You are on page 1of 123

CONSTRUCTION ESTIMATE CALCULATOR

(BY ENGR. RONALD JOHN R. CAJILLA)


(JUST INPUT THE DATA INSIDE THE YELLOW CELL)
ITEM - I CONCRETING WORKS
A. DETERMINING THE VOLUME OF A CONCRETE
FOOTING FORMULA: VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length L (M) 1.20 M
Enter Width W (M) 1.20 M
W Enter Thickness T (M) 0.40 M
T
TOTAL VOLUME OF CONCRETE: 0.58 CU.M.
Number of Footing Units 82.00 Units
TOTAL VOLUME OF CONCRETE: 47.23 CU.M.
# OF CEMENT BAGS 426.00 BAGS
VOL. OF SAND CU.M. 23.70 CU.M.
L
VOL. OF 3/4" GRAVEL CU.M. 47.30 CU.M.

WALL FOOTING

T
L = LENGTH
W
FORMULA: VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length LT (M) 156.20 M
Enter Width W (M) 0.40 M
Enter Thickness T (M) 0.30 M
TOTAL VOLUME OF CONCRETE: 18.74 CU.M.
# OF CEMENT BAGS 169.00 BAGS
VOL. OF SAND CU.M. 9.40 CU.M.
LT = TOTAL LENGTH/PERIMETER VOL. OF 3/4" GRAVEL CU.M. 18.80 CU.M.

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 5.00 M
T Enter Width W (M) 5.00 M
W
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 5.00 CU.M.
# OF CEMENT BAGS 45.00 BAGS
L VOL. OF SAND CU.M. 2.50 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 5.00 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


FLOOR SLAB - BY AREA
FORMULA: VOLUME = Floor Area* T
CLASS A CONCRETE MIX
T Enter Floor Area A (SQ.M) 890.08 SQ.M
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
TOTAL VOLUME OF CONCRETE: 178.02 CU.M.
# OF CEMENT BAGS 1,603.00 BAGS
Area
VOL. OF SAND CU.M. 89.10 CU.M.
9 0.5 1 VOL. OF 3/4" GRAVEL CU.M. 178.10 CU.M.

CONCRETE COLUMNS COLUMN DIMENSIONS:


RECTANGULAR
W1 Width 1 0.40 M
Width 2 0.40 M

W2
FORMULA: VOLUME = H * W1 * W2
H CLASS A CONCRETE MIX
Enter Height L (M) 16.10 M
VOLUME OF CONCRETE FOR EACH COLUME: 2.58 CU.M.
Number of Columns Units 82.00 Units
TOTAL VOLUME OF CONCRETE: 211.23 CU.M.
# OF CEMENT BAGS 1,902.00 BAGS
VOL. OF SAND CU.M. 105.70 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 211.30 CU.M.

CONCRETE COLUMNS COLUMN DIMENSIONS:


CIRCULAR
D1 Diameter - M

AreaCirc - SQ.M.

FORMULA: VOLUME = H * AreaCirc


H CLASS A CONCRETE MIX
Enter Height L (M) 3.00 M
VOLUME OF CONCRETE EACH COLUMN: - CU.M.
Number of Columns Units - Units
TOTAL VOLUME OF CONCRETE: - CU.M.
# OF CEMENT BAGS - BAGS
VOL. OF SAND CU.M. - CU.M.
VOL. OF 3/4" GRAVEL CU.M. - CU.M.

(BY ENGR. RONALD JOHN R. CAJILLA)

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


CONCRETE BEAMS

FORMULA: VOLUME = LT * W * D
CLASS A CONCRETE MIX
LT EnterTotal Length LT (M) 1,440.20 M
Enter Width W (M) 0.30 M
BEAM DIMENSIONS: Enter Depth D (M) 0.40 M
TOTAL VOLUME OF CONCRETE: 172.82 CU.M.
D
# OF CEMENT BAGS 1,556.00 BAGS
VOL. OF SAND CU.M. 86.50 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 172.90 CU.M.

CONCRETE STAIRS

TR Enter Riser Height RH (M) 0.20 M


W Enter Tread Run TR (M) 0.20 M
Enter Stair Width W (M) 1.80 M
RH Enter # of Steps N 9.00 Steps
Enter Stringer Thickness TS (M) 0.14 M

0.32 0.65 0.97

TOTAL VOLUME OF CONCRETE: 0.97 CU.M.


# OF CEMENT BAGS 9.00 BAGS
TS VOL. OF SAND CU.M. 0.50 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 1.00 CU.M.

CONCRETE STAIRS

TR Enter Riser Height RH (M) 0.20 M


W Enter Tread Run TR (M) 0.20 M
Enter Stair Width W (M) 3.15 M
RH Enter # of Steps N 3.00 Steps
Enter Stringer Thickness TS (M) 0.14 M

0.19 0.38 0.57

TOTAL VOLUME OF CONCRETE: 0.57 CU.M.


# OF CEMENT BAGS 6.00 BAGS
TS VOL. OF SAND CU.M. 0.30 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 0.60 CU.M.

CONCRETE STAIRS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


TR Enter Riser Height RH (M) 0.20 M
W Enter Tread Run TR (M) 0.20 M
Enter Stair Width W (M) 12.00 M
RH N
Enter # of Steps 3.00 Steps
Enter Stringer Thickness TS (M) 0.14 M

0.72 1.44 2.16

TOTAL VOLUME OF CONCRETE: 2.16 CU.M.


# OF CEMENT BAGS 20.00 BAGS
TS VOL. OF SAND CU.M. 1.10 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 2.20 CU.M.

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


CONSTRUCTION ESTIMATE CALCULATOR
(BY ENGR. RONALD JOHN R. CAJILLA)
(JUST INPUT THE DATA INSIDE THE YELLOW CELL)
ITEM - I CONCRETING WORKS
A. DETERMINING THE VOLUME OF A CONCRETE

WALL FOOTING

T
L = LENGTH
W
FORMULA: VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length LT (M) 198.60 M
Enter Width W (M) 0.35 M
Enter Thickness T (M) 0.30 M
TOTAL VOLUME OF CONCRETE: 20.85 CU.M.
# OF CEMENT BAGS 188.00 BAGS
VOL. OF SAND CU.M. 10.50 CU.M.
LT = TOTAL LENGTH/PERIMETER VOL. OF 3/4" GRAVEL CU.M. 20.90 CU.M.

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 4.00 M
T Enter Width W (M) 4.00 M
W Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 3.20 CU.M.
# OF CEMENT BAGS 29.00 BAGS
L VOL. OF SAND CU.M. 1.60 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 3.20 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)
FLOOR SLAB FORMULA: VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length L (M) 4.00 M
Enter Width W (M) 1.20 M
W T
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 0.96 CU.M.
# OF CEMENT BAGS 9.00 BAGS
L VOL. OF SAND CU.M. 0.50 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 1.00 CU.M.

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 5.00 M
T Enter Width W (M) 1.50 M
W Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 1.50 CU.M.
# OF CEMENT BAGS 14.00 BAGS
L VOL. OF SAND CU.M. 0.80 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 1.50 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 5.00 M
T Enter Width W (M) 1.00 M
W Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 1.00 CU.M.
# OF CEMENT BAGS 9.00 BAGS
L VOL. OF SAND CU.M. 0.50 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 1.00 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 4.00 M
Enter Width W (M) 2.50 M
W T
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 2.00 CU.M.
# OF CEMENT BAGS 18.00 BAGS
L VOL. OF SAND CU.M. 1.00 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 2.00 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 5.00 M
Enter Width W (M) 3.00 M
W T
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


TOTAL VOLUME OF CONCRETE: 3.00 CU.M.
# OF CEMENT BAGS 27.00 BAGS
L VOL. OF SAND CU.M. 1.50 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 3.00 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 5.00 M
T Enter Width W (M) 4.00 M
W Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 4.00 CU.M.
# OF CEMENT BAGS 36.00 BAGS
L VOL. OF SAND CU.M. 2.00 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 4.00 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 5.00 M
Enter Width W (M) 2.50 M
W T
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 2.50 CU.M.
# OF CEMENT BAGS 23.00 BAGS
L VOL. OF SAND CU.M. 1.30 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 2.50 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB FORMULA: VOLUME = L * W * T


CLASS A CONCRETE MIX
Enter Length L (M) 3.00 M
T Enter Width W (M) 2.50 M
W Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
9 0.5 1
TOTAL VOLUME OF CONCRETE: 1.50 CU.M.
# OF CEMENT BAGS 14.00 BAGS
L VOL. OF SAND CU.M. 0.80 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 1.50 CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB - BY AREA


FORMULA: VOLUME = Floor Area* T

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


CLASS A CONCRETE MIX
T Enter Floor Area A (SQ.M) 932.70 SQ.M
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
TOTAL VOLUME OF CONCRETE: 186.54 CU.M.
# OF CEMENT BAGS 1,679.00 BAGS
Area VOL. OF SAND CU.M. 93.30 CU.M.
9 0.5 1 VOL. OF 3/4" GRAVEL CU.M. 186.60 CU.M.

