You are on page 1of 6

ComFlor 46/0.

9/S280 BS 5950 Parts 4, 6 and 8 Page 1 of 6

SCI Tata Steel v9.0.30.0


JOB REFERENCE: Date: 10/12/2017
DECK REFERENCE: CF46/0.9_280 Time: 14:24:31
COMPANY NAME: Job No.:
CLIENT NAME:
FILENAME: Calcs by: Checked by:

FULL OUTPUT

NOTE: SECTION DESIGNED TO BRITISH STANDARDS


Construction Stage: PASS Max Unity Factor = 0.63
Normal Stage: PASS Max Unity Factor = 0.29
Fire Condition: PASS Max Unity Factor = 0.43
Serviceability: SATISFACTORY Max Unity Factor = 0.35

*** SECTION ADEQUATE ***


FLOOR PLAN DATA : (unpropped composite construction with ComFlor 46/0.9/S280 decking)
Beam centres - equal 2.10 m Span type MULTIPLE
Beam or wall width 200 mm Propping NONE

PROFILE DATA : (ComFlor 46/0.9/S280 decking)


Depth 46 mm Pitch of deck ribs 225 mm
Trough width 105 mm Crest width 67.0 mm
Nominal sheet thickness 0.90 mm Design sheet thickness 0.86 mm
Deck weight 0.09 kN/m Yield strength 280 N/mm

CONCRETE SLAB : [Normal Weight Concrete ; Mesh : A252]


Overall slab depth 150 mm
Concrete characteristic strength 40 N/mm Concrete wet density 2400 kg/m
Modular ratio 10 Concrete dry density 2350 kg/m
Bar reinforcement :
Diameter 10 mm Yield strength 460 N/mm
Distance from slab soffit 30 mm
Mesh reinforcement :
Mesh A252 Yield strength 460 N/mm
Cover to Mesh 25 mm Mesh Layers Single
Account for End Anchorage NO Shear connectors per rib N/A
Diameter of Shear Connectors N/A
Screeds N/A

SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations

DECK PROFILE:
Sagging Inertia, Ixx 41.500 cm4/m Area of profile (Net), Ap 1137 mm/m
Hogging Inertia, Iyy 0.000 cm4/m

File Name: v9.0.30.0


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 2 of 6

COMPOSITE:
Inertia, Ixx - Uncracked 2666 cm4/m Cracked 1348 cm4/m
Average inertia 2007 cm4/m Cracked inertia (dynamic) 1534 cm4/m
Shear bond coefficients - Mr 86.80 Kr 0.039600
Concrete volume 0.131 m/m/m

LOADS ACTING ON SLAB :


*** NOTE: Slab subjected to uniformly distributed loads (UDL) ONLY
Imposed (occupancy) 5.00 kN/m Partitions 0.00 kN/m
Ceilings and services 3.00 kN/m Finishes 4.50 kN/m
Self weight of concrete slab (wet) 3.08 kN/m Self weight of decking 0.09 kN/m
Self weight of concrete slab (dry) 3.02 kN/m Screeds NONE
Construction load 2.1 kN/m

LINE LOADS PERPENDICULAR TO DECK SPAN :


None

LINE LOADS PARALLEL TO DECK SPAN :


None

FIRE DATA :
Design method FIRE ENGINEERING Fire resistance period 60 mins
Non-permanent imposed loads 0.0 kN/m

PARTIAL SAFETY FACTORS :


Dead (self weight) 1.40 Imposed 1.60
Super imposed dead 1.40 Fire (occupancy loads) 0.80

File Name: v9.0.30.0


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 3 of 6

CONSTRUCTION STAGE

LOADINGS Unfactored(kN/m) Factored(kN/m)


Self weight of decking 0.09 0.13
Self weight of concrete slab (wet) 3.08 4.31
Construction load (one span) 2.14 3.43
Construction load (adjacent span(s)) 0.71 1.14
Total factored load (maximum) = 0.13 + 4.31 + 0.00 + 3.43
= 7.87 kN/m

EFFECTIVE SPAN OF DECK :


Effective span Le, is the smaller of
1) c/c of supports = 2.10 m
2) clear span + deck depth = 1.90 + 46.0 / 1000
= 1.95 m
Therefore Le = 1.95 m

SHEAR RESISTANCE CHECK :


*** Check at first interior support position
Applied shear = [1.100 * 0.13 + 1.200 * 4.31 + 1.200 * 0.11 + 2.500 * 3.43/3] * 1.95 / 2
= 8.08 kN/m
Shear strength of decking, pv = 168.0 N/mm
Shear resistance, Pv = 59.1 kN/m
UNITY FACTOR = 0.14 PASS

WEB CRUSHING RESISTANCE CHECK :


*** Check at first interior support position
Applied reaction 16.15 kN/m
Web crushing resistance, Pw 47.54 kN/m
UNITY FACTOR = 0.34 PASS

BENDING RESISTANCE CHECK :


NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance

SAGGING:
Max applied moment = [0.080 * 0.13 + 0.094 * 4.31 + 0.094 * 0.11 + 0.094 * 3.43] * 1.95^2
= 2.83 kNm/m
Moment resistance, Mc = 4.63 kNm/m
UNITY FACTOR = 0.61 PASS

HOGGING:
Max. applied moment = 2.16 kNm/m
Moment resistance, Mc = 4.67 kNm/m
UNITY FACTOR = 0.46 PASS

INTERACTION OF BENDING MOMENT AND SHEAR :


