mm) 0.20

Test Method SR

Probe Type Serial No Frequency (MHz) Size (mm) Angle (degrees)

Twin Compression 26419 5 MHz 10 0 degrees

Terms and Conditions


Refer to www.alsglobal.com/~/media/Files/Divisions/Industrial/Asset Care/Asset Care Resources/Terms and Conditions/ALS-Terms-and-Conditions-Industrial-Australia-2015.pdf

ALS Report Disclaimer


a) Any report, findings, results, statement, certification issued by ALS (ALS Report) is issued on the basis of testing of samples or materials, information, or documents provided by,
or on behalf of, the Client. The Client will indemnify and hold harmless ALS, its officers, employees, agents and subcontractors for any claim whatsoever in relation to any ALS Report
arising from unclear, erroneous, incomplete, misleading or false information provided to ALS; or arising from any incorrect or defective materials or samples provided to ALS.
b) Each ALS Report is:
i) issued using detection limits and confidence intervals inherent in ALSs testing methodology;
ii) contains ALSs results and opinions (if provided) on those samples or specific materials only;
iii) solely for the benefit of the Client, its officers and employees; and
iv) prepared at the request of the Client for the purpose agreed between the Client and ALS, and the Client may disclose the report to a third party for that purpose only, but
ALS does not accept any responsibility or liability (including, without limitation, liability for negligence) to that third party.
c) The Client indemnifies ALS, its directors, employees, agents, consultants, contractors, successors in title and assigns against any claim made against any or all of them by third parties
arising out of either the disclosure of any ALS Report, whether directly or indirectly by the Client, to a third party; or any reproduction or publication of an extract of any ALS Report.
d) The Client acknowledges and agrees that any action, inaction, or decision of the Client in response to the ALS Report will be determined by the Client. Neither ALS nor any of its
officers, employees, agents, or subcontractors will be liable to the Client or any third party for any action or inaction of the Client in response to any ALS Report.

046132-1-1 Page 2 of 2

Right Solutions Right Partner www.alsglobal.com


ATTACHMENT A

Ultrasonic thickness testing was performed on nominated locations of Tank 07 Bottom strake
(first shell plates). Scanning was carried out of 1 metre interval and 100 mm band width from
top of the plate to the bottom of the plate.

Note: All dimensions are in mm

Report No. <046132-1-1> ATTACHMENT A P1 of 4

Right Solutions Right Partner www.alsglobal.com


Locations tested:

1000
2800

1000

100

1000

Report No. <046132-1-1> ATTACHMENT A P2 of 4

Right Solutions Right Partner www.alsglobal.com


Plate 1

Location 1 2 3 4 5 6 7 8 9 10
Min 13.2 13.3 13.5 13.5 13.5 13.4 13.3 11.5 7.7 12.2

Location 11 12 13
Min 13.3 13.5 13.2

Plate 2

Location 14
Min 13.0

Plate 3

Location 15 16 17 18 19 20 21 22 23 24
Min 13.3 13.4 13.4 13.5 13.5 12.2 13.2 13.5 11.0 13.4

Plate 4

Location 25 26 27 28 29 30 31 32 33 34
Min 13.3 13.3 13.4 13.3 13.3 13.4 13.4 13.4 13.4 13.5

Location 35
Min 13.3

Plate 5

Location 36 37 38
Min 13.2 13.0 13.1

Plate 6

Location 39 40 41 42 43 44 45 46
Min 12.9 13.4 13.3 12.8 13.0 13.3 13.2 13.3

Report No. <046132-1-1> ATTACHMENT A P3 of 4

Right Solutions Right Partner www.alsglobal.com


Low thickness readings near South manway Plate 1

2200

7.7 to 11 mm

South Manway

1800

Report No. <046132-1-1> ATTACHMENT A P4 of 4