CONCRETE BEAMS

FORMULA: VOLUME = LT * W * D
CLASS A CONCRETE MIX
EnterTotal Length LT (M) 80.40 M
LT
Enter Width W (M) 0.20 M
BEAM DIMENSIONS: Enter Depth D (M) 0.40 M
D TOTAL VOLUME OF CONCRETE: 6.43 CU.M.
# OF CEMENT BAGS 58.00 BAGS
VOL. OF SAND CU.M. 3.30 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 6.50 CU.M.
W

CONCRETE BEAMS

FORMULA: VOLUME = LT * W * D
CLASS A CONCRETE MIX
EnterTotal Length LT (M) 628.00 M
LT
Enter Width W (M) 0.20 M
BEAM DIMENSIONS: Enter Depth D (M) 0.30 M
D TOTAL VOLUME OF CONCRETE: 37.68 CU.M.
# OF CEMENT BAGS 340.00 BAGS
VOL. OF SAND CU.M. 18.90 CU.M.
VOL. OF 3/4" GRAVEL CU.M. 37.70 CU.M.
W

(BY ENGR. RONALD JOHN R. CAJILLA)

FLOOR SLAB - BY AREA


FORMULA: VOLUME = Floor Area* T
CLASS A CONCRETE MIX
T Enter Floor Area A (SQ.M) 955.76 SQ.M
Enter Thickness T (M) 0.20 M
Enter Concrete Mix Design (CLASS) AA, A,or B A 1:2:4
TOTAL VOLUME OF CONCRETE: 191.15 CU.M.
# OF CEMENT BAGS 1,721.00 BAGS
Area

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Area VOL. OF SAND CU.M. 95.60 CU.M.
9 0.5 1 VOL. OF 3/4" GRAVEL CU.M. 191.20 CU.M.

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
ITEM - II MASONRY WORKS
A. DETERMINING THE NUMBER OF CONCRETE HOLLOW BLOCKS USED
B. DETERMINING THE NUMBER OF CEMENT & VOLUME OF SAND FOR MORTAR & PLASTERING
Enter Wall Height H (M) 12.80 M
Enter Wall Length L (M) 1,306.60 M
Enter Area of Window AW (SQ.M.) 760.52 SQ.M
Enter Area of Door AD (SQ.M) 260.16 SQ.M.
Breakage Allowance % - %

TOTAL WALL AREA: 15,703.80 SQ.M.


TOTAL NUMBER OF CHB: 196,298.00 PCS

MORTAR USING 4" CHB


# OF CEMENT BAGS 8,245.00 BAGS
VOL. OF SCREENED SAND CU.M. 687.90 CU.M.
MORTAR USING 6" CHB
# OF CEMENT BAGS 15,908.00 BAGS
VOL. OF SCREENED SAND CU.M. 1,325.50 CU.M.

PLASTER : 16mm thk Mix: 1:2


One face ofthe wall only
# OF CEMENT BAGS 4,523.00 BAGS
VOL. OF FINE SAND CU.M. 251.30 CU.M.
PLASTER : 16mm thk Mix: 1:2
Two faces of the wall
# OF CEMENT BAGS 9,046.00 BAGS
VOL. OF FINE SAND CU.M. 502.60 CU.M.

RIPRAPING WORKS L
W1 Enter Height H (M) M
Enter Width 1 W1 (M) M
Enter Width 2 W2 (M) M
Enter Length L (M) M

Using: Stones ranging from 15 to 25 kgs with atleast


H 50% of stones weighing more than 20 kgs, &
Class A Mixture

TOTAL SIDE AREA: - SQ.M.


TOTAL VOLUME: - CU.M.
VOL. OF BOULDERS CU.M. - CU.M.
# OF CEMENT BAGS - BAGS
VOL. OF SAND CU.M. - CU.M.
W2

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
ITEM - III STEEL REINFORCEMENT
LENGTH OF REINFORCING BARS FOR CHB IN METERS
LENGTH
VERT.
LENGTH
OF vertical spacing
OF SPACEING
SPACING HORIZON
VERTICAL LAYER
(CM) TAL
REIN./SQ.
REIN./

40 2.93 2 Layers 3.300

60 2.13 3 Layers 2.150


spacing
layer
80 1.6 4 Layers 1.720

DETERMINING THE NUMBER OF BARS USED ground

Enter Wall Height H (M) 21.25 M


Enter Wall Length L (M) 342.68 M
Enter wall openings SQ.M 228.82 SQ.M.
Enter Constant Factor VERTICAL 2.13 60cm
Enter Constant Factor HORIZONTAL 2.15 3 layers
TOTAL WALL AREA: 7,053.18 SQ.M.
# OF VERTICAL BARS USED: 2,504.00 PCS @ 6M 16
# OF HORIZONTAL BARS USED: 2,528.00 PCS @ 6M 12
#16 TIE WIRE USED: 331.50 Kgs

FOOTING MATTING
Enter Footing Length L (M) 1.20 M
Enter Footing Width W (M) 1.20 M
Enter # of Bars along L # 7.00 Pcs
Enter Number of Bars along W # 7.00 Pcs
L Enter Number of Footing # 4.00 Units
Enter Clear Cover Cc (M) 0.075 M
Note: Standard Clear Cover for footing =0.05m to 0.075m
# of Bars
per Side Net. Length along L 1.05 M
W Net. Length along W 1.05 M
# OF REIN. BARS USED: 11.20 LHS 36
#16 TIE WIRE USED: 1.50 Kgs

Clear
Cover
FOOTING MATTING
Enter Footing Length L (M) 1.20 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Enter Footing Width W (M) 1.20 M
Enter # of Bars along L # 9.00 Pcs
Enter Number of Bars along W # 9.00 Pcs
L Enter Number of Footing # 4.00 Units
Enter Clear Cover Cc (M) 0.075 M
Note: Standard Clear Cover for footing =0.05m to 0.075m
# of Bars
per Side Net. Length along L 1.05 M
W Net. Length along W 1.05 M
# OF REIN. BARS USED: 14.40 LHS 36
#16 TIE WIRE USED: 2.50 Kgs

Clear
Cover

BY: ENGR. RONALD JOHN R. CAJILLA


WALL FOOTING REINFORCEMENT
Enter Wall Footing Width W (M) M
Enter Wall Footing Total Length LT (M) M
Enter Spacing of Tie Bars for Wall footing (M) M

Total # of Ties: #DIV/0! PCS


Total # of Horizontal Bars Used: - LHS
T
Overall Total # of Bars used: #DIV/0! LHS
#16 TIE WIRE USED: #DIV/0! Kgs
W

Tie Bars
Spacing

LT = TOTAL LENGTH/PERIMETER

RECTANGULAR COLUMN REINFORCEMENT

D1
H

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


D1
H

Clear Cover for


columns =
D2 0.40m

Enter Column Height H (M) 18.85 M


Enter Number of Columns # 6.00 Units
Enter Reinforcement Bar Diameter required Ø 20.00 mm
Enter Column Dimension D1 (M) 0.50 M
Enter Column Dimension D2 (M) 0.50 M

Enter Number of Vertical Bars (M) 12.00 PCS


Enter Stirrup bar diameter required
End Hook/ L hook Ø 10.00 mm
Enter Stirrups Spacing (M) 0.15 M

BY: ENGR. RONALD JOHN R. CAJILLA


1 0.35
Use End Hook: 0.350 M
Total length of each bars should be more than or equal to: 20.00 M
Total Number of Vertical Bars @ 6M: 72.00 LHS 20
6
Cut Length of each stirrups: 1.90 M
Number of Stirrups per Column: 137.00 PCS
Total Number of Bars used for stirrups @ 6M : 261.00 LHS 10

#16 TIE WIRE USED: 18.70 Kgs

CIRCULAR COLUMN REINFORCEMENT

Enter Column Height H (M) M


Enter Number of Columns # Units
Enter Reinforcement Bar Diameter required Ø mm
Enter Column Diameter D1 (M) M

D1 Enter Number of Vertical Bars (M) PCS


Enter Stirrup bar diameter required Ø mm
Enter Stirrups Spacing (M) M

#VALUE! Use DSB 12mm to 25mm only


Use EndUse DSB 12mm to 25mm only
Hook: M
Total length of each bars should be more than or equal to: #VALUE! M
Total Number of Vertical Bars @ 6M: #VALUE! LHS
#VALUE! Circular Stirrups
Cut Length of each stirrups: (0.30) M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of Stirrups per Column: #DIV/0! M
Total Number of Bars required for stirrups @ 6M : #DIV/0! LHS
#16 TIE WIRE required: #DIV/0! Kgs

Spiral Stirrups
Cut Length of each stirrups: (0.30) M
Number of Stirrup Loops per Column: #DIV/0! M
Total Number of Bars required for stirrups @ 6M : #DIV/0! LHS
#16 TIE WIRE required: #DIV/0! Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.05 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 7.00 PCS
#16 TIE WIRE USED: 0.60 Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.42 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 6.00 PCS
#16 TIE WIRE USED: 0.60 Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


b1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.59 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Colum
n
Width TOP BARS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 8.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 7.00 PCS
#16 TIE WIRE USED: 0.80 Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


