Professional Documents
Culture Documents
An Example of
Design and Structural Analysis
of Buried Flexible Steel Pipeline
Appropriated to Steep and Inaccessible
Mountainous Terrains
Beograd, 2010
Authors of Design:
Structural and Geotechnical Engineering: Zika Smiljkovic
Assisted by:
Structural geology and Soils characterization: Aleksanadar Balatov
__________________________________________________________________
Preface:
The Consultant was assigned the commission by the Water Board of Cetinje City of Republic Montenegro to
design a water pipeline aiming to improve the domestic water supply of the City. The pipeline route ex‐
panded to circa 1.0 km in total length, crossing the mountainous terrains of slopes grading from 5% to 50%
and of rather difficult accessibility. The diameter of the pipe was evaluated to be of 400 mm. The opera‐
tional conditions were expected to induce the internal water pressures of 40 bar (test phase), and 39.2 bar
(incidental over pressures due to hydraulic surge). The latter, occurring whilst accidental shoot‐up of con‐
trol valve at the existing Pumping Station which was constructed at the lowest point of the pipeline. An
appraisal was made on steel made pipes, to best suiting the encountered topo and geological conditions.
The Pipeline had to be placed over the existing one, which was to be kept under the operational condi‐
tions all the time of construction of new pipeline. Hence, the pipeline route was preconditioned to design
analyses. The site reconnaissance predicted the massive to stratified limestone then clayey deposits inter‐
calated with granular rocky fragments and the alluvial deposits, underlying the pipeline.
As a structural system, the pipeline scheme had to sustain:
• Internal water pressures,
• Gravity loads pronounced along the steep stretches of pipeline causing the pipeline to
slide, both under constructional and operational conditions,
• Deflection forces arising out from streamflow inertial pressures imparted to pipe bends,
and
• Inertial forces occurring whilst earthquake conditions.
Under the circumstances, the streamflow carrying system was devised to be compounded of:
• Steel pipe exercising the role of tubular girder along the pipeline route,
• Anchor blocks receiving the outward and gravity‐off resulting pressures at the pipeline
bends, and
• Intermediate supporting blocks suspending the sliding tendency of pipeline along the
steep stretches.
Although the scale wise, the subject pipeline is considerably inferior to that of headrace and mani‐
fold pipes for HP Stations, the method of analysis applied herein closely correspond to the method
distinctive for large diameter and highly pressurized waterways intended for hydropower projects.
Referenced Literature:
ASCE Manuals and Reports on Engineering Practice No. 119. Burred Flexible Pipe, Design and Structural
Analysis. By the Task Committee on Buried Flexible (Steel) Pipe Load Stability Criteria & de-
sign of the Pipeline Division of the American Society of Civil Engineers. Edited by: William R.
Whidden, P.E. April 1982.
Steel Water Pipe. Guide for Design and Installation, 2004. Manual of Water Supply Practices. American Water
Works Association.
Sadržaj Projekta
I Tehnički Izveštaj 3
II Proračun konstrukcije 6
cevovoda
III Predmer i Predračun Radova 32
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 3 of 34
cevovod
I Tehnički Izveštaj
A. Inženjerskogeološki aspekti projekta konstrukcije čeličnog cevovoda
Na osnovu rekognosciranja koridora trase cevovoda od Podgorskog vrela do rezervoara Višnjica izvršenog u
2009. godini, postojeće dokumentacije i literaturnih podataka, procenjeno je da su duž trase cevovoda
generalno zastupljene četiri sredine:
1. sredina: Krečnjaci anizijskog kata (T21)
Bankoviti do masivni, ređe slojeviti, kompaktni, detritični, organogeno –detritični i brečasti krečnjaci, beli
do sivi.
Sprudna facija bankovitih do masivnih, podređeno slojevitih krečnjaka i dolomita. Boje su bele, sive do žute.
Pretežno su ispucali i karstifikovani.
2. sredina: Diploporski krečnjaci i dolomiti (T21,2)
Bankoviti do masivni, podređeno slojeviti, krečnjaci i dolomiti, beli, sivi do rumenkasti.
3. sredina: Crvenica (ts) – crvenica sa odlomcima krečnjaka do 20%, veličine fragmenata od 0.5‐3 cm.
4. sredina: Aluvijalni nanos reke Graboštice (al) – prognozirane debljine 2‐2,5 m, sastavljen od
srednjezrnog do krupnozrnog šljunka sa dosta krupnijih odlomaka veličine glokova (GU).
Prognozne vrednosti paramatara sredina su date u tabeli br. 1. Vrednosti parametara deformabilnosti i
smicanja date su na osnovu prognoze da su u površinskoj zoni brzine uzdužnih elastičnih talasa u intervalu
od Vp=1500‐2000 m/s za 1. sredinu i Vp=1000‐1500 m/s za 2. sredinu.
Tabela br. 1: Fizičkomehanička svojstva stena i stenske mase duž trase cevovoda
Prosečna otpornost na
Prosečna Prosečna Prosečna elastična svojstva
smicanje
zapreminska monoaksijalna
Sredine Modula Ugao
težina čvrstoća na Poisson‐ov Kohezija
deformacije ED unutrašnjeg
γ (kN/m3) pritisak (MPa) koeficijent μ c (MPa)
(MPa) trenja ϕ (o)
1. Sredina 27,0 96,0 335,0 0,33 0,715 64
2. Sredina 26,5 70,0 80,0 0,35 0,335 63
3. Sredina 20,5 N/A 10,0 0,40 0,036 26
4. Sredina 19,0 N/A 40,0 0,37 0,0 35
U pogledu dozvoljenog opterećenja sredine 1. i 2. su pogodne za sva opterećenja od objekata, jer
su im svojstva povoljna.
Na osnovu literaturnih podataka za 3. sredinu prognozira se dozvoljeno opterećenje od qa=75‐100
kN/m2, a za 4. sredinu qa=600‐800 kN/m2.
B. Konstruktivno geotehnički aspekti projekta čeličnog cevovoda
Vizuelna observacija terena u zoni cevovoda koju je Projektant obavio u 2009. godini uzeta je kao
fundamentalna osnova za glavni projekat nosećeg sistema čeličnog cevovoda.
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 4 of 34
cevovod
Da bi se postavke projekta noseće konstrukcije verifikovale, neophodno je da se u fazi pripremnog
perioda građenja izvrše sledeće dodatne aktivnosti:
(i) Da se izvrši rasčišćavanje terena duž trase postojećeg cevovoda do nivoa koji će obezbediti
verifikaciju trase i podužnog profila cevovoda kao i snimanje poprečnih profila cevovoda.
(ii) Da se izvrši snimanje trase i podužnog profila cevovoda za potrebe građenja. Da se izvrši
snimanje poprečnih profila cevovoda na mestima ankernih blokova ABH25, ABV26/1, ABH30 i
ABV32. Da se izvrši snimanje poprečnih profila na svakih cca 10m duž trase cevovoda sa
tipovima fundiranja I i II.
