I am looking for a good position in the field of E&I in a prestigious company where previous skills and capabilities
can be put to efficient use. I possess effective organizational skills and the ability to supervise a team and develop
the final output.

SUMMARY OF SKILLS
 I have 3+ years of experience in project (procurements, installation, commissioning and maintenance) of
electrical and electronics equipment’s i.e. Transformer, Motor, VFD, Cooling Tower, LV & MV panel, LV
& MV Switchgears, HVAC plant room, Fire Alarm and Suppression system and HT & LT transmission
lines joint.
 Proven ability to focus on minute details while performing installation, maintenance, support, documentation
and testing activities to ensure compliance Proficient to the codes and standards i.e. BS, ISO, ASME, ANSI,
IEC, ISA, IEEE, etc.
 Aspiring to work in a challenging and time constraint environment to utilize my core competencies and
corporate management for the benefit of the firm.

CAREER HISTORY

Engineer Power Transmission Distribution Services Feb 2017 to Till Data


Islamabad
Giga Mall World Trade Center Islamabad
Job responsibilities
 Lead Preventive Maintenance of the Honeywell GENT’S FireNET 2127/4127 Analog Addressable Fire
Alarm System
 Conductor the replacement of FN-4127-NIC Network Interface Card
 Conductor the installation of the Short Circuit Isolator
 Lead the replacement of the Battery at main Control Panel
 Lead Preventive and Corrective Maintenance of Fire Detection and FM200 Fire Suppression System in the
MV Room, Generator Room or Power House, Transformer Room
 Lead Preventive and Corrective Maintenance of Fire detection System and FM 200 Fire suppression system
at HVAC Plant
 Replacement of the Fault Isolator and Short Circuit Isolator at different location
 Load calculations and selection of optimum cable for power sustenance and transmission.
 Lead the installation team for complete installation of 11 KV substation, HT and LT panels
 Managed the erection tram for HVAC plant, Motors and cooling tower Fan
 Conducted the insulation testing of bus Bar in HT and LT Panel that are isolate from Panel body
 Conducted insulation Testing of HV XLPE cables using Megger before laying
 Conducted the Transformer Turns Ratio (TTR) Test of different rating transformer
 Conducted the preventive maintenance of Electronic Trip Unit, Spring Charging Motor, Communication
Module and Connection of Air Circuit Breaker (ACB)
 Supervised the commission of VFD, motor and Pump for HVAC Plant
 Participate in the installation of Cooling System for Dry Type Transformer
 Conducted the correction and preventive maintenance of TC 50 Transformer temperature controller relay for
dry temperature i.e. 3MVA, 2MVA
 Participate in the replacement of PT100 in Dry Transformer
 Conducted XLPE and Power Cables Heat shrink joints, of different cable size
 Ensure the protection of generator using IEEE 1100 standard for Earthing of generator
 Supervised the installation of Intrinsic Safety Circuit or Relay for the safety of wiring in HVA Control
Room and Power House or generator Room Using ISA RP 12.6 standard
 Conducted the installation of Neutral Grounding Resistor for 2000 KVA Generator
 Participate in the replacement of the WoodWard Load Sharing Module in the EMCP 4.1 Caterpillar
 Participate in the replacement RTD at Stator and Rotor of the Caterpillar Generator
 Conductor the correction and preventive maintenance of the Seismic Probe and Proximity Probe of
Vibration
 Ensure the protection of power House or generator Room and HVAC Control Room using NFPA 12 and
NFPA 34 standard for fire extinguishing
Margalla Building, Telenor Head Office Gulberg Green Islamabad
Job responsibilities
 Participated in the commissioning of HT panel
 Conducted the Thermographic Inspection Vacuum Circuit Breaker (VCB)
 Ensure that all control and Auxiliary circuit wiring are terminated at exist place
 Checked the Communication Module and Accessories were connected
 Conducted the Inspection of arc chutes of Circuit Breaker
 Conducted the installation of Forced Cooling System for Dry Type Transformer using TC 50 Temperature
Controller Relay
 Conductor the installation Proximity Probe of the Vibration of the transformer
 Conducted the insulation testing of bus Bar in HT Panel that are isolate from Panel body
 Conducted the corrective maintenance of Fire Detection and Fire Suppression system
 Installation of Short Circuit Isolator in MV Room and Transformer Room
Fauji Foundation Hospitals (ten different sites in Pakistan)
Job responsibilities
 Lead installation and commission for Biomedical X-ray Generator (Model no N32HF) STEPHANIX
 Conducted the installation of MCCB Box and 100 Ampere 3 pole circuit Breaker
 Ensure the protection of X-ray Machine using IEEE 1100 standard for Earthing of generator
 Conducted the installation and eraction of 3 Phase energy Meter
 Conducted the eraction of 50 KVA Transformer at LT side
Fauji Foundation Medical College Rawalpindi
Job responsibilities
 Lead Preventive Maintenance of the Honeywell GENT’S Convention Fire Detection system
 Replacement of Battery at main Control Panel
 Checking of Smoke and Heat sensor
 Replacement of Faulty Sensor
 Replacement of Glass sheet at Manual Call Point(MCP)
Engineer Ali Glass Industries Hasanabdal Dec 2015 to Dec 2016
General responsibilities:
 Supervised the maintenance team for the overhauling of capacitor bank
 Supervised the installation and commissioning of VFDs for motors
 Weekly overhauling of UPS battery bank for optimum voltage and load.
 Ensure the protection of UPS Room using NFPA 12 standard for fire extinguishing system
 Managed point configuration, alarms grouping, alarms configuration, loop tuning and updating HMI
 Supervised the replacement of siemens S3-700 battery, chassis, Communication modules and working
knowledge about step 7 and Wincc.
 Ensure the protection of furnace of annealing and gradual cooling process using NFPA 86 standard for fire
extinguishing
 Overhauling of local PLC for weight bridge cells modules
 Conduct the installation and replacement of different Thermocouples using ANSI MC 96.1 standard
 Conducted the replacement of Unground Junction Thermocouple and Exposed Junction Thermocouple
 Conducted the preventive maintenance of Micrologic Trip Unit and Thermographic Inspection of Air Circuit
Breaker (ACB)
Trainee Engineer Pakistan Locomotive Factory Risalpur Sep 2015 to Nov 2015
[[