B2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.05 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 7.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
B2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 3.35 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 5.00 PCS
#16 TIE WIRE USED: 0.50 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.52 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 6.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 2.29 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 4.00 PCS
#16 TIE WIRE USED: 0.50 Kgs
g1
BEAM REINFORCEMENT (TWO BAYS) CONTINUOUS BEAM
Enter Beam Length 1 L1 (M) 6.65 M
Enter Beam Length 2 L2 (M) 2.82 M
Enter Beam Width W (M) 0.20 M
L1 L2 Enter Beam Depth D (M) 0.40 M
Enter Column Width Max Cw(M) 0.50 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

- -
Web Bars - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W

Enter Stirrup Bars Diameter required: 10.00 mm


Enter Stirrup Spacing: 0.20 M
L = Span1 L = Span2
L/4 L/4

0.15 L
0.15 L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 5.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars used as Continuous Bars 5.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars required as main bars 14.00 PCS
Number of 0mm bars required as web bars - PCS
Number of 10mm bars required as stirrups 2.00 PCS
#16 TIE WIRE USED: 1.70 Kgs
g1
BEAM REINFORCEMENT (TWO BAYS) CONTINUOUS BEAM
Enter Beam Length 1 L1 (M) 6.21 M
Enter Beam Length 2 L2 (M) 6.36 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Enter Beam Width W (M) 0.20 M
L1 L2 Enter Beam Depth D (M) 0.40 M
Enter Column Width Max Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
L = Span1 Enter Stirrup Spacing: 0.20 M
L = Span2
L/4 L/4

0.15 L
0.15 L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 6.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars used as Continuous Bars 6.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars required as main bars 16.00 PCS
Number of 0mm bars required as web bars - PCS
Number of 10mm bars required as stirrups 2.00 PCS
#16 TIE WIRE USED: 2.20 Kgs
ONE WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 3.764 0.474
12.500 3.062 0.316
15.000 2.584 0.228
17.500 2.232 0.168
20.000 1.980 0.132
22.200 1.786 0.110
25.000 1.627 0.089

W T Enter Length L (M) 5.81 M


Enter Width W (M) 2.82 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 1.980


# of Ties #16 Constant factor c 0.132
L
# OF STEEL BARS required PCS @ 6M 33.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA
ONE WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 3.764 0.474
12.500 3.062 0.316
15.000 2.584 0.228
17.500 2.232 0.168
20.000 1.980 0.132
22.200 1.786 0.110
25.000 1.627 0.089

W T Enter Length L (M) 5.99 M


Enter Width W (M) 2.82 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 1.980


# of Ties #16 Constant factor c 0.132
L # OF STEEL BARS required PCS @ 6M 34.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA
ONE WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 3.764 0.474
12.500 3.062 0.316
15.000 2.584 0.228
17.500 2.232 0.168
20.000 1.980 0.132
22.200 1.786 0.110
25.000 1.627 0.089

W T Enter Length L (M) 7.21 M


Enter Width W (M) 2.00 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 1.980


# of Ties #16 Constant factor c 0.132
L # OF STEEL BARS required PCS @ 6M 29.00 PCS
# OF #16 TIE WIRE required KGS 2.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

W T Enter Length b1 (M) 6.65 M


b2 (M) 5.59 M
Enter height h (M) 2.89 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L
# OF STEEL BARS required PCS @ 6M 42.00 PCS
# OF #16 TIE WIRE required KGS 4.00 KGS

BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

W T Enter Length L (M) 2.89 M


Enter Width W (M) 5.05 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 35.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS

BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

W T Enter Length L (M) 2.92 M


Enter Width W (M) 5.05 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 35.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS

BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

W T Enter Length b1 (M) 4.52 M


b2 (M) 5.59 M
Enter height h (M) 2.92 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 35.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

T Enter Length b1 (M) 3.42 M


W
b2 (M) 4.52 M
Enter height h (M) 2.99 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 29.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

T Enter Length b1 (M) 3.42 M


W
b2 (M) 2.32 M
Enter height h (M) 2.99 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 21.00 PCS
# OF #16 TIE WIRE required KGS 2.00 KGS

CONCRETE STAIRS
Enter Riser Height RH (M) 0.20 M
TR Enter Tread Run TR (M) 0.30 M
W Enter Stair Width W (M) 1.60 M
Enter # of Steps N 11.00 Steps
RH TS (M)
Enter Stringer Thickness 0.21 M
0.53 0.36 0.89
Enter Spacing (M)
0.20
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.20 10
Enter Stringer Lateral Bar diameter (mm)
12 TS
Enter Spacing (M)
0.20
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.20 10
Enter Stringer Horizontal Bar diameter (mm)
12
Number of 10 mm Lateral Bars required @ Steps PCS @ 6M 12.00 PCS
Number of 10 mm Horizontal Bars required @ Steps PCS @ 6M 9.00 PCS
Number of 12 mm Lateral Bars required @ Stringer PCS @ 6M 9.00 PCS
Number of 12 mm Horizontal Bars required @ Stringer PCS @ 6M 4.00 PCS
# OF #16 TIE WIRE USED KGS 2.00 KGS

NOTES: DOWELS FOR LATERAL BARS ARE ALREADY INCLUDED IN THE ESTIMATES

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


FOR STAIRS LANDINGS YOU MAY USE THE SLAB REINFORCEMENT CALCULATOR

BY: ENGR. RONALD JOHN R. CAJILLA


CONCRETE STAIRS
Enter Riser Height RH (M) 0.20 M
TR Enter Tread Run TR (M) 0.30 M
W Enter Stair Width W (M) 1.60 M
Enter # of Steps N 5.00 Steps
RHEnter Stringer Thickness TS (M) 0.21 M
0.24 0.36 0.60
Enter Spacing (M)
0.20
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.20 10
Enter Stringer Lateral Bar diameter (mm)
12 TS
Enter Spacing (M)
0.20
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.20 10
Enter Stringer Horizontal Bar diameter (mm)
12
Number of 10 mm Lateral Bars required @ Steps PCS @ 6M 7.00 PCS
Number of 10 mm Horizontal Bars required @ Steps PCS @ 6M 4.00 PCS
Number of 12 mm Lateral Bars required @ Stringer PCS @ 6M 5.00 PCS
Number of 12 mm Horizontal Bars required @ Stringer PCS @ 6M 2.00 PCS
# OF #16 TIE WIRE USED KGS 1.00 KGS

NOTES: DOWELS FOR LATERAL BARS ARE ALREADY INCLUDED IN THE ESTIMATES
FOR STAIRS LANDINGS YOU MAY USE THE SLAB REINFORCEMENT CALCULATOR

BY: ENGR. RONALD JOHN R. CAJILLA

CONCRETE CANAL

TOP OPENING WIDTH


Stiffener

Enter Canal Total Length (M) M


Enter Canal Total Height (M) M
L TOTAL HEIGHT

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


CANAL TOTAL HEIGHT Enter Top Opening Width (M) M
Enter Bottom Opening width (M) M
BOTTOM
OPENING Enter Canal Flooring Bottom Width (M) M
WIDTH Enter Canal Flooring Thickness (M) M

Enter # of layers of CHB used (1 Side) Layer layers


TC Enter Size of CHB required 4"=6"0.10,
F
= 0.15 M
CHB Breakage % allowance % %
Calc. U bar length 0.20
CANAL
PCS
FLOORING Enter # of Horizonal Barsfor Walling (2 sides) PCS
BOTTOM PCS
Enter # of Horizonal Bars for flooring PCS
WIDTH (M)
Enter U bar spacing M
ERROR 0.5 1
CONCRETING Enter Concrete Mix Design (CLASS) A or B AorB
Canal Flooring Total Volume - cu.m. #VALUE! #VALUE!
Canal Top Stiffener Total Volume - cu.m. - -
# of Bags cement #VALUE! BAGS
Volume of Sand #VALUE! CU.M.
Volume of 3/4 Gravel - CU.M.
MASONRY
# of CHB used - PCS
AREA 0
MORTAR USING 4" CHB
# OF CEMENT BAGS - BAGS
VOL. OF SCREENED SAND CU.M. - CU.M.
MORTAR USING 6" CHB
# OF CEMENT BAGS - BAGS
VOL. OF SCREENED SAND CU.M. - CU.M.

PLASTER : 16mm thk Mix: 1:2


One face ofthe wall only
# OF CEMENT BAGS - BAGS
VOL. OF FINE SAND CU.M. - CU.M.