(iii) Da se izvrši geološko kartiranje stene u zoni blokova ABH25, ABV26/1, ABH30 i ABV32, i da se u
slučaju jako oštećene stene na ovim lokacijama izradi potreban broj istražnih jama.
Zavisno od rezultata pregleda trase iz stavke (i) izvršiće se prilagođenje snimanja i istraživanja iz paragrafa
(ii) i (iii). Zavisno od dobijenih rezultata istraživanja i snimanja, možda će biti potrebno prilagoditi projektna
rešenja čeličnog cevovoda data u ovom elaboratu.
Noseći sistem cevovoda je projektovan tako da isti čine sam cevni nosač kao i ankerni blokovi na
poligonim tačkama cevovoda. Noseći sistem cevovoda je izložen uticajima sledećih opterećenja:
• Dejstvu podužne komponente gravitacionog opterećenja, na kosim deonicama cevovoda. Za
statičke uslove, cevovod biva nestabilan na klizanje za sve nagibe nivelete veće od 17 stepeni. Za
seizmičke uslove, cevovod postaje nestabilan za nagibe veće od 6 stepeni.
• Dejstvu vertikalnih i horizontalnih konveksnih skretnih sila usled toka vode. Za proračun skretnih
sila uzeti su pritisci u cevovdu koji se razvijaju pri ispitivanju cevovoda na vododrživost.
• Dejstvu inercijalnih sila od zemljotresa. U ovu svrhu region Cetinja je mikroseizmiran sa 0.2g vršnog
ubrzanja.
Stabilnost cevovoda u radnom stanju tj. pri dejstvu hidro‐pritisaka i sopstvene težine, se obezbeđuje u
vertikalnom, podužnom i horizontalno‐transverzalnom pravcu. Stabilnost cevovoda u vertikalnom
pravcu(izdizanje usled konveksnih skretnih sila) i podužnom pravcu(klizanje usled gravitacionih sila i
zemljotresa), se dominantno obezbeđuje vertikalnim ankernim blokovima, na crtežima obeleženim
oznakom ABVi . Na deonicama II i III fundiranja cevovoda, vertikalni ankerni blokovi u sadejstvu sa
potpornim blokovima(PBi), obezbeđuju i poprečnu stabilnost cevovoda u odnosu na kosine koje od
cevovodnog temelja padaju prema brdskim depresijama i potocima. Sa vertikalnim ankernim blokovima, u
zidovima cevovoda se odvija kontrolisano membransko naponsko stanje usled unutrašnjeg pritiska, čime se
sprečavaju naponski pikovi na krivinama, zamor materijala i naponska korozija pri pulzacionim pritiscima u
cevovodu.
Amortizovanje horozontalnih‐konveksnih skretnih sila na poligonim tačkama trase cevovoda, a time i
prostornog stanja napona u tim tačkama i preopterećenje cevnog lima na krivinama, se postiže
horizontalnim ankernim blokovima. Kao i vertikalni, tako i horizontalni ankerni blokovi, doprinose
kontrolisanom naponskom stanju u cevovodu, koje se odvija prema membranskoj teoriji 2‐D preseka.
Naponske i deformacione oscilacije na temenim tačkama trase cevovoda kao posledica povremenih
pulzacionih pritisaka u cevovodu pri stacionarnim ili incidentnim prelaznim režimima su sa ovim izbegnute.
Zavisno od tehnologije građenja čeličnog cevovoda koju će Izvođač radova primeniti, može da se ukaže
potreba za merama za ublažavanje temperaturnih uticaja u cevovodu a time i za kontrolu sila koje ti uticaji
predaju ankernim blokovima. Ukoliko Izvođač radova pribegne metodi po kojoj će se prvo položiti cevovod
a nakon toga graditi ankerni blokovi i postavljati termalna izoloacija na cevovodu, onda je bitna ambijetalna
temperatura pri kojoj će se izvršiti zadnji var na cevovdnom lancu. Ukoliko je razlika između te temperature
i prosečne temperature vode u cevovodu značajna, onda bi se iza ankernih blokova ABV22, ABV25, ABH27 i
ABH34, trebalo postaviti privremene klizne spojnice. Nakon puštanja cevovoda u rad i stabilizovanja
temperature u zidovima cevovoda, izvršilo bi se zavarivanje kliznih spojnica, čime bi se uticaj godišnje
temperaturne razlike vode na naponska stanja u nosećem sistemu cevovoda minimizirala. U svrhu
izbegavanja primene privremenih kliznih spojnica, Projektant predlaže Investitoru da se cevovod instalira sa
prethodno primenjenom termalnom izolacijom, kao i da se polaganje cevovoda i izrada ankernih blokova
vrši simultano.
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 5 of 34
cevovod
Sprečavanje erozije peščane ispune u koju se polaže cevovod, kao i podužno osiguranje kamene obloge
cevovoda tokom građenja se uglavnom obezbeđuje poptorno‐antierozionim blokovima, na crtežima
označenim sa PBi . U cilju sprečavanja mehaničkog oštećenja cevovoda u periodima bujica, ili od slučajnih
odrona, Projektant je predvideo oblogu od lomljenog kamena čija se monolitizacija obezbeđuje cementnim
malterom. Raspoloživost lomljenog kamena u zoni cevovoda je vodila Projektanta da projektuje ovu vrstu
zaštite.
Za sve vrste ankernih i potpornih blokova primeniće se Beton marke 30. Zbog oštrih klimatskih uslova u
regionu, primeniće se beton koji je otporan na mržnjenje. Maksimalno zrno agregata 25mm. Minimalna
količina cementa 350 kg. Blokovi će se ojačavati sa formiranom mrežom od CBR40/50 φ 12/12.5cm na svim
unutrašnjim i spoljnim stranama betona. U zoni interfejsa sa cevovodom a radi sprečavanja prslina u
betonu usled radijalne deformacije cevovoda, primeniće se tangencijalna armatura φ 12/10cm(po širini
bloka) duž celog obima cevovoda.
U cilju obezbeđenja stabilnih temelja za novi cevovod, Investitoru se preporučuje zapunjavanje
postojećeg cevovoda nakon prestanka njegove upotrebe. U protivnom, usled korozije starog cevovoda i
njegovog truljenja, može doći do deformacije temelnje podloge novog cevovoda i do naponskih stanja u
cevovodu sa kojima nije računato u toku glavnog projekta novog cevovoda.
Pretpostavlja se da proizvođač cevovoda koristi čelik kvaliateta STZ35JR(ST37) za proizvodnju cevi
DN400/8.8. Dozvoljeni naponi u čeliku: σt,st = 1570 (kp/cm2)/dN/cm2 za stacionarne uslove tečenja u
cevovodu, i σt,st = 1510 (kp/cm2)/dN/cm2 za nestacionarne uslove tečenja u cevovodu.