NOTE 1: *** Check at first interior support position
NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied shear = 8.08 kN/m
Shear resistance, Pv = 59.08 kN/m
Applied moment = 2.16 kNm/m
Moment resistance, Mc = 4.67 kNm/m
UNITY FACTOR = [8.08/59.08]^2 + [3.09/4.67]^2
= 0.23 PASS

File Name: v9.0.30.0


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 4 of 6

INTERACTION OF BENDING MOMENT AND WEB CRUSHING :


NOTE 1: *** Check at first interior support position
NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied reaction = 15.20 kN/m
Web crushing resistance, Pw = 47.54 kN/m
Applied moment = 2.16 kNm/m
Moment resistance, Mc = 4.67 kNm/m
UNITY FACTOR = [15.20/47.54 + 2.16/4.67]
= 0.78 < 1.25 PASS

DEFLECTION CHECK :
Allowable deflection max, is the lesser of
1) Effective span/180 (= 10.8 mm ), and
2) 20 mm ( absolute maximum value ), and
3) Slab depth/10 = ( 15.0 mm )
Max. self weight deflection = 3.78 mm
( < 10.81 mm ) SATISFACTORY
***NOTE: Deflection within code limits; ponding is not considered

File Name: v9.0.30.0


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 5 of 6

NORMAL STAGE

LOADINGS : (see construction load calculations for details):


Unfactored (kN/m) Factored (kN/m)
Dead 0.09 + 3.02
= 3.11 4.35
Imposed 5.00 + 0.00
= 5.00 8.00
Superimposed dead 3.00 + 4.50 + 0.00
= 7.50 10.50
Total = 15.61 kN/m 22.85 kN/m

EFFECTIVE SPAN :
Effective span Le, is the smaller of
1) c/c of supports
2) clear span + slab overall depth - depth to centroid = 1.9 + 150 / 1000 - 20.38 / 1000
= 2.03 m
Therefore Le = 2.03 m

SHEAR RESISTANCE CHECK :


Maximum applied shear = 0.5 * 22.85 * 2.03
= 23.19 kN/m
Shear stress in concrete, v = 0.32 N/mm
Shear strength of concrete, vc = 1.10 N/mm
Shear resistance = 131.50 * 126.34 * 1.10 / 225.00
= 80.96 kN/m
UNITY FACTOR = 0.29 PASS

PUNCHING SHEAR CHECK :


Not Applicable

SHEAR BOND RESISTANCE CHECK :


Shear span = 2.03 / 4
= 0.51 m
Applied shear = 18.77 kN/m
Shear bond resistance = 72.72 kN/m
Anchorage resistance = 0 kN/m
Total shear resistance = (72722.19/1000) + [(0/1000)]/2 = 72.72 kN/m
UNITY FACTOR = 0.26 PASS

BENDING RESISTANCE CHECK :


Applied bending moment = 0.125 * 22.85 * 2.03^2
= 11.82 kNm/m
Depth of concrete stress block = 24.94 mm
NOTE: depth of concrete in compression may be limited to 0.45 ds
Tension in decking = 296.07 kN/m
Tension in bar reinforcement = 152.92 kN/m
Depth to position of resultant tension = (152.9 * 120.0 + 296.1 * 129.6) / (152.9 + 296.1)
= 126.34 mm
Lever arm = 113.87 mm
NOTE: lever arm may be limited to 0.95 ds
Compression in concrete
= 449.00 kN/m
Moment resistance = 449.00 * 113.87/1000
= 51.13 kNm/m
UNITY FACTOR = 0.23 PASS

File Name: v9.0.30.0


ComFlor 46/0.9/S280 BS 5950 Parts 4, 6 and 8 Page 6 of 6

FIRE RESISTANCE CHECK :


Effective span in fire, is the greater of
1) c/c suppports - support width = 2.10 - 200 / 1000
= 1.90 m
2) c/c supports - 150 = 2.10 - 150 / 1000
= 1.95 m
i.e effective span in fire = 1.95 m
Fire dead load = 0.09 + 3.02 + 3.00 + 4.50 + 0.00
= 10.76 kN/m
Non-permanent fire imposed load = 0.80 * 0.0 *5.00
= 0.0 kN/m
Permanent fire imposed load = (1 - 0.0) *5.00 + 0.00
= 5.00 kN/m
Fire imposed load = 0.00 + 5.00
= 5.00 kN/m
Fire free moment = 7.49 kNm/m
Moment resistance, sagging = 17.52 kNm/m
Moment resistance, Mr = 17.52 kNm/m
UNITY FACTOR = 0.43 PASS

DEFLECTION CHECK :
Allowable deflection max-i under imposed loads, is the lesser of
1) Effective span/350 (= 5.8 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection = 0.013 * 9.50 * (2.03* 1000 )^4 / (205*20069910 )/1000
= 0.3 mm ( < 5.8 mm ) SATISFACTORY
Allowable total deflection max-t, is the lesser of
1) Effective span/250 or 8.1 mm, and
2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads = 0.3 mm (based on average inertia)
Additional deflection due to superimposed dead loads = 0.4 mm (based on average inertia)
Total deflection = 0.3 + 0.4
= 0.7 mm ( < 8.1 mm ) SATISFACTORY

DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed
Dynamic inertia (cracked section) = 1534 cm4
Maximum deflection = 0.013 * 11.11 * (2.03* 1000 )^4 / (205*15335150 )/1000
= 0.79 mm
Frequency = 18 / 0.79 )
= 20.30 Hz ( > 5.00 Hz) SATISFACTORY

File Name: v9.0.30.0