BY: ENGR. RONALD JOHN R. CAJILLA


REINFORCEMENTS
# of Horizontal Bars Used at CHB Wall - PCS @ 6M
# of Horizontal Bars Used at Flooring - PCS @ 6M
# U Bars #DIV/0! PCS
# Bars Used for U Bars #DIV/0! PCS @ 6M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


d1 6.405
d2 4.41
d3 2.1
d4 2.1
d5 2.1
d6 2.1
d7 1.26
d8 2.1
w1 54.94 13.4 4.1
w2 0.55 0.5 1.1
w3 44.486 15.08 2.95

1st floor 3
54.51
2nd floor 3.35
49.85
3rd & 4th &5th 3.35
49.85
roof deck 3.35
21.99
0.5
40.0324
roof plan 1
26.75

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


85.00 8.70
114.00

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 6.19 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Column Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 11.00 PCS
#16 TIE WIRE USED: 0.70 Kgs
g1

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 6.38 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W (M)
L(beam to beam) Enter Beam Width 0.30 M
Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Column Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 10mm bars used as stirrups 11.00 PCS
#16 TIE WIRE USED: 0.70 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 6.65 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 11.00 PCS
#16 TIE WIRE USED: 0.70 Kgs
g1

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 1.99 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W (M)
L(beam to beam) Enter Beam Width 0.30 M
Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 10mm bars used as stirrups 5.00 PCS
#16 TIE WIRE USED: 0.40 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 2.82 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 6.00 PCS
#16 TIE WIRE USED: 0.50 Kgs
g1

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 0.85 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W (M)
L(beam to beam) Enter Beam Width 0.30 M
Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 1.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 1.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 3.00 PCS
Number of 0mm bars used as web bars \ PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 10mm bars used as stirrups 4.00 PCS
#16 TIE WIRE USED: 0.40 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.05 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 9.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.42 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 8.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
g1

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 6.38 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W (M)
L(beam to beam) Enter Beam Width 0.30 M
Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 10mm bars used as stirrups 11.00 PCS
#16 TIE WIRE USED: 0.70 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.42 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 8.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
g1

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.41 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W (M)
L(beam to beam) Enter Beam Width 0.30 M
Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 10mm bars used as stirrups 8.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 7.64 M


Enter Beam Width W (M) 0.30 M
L(beam to beam) Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

Enter Stirrup Spacing: 0.20 M


L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars \ PCS
Number of 10mm bars used as stirrups 12.00 PCS
#16 TIE WIRE USED: 0.80 Kgs
g1

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.70 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W (M)
L(beam to beam) Enter Beam Width 0.30 M
Enter Beam Depth D (M) 0.50 M
Enter Column Width Cw(M) 0.50 M
Top Bars # of Bars # of Non-
Continuou Continuou Size of Bars Units
s s Bars
D
Top Bars 2 1 20.00 mm
Web Bars

Web Bars - - - mm
Bottom Bars
Note: put "0" zero if web bars not applicable
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Colum
n
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars \ PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 10mm bars used as stirrups 9.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
g1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
ITEM - III STEEL REINFORCEMENT
LENGTH OF REINFORCING BARS FOR CHB IN METERS
LENGTH
VERT.
LENGTH
OF vertical spacing
OF SPACEING
SPACING HORIZON
VERTICAL LAYER
(CM) TAL
REIN./SQ.
REIN./

40 2.93 2 Layers 3.300

60 2.13 3 Layers 2.150


spacing
layer
80 1.6 4 Layers 1.720

DETERMINING THE NUMBER OF BARS USED

Enter Wall Height H (M) 19.75 M


Enter Wall Length L (M) 227.45 M
Enter wall openings SQ.M 75.18 SQ.M.
Enter Constant Factor VERTICAL 2.13 60cm
Enter Constant Factor HORIZONTAL 2.15 3 layers
TOTAL WALL AREA: 4,417.04 SQ.M.
# OF VERTICAL BARS USED: 1,569.00 PCS @ 6M 16
# OF HORIZONTAL BARS USED: 1,583.00 PCS @ 6M 12
#16 TIE WIRE USED: 207.70 Kgs

FOOTING MATTING
Enter Footing Length L (M) 1.00 M
Enter Footing Width W (M) 1.00 M
Enter # of Bars along L # 11.00 Pcs
Enter Number of Bars along W # 11.00 Pcs
L Enter Number of Footing # 1.00 Units
Enter Clear Cover Cc (M) 0.075 M
Note: Standard Clear Cover for footing =0.05m to 0.075m
# of Bars
per Side Net. Length along L 0.85 M
W Net. Length along W 0.85 M
# OF REIN. BARS USED: 3.67 LHS 36
#16 TIE WIRE USED: 1.00 Kgs

Clear
Cover

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
WALL FOOTING REINFORCEMENT
Enter Wall Footing Width W (M) M
Enter Wall Footing Total Length LT (M) M
Enter Spacing of Tie Bars for Wall footing (M) M

Total # of Ties: #DIV/0! PCS


Total # of Horizontal Bars Used: - LHS
T
Overall Total # of Bars used: #DIV/0! LHS
#16 TIE WIRE USED: #DIV/0! Kgs
W

Tie Bars
Spacing

LT = TOTAL LENGTH/PERIMETER

RECTANGULAR COLUMN REINFORCEMENT

D1
H

Clear Cover for


columns =
D2 0.40m

Enter Column Height H (M) 15.75 M


Enter Number of Columns # 5.00 Units
Enter Reinforcement Bar Diameter required Ø 16.00 mm
Enter Column Dimension D1 (M) 0.50 M
Enter Column Dimension D2 (M) 0.50 M

Enter Number of Vertical Bars (M) 12.00 PCS


Enter Stirrup bar diameter required Ø 10.00 mm
End Hook/ L hook
Enter Stirrups Spacing (M) 0.15 M

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


1 0.25
Use End Hook: 0.250 M
Total length of each bars should be more than or equal to: 16.70 M
Total Number of Vertical Bars @ 6M: 60.00 LHS
6
Cut Length of each stirrups: 1.90 M
Number of Stirrups per Column: 117.00 PCS
Total Number of Bars used for stirrups @ 6M : 186.00 LHS

#16 TIE WIRE USED: 13.30 Kgs


RECTANGULAR COLUMN REINFORCEMENT

D1
H

Clear Cover for


columns =
D2 0.40m

Enter Column Height H (M) 18.85 M


Enter Number of Columns # 6.00 Units
Enter Reinforcement Bar Diameter required Ø 20.00 mm
Enter Column Dimension D1 (M) 0.50 M
Enter Column Dimension D2 (M) 0.50 M

Enter Number of Vertical Bars (M) 12.00 PCS


Enter Stirrup bar diameter required Ø 10.00 mm
End Hook/ L hook
Enter Stirrups Spacing (M) 0.15 M

BY: ENGR. RONALD JOHN R. CAJILLA


1 0.35
Use End Hook: 0.350 M
Total length of each bars should be more than or equal to: 20.00 M
Total Number of Vertical Bars @ 6M: 72.00 LHS
6
Cut Length of each stirrups: 1.90 M
Number of Stirrups per Column: 137.00 PCS
Total Number of Bars used for stirrups @ 6M : 261.00 LHS

#16 TIE WIRE USED: 18.70 Kgs

CIRCULAR COLUMN REINFORCEMENT

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Enter Column Height H (M) M
Enter Number of Columns # Units
Enter Reinforcement Bar Diameter required Ø mm
Enter Column Diameter D1 (M) M

D1 Enter Number of Vertical Bars (M) PCS


Enter Stirrup bar diameter required Ø mm
Enter Stirrups Spacing (M) M

#VALUE! Use DSB 12mm to 25mm only


Use EndUse DSB 12mm to 25mm only
Hook: M
Total length of each bars should be more than or equal to: #VALUE! M
Total Number of Vertical Bars @ 6M: #VALUE! LHS
#VALUE! Circular Stirrups
Cut Length of each stirrups: (0.30) M
Number of Stirrups per Column: #DIV/0! M
Total Number of Bars required for stirrups @ 6M : #DIV/0! LHS
#16 TIE WIRE required: #DIV/0! Kgs

Spiral Stirrups
Cut Length of each stirrups: (0.30) M
Number of Stirrup Loops per Column: #DIV/0! M
Total Number of Bars required for stirrups @ 6M : #DIV/0! LHS
#16 TIE WIRE required: #DIV/0! Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


B2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 3.42 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 5.00 PCS
#16 TIE WIRE USED: 0.50 Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 2.32 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D 2 1
Top Bars 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 - 20.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 4.00 PCS
#16 TIE WIRE USED: 0.50 Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


G2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 2.82 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 2 20.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


D
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


W

L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 6.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 5.00 PCS
#16 TIE WIRE USED: 0.70 Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


b2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.46 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 1 20.00 mm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


D
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 6.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
G2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.74 M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D 2 2
Top Bars 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 7.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 7.00 PCS
#16 TIE WIRE USED: 0.80 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


G1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 4.59 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D 2 1
Top Bars 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 - 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 2.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 5.00 PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 6.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
G2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.81 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D 2 2
Top Bars 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS
WEB BARS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 9.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 8.00 PCS
#16 TIE WIRE USED: 0.90 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
G2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.99 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D 2 2
Top Bars 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

Colum
n
Width
BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK
Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 9.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 8.00 PCS
#16 TIE WIRE USED: 0.90 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
B1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 7.21 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 8.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 9.00 PCS
#16 TIE WIRE USED: 0.90 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
B1
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 5.81 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 1 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15
L

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 3.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 8.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 8.00 PCS
#16 TIE WIRE USED: 0.80 Kgs
BY: ENGR. RONALD JOHN R. CAJILLA
G2
BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 1.99 M