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 6 of 34
cevovod
II Proračun konstrukcije cevovoda
II.1. Proračun debljina zidova cevi
Pretpostavlja se da proizvođač cevovoda koristi čelik kvaliateta STZ35JR(ST37) za proizvodnju cevi
DN400/8.8. Pretpostavljena debljina cevovoda 8.8 mm. Dozvoljeni naponi u čeliku: σt,st = 1570
(kp/cm2)/dN/cm2 za stacionarne uslove tečenja u cevovodu, i σt,st = 1510 (kp/cm2)/dN/cm2 za nestacionarne
uslove tečenja u cevovodu.
Literatura:
Konstrukterski Prirucnik
Gradjevinska Knjiga, Beograd, 1980
pb t
pa
2r
t t
l
2r l >> r
Cross section of pipe Longitudinal section of pipe
Primena Kotlovske Formule za proracun napona usled unutrasnjeg hidro pritiska
pa × r p ×r pa × r
σt = → tef = a tef = ttot − 0.3cm → ttot = + 0.3cm
tef σt σt
Legenda : 1.0 mm, zbog gubitka materijala usled korozije
1.0mm, zbog dozvoljenih tolerancija u debljini proizvedenog lima
1.0mm, zbog dozvoljenih tolerancija u mehanickim svojstvima lima
Legenda faktora u formuli
σt Dozvoljeni napon u celiku
p Rezultujuci unutrasnji pritisak na zid cevi p= pa ‐pb
r Unutrasnji poluprecnik celicne cevi
tef Efektivna debljina zida cevi
ttot Ukupna debljina zida cevi ttot = tef + 0.3cm
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 7 of 34
cevovod
Proracun cevovoda STZ35JR(ST37), DN400/8.8
Ulazni Podaci
Zaključak: Izabrana debljina zida je u okviru debljine usvojene za cevovod. Nešto veća debljina zida
cevovoda je usvojena iz razloga superpozicije poprečnih napona(unutrašnje opterećenje) i
podužnih napona(skretne sile na krivinama cevovoda), koji u ukupnom iznosu još uvek
trebaju biti manji od dozvoljenih napona.
II.2. Proračun ograničenja za spoljnja opterećenja koja još uvek ne prouzrokuju izbočavanje
praznog cevovoda
Kriticni unutrasnji pritisak za dugacku ljusku koji izaziva lokalno izvijanje
E × t crt
2
4 × pb crt (1 − μ 2 ) × r 3 pb crt (1 − μ 2 ) × r
pb crt = → t crt = → t crt = 2 × r ×
4(1 − μ ) × r
2 3
E E
pbcrt (1 − μ ) × r
2
t crt = t tot − 0.3cm → t tot = 2 × r × + 0.3
E
Legenda faktora u formuli
tcrt Efektivna minimalna debljina zida cevovoda pri kojoj jos uvek ne dolazi do izvijanja
r Unutrasnji poluprecnik cevovoda
pbcrt Spoljnji hidrosticki pritisak na cevovod koji prouzrokuje izvijanje
Ukupna minimalna debljina zida cevovoda pri kojoj jos uvek ne dolazi do izvijanja
ttot t = t +0.3cm
tot crt
E Modul elasticnosti celicnog materijala
μ Puasonov koeficijent za celik
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 8 of 34
cevovod
Kontrola debljine lima za cevovod STZ35JR(ST37), DN400/8.8
Ulazni podaci
r Unutrasnji poluprecnik cevovoda 20.00 cm
[bar]/(kp/cm2)
Modul elasticnosti celicnog materijala 2.10E+06
E dN/cm2
μ Puasonov koeficijent 0.18
Potrebno ttot za ocekivane spoljnje hidrostaticke pritiske pbcrt
Zaključak: Izabrana debljina zida omogućuje prijem jednakopodeljenog spoljnjeg opterećenja pri
praznom cevovodu do iznosa od 22 bar‐a, tj. dN/cm2. Ovaj podatak će se imati u vidu pri
projektu mera mehaničke zaštite i oblaganja cevovoda.
II.3. Proračun max napona u cevovodu na temenima krivina
Približno Rešenje u zatvorenom obliku za naponske veličine koje se javljaju u temenima horizontalnih
krivina:
Proracun skretne sile
T S
2r Δ
R s
Δ
Δ
S = 2 * T * sin T=pa *A A=r 2 * π
2 2r
S π 90 × S
s= la = [ R × Δ ] × → s=
2 × la 180 R × Δ ×π
T
Primena Kotlovske Formule za proracun napona usled unutrasnjeg hidro pritiska
Literatura:
Konstrukterski Prirucnik
Gradjevinska Knjiga,
Beograd, 1980
pb t
pa
2r
t t
l
2r l >> r
Cross section of pipe Longitudinal section of pipe
ptot ×r
p tot = p a + s → σt =
,max tef
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 9 of 34
cevovod
Teme 25H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 26.60 [bar] 266.00 2
[t/m ]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 30.45 [t] 304.55 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 40.24 [t/m ]
2
4.02 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 306.24 [t/m2] 30.62 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Zakljucak: σt,max=1056.01 dN/cm2 je manji od
Max tangencijalni napon u temenoj tacki krivine
ptot ×r (kp/cm )/ 2 dozvoljenog napona σt,st = 1570 (kp/cm2)/dN/cm2
σt,max σt = 1,056.01 dN/cm2
,max ttot
Teme 26H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 29.80 [bar] 298.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 9.97 [t] 99.70 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 46.67 [t/m2] 4.67 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 344.67 [t/m2] 34.47 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Zakljucak: σt,max=1188.52 dN/cm2 je manji od
Max tangencijalni napon u temenoj tacki krivine
ptot ×r (kp/cm2)/ dozvoljenog napona σt,st = 1570kp/cm2)/dN/cm2
σt,max σt = 1,188.52 dN/cm2
,max ttot
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 10 of 34
cevovod
Teme 27H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 32.50 [bar] 325.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 18.24 [t] 182.35 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 50.62 [t/m2] 5.06 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 375.62 [t/m2] 37.56 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Max tangencijalni napon u temenoj tacki krivine Zakljucak: σt,max=1295.24 dN/cm2 je manji od
σt,max ptot ×r
1,295.24
(kp/cm2)/ dozvoljenog napona σt,st = 1570 (kp/cm2)/dN/cm2
σt = dN/cm2
,max ttot
Teme 30H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 35.30 [bar] 353.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 14.64 [t] 146.35 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 55.20 [t/m2] 5.52 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 408.20 [t/m2] 40.82 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Zakljucak: σt,max=1407.57 dN/cm2 je manji od
