Hasil Praktikum / Data Percobaan

Co - Current
Fluida Panas
Fluida masuk Fluida keluar
Laju alir
(1)* (2)* (1)* (2)*
33.33 60 40.69 49 40.58
38.22 60 40.65 51 40.6

Perhitungan
DATA 1
A Menghitung kalor
1. Fludia Dingin
t avg = 32.5 deg.C =
rho air (t1) = 1.014 gram/cm^3 =
rho air (t2) = 1.0132 gram/cm^3 =
rho air (avg) = 1.0136 gram/cm^3 =

Q debit = 31.18 cm^3/s =

Cp air pada t avg

Dari Tabel 2- 305 Perry


Suhu (K) Cp (Kj/mol K)
300 0.075320
310 0.075294

Cp pada t avg = 0.075306 kj/mol.K =


q dingin = 0.661101 kj/s
2. Fluida Panas
T avg = 54.5 deg.C =
rho air (T1) = 1.0056 gram/cm^3 =
rho air (T2) = 1.0012 gram/cm^3 =
rho air (avh) = 1.0034 kg/cm^3 =

Q debit = 33.33 cm^3/s =

Cp air pada T avg

Dari tabel 2- 305 perry


Suhu (K) Cp (Kj/mol K)
320 0.075317
330 0.075373

cp pada T avg = 0.075359 kj/mol.K =


q panas = 1.540156 kj/s

B. Menghitung koefisien perpan overall


Tabel Data suhu pada percobaan 1 atau 2 Co-Current
Hot Cold Diff.
60 High T 30 30
49 Low T 35 14

delta T LMTD = 20.9935 deg.C

Flow Area
Luas
A= 3532.5 cm^2 =
U= 0.0891 kj/s/.m^2

C. Menghitung efisiensi peralatan

> ditinjau dari fluida dingin


epsilon = 16.666667 %
> ditinjua dari fluida panas
epsilon = 36.666667 %

DATA 2
A Menghitung kalor
1. Fludia Dingin
t avg = 33 deg.C =
rho air (t1) = 1.0132 gram/cm^3 =
rho air (t2) = 1.0144 gram/cm^3 =
rho air (avg) = 1.0138 gram/cm^3 =

Q debit = 32.53 cm^3/s =

Cp air pada t avg

Dari Tabel 2- 305 Perry


Suhu (K) Cp (Kj/mol K)
300 0.075320
310 0.075294

Cp pada t avg = 0.075304 kj/mol.K =


q dingin = 0.827819 kj/s
2. Fluida Panas
T avg = 55.5 deg.C =
rho air (T1) = 1.004 gram/cm^3 =
rho air (T2) = 1.002 gram/cm^3 =
rho air (avh) = 1.003 kg/cm^3 =

Q debit = 38.22 cm^3/s =

Cp air pada T avg

Dari tabel 2- 305 perry


Suhu (K) Cp (Kj/mol K)
320 0.075317
330 0.075373

cp pada T avg = 0.0753646 kj/mol.K =


q panas = 1.444538 kj/s

B. Menghitung koefisien perpan overall


Tabel Data suhu pada percobaan 1 atau 2 Co-Current
Hot Cold Diff.
60 High T 36 24
51 Low T 30 21

delta T LMTD = 21.6404256133 deg.C

Flow Area
Luas
A= 3532.5 cm^2 =
U= 0.1083 kj/s/.m^2

C. Menghitung efisiensi peralatan

> ditinjau dari fluida dingin


epsilon = 20.000000 %
> ditinjua dari fluida panas
epsilon = 30.000000 %
Co - Current
Fluida Dingin
Fluida Masuk Fluida Keluar
Laju alir
(1)* (2)* (1)* (2)*
31.18 30 40.9 35 40.88
32.53 30 40.88 36 40.91

DATA 1

305.5 K
1014 kg/m^3
1013.2 kg/m^3
1013.6 kg/m^3

0.0000312 m^3/s

4.183650 kj/kg.K q panas-q dingin 0.879055

327.5 K
1005.6 kg/m^3
1001.2 kg/m^3
1003.4 kg/m^3

0.00003333 m^3/s
4.186611 kj/kg.K

0.3532500 m^3

DATA 2

306 K
1013.2 kg/m^3
1014.4 kg/m^3
1013.8 kg/m^3

0.0000325 m^3/s
4.183578 kj/kg.K 84

328.5 K
1004 kg/m^3
1002 kg/m^3
1003 kg/m^3

0.00003822 m^3/s

4.186922 kj/kg.K

0.3532500 m^3
Data Alat
Diameter Pipa Luar : ID : 16 cm OD : 17.3 cm
Diameter Pipa Dalam : ID : 2.3 cm OD : 3 cm
Panjang HE : 75 cm
Berat Piknometer : 15.55 gr
Volume Piknometer : 25 ml atau cm^3