Enter Beam Width W (M) 0.20 M
L(beam to beam) Enter Beam Depth D (M) 0.40 M
Enter Column Width Cw(M) 0.50 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 2 20.00 mm
Web Bars
Web Bars - - - mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 20.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


0.15
L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 1.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 1.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 1.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 20mm bars used as main bars 4.00 PCS
Number of 0mm bars used as web bars - PCS
Number of 10mm bars used as stirrups 4.00 PCS
#16 TIE WIRE USED: 0.60 Kgs
BEAM REINFORCEMENT (TWO BAYS) CONTINUOUS BEAM
Enter Beam Length 1 L1 (M) 5.00 M
Enter Beam Length 2 L2 (M) 5.00 M
Enter Beam Width W (M) 0.20 M
Enter Beam Depth D (M) 0.30 M
L1 L2
Enter Column Width Max Cw(M) 0.30 M
# of Bars # of Non-
Top Bars Continuou Continuou Size of Bars Units
s s Bars
D Top Bars 2 1 12.00 mm
Web Bars
Web Bars - - 10.00 mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 2 1 12.00 mm
W
Enter Stirrup Bars Diameter required: 10.00 mm
Enter Stirrup Spacing: 0.20 M
L = Span1 L = Span2
L/4 L/4

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


L/4 L/4

0.15 L
0.15 L

Colum
n
Width TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 4.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars used as Continuous Bars 4.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars 2.00 PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 12mm bars required as main bars 12.00 PCS
Number of 10mm bars required as web bars - PCS
Number of 10mm bars required as stirrups 2.00 PCS
#16 TIE WIRE USED: 2.20 Kgs
ONE WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 3.764 0.474
12.500 3.062 0.316
15.000 2.584 0.228
17.500 2.232 0.168
20.000 1.980 0.132
22.200 1.786 0.110
25.000 1.627 0.089

T Enter Length b1 (M) 4.70 M


W b2 (M) 4.41 M
Enter height h (M) 0.80
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 1.980


# of Ties #16 Constant factor c 0.132
L # OF STEEL BARS required PCS @ 6M 8.00 PCS
# OF #16 TIE WIRE required KGS 1.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

T Enter Length b1 (M) 4.42 M


W b2 (M) 3.36 M
Enter height h (M) 2.89 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 27.00 PCS
# OF #16 TIE WIRE required KGS 2.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

T Enter Length b1 (M) 3.36 M


W b2 (M) 2.29 M
Enter height h (M) 2.92 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 20.00 PCS
# OF #16 TIE WIRE required KGS 2.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

T Enter Length b1 (M) 4.46 M


W b2 (M) 5.34 M
Enter height h (M) 2.40 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 28.00 PCS
# OF #16 TIE WIRE required KGS 3.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

TWO WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


17.500 2.647 0.247
20.000 2.360 0.174
22.200 2.168 0.168
25.000 1.977 0.142

T Enter Length b1 (M) 2.64 M


W b2 (M) 1.52 M
Enter height h (M) 3.08 M
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 16.00 PCS
# OF #16 TIE WIRE required KGS 2.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA
stair slab

TWO WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB

BAR SPACING IN CM. NUMBER OF STEEL BARS PER SQUARE METER TIES (KGS)
10.000 4.369 0.592
12.500 3.603 0.416
15.000 3.221 0.350
17.500 2.647 0.247
20.000 2.360 0.174

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


22.200 2.168 0.168
25.000 1.977 0.142

W T
1.87
Enter Bar Spacing cm 20.00 CM

# of Steel Bar Constant factor c 2.360


# of Ties #16 Constant factor c 0.174
L # OF STEEL BARS required PCS @ 6M 5.00 PCS
# OF #16 TIE WIRE required KGS 1.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA

REINFORCED GROUND SLAB (BARS SPACING MORE THAN 25CM)

T Enter Length L (M) 11.87 M


W Enter Width W (M) 7.87 M
Enter Bar Spacing along W cm 15.00 CM
Enter Bar Spacing along L cm 15.00 CM

# OF STEEL BARS USED PARALLEL TO L PCS @ 6M 116.00 PCS


L # OF STEEL BARS USED PARALLEL TO W PCS @ 6M 115.00 PCS
# OF #16 TIE WIRE required KGS 76.00 KGS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


1st 26.71704 d1 6.405
2nd 46.66155 d2 4.41
3rd 40.90341 d3 2.1
4th 40.90341 d4 2.1
5th 40.90341 d5 2.1
RD 31.36519 d6 2.1
d7 1.26
d8 2.1
w1 54.94 13.4 4.1
w2 0.55 0.5 1.1
w3 44.486 15.08 2.95
elevator 4.2

1st floor 3
54.51
2nd floor 3.35
49.85
3rd & 4th 3.35
49.85
roof deck 3.35
21.99
0.5
40.0324
roof plan 1
26.75

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
CARPENTRY WORKS
Determining the total board foot of a lumber.
Enter Number of pieces # 399.00 PCS
Enter lumber Dimension W1(IN) 2.00 inches
W2(IN) 2.00 inches
L L(FT) 12.00 feet (ft)

TOTAL # OF LUMBER IN BD.FT Bd.ft. 1,596.00 BD.FT

W2

W1

Determining the total board foot of a round log


FORMULA: (D - 4)² x L
16

Enter Number of pieces # PCS


Enter lumber Dimension D1(IN) inches
L(FT) feet (ft)

TOTAL # OF LUMBER IN BD.FT Bd.ft. - BD.FT

Determining the total lengths or pcs of a certain lumber from Bd.ft.

Enter total Bd.ft : Bd.ft. 970.00


L Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
2 2 12

TOTAL # OF LUMBER IN PIECES/LENGTHS PCS 242.50 PCS


W2

W1
BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


NUMBER OF BOARD FOOT OF STUDS & NAILING JOIST PER SQUARE METER
SPACING IN CENTIMETER (CENTER TO CENTER)
Lumber size
in inches 30 x 30 30 x 60 40 x 40 40 x 60 60 x 60
1x2 4.103 3.147 3.189 2.686 2.268
2x2 8.198 6.293 6.379 5.373 4.594
2x3 12.284 9.440 9.569 8.060 6.898
2x4 16.414 12.592 12.758 10.746 9.195

L
Enter Length of Wall/Ceilling/Flooring L (M) 970.00 M
Enter Height of Wall/Ceilling/Flooring H (M) 3.40 M
Enter Constant Factor C 6.898
# OF BD.FT OF STUDS & NAILING JOIST USED: BD.FT 22,749.60 BD.FT.

Enter total Bd.ft : Bd.ft.


Enter desired lumber dimension : W1 (in) W2 (in) L (ft)

TOTAL # OF LUMBER IN PIECES/LENGTHS PCS #DIV/0! PCS

USING 1/4" ORDINARY PLYWOOD or 4' x 8' HARDIFLEX BOARD


TOTAL # OF 4'X 8' ORDINARY PLYWOOD USED (ONE SIDE) SHTS 1146 Sheets
TOTAL # OF 4'X 8' ORDINARY PLYWOOD USED (TWO SIDES) SHTS 2291 Sheets

# OF 1" CWNails Used for Boards (ONE SIDE) KGS 63.1 KGS
# OF 1" CWNails Used for Boards (TWO SIDES) KGS 126.1 KGS
# OF 2 1/2" CWNails Used for Joining the Studs together KGS 164.9 KGS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
ROOFING WORKS

Side Lapping 2 1/2 1 1/2


Effective Width 0.60 0.70
Roof Sheet Length 1
End Lapping 25cm - 30 cm

Roof Sheet Length 2 End


lapping
H

Ls
Span

Projection
(Bulada)

Pitch

12

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


DETERMINING THE DESIRABLE NUMBER OF SHEETS IF USING MORE THAN ONE SHEET
Rafter L1 11.35077 Enter Span (Ls) M 11.00 M
Angle 0.260189 Enter Height (H) M 2.80 M
H2 0.25 nter Projection Width (Bulada) M 1.00 M
Rafter L2 1.03187
# of pulins 19.00 Total Length of Rafter M 12.38 M
USING ONLY TWO SHEETS
Roofing Length 12.46 Total Roofing Net Length M 12.46 M
1 FT 10 FT
3.00 Enter Roof Sheet Length 1
2.70 Enter Roof Sheet Length 2 FT 10 FT
2 Overlap (6.46) M (21.19) FT
Adjust Sheet Length!

USING THREE SHEETS


Roofing Length1 12.46 Total Roofing Net Length M 12.46 M
3.00 Enter Roof Sheet Length 1 FT 10 FT
2 2.70 Enter Roof Sheet Length 2 FT 10 FT
3 2.70 Enter Roof Sheet Length 3 FT 10 FT
Overlap (1.73) M (5.67) FT
Adjust Sheet Length!