Max tangencijalni napon u temenoj tacki krivine
(kp/cm2)/
dozvoljenog napona σt,st = 1570 (kp/cm2)/dN/cm2
ptot ×r
σt,max σt = 1,407.57
,max ttot dN/cm2
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 11 of 34
cevovod
Teme 31H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 35.60 [bar] 356.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 30.05 [t] 300.50 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 54.83 [t/m2] 5.48 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 410.83 [t/m2] 41.08 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Max tangencijalni napon u temenoj tacki krivine Zakljucak: σt,max=1416.67 dN/cm2 je manji od
σt,max ptot ×r
1,416.67
(kp/cm2)/ dozvoljenog napona σt,st = 1570 (kp/cm2)/dN/cm2
σt = dN/cm2
,max ttot
Teme 35H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m ]
2
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 37.20 [bar] 372.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 21.98 [t] 219.84 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 57.89 [t/m ]
2
5.79 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 429.89 [t/m ]
2
42.99 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Max tangencijalni napon u temenoj tacki krivine Zakljucak: σt,max=1482.37 dN/cm2 je manji od
ptot ×r (kp/cm2)/
σt,max σt = 1,482.37 dozvoljenog napona σt,st = 1570 (kp/cm2)/dN/cm2
,max ttot dN/cm2
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 12 of 34
cevovod
Teme 39H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 39.90 [bar] 399.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 40.23 [t] 402.27 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 60.91 [t/m2] 6.09 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 459.91 [t/m2] 45.99 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Zakljucak: σt,max=1585.90 dN/cm2 je neznatno veci od
Max tangencijalni napon u temenoj tacki krivine
ptot ×r (kp/cm )/ 2 dozvoljenog napona σt,st = 1570(kp/cm2)/dN/cm2
σt,max σt = 1,585.90
,max ttot dN/cm2
Teme 40H: Veza prilog broj I
Proracun normalnih i skretnih sila
r Unutrasnji poluprecnik celicne cevi 0.20 [m] 20.00 [cm]
A Povrsina protocnog preseka cevi A=r * π 2
0.13 [m2]
Pritisak u cevovodu pri stacionarnom rezimu
pa strujanja (faza testiranja cevovoda), na pravim 40.00 [bar] 400.00 [t/m2]
deonicama cevovoda
Faktor konverzije uglova u radijane(π/180) 0.02
Δ
S Skretna sila pritiska S = 2 * T * sin 34.18 [t] 341.77 [kN]
2
Proracun napona u temenoj tacki zida cevovoda
Max iznos dopunskog pritiska u cevovodu na
centralnoj tacki krivine (temena cevovoda)
s 90 × S 61.58 [t/m2] 6.16 [bar]
s=
R × Δ ×π
Ukupni pritisak u cevovodu u temenoj tacki
ptot krivine p = p +s 461.58 [t/m2] 46.16 [bar]
tot a
tef Usvojena debljina zida cevi 0.58 [cm]
Zakljucak: σt,max=1591.65 dN/cm2 je neznatno veci od
Max tangencijalni napon u temenoj tacki krivine
ptot ×r (kp/cm )/2 od dozvoljenog napona σt,st = 1570 (kp/cm2)/dN/cm2
σt,max σt = 1,591.65
,max ttot dN/cm2
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 13 of 34
cevovod
II.4. Analiza stabilnosti cevovoda
II.4.1. Analiza horizontalnih skretnih sila i vertikalnih odižućih sila u poligonim tačkama cevovoda
za uslove ispitnih pritisaka u cevovodu
Fh
Sh Fv Sv
T
T
Sv=2*T*sin(Δ/2)
Sh=2*T*sin(Δ/2) Fv=Sv*cos(Δ/2+γ)
T Fh=Sv*sin(Δ/2+γ) T
Horizontalna Krivina
Skretne sile po temenima poligona cevovoda Vertikalna Krivina
r Unutrasnji precnik cevi 0.20 [m]
A Povrsina protocnog dela cevi 0.13 [m2]
ABH22 14.30 179.70 16.1 50.33 N/A N/A N/A N/A N/A
T22
ABV22 14.30 179.70 N/A N/A 12.50 8.98 39.13 37.75 10.28
T23‐ N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T24 ABV23/1 19.00 238.76 N/A N/A 5.10 13.25 21.25 20.44 5.78
T23‐ N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T24 ABV23/2 21.83 274.32 N/A N/A 13.80 12.52 65.91 62.16 21.92
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T24
ABV24 25.64 322.20 N/A N/A 12.80 9.23 71.83 69.17 19.35
ABH25 26.60 334.27 54.2 304.55 N/A N/A N/A N/A N/A
T25
ABV25 26.60 334.27 N/A N/A 17.30 1.60 100.55 98.94 17.89
T26‐ N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T27 ABV26/1 30.24 380.01 N/A N/A 22.30 4.48 146.97 141.54 39.60
ABH27 32.50 408.41 25.80 182.35 N/A N/A N/A N/A N/A
T27
ABV27 32.50 408.41 N/A N/A 3.30 16.86 23.52 22.30 7.47
ABH28 34.20 429.77 15.10 112.94 N/A N/A N/A N/A N/A
T28
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
ABH30 35.40 444.85 18.99 146.77 N/A N/A N/A N/A N/A
T30
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
ABH32 35.90 451.13 7.10 55.87 N/A N/A N/A N/A N/A
T32
ABV32 35.81 450.00 N/A N/A 12.05 6.07 94.47 92.37 19.79
T32 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
/2 ABV32/2 36.50 458.67 N/A N/A 7.15 3.96 57.20 56.71 7.50
ABH34 35.81 450.00 14.00 109.68 N/A N/A N/A N/A N/A
T34
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T35 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
/1 ABV35/1 37.30 468.73 N/A N/A 4.05 4.21 33.13 32.93 3.60
T37 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
/1 ABV37/1 38.20 480.04 N/A N/A 5.80 12.13 48.57 46.91 12.60
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T38
ABV38 38.29 481.17 N/A N/A 13.10 17.89 109.77 99.94 45.42
ABH39 39.90 501.40 47.30 402.27 N/A N/A N/A N/A N/A
T39
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
ABH40 40.00 502.65 39.75 341.77 N/A N/A N/A N/A N/A
T40
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 14 of 34
cevovod
II.4.3. Analiza stabilnosti jedinične dužine cevovoda za nagibe niveleta iz podužnog profila
Koeficijenti Sigurnosti
Cevovoda protiv klizanja
