FINAL INSPECTION REPORT & HYDRAULIC TESTING

CLIENT : RAJASTHAN ANTIBIOTIC LTD. DATE-30/11/2018


EQUIPMENT : MS CONDENSER JOB CODE -C-285-94
FABRICATION CODE : ASME SEC-VII, DIV-1 CAPACITY- 5 SQM
S.NO DESCRIPTION REQUIRED SIZE OBSERVED MOC REMARKS
MM SIZE MM
01 SHELL OD 273 273 MS OK
02 SHELL HEIGHT 1465 1500 MS OK

03 SHELL THK 4.2 4.1 MS OK

04 DISHEND OD 273 273 MS OK

05 DISHEND THK 6 6 MS OK

06 HEADER SHELL 200 205 MS OK


LENGTH
07 HEADER SHELL THK 4.2 4.1 MS OK

08 NOZZLES QTY 6 6 MS OK

10 TUBE PLATE DIA 406 406 MS OK

11 TUBEPLATE THKNESS 20 20 MS OK

12 TUBE PIPE OD 19.05 19.05 MS OK

13 TUBEPIPE THK 2.1 2.1 MS OK

14 TUBEPIPE QTY 56 56 MS OK

15 SADDLE HEIGHT 200 200 MS OK

22 HYDRAULIC UNITS SHELL TUBE


TEST PRESSURE KG/CM2 4 4
REQUIRED
TEST PRESSURE ACTUAL KG/CM2 5 5
REMARKS:- FOUND NO LEAKAGE OR DROP IN PRESSURE DURING HYDRO TEST.

FOR MALIK POLYCHEM. Q.C DEPARTMENT