General responsibilities:
 Participated in the preventive maintenance of SF6 breakers, isolators, light arrestors, CT and PT in 132 KV
grid station
 Lead installation of VFDs for motorized loads on miller machine, driller machine, cutting machine to
optimized electric load.
 Participated in team of overhauling of control panel, metering equipment’s, ECOR
 Lead the shutdown maintenance of proximity switches.
 Participated in the vibration analysis team
 Lead the calculation for flash point of various fuels and lube oils to be used in transformer, lubricating
engines and for cooling.
 Participated in the preventive maintenance of Electronic Trip Unit of Air Circuit Breaker (ACB)
 Participated in preventive maintenance of Switchgear at 132 KV grid station.
 Participated in the preventive maintenance and updates of existing Capacitor Bank
 Participated to conduct the inspection of all ongoing activities at the Assembly line

Internee Engineer Ali Glass Industries Hasanabdal Feb 2015 to Aug 2015
General responsibilities:
 Supervised the maintenance team for the overhauling of capacitor bank
 Supervised the installation of VFDs for motors
 Weekly overhauling of UPS battery bank for optimum voltage and load
 Managed point configuration, alarms grouping, alarms configuration, loop tuning and updating HMI
 Supervised the replacement of Siemens S3-700 battery, chassis, Communication modules and working
knowledge about step 7 and WinCC
 Conducted the replacement of Unground Junction Thermocouple and Exposed Junction Thermocouple
 Produced SOPs for the checking of quality of the glass
 Conducted the preventive maintenance of Air Circuit Breaker (ACB)
 Participated in the produced SOPs for the checking of quality of the glass
 Working in the Control room

Internee Engineer Ali Engineering Services, Islamabad July 2014 to Aug 2014
General responsibilities:
 Pakistan Council of Renewable Energy Technologies (PCRET) is the vender of Ali Engineering services.
PCRET has funded to Ali Engineering services for this solar panel project
 Solar Panel installation
 Inverter installation
 Monitoring system installation
 Battery back-up system(Off-grid)
PROFESSIONAL TRAINING
 PLC SCADA and HMI Designing
Continuing Engineering Education Center University of Engineering & Technology Peshawar
 Siemens (TIA)
 Fatek
 WinCC Flexible 2008

QUALIFICATIONS
 Bachelors of Science in Electronics Engineering (Hon’s) (February, 2015)
Muhammad Ali Jinnah University Islamabad
FYP: “RFID Based Car Parking System”
 F.Sc (Pre Engineering ) June 2010
The Quaid-e-Azam College Swabi
Board of Intermediate and Secondary Education (BISE) Mardan
 Matriculation (June 2008)
Working Folks Grammar School Amnagarh, Nowshera
Board of Intermediate and Secondary Education (BISE) Mardan
KEY SKILLS

 Embedded System Design  Project Management


 Engineering Economic  Team Leadership
 AutoCAD Electrical 2015  Simulation Tools
 Load Calculation  Programmable logic controller (PLC)

IT & PORGRAMMING SKILL


 Good all round knowledge of Microsoft Word, Excel, PowerPoint, and Access
 Good working knowledge of Microsoft Project
 Basic knowledge of Electrical AutoCAD, Corel Draw
 C++, PsPice, MatLab, Proteus, PCB Wizard, AVR Studio 4, Arduino platform

LANGUAGES
 Urdu- Fluent in spoken/ writing  Pashto- Fluent in spoken
 English- fluent spoken/ writing

PERSONAL DETAILS
Father Name: Sadiq Rehman
Address : Mohallah Akhun Khail Village & P.O Shaidu,
Dist & Tehsil Nowshera KPK.
Date of Birth: 1st April, 1990
Place of Birth: Shaidu, Nowshera
Citizenship: Pakistani
Passport No: KR9152331
PEC Reg No: ELECTRO/22117