PUMP-UP TEST(ACFM) AND VOLUMETRIC EFFICIENCY(SCFM)

Compressor P/N: 12345678901 Compressor S/N: 12345678901


Configuration Control: 123 Contract: 1234567890123456789012345
Created By: 1234567890123456789012345

Formula:

Inputs:
V = Reservoir Volume = 7752 Cubic Inch
P2 = Final tank Pressure = 152 PSIG
P1 = Initial tank Pressure = 0 PSIG
Pact = Absolute Pressure at the Actual level = 14.7 PSIA
Pstd = Standard absolute air pressure = 14.7 PSIA
Tstd = Standard Temperature = 60 F
Tact = Actual ambient air temperature = 80 F
Psat = Saturation pressure at the actual temperature = 0.5069 PSIA
= Actual relative humidity = 50 %
t = Time = 0 minuntes 100
seconds

Output:
ACFM = Actual CFM (Flow) = 27.8322 cu.ft./min
= 788.1201 liter/min
SCFM = Standard CFM (Flow) = 20.5142 cu.ft./min
= 580.8988 liter/min