DETERMINING THE NUMBER OF ROOF SHEETS

Side Lapping 2 1/2 1 1/2


Effective Width 0.60 0.70
Enter Roofing total with M 24.00 M
Total Roof Width Enter Effective Width M 0.70 M
USING ONLY TWO SHEETS
Number of the 1st Roof sheet used @ 10 feet long at one side only 35 Sheets
Number of the 2nd Roof sheet used @ 10 feet long at one side only 35 Sheets
Number of Umbrella Nails/Tekscrews 13 KGS

Note: Must multiply by two if the other side of the roof is similar

USING THREE SHEETS


Number of the 1st Roof sheet used @ 10 feet long at one side only 35 Sheets
Number of the 2nd Roof sheet used @ 10 feet long at one side only 35 Sheets
Number of the 3rd Roof sheet used @ 10 feet long at one side only 35 Sheets
Number of Umbrella Nails/Tekscrews 20 KGS

Note: Must multiply by two if the other side of the roof is similar

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


R
o
o
f

W
i
d
t Roof Width
h

ROOF ACCESSORIES

Enter Total Covered Length 40.00 M


Enter Effective Length 2.20 M
Number of Roof Accessories Used 19 PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
ROOFING WORKS

Side Lapping 2 1/2 1 1/2


Effective Width 0.60 0.70
Roof Sheet Length 1
End Lapping 25cm - 30 cm

Roof Sheet Length 2 End


lapping
H

Ls
Span

Projection
(Bulada)

Pitch

12

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


DETERMINING THE DESIRABLE NUMBER OF SHEETS IF USING MORE THAN ONE SHEET
Rafter L1 3.988804 Enter Span (Ls) M 3.85 M
Angle 0.277765 Enter Height (H) M 1.04 M
H2 0.24 Enter Projection Width (Bulada) M 0.90 M
Rafter L2 0.932424
# of pulins 9.00 Total Length of Rafter M 4.92 M
USING ONLY TWO SHEETS
Roofing Length 5.00 Total Roofing Net Length M 5.00 M
1 FT 8 FT
2.40 Enter Roof Sheet Length 1
2.10 Enter Roof Sheet Length 2 FT 8 FT
2 Overlap (0.20) M (0.64) FT
Adjust Sheet Length!

USING THREE SHEETS


Roofing Length1 5.00 Total Roofing Net Length M 5.00 M
2.40 Enter Roof Sheet Length 1 FT 8 FT
2 2.10 Enter Roof Sheet Length 2 FT 8 FT
3 2.10 Enter Roof Sheet Length 3 FT 8 FT
Overlap 1.10 M 3.62 FT
OK Roof Sheet combination
But not economical, cost you more money!
End Lapping must not be more than 2 ft
DETERMINING THE NUMBER OF ROOF SHEETS

Side Lapping 2 1/2 1 1/2


Effective Width 0.60 0.70
Enter Roofing total with M 8.00 M
Total Roof Width Enter Effective Width M 0.70 M
USING ONLY TWO SHEETS
Number of the 1st Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of the 2nd Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of Umbrella Nails/Tekscrews 4 KGS

Note: Must multiply by two if the other side of the roof is similar

USING THREE SHEETS


Number of the 1st Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of the 2nd Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of the 3rd Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of Umbrella Nails/Tekscrews 6 KGS
Not recommended, cost you more money!
Note: Must multiply by two if the other side of the roof is similar

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


R
o
o
f

W
i
d
t Roof Width
h

ROOF ACCESSORIES

Enter Total Covered Length 10.75 M


Enter Effective Length 2.30 M
Number of Roof Accessories Used 5 PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
ROOFING WORKS

Side Lapping 2 1/2 1 1/2


Effective Width 0.60 0.70
Roof Sheet Length 1
End Lapping 25cm - 30 cm

Roof Sheet Length 2 End


lapping
H

Ls
Span

Projection
(Bulada)

Pitch

12

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


DETERMINING THE DESIRABLE NUMBER OF SHEETS IF USING MORE THAN ONE SHEET
Rafter L1 3.988804 Enter Span (Ls) M 3.85 M
Angle 0.277765 Enter Height (H) M 1.04 M
H2 0.24 Enter Projection Width (Bulada) M 0.90 M
Rafter L2 0.932424
# of pulins 9.00 Total Length of Rafter M 4.92 M
USING ONLY TWO SHEETS
Roofing Length 5.00 Total Roofing Net Length M 5.00 M
1 FT 8 FT
2.40 Enter Roof Sheet Length 1
2.10 Enter Roof Sheet Length 2 FT 8 FT
2 Overlap (0.20) M (0.64) FT
Adjust Sheet Length!

USING THREE SHEETS


Roofing Length1 5.00 Total Roofing Net Length M 5.00 M
2.40 Enter Roof Sheet Length 1 FT 8 FT
2 2.10 Enter Roof Sheet Length 2 FT 8 FT
3 2.10 Enter Roof Sheet Length 3 FT 8 FT
Overlap 1.10 M 3.62 FT
OK Roof Sheet combination
But not economical, cost you more money!
End Lapping must not be more than 2 ft
DETERMINING THE NUMBER OF ROOF SHEETS

Side Lapping 2 1/2 1 1/2


Effective Width 0.60 0.70
Enter Roofing total with M 8.00 M
Total Roof Width Enter Effective Width M 0.70 M
USING ONLY TWO SHEETS
Number of the 1st Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of the 2nd Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of Umbrella Nails/Tekscrews 4 KGS

Note: Must multiply by two if the other side of the roof is similar

USING THREE SHEETS


Number of the 1st Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of the 2nd Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of the 3rd Roof sheet used @ 8 feet long at one side only 12 Sheets
Number of Umbrella Nails/Tekscrews 6 KGS
Not recommended, cost you more money!
Note: Must multiply by two if the other side of the roof is similar

BY: ENGR. RONALD JOHN R. CAJILLA

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


R
o
o
f

W
i
d
t Roof Width
h

ROOF ACCESSORIES

Enter Total Covered Length 7.75 M


Enter Effective Length 2.30 M
Number of Roof Accessories Used 4 PCS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA

TILING WORKS
Enter Wall or Floor Area 265.80 SQ.M.
Enter Breakage Allowance (5 - 10%) 5.00 %

Tile Size # of PCS


Inches cm per Sq.m.
3x3 7.5 x 7.5 49,622.00
4x4 10 x 10 27,909.00
4 1/4 x 4 1/4 10.6 x 10.6 24,672.00
4x8 10 x 20 13,955.00
6x6 15 x 15 12,403.00
6x8 15 x 20 9,302.00
6 x 12 15 x 30 6,202.00
8x8 20 x 20 6,978.00
8 x 12 20 x 30 4,650.00
8 x 16 20 x 40 3,489.00
10 x 16 25 x 25 4,466.00
12 x 12 30 x 30 3,101.00
12 x 24 30 x 60 1,552.00
16 x 16 40 x 40 1,745.00
20 x 20 50 x 50 1,117.00
24 x 24 60 x 60 776.00

Cement Mortar 23.00 BAGS


White Cement 133.00 KGS
Adhesive 30.00 BAGS

t&b

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA

TILING WORKS
Enter Wall or Floor Area 675.40 SQ.M.
Enter Breakage Allowance (5 - 10%) 5.00 %

Tile Size # of PCS


Inches cm per Sq.m.
3x3 7.5 x 7.5 126,090.00
4x4 10 x 10 70,917.00
4 1/4 x 4 1/4 10.6 x 10.6 62,691.00
4x8 10 x 20 35,459.00
6x6 15 x 15 31,516.00
6x8 15 x 20 23,637.00
6 x 12 15 x 30 15,758.00
8x8 20 x 20 17,730.00
8 x 12 20 x 30 11,815.00
8 x 16 20 x 40 8,865.00
10 x 16 25 x 25 11,347.00
12 x 12 30 x 30 7,879.00
12 x 24 30 x 60 3,943.00
16 x 16 40 x 40 4,433.00
20 x 20 50 x 50 2,837.00
24 x 24 60 x 60 1,972.00

Cement Mortar 59.00 BAGS


White Cement 338.00 KGS
Adhesive 75.00 BAGS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA

TILING WORKS
Enter Wall or Floor Area 1,420.22 SQ.M.
Enter Breakage Allowance (5 - 10%) 5.00 %

Tile Size # of PCS


Inches cm per Sq.m.
3x3 7.5 x 7.5 265,141.00
4x4 10 x 10 149,123.00
4 1/4 x 4 1/4 10.6 x 10.6 131,825.00
4x8 10 x 20 74,562.00
6x6 15 x 15 66,271.00
6x8 15 x 20 49,703.00
6 x 12 15 x 30 33,136.00
8x8 20 x 20 37,281.00
8 x 12 20 x 30 24,844.00
8 x 16 20 x 40 18,641.00
10 x 16 25 x 25 23,860.00
12 x 12 30 x 30 16,568.00
12 x 24 30 x 60 8,292.00
16 x 16 40 x 40 9,321.00
20 x 20 50 x 50 5,965.00
24 x 24 60 x 60 4,146.00

Cement Mortar 123.00 BAGS


White Cement 711.00 KGS
Adhesive 157.00 BAGS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA

TILING WORKS
Enter Wall or Floor Area 1,812.80 SQ.M.
Enter Breakage Allowance (5 - 10%) 5.00 %

