Professional Documents
Culture Documents
Purchaser PEMEX Refinería "Fco. I. Madero", Cd. Madero, TM, MEXICO Quote No. 111517-1 Rev. 1 Date 30-July 2013 Serial No.
Owner/User PEMEX Refinería "Fco. I. Madero" Job No. By. Jorge Nava No. Required 4
Service Condensate Pumps Item No. CK-BA-103 A/B & MJE- Req/Spec No. Model Number LMV-801
P-20/20A
Location Cd. Madero, TM, MEXICO Unit PEMEX "Madero" Purchase Order No. Inquiry No.
refinery
Liquid Water Condensate Capacity (GPM) Norm 250.0 Rated 250.0 NPSHR, Water @ rated capacity (ft) 8.1 Stages 1 RPM 3564
Suct Temp (F) Norm 250.0 Max 250.0 Disch.Press (PSI) 125.50 Rated Power (hp) 35.6 Rated Pump Efficiency (%) 53.8
Spec.Grav@Suct.Temp 0.94 Suct.Press (PSI) Max 0.0 Rated 0.0 Max Power Rated Imp. (hp) 46.4 Max Head Rated Imp. (ft) 371.5
Vap.Press@Suct.Temp (PSI-a) 30.0 Diff.Press (PSI) 125.5 Diff.Head (ft) 308.0 Minimum Continuous Stable Flow (GPM) 66.91
Visc@Suct.Temp (cP) Norm 0.23 Max 0.23 NPSHA (ft) 10.0 with control valve within 5.0 (ft) of pump discharge.
Spec.Heat (btu/lbm F) 0.9 Corr./Eros. caused by Motor Rotation (viewed from top of motor) CCW
Specific Speed 740 rpm.gpm.feet Suction Specific Speed 7400
CONSTRUCTION
Seal Cavity Press (PSI) Rated 9.1 Max 18.8
Casing Mounting Vertical-Inline Casing Split Radial Inducer Type Cylindrical - 01
Typical noise level (db) @ (ft) (Pump only)
Diffuser Single Throat Diff.Dia (in) 1 Style Conc. Bowl Impeller Type Open
Mechanical Seal Type Single AUXILIARY PIPING REQUIREMENTS
Seal Part No. Upper none Lower Imp.Dia (in) Rated 8.24 Gearbox Cooling Water Piping N/A
API Seal Code Upper none Lower Max 9.00 Seal Flush Cooling Water Piping Supplied by Customer
API Flush Plans API Plan 21 Min 8.00 Seal Buffer/Barrier Cooling Water Piping N/A
Buffer/Barrier Interconnecting Piping N/A
Nozzle Size Rating Facing Finish Position
CONNECTIONS ANSI ANSI ANSI Microinch AARH
Cooling Water Requirements (GPM) @ 68.0 (F)
Suction 3 in 600 lbs RF 125-250 Side
Gearbox heat exchanger none
Discharge 2 in 600 lbs RF 125-250 Side
Seal Flush 0.0
Rating 50.0 HP RPM 3564 Volts/Phase/Hertz 460/3/60 Qty 4 Steam Temp (F) Inlet Outlet
Page 3 of 9
14845 West 64th Avenue | Arvada, Colorado 80007 USA | Phone: 1.303.425.0800 | Fax: 1.303.425.0896
SUNDYNE PUMP SPECIFICATION SHEET
Applicable to Proposal US Customary
Single-Stage Overhung OH5
Purchaser PEMEX Refinería "Fco. I. Madero", Cd. Madero, TM, MEXICO Quote No. 111517-1 Rev. 1 Date 30-July 2013 Serial No.
Owner/User PEMEX Refinería "Fco. I. Madero" Job No. By. Jorge Nava No. Required 4
Service Condensate Pumps Item No. CK-BA-103 A/B & MJE- Req/Spec No. Model Number LMV-801
P-20/20A
Location Cd. Madero, TM, MEXICO Unit PEMEX "Madero" Purchase Order No. Inquiry No.
refinery
REMARKS
ISO 13709 1st EDITION / API 610 10TH EDITION GOVERNS, EXCEPT AS NOTED ON ATTACHED LIST OF EXCEPTIONS.
Certificate of material conformance.
The rated pump efficiency shown above excludes the effect of the discharge orifice.
Inclusion of the orifice reduces the effective efficiency to 51.3 %.
Discharge orifice plate, Plate 316 SS w/handle (RF).
Carbon steel 1/4 covers with gaskets for pump flanges.
API Plan 21 seal flush and cooling kit 316SS, Exchanger JohnCrane (Temp 400-800F, Pressure 1350-1850 PSI). Recirculation flow is 2 gpm.
Vibration readings non-witnessed, during performance test.
Note: The above stated Nss value is for the Impeller. The proposed pump is fitted with an Inducer with an Nss of 11755 rpm.gpm.feet.
Inlet case max allowable working pressure is 900.0 psi gauge at 250.0degf. Discharge max allowable working pressure is 1333.0 psi gauge at 250.0degf
Segmental hydrostatic test required. Inlet test pressure is 1500.0 psi gauge. Discharge test pressure is 2225.0 psi gauge.
Page 4 of 9
14845 West 64th Avenue | Arvada, Colorado 80007 USA | Phone: 1.303.425.0800 | Fax: 1.303.425.0896
SUNDYNE PUMP-PREDICTED PERFORMANCE DATA Units: US Customary Date:
Impeller Diameter (in): Max = 9, Rated = 8.24, Min = 8
Page 6 of 9
14845 West 64th Avenue | Arvada, Colorado 80007 USA | Phone: 1.303.425.0800 | Fax: 1.303.425.0896