Cf ,static =
T
Ga
T
c f ,seismic =
Ga + Sa
Ulazni podaci za 1m' cevovoda
gs Zapreminska tezina celicnog materijala 7.80 t/m3 78.00 kN/m3
gw Zapreminska tezina vode 1.00 t/m3 10.00 kN/m3
Kc Koeficijent trenja pescana posteljica‐celicna cev 0.35
r Unutrasnji poluprecnik cevovoda 0.20 m
t Debljina zida cevi cevovoda 0.0088 m
a Koeficijent maksimalne horizontalne seizmicnosti 0.20
Proracun sila, za nagib nivelete cevovoda α= 5.00 stepeni
G Gravitaciona Sila ‐ Tezina cevi i vode 0.21 t/m' 2.14 kN/m'
G=0.25*(2*r)^2*p*g +2*(r+t/2)*p*t*g
w s
Transverzalna komponenta gravitacione sile
Gt Gt=G*cosα 0.21 t/m' 2.13 kN/m'
Ga Aksijalna komponenta gravitacione sile 0.02 t/m' 0.19 kN/m'
Gt=G*sinα
Sila trenja Cev‐Posteljica od peska
T T=Gt*Kc 0.07 t/m' 0.75 kN/m'
Horizontalna seizmicka sila pri max seizmicnosti S =
S G*a 0.04 t/m' 0.43 kN/m'
Aksijalna Komponenta sile seizmicnosti
Sa Sa = S*cosα 0.04 t/m' 0.43 kN/m'
Transverzalna Komponenta sile seizmicnosti
St S = S*sinα 0.00 t/m' 0.04 kN/m'
Proracun koeficijenta sigurnosti cevovoda protiv klizanja
α Cf, static Ga-T[kN] Cf, seismic (Ga + Sa)-T[kN]
Nagib
Nivelete
Sila koju primaju
ankerni blokovi
Sila Koju primaju
ankerni blokovi
5.00 4.00 ‐0.56 1.22 ‐0.13
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 15 of 34
cevovod
Proracun sila, za nagib nivelete cevovoda α= 8.00 stepeni
Gravitaciona Sila ‐ Tezina cevi i vode
G G=0.25*(2*r)^2*p*gw+2*(r+t/2)*p*t*gs
0.21 t/m' 2.14 kN/m'
Gt
Transverzalna komponenta gravitacione sile
0.21 t/m' 2.12 kN/m'
Gt=G*cosα
Aksijalna komponenta gravitacione sile
Ga Gt=G*sinα
0.03 t/m' 0.30 kN/m'
Sila trenja Cev‐Posteljica od peska
T 0.07 t/m' 0.74 kN/m'
T=Gt*Kc
Horizontalna seizmicka sila pri max seizmicnosti S =
S G*a
0.04 t/m' 0.43 kN/m'
Aksijalna Komponenta sile seizmicnosti
Sa Sa = S*cosα
0.04 t/m' 0.42 kN/m'
Transverzalna Komponenta sile seizmicnosti
St S = S*sinα
0.01 t/m' 0.06 kN/m'
Proracun koeficijenta sigurnosti cevovoda protiv klizanja
α Cf, static Ga-T[kN] Cf, seismic (Ga + Sa)-T[kN]
Nagib Sila koju primaju Sila Koju primaju
Nivelete ankerni blokovi ankerni blokovi
8.00 2.49 ‐0.44 1.03 ‐0.02
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 16 of 34
cevovod
0.47
21.00 0.91 0.07 0.60
Proracun sila, za nagib nivelete cevovoda α= 22.00 stepeni
Gravitaciona Sila ‐ Tezina cevi i vode
G G=0.25*(2*r)^2*p*gw+2*(r+t/2)*p*t*gs
0.21 t/m' 2.14 kN/m'
Gt
Transverzalna komponenta gravitacione sile
0.20 t/m' 1.98 kN/m'
Gt=G*cosα
Aksijalna komponenta gravitacione sile
Ga 0.08 t/m' 0.80 kN/m'
Gt=G*sinα
Sila trenja Cev‐Posteljica od peska
T T=Gt*Kc
0.07 t/m' 0.69 kN/m'
Horizontalna seizmicka sila pri max seizmicnosti S =
S G*a
0.04 t/m' 0.43 kN/m'
Sa Aksijalna Komponenta sile seizmicnosti 0.04 t/m' 0.40 kN/m'
Sa = S*cosα
Transverzalna Komponenta sile seizmicnosti
St 0.02 t/m' 0.16 kN/m'
S = S*sinα
Proracun koeficijenta sigurnosti cevovoda protiv klizanja
α Cf, static Ga-T[kN] Cf, seismic (Ga + Sa)-T[kN]
Nagib Sila koju primaju Sila Koju primaju
Nivelete ankerni blokovi ankerni blokovi
22.00 0.87 0.11 0.58 0.50
Proracun sila, za nagib nivelete cevovoda α= 23.00 stepeni
Gravitaciona Sila ‐ Tezina cevi i vode
G G=0.25*(2*r)^2*p*gw+2*(r+t/2)*p*t*gs
0.21 t/m' 2.14 kN/m'
Transverzalna komponenta gravitacione sile
Gt Gt=G*cosα
0.20 t/m' 1.97 kN/m'
Ga
Aksijalna komponenta gravitacione sile
Gt=G*sinα
0.08 t/m' 0.84 kN/m'
Sila trenja Cev‐Posteljica od peska
T T=Gt*Kc
0.07 t/m' 0.69 kN/m'
Horizontalna seizmicka sila pri max seizmicnosti S =
S G*a
0.04 t/m' 0.43 kN/m'
Aksijalna Komponenta sile seizmicnosti
Sa 0.04 t/m' 0.39 kN/m'
Sa = S*cosα
St
Transverzalna Komponenta sile seizmicnosti
S = S*sinα
0.02 t/m' 0.17 kN/m'
Proracun koeficijenta sigurnosti cevovoda protiv klizanja
α Cf, static Ga-T[kN] Cf, seismic (Ga + Sa)-T[kN]
Nagib Sila koju primaju Sila Koju primaju
Nivelete ankerni blokovi ankerni blokovi
23.00 0.82 0.15 0.56 0.54
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 21 of 34
cevovod
Zaključak:
Za statičke uslove cevovoda, cevovod postaje nestabilan na klizanje za nagibe veće od 17 stepeni. Tada,
ulogu podužne stabilnosti cevovoda preuzimaju ankerni blokovi.
Za seizmičke uslove cevovoda (zemljotres sa vršnim ubrzanjem od 0.2g), cevovod izražava podužnu
nestabilnost za uglove veće od 6 stepeni.
Imajući u vidu rigorozne topo uslove i skučeni prostor za izgradnju, nepostojanje ni minimalnih istražnih
radova za definisanje kvaliteta podloge na kojoj će se izvršiti fundiranje cevovoda, nepostojanje poprečnih
geodetskih profila, Projektant je usvojio kombinaciju statičkih uslova cevovoda pri ispitnom pritisku sa
pojavom zemljotresa sa horizontalnim ubrzanjem od 0.2g kao moguću, pri kojoj se analizira stabilnost
noseće konstrukcije cevovoda.
II.4.3. Projekat Horizontalnih i Vertikalnih Ankernih Blokova
Deonica cevovoda ABH/ABV 22 – ABV23/1
Tipičan sistem fundiranja cevovoda na pripadajućoj deonici:
Prosečan nagib cevovda na deonici ABH/ABV 22 – ABV23/1:
ipros = (21.5+19.1+22.3+25+20.7+13.3)*(1/6) =20.32 stepena Nova cev φ400
Dužina deonice: L=1900.10‐1775.75 =124.35 m
Jedinična podužna sila na cevovodu za nagib nivelete od 20 stepeni: Postojeca cev φ400
ΔP = 0.43 kN/m’
Podužne sile koje se predaju ankernim blokovima ABH/ABV22 i ABV23/1
pri ispitnom pritisku i pojavi zemljotresa:
P = 0.5* ΔP*L*cos20.32= 0.5*0.43*124.35*cos20.32 = 25.07 kN
0.80 0.80
0.50
16.1
0.40
0.50
0.80
50.33 kN
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 22 of 34
cevovod
Prijem vertikalne sile se obezbeđuje zasecanjem ankernog bloka u masivne krečnjake. Kontaktni napon pri
tome iznosi:
σv = 37.75/(2*0.8*0.5)= 47.188 kN/m2 = 0.47 kp/cm2 (dN/cm2)< 7.15 dN/cm2 procenjeno za
masivne krečnjake .