Tile Size # of PCS


Inches cm per Sq.m.
3x3 7.5 x 7.5 338,433.00
4x4 10 x 10 190,345.00
4 1/4 x 4 1/4 10.6 x 10.6 168,265.00
4x8 10 x 20 95,173.00
6x6 15 x 15 84,590.00
6x8 15 x 20 63,442.00
6 x 12 15 x 30 42,295.00
8x8 20 x 20 47,587.00
8 x 12 20 x 30 31,712.00
8 x 16 20 x 40 23,794.00
10 x 16 25 x 25 30,456.00
12 x 12 30 x 30 21,148.00
12 x 24 30 x 60 10,584.00
16 x 16 40 x 40 11,897.00
20 x 20 50 x 50 7,614.00
24 x 24 60 x 60 5,292.00

Cement Mortar 156.00 BAGS


White Cement 907.00 KGS
Adhesive 200.00 BAGS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
PAINTING WORKS
Unit Conversio1 Gallon = 4 Liters Enter Wall Area 15,703.80 SQ.M.
Coverage
Simplified Construction Estimate Enter Coverage 40.00 /Gal
Table 10-6 Kinds of Paint, Uses and Area Coverage Enter # of Coats 2.00 Coats
PRIMERS Number of Gallons 786.00 Gals
KIND OF PAINT USES THINING DRYING TIMECOVERAGE/Gal
1. Interior For interior 2 hrs, allow 25 to 30
Primer & wood Paint Thinner overnight b4 sq.m.
Sealer surfaces recoating

2. Exterior Forwood
exterior 6 hrs, allow 30 to 40
Paint Thinner overnight b4
Wood Primer sq.m.
surfaces recoating

Primer for
3. Red Oxide ferrous and Paint Thinner 35 to 40
3 Hours
Primer non-ferrous sq.m.
materials

Rust
preventive
4. Red Lead 30 to 40
primer for Paint Thinner 3 Hours
Primer sq.m.
ferrous
surfaces

For Steel, 6 hrs, allow


5. Epoxy Aluminum, Epoxy overnight b4 30 to 40
Primer Galvanized Reducer sq.m.
recoating
iron

WATER BASE MASONRY PAINT


KIND OF PAINT USES THINING DRYING TIMECOVERAGE/Gal

Exterior & 30 minutes


1. Acrylic Interior 1/2 lts/ 4 lts allow 30 to 40
6 hrs b4
Latex Paint masonry water sq.m.
recoat
surfaces

Exterior &
2. Acrylic 30 minutes
Interior 30 to 40
Semi-Gloss Water allow 6 hrs b4
masonry sq.m.
Latex recoat
surfaces

Exterior & 30 minutes


3. Acrylic Interior 30 to 40
Water allow 6 hrs b4
Gloss Latex masonry sq.m.
recoat
surfaces

For furniture,
cabinets,
doors, 1 Hour. Allow
4. Latex Hi- windows, 30 to 40
Usse as is 4 hrs before
Gloss Enamel tools, toys, sq.m.
recoating
wrought iron,
& primed
metals

5. Tinting Acrylic colors water


Colors

ROOF PAINT
KIND OF PAINT USES THINING DRYING TIMECOVERAGE/Gal

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


for G.I. Shts, 4 hrs. allow
1. All weather asbestos
overnight 40 to 50
acylic roof bricks water before sq.m.
shield concrete and recoating
stucco

G.I. roofs and 6 hrs. allow


other metal
2. Davies Paint Thinner overnight 30 to 40
such as
Roof paint before sq.m.
aluminum recoating
and steel

ENAMEL AND GLOSS PAINT


KIND OF PAINT USES THINING DRYING TIMECOVERAGE/Gal

1. Quick for exterior & 5 hrs. allow 8


interior wood Paint Thinner hrs. before 30 to 40
Drying and metal sq.m.
Enamel recoating
surface

6 hrs. allow
2. Interior Interior wood
and metal Paint Thinner overnight 25 to 30
semi-Gloss
before sq.m.
Enamel surfaces recoating

3 hrs. allow
for interior
3. Flat wall overnight 40 to 50
wall & Paint Thinner
Enamel before sq.m.
ceilings
recoating

for exterrior
wood and 6 hrs. allow
4. Exterior 30 to 35
properly Paint Thinner 48 hrs. before
Gloss paint sq.m.
primed metal recoating
surfaces

5. Tinting Oil Base


Colors tinting color
VARNISHING
KIND OF PAINT USES THINING DRYING TIMECOVERAGE/Gal

for floors,
1. Valspar or sidings 40 to 50
furnitures, Paint Thinner 24 hours
Spar Varnish sq.m.
deck of boats

for interior
new wood 10 minutes.
2. Hi-solid furnitures Lacquer Allow 30 40 to 50
sanding and fixtures, Thinner minutes sq.m.
sealer cabinet, before recoat
doors, etc.

for interior
new wood
3. Hi-solid Allow 30
furnitures, Lacquer 30 to 40
clear gloss minutes
door Thinner sq.m.
Lacquer before recoat
panelling and
trim.

for interior
new wood
4. Hi-solid Allow 30
furnitures, Lacquer 30 to 40
Semi-gloss minutes
cabinets, Thinner sq.m.
Lacquer before recoat
doors,
shelves, etc

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


for interior
wood
furniture,
5. Hi-solid Allow 30
cabinets, Lacquer 30 to 40
dead flat minutes
door jambs, Thinner sq.m.
Lacquer before recoat
trim
panelling,
etc.

for furnitures,
6. Water cabinets, Allow 30
Lacquer 30 to 40
white gloss doors, panel minutes
Thinner sq.m.
Lacquer and interior before recoat
walls

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK


BY: ENGR. RONALD JOHN R. CAJILLA
FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

Enter Column Height M 16.10


Column Dimension A M 0.40
Column Dimension B M 0.40
Co Enter Number of Columns Units 82.00
lu 1.80 354.24
m Note: One form per column - (Resusable form)
n 3,649.41 Bd.ft
He 4' Total # of Bd.ft of frame required:
igh OR Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
t 2. 2 3 55
4
M Total Number of Lumber: 133.00 PCS
Total Number of Plywood required: 123.00 Sheet(s)
Total Number of #2 1/2 CWNails: 28.40 KGS
Total Number of #1 Finishing Nails: 11.70 Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Enter Beam Length M 5.00


Beam Dimension D M 0.40
Beam Dimension B M 0.30
Enter Number of Beams Units 194.00
1.20 1,164.00
Total Beam Length
Total # of Bd.ft of frame required: 11,340.00 Bd.ft
W1 (in) W2 (in) L (ft)
2 3 17
D Total Number of Lumber: 1,335.00 PCS
Total Number of Plywood required: 405.00 Sheet(s)
Total Number of #2 1/2 CWNails: 93.20 KGS
Total Number of #1 Finishing Nails: 38.50 Kgs
B
BY: ENGR. RONALD JOHN R. CAJILLA

COLUMN BEAM
nter Column Height M 16.10 Enter Beam Length M 5.00
Enter # of Columns Units 82.00 Enter # of Beams Units 194.00
otal Column Height: 1,320.20 M. Ht. Total Beam Length: 970.00 M. Ht.

FLOORING
Enter Floor Area SQ.M. 2,755.35

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Lumber Column Beam
Flooring
Size Vertical Horizontal Brace Vertical Horizontal
2" x 2" 6,204.94 27,724.20 15,446.34 3,880.00 4,559.00 16,807.64
2" x 3" 9,241.40 41,810.73 23,103.50 5,820.00 6,790.00 25,073.69
2" x 4" 12,343.87 55,778.45 30,826.67 7,760.00 9,069.50 33,339.74

Enter total # of Bd.ft of Lumber required: 224.40 Bd.ft


W1 (in) W2 (in) L (ft)
2 4 8
Total Number of Lumber: 43.00 PCS
Total Number of #4 CWNails: 964.00 KGS
BY: ENGR. RONALD JOHN R. CAJILLA
SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts
BY: ENGR. RONALD JOHN R. CAJILLA
FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

Enter Column Height M


Column Dimension A M
Column Dimension B M
Co Enter Number of Columns Units
lu 0.20 -
m Note: One form per column - (Resusable form)
n - Bd.ft
He 4' Total # of Bd.ft of frame required:
igh OR Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
t 2.
4
M Total Number of Lumber: #DIV/0! PCS
Total Number of Plywood required: - Sheet(s)
Total Number of #2 1/2 CWNails: - KGS
Total Number of #1 Finishing Nails: - Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Enter Beam Length M 4.00


Beam Dimension D M 0.40
Beam Dimension B M 0.30
Enter Number of Beams Units 80.00
1.20 384.00
Total Beam Length
Total # of Bd.ft of frame required: 3,752.00 Bd.ft
W1 (in) W2 (in) L (ft)
2 3 14
D Total Number of Lumber: 536.00 PCS
Total Number of Plywood required: 134.00 Sheet(s)
Total Number of #2 1/2 CWNails: 30.80 KGS
Total Number of #1 Finishing Nails: 12.70 Kgs
B
BY: ENGR. RONALD JOHN R. CAJILLA

COLUMN BEAM
Enter Column Height M - Enter Beam Length M 4.00
Enter # of Columns Units Enter # of Beams Units 80.00
Total Column Height: - M. Ht. Total Beam Length: 320.00 M. Ht.

