Room 1 / Summary
Height of Room: 3.800 m, Mounting Height: 3.800 m, Maintenance factor: Values in Lux, Scale 1:411
0.80
Workplane:
Height: 2.800 m
Grid: 128 x 128 Points
Boundary Zone: 0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.982, Ceiling / Working Plane: 0.874.
Luminaire Parts List
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
1 28 PHILIPS TCW060 2xTL-D36W HF (1.000) 4095 6500 72.0
Total: 114660 Total: 182000 2016.0
Specific connected load: 2.25 W/m² = 0.59 W/m²/100 lx (Ground area: 896.00 m²)
Operator
Telephone
Fax
e-Mail
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 85 293 379 / /
Floor 68 297 365 90 105
Ceiling 11 319 331 90 95
Wall 1 36 309 345 90 99
Wall 2 52 309 361 90 103
Wall 3 36 306 342 90 98
Wall 4 52 309 361 90 103
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.982, Ceiling / Working Plane: 0.874.
Specific connected load: 2.25 W/m² = 0.59 W/m²/100 lx (Ground area: 896.00 m²)