You are on page 1of 3

ADVANTEDGE RPR

Electrical Engineers, Consultants & Contractors


No 350/13, 6th Main, 2nd Block, BSK 1st Stage, Bangalore-560050 – Email: Shreelanj@gmail.com

+91- 8431038526, LinkedIn- SHREELANJ HK

Design, Installation, Testing & Commissioning, Maintenance of HT/LT Works, Switchgears- OCB, VCB,
ACB & GOS

Transformer oil Filtration, Supply & Erection of LV Panel, PCC, MCC, APFC & Custom Related Panel.

Testing & Calibrations of Relay, CT & PT. Earth Pits Testing & Reconditioning

Service of Electrical Equipment’s Fire Alarm System & Public Address System, CCTV, Water Filter,
Heaters & Conditioner

Diesel Generators Sets for Rental & Standby Transformers.

Third Party Verification & Carry out CAG compliance report.

Harmonic Mitigation Solutions with ETAP software

MEP Drawing Design Using BIM Revit, Autocad & Dialux

Our Regular Clients Include

 M/s Indian Institute of Science, Dept. of Aerospace Engineering- Bangalore - Power Quality
Study maintenance of Electrical work.
 M/s. Hindustan Unilever & Unilever Industries for servicing of HT breaker and protective relay
testing
 M/s. Aldo electrical for servicing M.E.I, Siemens and Vyoma make HT, Switchgear panels at all
their Clients Places across Bengaluru
 M.s Indo US MIM Doddaballapur for servicing of LT ACB ABB make, L&T Make.
 M/s. Sudha Electrical and Enterprises for pre commissioning test of VYOMA make VCB and
240sq.mm HT XLPE cable end termination for transformer, VCB. Termination of control cable
from Transformer marshalling box to VCB panel and OLG to RTCC panel.
 Testing the transformer faults and trouble shooting of HT and LT control systems
 M/s. Vinayaka transformer and Sri Balaji Engineering system for technical support to solve the
transformer fault signal from marshalling box to VCB panel and to get annunciation at both
RTCC as well as on VCB panels.
 Technical support to M/s. Vishwa Electricals for Servicing of HT VCB, LT ACB, LBS at High
Temp. Furnace, KEMS forging, M/s. SANKHLA POLYMER. And other client places
 Testing and commissioning of HT and LT panels at M/s. SUNIL AGRO FOODS Hosakote.
 Modification of HT VCB panel providing protective relay on HT panels with installation of HT
CTs, providing shunt trip coils and control wiring at UTC Aerospace through Maverick Facility
Management.
 Providing reverse power relay for the DG panels at TCS electronic city through M/s. ALDO
ELECTRICALS.
 Recently our team went to MALDAVIS for servicing of Lucy make RMU, Transformer, and
complete switch gear panel.
 Installation of EM6400NG MFM with CT and meter box. at Microprint & Pack Electronic city.
 Conducted study of overvoltage and harmonic analysis at HMG Granite.
 Techinical support in testing of transformers, protective relays and supply of materials to M/s.
SLK software
Harmonics reduction devices There are many ways to reduce harmonics, ranging from passive filters to
active variable frequency injection devises (Active Filters) connected to the auxiliary equipments
contributing to the harmonics. REFERENCE STANDARDS IEEE 1100 – 1999 IEEE Recommended Practice
for Powering & Grounding Electronic Equipments IEEE 519 – 2014 IEEE Recommended Practices &
Requirements for Harmonic Control in Electrical Power System. ASSUMPTIONS & LIMITATIONS This
report has been prepared on the basis of true recordings of relevant parameters, representations,
information both verbal and documented during the course of the audit. The findings mentioned in the
report are based on the observations, data & information collected during audit period with live loads
during the period of observation. The recommendations are based on International standards.
Instruments Used