BM air : 18 gr/mol
Hasil Praktikum / Data Percobaan
Counter - Current
Fluida Panas
Fluida masuk Fluida keluar
Laju alir
(1)* (2)* (1)* (2)*
23.45 60 40.41 47 40.61
25.55 60 40.45 46 40.67

Perhitungan
DATA 1
A Menghitung kalor
1. Fludia Dingin
t avg = 33.5 deg.C =
rho air (t1) = 0.7568 gram/cm^3 =
rho air (t2) = 0.758 gram/cm^3 =
rho air (avg) = 0.7574 gram/cm^3 =

Q debit = 24.21 cm^3/s =

Cp air pada t avg

Dari Tabel 2- 305 Perry


Suhu (K) Cp (Kj/mol K)
300 0.075320
310 0.075294

Cp pada t avg = 0.075303 kj/mol.K =


q dingin = 0.536980 kj/s
2. Fluida Panas
T avg = 53.5 deg.C =
rho air (T1) = 0.7404 gram/cm^3 =
rho air (T2) = 0.7484 gram/cm^3 =
rho air (avh) = 0.7444 kg/cm^3 =

Q debit = 23.45 cm^3/s =

Cp air pada T avg

Dari tabel 2- 305 perry


Suhu (K) Cp (Kj/mol K)
320 0.075317
330 0.075373

cp pada T avg = 0.0753534 kj/mol.K =


q panas = 0.949998 kj/s

B. Menghitung koefisien perpan overall


Tabel Data suhu pada percobaan 1 atau 2 Co-Current
Hot Cold Diff.
60 High T 37 23
47 Low T 30 17

delta T LMTD = 19.8490892355 deg.C

Flow Area
Luas
A= 3532.5 cm^2 =
U= 0.0766 kj/s/.m^2

C. Menghitung efisiensi peralatan

> ditinjau dari fluida dingin


epsilon = 23.333333 %
> ditinjua dari fluida panas
epsilon = 43.333333 %
DATA 2
A Menghitung kalor
1. Fludia Dingin
t avg = 33 deg.C =
rho air (t1) = 0.7584 gram/cm^3 =
rho air (t2) = 0.7592 gram/cm^3 =
rho air (avg) = 0.7588 gram/cm^3 =

Q debit = 25.06 cm^3/s =

Cp air pada t avg

Dari Tabel 2- 305 Perry


Suhu (K) Cp (Kj/mol K)
300 0.075320
310 0.075294

Cp pada t avg = 0.075304 kj/mol.K =


q dingin = 0.477318 kj/s
2. Fluida Panas
T avg = 53 deg.C =
rho air (T1) = 0.742 gram/cm^3 =
rho air (T2) = 0.7508 gram/cm^3 =
rho air (avh) = 0.7464 kg/cm^3 =

Q debit = 25.55 cm^3/s =

Cp air pada T avg

Dari tabel 2- 305 perry


Suhu (K) Cp (Kj/mol K)
320 0.075317
330 0.075373

cp pada T avg = 0.0753506 kj/mol.K =


q panas = 1.117647 kj/s

B. Menghitung koefisien perpan overall


Tabel Data suhu pada percobaan 1 atau 2 Co-Current
Hot Cold Diff.
60 High T 36 24
46 Low T 30 16

delta T LMTD = 19.730427699 deg.C

Flow Area
Luas
A= 3532.5 cm^2 =
U= 0.0685 kj/s/.m^2

C. Menghitung efisiensi peralatan

> ditinjau dari fluida dingin


epsilon = 20.000000 %
> ditinjua dari fluida panas
epsilon = 46.666667 %
Counter - Current
Fluida Dingin
Fluida Masuk Fluida Keluar
Laju alir
(1)* (2)* (1)* (2)*
24.21 30 40.82 37 40.85
25.06 30 40.86 36 40.88

DATA 1

306.5 K
756.8 kg/m^3
758 kg/m^3
757.4 kg/m^3

0.0000242 m^3/s

4.183506 kj/kg.K

326.5 K
740.4 kg/m^3
748.4 kg/m^3
744.4 kg/m^3

0.00002345 m^3/s
4.186300 kj/kg.K

0.3532500 m^3

DATA 2

306 K
758.4 kg/m^3
759.2 kg/m^3
758.8 kg/m^3

0.0000251 m^3/s
4.183578 kj/kg.K

326 K
742 kg/m^3
750.8 kg/m^3
746.4 kg/m^3

0.00002555 m^3/s

4.186144 kj/kg.K

0.3532500 m^3
Data Alat
Diameter Pipa Luar : ID : 16 cm OD : 17.3 cm
Diameter Pipa Dalam : ID : 2.3 cm OD : 3 cm
Panjang HE : 75 cm
Berat Piknometer : 21.9 gr
Volume Piknometer : 25 ml atau cm^3

BM air : 18 gr/mol