TSS-TS-TATA 0..996 EDC
3.4 Shut off test
Speed - min-1 (rpm) : - 3.8 Fuel deliveries
Check-back voltage (mV) : -
Delivery quantity ( x ) : - Speed - min-1 (rpm) : 950
in cm³ /500 strokes Check-back voltage (mV) : 3600
Shut of solenoid (ELAB) voltage : - Delivery quantity ( x ) : (47.25 - 50.75)
TV % : - in cm³ /500 strokes
3.5 Timer travel TV % : 0
Speed - min-1 (rpm) : 950 Maximum spread in cm³ (∆ ) : 1.8
Check-back voltage (mV) : 3600 Speed - min-1 (rpm) : 500
Timer travel in mm : (12.1 - 13.3) Check-back voltage (mV) : 3030
TV % : 0 Delivery quantity ( x ) : 47.25 - 51.25
Speed - min-1 (rpm) : in cm³ /500 strokes
Check-back voltage (mV) : - TV % : 0
Timer travel in mm : -
TV % : - Speed - min-1 (rpm) : 1200
Speed - min-1 (rpm) : 1200 Check-back voltage (mV) : 3950
Check-back voltage (mV) : 3950 Delivery quantity ( x ) : 50.25 - 53.75
Timer travel in mm : 0 - 1.0 in cm³ /500 strokes
TV % : 100 TV % : 0
Speed - min-1 (rpm) : - Speed - min-1 (rpm) : -
Check-back voltage (mV) : - Check-back voltage (mV) : -
Timer travel in mm : - Delivery quantity ( x ) : -
TV % : - in cm³ /500 strokes
36 Vane pump pressure TV % : -
Speed - min-1 (rpm) : 950 Speed - min-1 (rpm) : -
Check-back voltage (mV) : 3600 Check-back voltage (mV) : -
Vane pump pressure in bar : (9.0 - 10.6) Delivery quantity ( x ) : -
TV % : 0 in cm³ /500 strokes
Speed - min-1 (rpm) : 300 TV % : -
Check-back voltage (mV) : 3950 Speed - min-1 (rpm) : -
Vane pump pressure in bar : 6.2 - 7.8 Check-back voltage (mV) : -
TV % : 0 Delivery quantity ( x ) : -
3.7 Overflow quantity in cm³ /500 strokes
Speed - min-1 (rpm) : 1200 TV % : -
Check-back voltage (mV) : 3950
Overflow quantity : 116.0 - 173.0 3.8 Solenoid
in cm³ /10 seconds Rated voltage : 12 V
TV % : 0
Speed - min-1 (rpm) : 500 4. ASSEMBLY AND SETTING DIMENSIONS
Check-back voltage (mV) : 3030 Description Specification
Overflow quantity : 116.0 - 162.0 K : 3.66 -3.74 mm
in cm³ /10 seconds KF : 8.2 - 8.6 mm
TV % : 0
Caution: Shut of solenoid (ELAB) to be connected with 12 V always unless specifically
mentioned while testing the pump.
Note: 3 X : Average of the cylinders
1 .Sl. No. of the operations indicate the sequence of operation.
2 .Values given in brackets are overchecking values
Applicable only for BOSCH/MICO test benches (~ 11 kW). 071009