STRUCTURAL CALCULATIONS
Using
MASTERSERIES POWERPAD
Project Name1
Address 1
Address 2
Address 3
ARCHITECT
ARCHITECT NAME
Location
Location
Location
STRUCTURAL ENGINEERS
MASTERSERIES SAMPLE OUTPUT
to place your title block here ensure you have copied your personal
TABLESWD.OVR file to the MasterSeries application directory.
In Word 2007 specify the MasterSeries app dir in Trusted Loactions
December 1997
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 2 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
C:\USERS\ERNEST MWANGI\DESKTOP\FRRAAMM.$5
MEMBER 1
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 3 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
Bending Moments
In-Span Steel @ 3000 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
MEMBER 10 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Deep 1.20
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+750)/2 2250
Loy=3000-(0+0)/2 3000
Lex=2700.0 mm, Lex/h=13.5, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 4 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 11 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Shallow, Bottom: Deep 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(0+750)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 5 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Link check
100 As/bd, vc, vc' 1.45%, 0.96 N/mm², 0.96 N/mm²
As/Svreq, Sv, Links 0 mm, 100 mm, 2 no 8 mm legs
Asvreq, Asvpvd 0 mm², 101 mm² 0 Nominal OK
MEMBER 12 : (LEVEL 1)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Shallow 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+0)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 6 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 13 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Deep 1.20
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+750)/2 2250
Loy=3000-(0+0)/2 3000
Lex=2700.0 mm, Lex/h=13.5, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 7 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
No Tie Force case found (1.05D+0.35/1.05L). Using ULS reduced by 1.33=1.40/1.05 conservative
Capacity = 0.95 • fy• Asc 0.95 • 460 • 452 197.7 kN OK
MEMBER 14 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Shallow, Bottom: Deep 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(0+750)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 8 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 15 : (LEVEL 1)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Shallow 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+0)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 9 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 16 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Deep 1.20
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+750)/2 2250
Loy=3000-(0+0)/2 3000
Lex=2700.0 mm, Lex/h=13.5, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 10 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 17 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Shallow, Bottom: Deep 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(0+750)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 11 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 18 : (LEVEL 1)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Shallow 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+0)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 12 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 19 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Deep 1.20
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+750)/2 2250
Loy=3000-(0+0)/2 3000
Lex=2700.0 mm, Lex/h=13.5, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 13 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 2
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 14 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Bending Moments
In-Span Steel @ 3000 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
MEMBER 20 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Shallow, Bottom: Deep 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(0+750)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 15 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 21 : (LEVEL 1)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Shallow 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+0)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 16 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Bar group1:M1 fn(bars,d,ε%,,la,F) 2 x 12, 44.0, 0.035, 69, 56.0, 15.6 0.9 kNm
Bar group2:M2 fn(bars,d,ε%,,la,F) 2 x 12, 156.0, -0.768, -437, -56.0, -98.8 5.5 kNm
Concrete Fc=(Ac•.45•fcu) 8787 x 0.45 x 30 118.6 kN
F Equlibrum (Ft) + FC - Fapp= 0 16 - 99 + 119 - 35.4 0.0 kN OK
Concrete Mc=Fc•(H/2-Ybar) 118.6 x (200 / 2 - 22.0) 9.3 kNm
Mu =Mc + (M1+...+M2) 9.3 + (0.9+5.5) 15.7kNm
Max Moment/Mu 1.0 / 15.7 0.066 OK
X-X Shear Checks
App. Shear Vx, v, v max 0 kN, 0 N/mm², 4.38 N/mm² 0 OK
M/N, 0.6h 29.1 mm, 120 mm Nominal links
MEMBER 22 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Deep 1.20
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+750)/2 2250
Loy=3000-(0+0)/2 3000
Lex=2700.0 mm, Lex/h=13.5, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 17 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 23 : (LEVEL 2)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Shallow, Bottom: Deep 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(0+750)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 18 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 3
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 19 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Bending Moments
In-Span Steel @ 2999 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
MEMBER 4
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 20 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
Bending Moments
In-Span Steel @ 3000 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 21 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 5
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 22 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Bending Moments
In-Span Steel @ 3000 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
MEMBER 6
