Professional Documents
Culture Documents
26.09.2014
Operator
Telephone
Fax
e-Mail
Luminous emittance 1:
Page 1
Mona_interior
26.09.2014
Operator
Telephone
Fax
e-Mail
Sala_1 / Summary
Height of Room: 3.200 m, Mounting Height: 3.280 m, Light loss factor: Values in Lux, Scale 1:80
0.80
Workplane:
Height: 0.750 m
Grid: 32 x 32 Points
Boundary Zone: 0.500 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.222, Ceiling / Working Plane: 0.135.
Proportion of points with less than 400 lx (for IEQ-7): 7.03%.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
PHILIPS TBS162 4xTL5-14W HF C6-60
1 11 3600 5000 63.0
(1.000)
Total: 39600 Total: 55000 693.0
Specific connected load: 14.34 W/m² = 2.20 W/m²/100 lx (Ground area: 48.32 m²)
Page 2
Mona_interior
26.09.2014
Operator
Telephone
Fax
e-Mail
Page 3
Mona_interior
26.09.2014
Operator
Telephone
Fax
e-Mail
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²]
direct indirect total
Workplane 587 65 653 / /
Floor 451 77 527 20 34
Ceiling 0.00 88 88 70 20
Wall 1 126 83 209 50 33
Wall 2 89 75 165 50 26
Wall 3 82 76 158 50 25
Wall 4 42 75 116 50 19
Wall 5 101 74 176 50 28
Wall 6 84 79 163 50 26
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.222, Ceiling / Working Plane: 0.135.
Proportion of points with less than 400 lx (for IEQ-7): 7.03%.
Specific connected load: 14.34 W/m² = 2.20 W/m²/100 lx (Ground area: 48.32 m²)
Page 4