FLOORING
Enter Floor Area SQ.M. 2,755.35

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Lumber Column Beam
Flooring
Size Vertical Horizontal Brace Vertical Horizontal
2" x 2" - - - 1,280.00 1,504.00 16,807.64
2" x 3" - - - 1,920.00 2,240.00 25,073.69
2" x 4" - - - 2,560.00 2,992.00 33,339.74

Enter total # of Bd.ft of Lumber required: 224.40 Bd.ft


W1 (in) W2 (in) L (ft)
2 4 14
Total Number of Lumber: 25.00 PCS
Total Number of #4 CWNails: - KGS

BY: ENGR. RONALD JOHN R. CAJILLA


SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts
BY: ENGR. RONALD JOHN R. CAJILLA
FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

Enter Column Height M


Column Dimension A M
Column Dimension B M
Co Enter Number of Columns Units
lu 0.20 -
m Note: One form per column - (Resusable form)
n - Bd.ft
He 4' Total # of Bd.ft of frame required:
igh OR Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
t 2.
4
M Total Number of Lumber: #DIV/0! PCS
Total Number of Plywood required: - Sheet(s)
Total Number of #2 1/2 CWNails: - KGS
Total Number of #1 Finishing Nails: - Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Enter Beam Length M 3.00


Beam Dimension D M 0.40
Beam Dimension B M 0.30
Enter Number of Beams Units 87.00
1.20 313.20
Total Beam Length
Total # of Bd.ft of frame required: 3,052.00 Bd.ft
W1 (in) W2 (in) L (ft)
2 3 10
D Total Number of Lumber: 611.00 PCS
Total Number of Plywood required: 109.00 Sheet(s)
Total Number of #2 1/2 CWNails: 25.10 KGS
Total Number of #1 Finishing Nails: 10.40 Kgs
B
BY: ENGR. RONALD JOHN R. CAJILLA

COLUMN BEAM
Enter Column Height M - Enter Beam Length M 3.00
Enter # of Columns Units Enter # of Beams Units 87.00
Total Column Height: - M. Ht. Total Beam Length: 261.00 M. Ht.

FLOORING
Enter Floor Area SQ.M. 2,755.35

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Lumber Column Beam
Flooring
Size Vertical Horizontal Brace Vertical Horizontal
2" x 2" - - - 1,044.00 1,226.70 16,807.64
2" x 3" - - - 1,566.00 1,827.00 25,073.69
2" x 4" - - - 2,088.00 2,440.35 33,339.74

Enter total # of Bd.ft of Lumber required: 224.40 Bd.ft


W1 (in) W2 (in) L (ft)
2 4 10
Total Number of Lumber: 34.00 PCS
Total Number of #4 CWNails: - KGS
BY: ENGR. RONALD JOHN R. CAJILLA
SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts
BY: ENGR. RONALD JOHN R. CAJILLA
FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

Enter Column Height M


Column Dimension A M
Column Dimension B M
Co Enter Number of Columns Units
lu 0.20 -
m Note: One form per column - (Resusable form)
n - Bd.ft
He 4' Total # of Bd.ft of frame required:
igh OR Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
t 2.
4
M Total Number of Lumber: #DIV/0! PCS
Total Number of Plywood required: - Sheet(s)
Total Number of #2 1/2 CWNails: - KGS
Total Number of #1 Finishing Nails: - Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Enter Beam Length M 2.50


Beam Dimension D M 0.40
Beam Dimension B M 0.30
Enter Number of Beams Units 54.00
1.20 162.00
Total Beam Length
Total # of Bd.ft of frame required: 1,596.00 Bd.ft
W1 (in) W2 (in) L (ft)
2 3 9
D Total Number of Lumber: 355.00 PCS
Total Number of Plywood required: 57.00 Sheet(s)
Total Number of #2 1/2 CWNails: 13.00 KGS
Total Number of #1 Finishing Nails: 5.40 Kgs
B
BY: ENGR. RONALD JOHN R. CAJILLA

COLUMN BEAM
Enter Column Height M - Enter Beam Length M 2.50
Enter # of Columns Units Enter # of Beams Units 54.00
Total Column Height: - M. Ht. Total Beam Length: 135.00 M. Ht.

FLOORING
Enter Floor Area SQ.M. 2,755.35

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Lumber Column Beam
Flooring
Size Vertical Horizontal Brace Vertical Horizontal
2" x 2" - - - 540.00 634.50 16,807.64
2" x 3" - - - 810.00 945.00 25,073.69
2" x 4" - - - 1,080.00 1,262.25 33,339.74

Enter total # of Bd.ft of Lumber required: 224.40 Bd.ft


W1 (in) W2 (in) L (ft)
2 4 9
Total Number of Lumber: 38.00 PCS
Total Number of #4 CWNails: - KGS

BY: ENGR. RONALD JOHN R. CAJILLA


SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts
BY: ENGR. RONALD JOHN R. CAJILLA
FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

Enter Column Height M


Column Dimension A M
Column Dimension B M
Co Enter Number of Columns Units
lu 0.20 -
m Note: One form per column - (Resusable form)
n - Bd.ft
He 4' Total # of Bd.ft of frame required:
igh OR Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
t 2.
4
M Total Number of Lumber: #DIV/0! PCS
Total Number of Plywood required: - Sheet(s)
Total Number of #2 1/2 CWNails: - KGS
Total Number of #1 Finishing Nails: - Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Enter Beam Length M 4.00


Beam Dimension D M 0.40
Beam Dimension B M 0.20
Enter Number of Beams Units 12.00
1.10 52.80
Total Beam Length
Total # of Bd.ft of frame required: 532.00 Bd.ft
W1 (in) W2 (in) L (ft)
2 3 14
D Total Number of Lumber: 76.00 PCS
Total Number of Plywood required: 19.00 Sheet(s)
Total Number of #2 1/2 CWNails: 4.30 KGS
Total Number of #1 Finishing Nails: 1.80 Kgs
B
BY: ENGR. RONALD JOHN R. CAJILLA

COLUMN BEAM
Enter Column Height M - Enter Beam Length M 4.00
Enter # of Columns Units Enter # of Beams Units 12.00
Total Column Height: - M. Ht. Total Beam Length: 48.00 M. Ht.

FLOORING
Enter Floor Area SQ.M. 2,755.35

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Lumber Column Beam
Flooring
Size Vertical Horizontal Brace Vertical Horizontal
2" x 2" - - - 192.00 225.60 16,807.64
2" x 3" - - - 288.00 336.00 25,073.69
2" x 4" - - - 384.00 448.80 33,339.74

Enter total # of Bd.ft of Lumber required: 532.00 Bd.ft


W1 (in) W2 (in) L (ft)
2 4 14
Total Number of Lumber: 57.00 PCS
Total Number of #4 CWNails: - KGS

BY: ENGR. RONALD JOHN R. CAJILLA


SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts
BY: ENGR. RONALD JOHN R. CAJILLA
FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

Enter Column Height M


Column Dimension A M
Column Dimension B M
Co Enter Number of Columns Units
lu 0.20 -
m Note: One form per column - (Resusable form)
n - Bd.ft
He 4' Total # of Bd.ft of frame required:
igh OR Enter desired lumber dimension : W1 (in) W2 (in) L (ft)
t 2.
4
M Total Number of Lumber: #DIV/0! PCS
Total Number of Plywood required: - Sheet(s)
Total Number of #2 1/2 CWNails: - KGS
Total Number of #1 Finishing Nails: - Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Enter Beam Length M 5.00


Beam Dimension D M 0.30
Beam Dimension B M 0.20
Enter Number of Beams Units 18.00
0.90 81.00
Total Beam Length
Total # of Bd.ft of frame required: 812.00 Bd.ft
W1 (in) W2 (in) L (ft)
2 3 17
D Total Number of Lumber: 96.00 PCS
Total Number of Plywood required: 29.00 Sheet(s)
Total Number of #2 1/2 CWNails: 6.50 KGS
Total Number of #1 Finishing Nails: 2.70 Kgs
B
BY: ENGR. RONALD JOHN R. CAJILLA

COLUMN BEAM
Enter Column Height M - Enter Beam Length M 5.00
Enter # of Columns Units Enter # of Beams Units 18.00
Total Column Height: - M. Ht. Total Beam Length: 90.00 M. Ht.

FLOORING
Enter Floor Area SQ.M. 2,755.35

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Lumber Column Beam
Flooring
Size Vertical Horizontal Brace Vertical Horizontal
2" x 2" - - - 360.00 423.00 16,807.64
2" x 3" - - - 540.00 630.00 25,073.69
2" x 4" - - - 720.00 841.50 33,339.74

Enter total # of Bd.ft of Lumber required: 224.40 Bd.ft


W1 (in) W2 (in) L (ft)
2 4 17
Total Number of Lumber: 20.00 PCS
Total Number of #4 CWNails: - KGS

BY: ENGR. RONALD JOHN R. CAJILLA


SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts

You might also like