Prijem horizontalne sile se takođe obezbeđuje zasecanjem ankernog bloka u masivne krečnjake. Kontaktni
napon pri tome iznosi:
σv = (10.28kN+25.07kN)/(0.5*3.57)= 19.8 kN/m2 = 0.2 kp/cm2 (dN/cm2)< 7.15 dN/cm2
procenjeno za masivne krečnjake .
Deonica cevovoda ABV23/1 – ABV23/2
Tipičan sistem fundiranja cevovoda je istovetan sa deonicom ABH/ABV 22 – ABV23/1.
Prosečan nagib cevovoda na deonici ABV 23/1 – ABV23/2:
ipros = (18.4+15.5+12.5)*(1/3) =15.47 stepena
Dužina deonice: L=2000.00 ‐1900.00 =101.83 m
Jedinična podužna sila na cevovodu za nagib nivelete od 16 stepeni: ΔP = 0.28 kN/m’
Podužne sile koje se predaju ankernim blokovima ABV23/1 I ABV23/2 pri ispitnom pritisku i pojavi
zemljotresa:
P = 0.5* ΔP*L*cos15.47= 0.5*0.28*101.83*cos15.47 = 13.74 kN
Sila koja se bloku predaje iz polja ABV22‐ABV23/1:
20.22 kN Pispred =25.07 kN
Sila koja se bloku predaje iz polja ABV23/1‐ABV23/2:
0.40 25.07 kN 0.60
13.73 kN
13.25
5.78 kN Piza =13.74 kN
18.35
0.40
5.10 Prijem vertikalne sile se obezbeđuje zasecanjem
ankernog bloka u masivne krečnjake. Kontaktni napon
Min 0.50
pri tome iznosi:
σv = 20.22/(2*0.8*0.5)= 25.28 kN/m2 = 0.25 kp/cm2
0.80
(dN/cm2)< 7.15 dN/cm2 procenjeno za masivne
krečnjake .
Prijem horizontalne sile se takođe obezbeđuje zasecanjem ankernog bloka u masivne krečnjake. Kontaktni
napon pri tome iznosi:
σv = (25.07kN+5.78kN+13.74kN)/(0.5*3.57)= 24.98 kN/m2 = 0.25 kp/cm2 (dN/cm2)<
7.15 dN/cm2 procenjeno za masivne krečnjake .
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 23 of 34
cevovod
Deonica cevovoda ABV23/2 – ABV24
Tipičan sistem fundiranja cevovoda je istovetan sa deonicom ABH/ABV 22 – ABV23/1.
Prosečan nagib cevovoda na deonici ABV 23/1 – ABV23/2:
ipros = (26.3+28.4+17.7)*(1/3) =24.13 stepena
Dužina deonice: L=2111.03 ‐2001.93 = 109.10 m
Jedinična podužna sila na cevovodu za nagib nivelete od 24 stepena: ΔP = 0.58 kN/m’
Podužne sile koje se predaju ankernim blokovima ABV23/2 i ABV24 pri ispitnom pritisku i pojavi
zemljotresa:
P = 0.5* ΔP*L*cos24.13= 0.5*0.58*109.10*0.91 = 28.87 kN
0.60 Sila koja se bloku predaje iz polja ABV23/1‐ABV23/2:
13.73 kN0.40 28.87 kN Piza = 28.87 kN
8.98 21.92 kN
0.40 26.32
Prijem vertikalne sile se obezbeđuje zasecanjem
13.80
ankernog bloka u masivne krečnjake. Kontaktni napon
Min 0.50
pri tome iznosi:
σv = 62.16/(2*0.8*0.5)= 77.7 kN/m2 = 0.77 kp/cm2
0.80
(dN/cm2)< 7.15 dN/cm2 procenjeno za masivne
krečnjake .
Prijem horizontalne sile se takođe obezbeđuje zasecanjem ankernog bloka u masivne krečnjake. Kontaktni
napon pri tome iznosi:
σv = (13.74kN+21.92kN+28.87kN)/(0.5*3.57)= 36.15 kN/m2 = 0.36 kp/cm2 (dN/cm2)<
7.15 dN/cm2 procenjeno za masivne krečnjake .
Deonica cevovoda ABV24 – ABH/ABV25
Sila koja se bloku predaje iz polja ABV23/1‐ABV23/2: Piza = 4.58 kN
Prijem vertikalne sile se obezbeđuje zasecanjem ankernog bloka u masivne krečnjake. Kontaktni napon pri
tome iznosi:
σv = 69.17/(2*0.8*0.5)= 86.46 kN/m2 = 0.86 kp/cm2 (dN/cm2)< 7.15 dN/cm2 procenjeno za masivne
krečnjake.
Prijem horizontalne sile se takođe obezbeđuje zasecanjem ankernog bloka u masivne krečnjake. Kontaktni
napon pri tome iznosi:
σv = (28.87kN+19.35kN+4.58kN)/(0.5*3.57)= 29.57 kN/m2 = 0.3 kp/cm2 (dN/cm2)<
7.15 dN/cm2 procenjeno za masivne krečnjake .
Deonica cevovoda ABH/ABV25 – PB26
Tipičan sistem fundiranja cevovoda je naznačen u poprečnom preseku ankernog bloka.
1.30
0.80 1.00
63°
1.75 304.55 kN
Min 0.75
208.00 kN
0.00 126°
2.20
3.20 1.65
0.80
1.60
41.60 kN 17.89 kN
18.08 kN
18.9 Min 0.95
208.00 kN
1.00
1.00
Prosečan nagib cevovoda na deonici ABH/ABV25‐PB26 : ipros = (19.0+22.8+19.2+16.2)*(1/4)
ipros = 19.30 stepen
Dužina deonice: L=2245.02‐2155.92 = 89.10 m
Jedinična podužna sila na cevovodu za nagib nivelete od 20 stepeni: ΔP = 0.43 kN/m’
Podužne sile koje se predaju ankernom bloku ABV24 pri ispitnom pritisku i pojavi zemljotresa:
P = 0.5* ΔP*L*cos19.3= 0.5*0.43*89.10*0.94 = 18.08 kN
Proračun stabilnosti bloka protiv odizanja: Cfodizanja = 208.00kN/98.94kN = 2.10
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 25 of 34
cevovod
Masa bloka: 208.0 kN
Inercijalna sila bloka usled zempljotresa 0.2g: 208.0 * 0.2 = 41.60 kN
Proračun stabilnosti bloka protiv klizanja u transverzalnom pravcu:
Cfklizanje tr= (2.00m*1.00m*335kN/m2)/(304.55kN+0.2*208kN)= 1.94
Proračun stabilnosti bloka protiv obrtanja u transverzalnom pravcu:
Cfobrtanje tr= (208kN*1.87)/(304.55kN*0.90+98.94kN*1.0)= 1.04
Proračun stabilnosti bloka protiv klizanja u podužnom pravcu: Nije kritično.