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 23 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
Bending Moments
In-Span Steel @ 3000 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 24 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 7
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 25 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Bending Moments
In-Span Steel @ 2999 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
MEMBER 8
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 26 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Basic Data
Design to BS 8110: 1997
fcu, fy, fyv, v crit, K1, K2 25, 460, 460, 4.0, 0.41, 0.45
Bending Moments
In-Span Steel @ 3000 mm. Sagging
X/d=Fn(As, fy, K1, Beff, d, fcu, γm) 226, 460, 0.41, 400, 706.0, 25, 0.95 0.03
Mu =(K1•fcu•B•X)•min(d-k2•X,0.95•d) (0.4•25•400•24.3)•(0.95•706.0) 66 kN.m
Mapp/Mu 53.1 / 66.3 0.801 OK
AsRequired to BS8110 Cl 3.4.4.4 Assuming d = 700, d' = 50 bottom 183 mm²
Shear
Max Shear
vcrit= min(5, 0.8•sqr(fcu) min(5, 0.8 • sqr(25) ) 4.000 N/mm²
v = Vmax/ (d • b) 35 • 1000 / (706 • 400) 0.125 N/mm² OK
Nominal Shear Zone at 1 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
Nominal Shear Zone at 5999 mm
vc=Fn(As, bv, d, fcu) 452, 400, 706, 25 0.34 N/mm² Table 3.8
Vcap=Fn(Asv, Sv, bv, d, fyv, vc) 101, 250, 400, 706, 460, 0.34 221.6 kN Table 3.7
V/Vcap 35.4/ 221.6 0.160 OK
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 27 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
MEMBER 9 : (LEVEL 1)
Basic Data
Design to BS 8110: 1997
Grades Fy, Fyv, Fcu 460 N/mm², 460 N/mm², 30 N/mm²
Restraint Conditions and Effective Lengths
βx : for 200 mm deep column Top: Deep, Bottom: Shallow 1.30
βy : for 200 mm wide column Top: Shallow, Bottom: Shallow 1.50
Lc=3000 Lox=3000-(750+0)/2 2625
Loy=3000-(0+0)/2 3000
Lex=3412.5 mm, Lex/h=17.1, exx=10.0 mm
Ley=4500.0 mm, Ley/b=22.5, eyy=10.0 mm
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 28 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
PAD 1 @ NODE 1
Basic Properties
Design to BS 8110: 1997
Fy, Fcu, Covers T, B, S 460 N/mm², 30 N/mm², 50 mm, 50 mm, 50 mm
Gross: Area, Area1, Z zz, Z xx 0.723, 0.04, 0.102, 0.102
Conc Den, Surcharge, LFsrv , LFult, SWP23.4, 0.0, 1.0, 1.0, 100
Z-Z Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 372, 850, 34, 0.4, 30 131 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 392, 30 0.42 N/mm²
X-X Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 357, 850, 34, 0.4, 30 126 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 376, 30 0.43 N/mm²
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 29 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
PAD 3 @ NODE 5
Basic Properties
Design to BS 8110: 1997
Fy, Fcu, Covers T, B, S 460 N/mm², 30 N/mm², 50 mm, 50 mm, 50 mm
Gross: Area, Area1, Z zz, Z xx 0.723, 0.04, 0.102, 0.102
Conc Den, Surcharge, LFsrv , LFult, SWP23.4, 0.0, 1.0, 1.0, 100
Z-Z Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 372, 850, 34, 0.4, 30 131 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 392, 30 0.42 N/mm²
X-X Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 357, 850, 34, 0.4, 30 126 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 376, 30 0.43 N/mm²
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 30 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
Pressure
Pmax = F res / Area 55.6 / 0.723 77.0 kN/m² OK
PAD 5 @ NODE 9
Basic Properties
Design to BS 8110: 1997
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 31 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 32 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
PAD 7 @ NODE 13
Basic Properties
Design to BS 8110: 1997
Fy, Fcu, Covers T, B, S 460 N/mm², 30 N/mm², 50 mm, 50 mm, 50 mm
Gross: Area, Area1, Z zz, Z xx 0.723, 0.04, 0.102, 0.102
Conc Den, Surcharge, LFsrv , LFult, SWP23.4, 0.0, 1.0, 1.0, 100
Z-Z Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 372, 850, 34, 0.4, 30 131 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 392, 30 0.42 N/mm²
X-X Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 357, 850, 34, 0.4, 30 126 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 376, 30 0.43 N/mm²
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 33 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
X-X upper Vd, V2d, lad, la2d, d, b, w 0, 0, -51, -427, 376, 850, 10.5 0.00, 0.01 N/mm² OK
Z-Z left Vd, V2d, lad, la2d, d, b, w 0, 0, -67, -459, 392, 850, 10.5 0.00, 0.01 N/mm² OK
Z-Z right Vd, V2d, lad, la2d, d, b, w 0, 0, -67, -459, 392, 850, 10.5 0.00, 0.01 N/mm² OK
Punching Shear
Sub Zone Loads F0=78.4 + F1=0 + F2=0 + F3=0 + F4=0
+ F12=0 + F23=0 + F34=0 + F41=0 78.4 kN
Sub Zone Error = Fres/(F0-F41) (1 - 78.408 / 78.408)•100 0.000% OK
Zone Locations P4------------------- P
| F4 | F41 | F1
|------------------
| F34| F0 | F12 | F0 is bound by Punching Perimite
|------------------| @ 1.5 d from column face
| F3 | F23 | F2
P3------------------- P2
Projections from Column face 2 opposite Projections are less than 1.5 d => Not Applicable
PAD 9 @ NODE 17
Basic Properties
Design to BS 8110: 1997
Fy, Fcu, Covers T, B, S 460 N/mm², 30 N/mm², 50 mm, 50 mm, 50 mm
Gross: Area, Area1, Z zz, Z xx 0.723, 0.04, 0.102, 0.102
Conc Den, Surcharge, LFsrv , LFult, SWP23.4, 0.0, 1.0, 1.0, 100
Z-Z Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 372, 850, 34, 0.4, 30 131 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 392, 30 0.42 N/mm²
X-X Axis Section Capacities
As Bottom bars 4-T16@300 804 mm²
X/d = Fn(AS, Fy, K1, Beff, Fcu, γm) 804, 460, 0.4, 850, 30, 0.95 0.09
Mu conc = Fn(Z, Beff, X, K1, Fcu) 357, 850, 34, 0.4, 30 126 kN.m
vc = Fn(AS, bv, d, Fcu) 804, 850, 376, 30 0.43 N/mm²
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 34 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102
© MasterSeries PowerPad - Project Title Document1
Job ref : Job Ref
MasterSeries Sample Output Sheet : Sheet Ref / 35 -
to place your title block here ensure you have copied your personal Made By :
TABLESWD.OVR file to the MasterSeries application directory. Date : 08 Aug 2017/ Version 2010.05
Checked :
Approved :
© Civil and Structural Computer Services Limited, 1 Circular Road, Newtownabbey, Co. Antrim BT37 0RA, Tel : 028 9036 5950 Fax : 028 9036 5102