Professional Documents
Culture Documents
Date: 3/17/2009
(*) - ECM I/O (Current values here included in ECM Battery Power calculation)
General
Minimum Wire size……………………………………………………………….18 AWG
Indicator Lamps/LEDs
Minimum Luminous Intensity………….….. ~2 Candle Light/Visible in Bright Sun Light
Maximum Continuous Current Draw per Lamp…......................................................0.5 A
Minimum Current Draw for Valid Load Detection…………………………….….0.002 A
Maximum Leakage Current in Off Condition @ 12 V………………………….0.00002 A
Sensors and Switches
Nominal setting, Brake Pressure Switch.......................................................................4 PSI
Maximum Current Draw @ Key Switch Input………………………………………....5 A
Minimum Key Switch ON Voltage @ ECM…………………………………………...6 V
Maximum Power Interruption in Key switch Circuit to Remain ON…….…0.250 seconds
Maximum Voltage from Sensor Supply (pin G of 23 pin OEM connector)…….5V +/-5%
Maximum Current from Accelerator Supply (pin G of 23 pin OEM connector) ....250 mA
Maximum Current through ECM Accelerator Return..............................................250 mA
Output Drivers
Maximum Current from Each PWM/ On-Off Driver……………………..……………3 A
Maximum Leakage Current from Each PWM/On-Off Driver…………………..…0.002 A
Maximum Current through ECM General Return………………….…………………..3 A
Change Log:
3/17/09 – Corrected ECM battery power min wire size from 16 AWG to 12 AWG