Proračun stabilnosti bloka protiv obrtanja u podužnom pravcu:
Cfobrtanje pod= (208kN*1.00)/((18.08kN+17.89kN+41.60kN)*0.95+98.94kN*1.0)= 1.2
Deonica cevovoda ABV26/1 – ABH27/ABV27
Tipičan sistem fundiranja cevovoda je naznačen u vertikalnom preseku ankernog bloka.
BLOK ABV 26/1- Vertikalni presek BLOK ABH 26/1- Poprecni presek
141.54 kN
141.54 kN
0.72
22.30 26.78
Min 0.75 164.5 kN
164.5 kN 1.70
2.00
0.50
1.00
2.00
Prosečan nagib cevovoda na deonici ABH/ABV26/1‐ABH27/ABV27 : ipros = (26.8+16.7+16.7)/3 ipros = 20.07
stepeni
Dužina deonice: L=2333.91‐2267.42 = 66.49 m
Jedinična podužna sila na cevovodu za nagib nivelete od 20 stepeni: ΔP = 0.43 kN/m’
Podužne sile koje se predaju ankernom bloku ABV26/1 pri ispitnom pritisku i pojavi zemljotresa:
P = 0.5* ΔP*L*cos20.07= 0.5*0.43*66.49*0.9393 = 13.43 kN
Proračun stabilnosti bloka protiv odizanja: Cfodizanja =164.5kN /141.54kN = 1.16
Proračun stabilnosti bloka protiv obrtanja u podužnom pravcu:
Cfobrtanje tr= (164.5kN*1.00)/(141.54kN*0.4+39.6kN*0.95+13.43kN*0.95+164.5kN*0.2*0.875)= 1.21
Proračun stabilnosti bloka protiv klizanja u podužnom pravcu:
Cfklizanje tr= (2.00m*1.00m*335kN/m2)/(39.60kN+13.43kN + 0.2*164.6kN)= 7.8
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 26 of 34
cevovod
Masa bloka: 164.5 kN
Inercijalna sila bloka usled zempljotresa 0.2g: 164.5 * 0.2 = 32.90 kN
Deonica cevovoda ABV/ABH27 – ABH30
Tipičan sistem fundiranja cevovoda je naznačen u vertikalnom preseku ankernog bloka.
0.80
Min 0.80
16.86 0.80
Nova cev 400 φ
0.40
38.35 kN 7.47 kN 17.34 kN
0.80
38.35 kN 20.16
1.80
408.41 kN 3.30
Min 0.40 0.80
Postojeca cev 400 φ 191.76 kN
Min 2.40
10°
Min 0.50
0.75
Min 1.55
1.50
BLOK ABH 27/ABV27- Osnova
38.35 kN
1.50
408.41 kN
0.40
Min 1.55
13.43 kN
38.35 kN
Min 2.65
0.40
25.8
3.91 kN
154.20
1.29
Dužina pripadajuće deonice ispred bloka ABH/ABV 27: L=2333.91‐2267.42 = 66.49 m
Prosečni nagib deonice cevovda ABV26/1‐ ABH/ABV27: (26.8+16.7+16.7)/3= 20.07
Jedinična podužna sila na cevovodu za nagib nivelete od 20 stepeni: ΔP = 0.43 kN/m’
Podužne sile koje se predaju ankernom bloku ABV/ABH27 od cevovoda ispred pri ispitnom pritisku i pojavi
zemljotresa: P = 0.5* ΔP*L*cos20.07= 0.5*0.43*66.49*0.9393 = 13.43 kN
Dužina pripadajuće deonice iza bloka ABH/ABV 27: L=2447.30‐2424.49 = 22.81 m
Prosečni nagib deonice cevovda ABV26/1‐ ABH/ABV27: (20.0+20.0+15.1+15.1)/4= 17.55
Jedinična podužna sila na cevovodu za nagib nivelete od 18 stepeni: ΔP = 0.36 kN/m’
Podužne sile koje se predaju ankernom bloku ABV/ABH27 od cevovoda ispred pri ispitnom pritisku i pojavi
zemljotresa: P = 0.5* ΔP*L*cos17.55= 0.5*0.36*22.81*0.9535 = 3.91 kN
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 27 of 34
cevovod
Ukupna Podužna sila koja se predaje ankernom bloku ABV/ABH27 od cevovoda pri ispitnom pritisku i pojavi
zemljotresa: 13.43 + 3.91 = 17.34 kN
Proračun mase bloka: 5.44 m2 * 1.5m * 2.35t/m2 = 19.18 t = 191.76 kN
Horizontalna komponenta vertikalne skretne sile: 7.47 kN
Inercijalna sila bloka usled zempljotresa 0.2g: 191.76 * 0.2 = 38.35 kN
Proračun stabilnosti bloka protiv odizanja: Cfodizanja = 191.76kN/22.30kN = 8.60
Proračun stabilnosti bloka protiv obrtanja u podužnom pravcu:
Cfobrtanje pod= (191.76kN*0.75)/(22.30kN*0.4+(38.35+7.47+17.34)*1.80)= 1.17
Proračun stabilnosti bloka protiv klizanja u podužnom pravcu: Stabilnost na klizanje u podužnom pravcu je
osigurana sa kontra nagibom temeljne spojnice.
Proračun stabilnosti bloka protiv klizanja u transverzalnom pravcu:
Cfklizanje tr= (1.5m*1.00m*335kN/m2)/(408.41kN+38.35kN)= 1.12
Proračun stabilnosti bloka protiv obrtanja u transverzalnom pravcu:
Cfobrtanje tr= (191.76kN*0.80+2.0*1.5*335kN*0.80)/((408.41kN+38.35kN)*1.80)= 1.19
Deonica cevovoda ABV/ABH27 – ABH30
BLOK ABH 30
Blok se izvodi na deonici sa tipom fundiranja II, naznačenom na crtežima.
Ankerni blok se neće računati. Dimenzije ankernog bloka će se usvojiti po analogiji sa dimenzjama za blok
ABH/ABV 27: (a) usvaja se istovetan transverzalni presek bloka, (b) Širina bloka se smanjuje na
1.5m*(146.77/182.35) = 1.20m
Deonica cevovoda ABV32 – PB32/1
Blok se izvodi na deonici sa tipom fundiranja II, naznačenim na crtežima.
BLOK ABV32
BLOK ABV32- Vertikalni presek BLOK ABV32- Transverzalni
presek
92.37 kN
Min 2.65
92.37 kN
6.07
Min 0.80
0.80 Nova cev φ4000.93
19.79 kN 2.03 kN
0.40
38.35 kN 0.80
18.12
12.05
1.80
191.76 kN Min 0.40 0.80 Postojeca cev φ400
0.75
Min 1.55
1.50
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 28 of 34
cevovod
Blok se izvodi na deonici sa tipom fundiranja II, naznačenom na crtežima.
