You are on page 1of 7

VISHWAS CONCRETE PRIVATE LIMITED

SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,

YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE

RMC UNIT - 1

SIEVE ANALYSIS OF COARSE AGGREGATE


SOURCE :HOSURE PLANT
DATE :
LOCATION :PLANT BIN

TYPE OF AGGREGATE 20.0mm

IS % Cum. % Cum. %
Weight retained, gms
Sieve, mm retained retained passing

40 0.0 0.00 0.00 100.00

25.00 0.0 0.00 0.00 100.00

20 145.0 2.90 2.90 97.10

12.5 3490.0 69.80 72.70 27.30

10 985.0 19.70 92.40 7.60

4.75 370.0 7.40 99.80 0.20

Pan 10.0 0.20 100.00 0.00

5000

LAB TECHNICAN QC-IN CHARGE


QC 5

GATE

9/8/2017

IS Limits as per IS
383-2016

100

100

85-100

-
0-20

0-5
VISHWAS CONCRETE PRIVATE LIMITED

SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,


QC 5
YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE

RMC UNIT - 1

SIEVE ANALYSIS OF COARSE AGGREGATE


SOURCE :HOSURE PLANT
DATE : 7/19/2017
LOCATION :PLANT BIN

TYPE OF AGGREGATE 20.0mm

IS % Cum. % Cum. % IS Limits as per IS


Weight retained, gms
383-2016
Sieve, mm retained retained passing

40 0.0 0.00 0.00 100.00 100

25.00 0.0 0.00 0.00 100.00 100

20 230.0 4.60 4.60 95.40 85-100

12.5 2210.0 44.20 48.80 51.20 -


32.20 81.00 19.00 0-20
10 1610.0

4.75 870.0 17.40 98.40 1.60 0-5

Pan 80.0 1.60 100.00 0.00

5000

LAB TECHNICAN QC-IN CHARGE


QC 5

SIEVE ANALYSIS OF COARSE AGGREGATE


SOURCE :HOSURE PLANT
DATE : 11/8/2017
LOCATION :PLANT BIN

TYPE OF AGGREGATE 20.0mm

IS Weight retained, % Cum. % Cum. % IS Limits as per IS


gms 383-2016
Sieve, mm retained retained passing

40 0.0 0.00 0.00 100.00 100

25.00 0.0 0.00 0.00 100.00 100

20 657.0 13.14 13.14 86.86 85-100

12.5 2851.0 57.02 70.16 29.84 -


19.22 89.38 10.62 0-20
10 961.0

4.75 531.0 10.62 100.00 0.00 0-5

Pan 0.0 0.00 100.00 0.00

5000

LAB TECHNICAN QC-IN CHARGE


VISHWAS CONCRETE PRIVATE LIMITED

SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,

YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE

RMC UNIT - 1

SIEVE ANALYSIS OF COARSE AGGREGATE


SOURCE :HOSURE PLANT
DATE :
LOCATION :PLANT BIN

TYPE OF AGGREGATE 20.0mm

IS Weight retained, % Cum. % Cum. %


gms
Sieve, mm retained retained passing

40 0.0 0.00 0.00 100.00

25.00 0.0 0.00 0.00 100.00

20 235.0 4.70 4.70 95.30

12.5 2463.0 49.26 53.96 46.04

10 1500.0 30.00 83.96 16.04

4.75 787.0 15.74 99.70 0.30

Pan 15.0 0.30 100.00 0.00

5000

LAB TECHNICAN QC-IN CHARGE


QC 5

ATE

9/19/2017

IS Limits as per IS
383-2016

100

100

85-100

-
0-20

0-5
VISHWAS CONCRETE PRIVATE LIMITED

SY NO:31,THIRUMENAHALLI VILLAGE,R.K.HEGDE NAGAR,


QC 5
YELAHANKA HOBLI,BANGALORE NORTH TALUK,BANGALORE

RMC UNIT - 1

SIEVE ANALYSIS OF COARSE AGGREGATE


SOURCE :HOSURE PLANT
DATE : 9/13/2017
LOCATION :PLANT BIN

TYPE OF AGGREGATE 20.0mm

IS % Cum. % Cum. % IS Limits as per IS


Weight retained, gms
383-2016
Sieve, mm retained retained passing

40 0.0 0.00 0.00 100.00 100

25.00 0.0 0.00 0.00 100.00 100

20 531.0 10.62 10.62 89.38 85-100

12.5 2563.0 51.26 61.88 38.12 -


36.58 98.46 1.54 0-20
10 1829.0

4.75 68.0 1.36 99.82 0.18 0-5

Pan 9.0 0.18 100.00 0.00

5000

LAB TECHNICAN QC-IN CHARGE