SYSTEMS
(DETECTION OF HUMAN BEINGS BURIED UNDER
EARTHQUAKE)
PRESENTED
BY
R.S.S.DINESH
P.AMRIT SWAROOP
1
ABSTRACT
Introduction:
At present as we all know the need of hour is to
find an effective method for rescuing people buried under
earth quake rubble or collapsing building. So we have to
find the solution before we experience another earth
quake. Present methods for searching and rescuing victims
buried or tapped under earth quake rubble are not
effective. Hence we have designed the system with the
help of embedded system and microprocessor which will
be very much effective to solve these problems.
2
This paper has constructed a sensitive life-
detection system for such purposes using microwave
radiation.
Principles of operation:
The basic principle is that when a microwave
beam of certain frequency [L (or) S band (or) UHF band]
is aimed at a portion of rubble (or) collapsed building
under which a person has been trapped, the microwave
beam can penetrate through the rubble to reach the person.
When the microwave beam focuses the person, the
3
reflected wave from the person’s body will be modulated
(or) changed by his/her movements, which include
breathing and heartbeat. Simultaneously, reflected waves
are also received from the collapsed structures. So, if the
reflected waves from the immovable debris are cancelled
and the reflected wave from the person’s body is properly
distinguished, the breathing and heartbeat signals can be
detected. By proper processing of these signals, the status
of the person under trap can be easily judged. Thus a
person under debris can be identified.
Working Frequency:
The frequency of the microwave falls under two
categories, depending on the type and nature of the
collapsed building. They are
4
Major components of the circuit:
The microwave life detection system has four major
components. They are
5
The system is operated by a portable battery unit.
Both the 450-MHz and the 1150-MHz systems are
working well for various types of earthquake rubble and
collapsed building debris. They can detect the breathing
and heartbeat signals of trapped human subjects buried
under rubble of up to 10-ft thickness
Circuit Description:
• Phase locked Oscillator:-
The phase locked loop generates a very stable
electromagnetic wave say 1150MHZ with output power
say 400MW.
• Directional Coupler 1(10dB):-
This wave is then fed through a 10dB directional
coupler and a circulator before reaching a radio frequency
switch, which energies the dual antenna system. Also the
ten dB directional branches out one-tenth of the wave
(40MW) which is then divided equally by a directional
coupler2 (3dB).
• Directional Coupler 2( 3 dB):-
One output of the 3dB directional coupler 2
(20mW) drives the clutter cancellation unit. Other output
serves as a local reference signal for the double balanced
mixer.
• Antenna system:-
The dual antenna system has two antennas, which
are energized sequentially an electronic switch. Each
antenna acts separately.
• Clutter cancellation Unit:-
a. The clutter cancellation unit consists of
b. A digitally controlled phase shifter I
c. A fixed attenuator
6
d. A RF amplifier
e. A digitally controlled attenuator
Antenna system:
This paper have designed and constructed three types of
antennas for the microwave life-detection system. They
are:
7
Fig: Heartbeat signals measured by a reflector antenna and
a probe antenna.
Working of antenna:
1. Initially the switch is kept in position 1 (signal is
transmitted through the antenna 1)
2. A fixed attenuator
3. A RF amplifier
8
4. A digitally controlled attenuator.
9
6. Otherwise send the correction signal to the digitally
controlled phase shifter 2 to change the phase and go to
step 1.
Sophisticated systems:
Conclusion:
10
A Person Life is precious and meaningful to his
loved ones. A new sensitive life-detection system using
microwave radiation for locating human subjects buried
under earthquake rubble or hidden behind various barriers
has been constructed. This system operating at 1150 or
450 MHz can detect the breathing and heartbeat signals of
human subjects through earthquake rubble or a
construction barrier of about 10-ft thickness. Hence this
paper uses certain essential features which will reduce the
tedious process of the rescue team and effort is made for
saving invaluable human lives which brings success while
applying practically.