Dužina pripadajuće deonice iza bloka ABV 32: L=2481.08‐2469.2 = 11.88 m
Prosečni nagib deonice cevovda ABV32‐PB32/1= 18.1 stepen
Jedinična podužna sila na cevovodu za nagib nivelete od 18 stepeni: ΔP = 0.36 kN/m’
Podužne sile koje se predaju ankernom bloku ABV32 od cevovoda iza pri ispitnom pritisku i pojavi
zemljotresa: P = 0.5* ΔP*L*cos18.1= 0.5*0.36*11.88*0.95 = 2.03 kN
Proračun mase bloka: 5.44 m2 * 1.5m * 2.35t/m2 = 19.18 t = 191.76 kN
Inercijalna sila bloka usled zempljotresa 0.2g: 191.76 * 0.2 = 38.35 kN
Proračun stabilnosti bloka protiv obrtanja u podužnom pravcu:
Cfobrtanje pod= (191.76kN*0.75)/(92.37kN*0.4+38.35*1.30+(19.79+2.03)*1.80)= 1.12
Deonica cevovoda PB32/1 – PB33
BLOK ABV 32/2
Blok se izvodi na deonici sa tipom fundiranja II, naznačenom na crtežima.
Ankerni blok se neće računati. Dimenzije ankernog bloka će se usvojiti po analogiji sa dimenzjama za blok
ABH30: (a) usvaja se istovetan transverzalni presek bloka, (b) Širina bloka: 1.50m*56.71kN/92.37kN = 0. 90 m
Deonica cevovoda PB33 – PB35
BLOK ABH 30
Blok se izvodi na deonici sa tipom fundiranja II, naznačenom na crtežima.
Ankerni blok se neće računati. Dimenzije ankernog bloka će se usvojiti po analogiji sa dimenzjama za blok
ABH30: (a) usvaja se istovetan transverzalni presek bloka, (b) Širina bloka, 1.20m.
Deonica cevovoda PB37 – PB38/1
BLOK ABV37/1 i BLOK ABV38
Blok se izvodi na deonici sa tipom fundiranja I, naznačenom na crtežima.
Ankerni blok se neće računati. Dimenzije ankernog bloka će se usvojiti po analogiji sa dimenzjama za blok
ABH/ABV22: (a) usvaja se istovetan transverzalni presek bloka, (b) Dužina bloka(po osi cevovoda), 0.80m.
Deonica cevovoda ABH38 – ABH40
Ovaj deo cevovoda se polaže u prašinasto‐glinovitim materijalima. Tip fundiranja cevovoda: IV.
Stabilnost bloka će se računati po principima ravanskog modela u kome vlada ravno stanje deformacije.
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 29 of 34
cevovod
0.60
0.20
1.00
402.27 kN 0.50
0.90
0.80
47.2
1.40
132.80
0.80 Min 2.10
Skretna sila po m’ oslanjanja bloka: 402.27kN/2.0m = 201.14 kN/m’
Podaci o opterećenjima i materijalima:
6.00
1.32 3.25
4.1 mm
0.2
1.32 1.12
1.22
1.32
Naponsko deformaciona slika u ravanskom modelu sa prikazom koeficijenata sigurnosti
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 30 of 34
cevovod
II.4.4. Mere za ublažavanje temperaturnih uticaja na sile u ankernim blokovima
Zavisno od tehnologije građenja čeličnog cevovoda koju će Izvođač radova primeniti, može da se ukaže
potreba za merama za ublažavanje temperaturnih uticaja u cevovodu a time i za kontrolu sila koje ti uticaji
predaju ankernim blokovima. Ukoliko Izvođač radova pribegne metodi po kojoj će se prvo položiti cevovod
a nakon toga graditi ankerni blokovi i postavljati termalna izoloacija na cevovodu, onda je bitna ambijetalna
temperatura pri kojoj će se izvršiti zadnji var na cevovdnom lancu. Ukoliko je razlika između te temperature
i prosečne temperature vode u cevovodu značajna, onda bi se iza ankernih blokova ABV22, ABV25, ABH27 i
ABH34, trebalo postaviti privremene klizne spojnice, prema šemi koja sledi. Nakon puštanja cevovoda u rad
i stabilizovanja temperature u zidovima cevovoda, izvršilo bi se zavarivanje kliznih spojnica, čime bi se uticaj
godišnje temperaturne razlike vode na naponska stanja u nosećem sistemu cevovoda minimizirala.
U svrhu izbegavanja primene privremenih kliznih spojnica, Projektant predlaže Investitoru da se cevovod
instalira sa prethodno primenjenom termalnom izolacijom, kao i da se polaganje cevovoda i izrada ankernih
blokova vrši simultano.
Projekat Investitor:
Rekonstrukcija Vodovoda Podgor- JP Vodovod i Kanalizacija,
Cetinje Cetinje
Sveska: Konstruktivni deo za celicni Datum : April, 2010 Strana: 31 of 34
cevovod
PRILOG I
Horizontalni Prelomi Trase sa pripadajućim hidro‐pritiscima
na bazi postojećeg geodetskog snimka(novembar 2009) i vizuelne inspekcije trase od strane
projektantskog tima(decembar 2009)
Teme Skretni Ugao Hidro‐Pritisak Skica poprecnog Procenjeni inženjersko‐geološki uslovi
(Stepeni) [bar] profila
Radno Hidro Prelazni
Stanje Test Režimi
Bankoviti do masivni, podređeno slojeviti,
krečnjaci i dolomiti, beli, sivi do
Postojeca cev φ400 Nova cev φ400
rumenkasti
T25H 54.20 21.00 26.60 24.90
1.50
Bankoviti do masivni, podređeno slojeviti,
krečnjaci i dolomiti, beli, sivi do
Postojeca cev φ400 Nova cev φ400 rumenkasti
T26H 15.30 24.30 29.80 28.30
1.50
Bankoviti do masivni, podređeno slojeviti,
krečnjaci i dolomiti, beli, sivi do
rumenkasti
T27H 25.80 27.0 32.50 31.10
Bankoviti do masivni, podređeno slojeviti,
krečnjaci i dolomiti, beli, sivi do
rumenkasti
T30H 18.99 29.90 35.30 34.00
Nova cev φ400
Bankoviti do masivni, podređeno slojeviti,
krečnjaci i dolomiti, beli, sivi do
Postojeca cev φ400 rumenkasti
T31H 39.25 30.20 35.60 34.20
Bankoviti do masivni, podređeno slojeviti,
krečnjaci i dolomiti, beli, sivi do
rumenkasti
T35H 27.20 31.90 37.20 36.00
Crvenica sa odlomcima krečnjaka do 20%,
veličine fragmenata od 0.5‐3 cm.
T39H 47.30 34.70 39.90 39.00
Postojeca cev φ400 Nova cev φ400
Crvenica sa odlomcima krečnjaka do 20%,
veličine fragmenata od 0.5‐3 cm.
T40H 39.75 34.80 40.00 39.10