HI-BOND

COMPOSITE FLOOR

HB30V
Z275 GALVANIZED

LIMIT STATES
DESIGN METRIC
DEPTH FROM MAXIMUM FACTORED PHYSICAL
Note SECTION MODULUS Moment of Inertia
NEUTRAL REACTIONS
1. Load Tables are NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO PROPERTIES
CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR STEEL PROFILE
based on the design Sm Ss Im If
THICKNESS STEEL GALVANIZED DECK Y b (kN) (kN)
of ONE-WAY (mm3 x 103) (mm3 x 103) (mm4 x 103) (mm4 x 103)
(mm) (mm2) (kg/m2) (mm)
composite slabs
carrying uniformly 0.76 1005.1 8.11 18.18 19.17 848.6 1028.1 41.58 5.8 13.1 (PER METRE WIDTH)
distubuted loads on a 0.91 1207.4 9.74 24.10 25.16 1081.0 1234.7 41.67 10.8 24.9 In accordance
simple span basis. with CSA
1.22 1606.7 12.83 37.27 37.87 1582.1 1641.8 41.86 14.9 36.7
For complete design Specification
criteria see the 1.52 2009.7 16.04 47.94 48.44 2035.1 2052.2 42.04 18.4 47.3
S136-07
VICWEST Hi-Bond
Composite Floor SLAB THICKNESS 141 151 166 176 PHYSICAL
Designer's Manual. h(mm)
Slab Weight, W1(kN/m2) 2.38 2.60 2.94 3.16 PROPERTIES
2. A uniform loading in
Concrete Volume, (m3/m2) 0.099 0.109 0.124 0.134 COMPOSITE SLAB
excess of 10 kPa Base Steel Nominal (PER METRE WIDTH)
(200 psf) is often an Thickness IC d IC d IC d IC d
indication of Composite
(mm)
concentrated or Moment of
moving loads. Such 0.76 13086 99.4 15951 109.4 21018 124.4 24951 134.4 Inertia,
conditions may 0.91 13846 99.3 16864 109.3 22196 124.3 26330 134.3 I C (mm4 x 103)
require additional
1.22 15235 99.1 18533 109.1 24353 124.1 28859 134.1 Effective Depth,
reinforcing steel.
Contact VICWEST d (mm)
1.52 16521 99.0 20076 109.0 26349 124.0 31202 134.0
for additional design
Base Steel
information
Nominal 1 2 3 1 2 3 1 2 3 1 2 3
LOAD TABLE
3. Slab Thickness h, is Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span
from underside of (mm) (mm)
steel deck to top of 1600 16.2 16.2 16.2 17.8 17.8 17.8 20.0 20.0 20.0 20.0 20.0 20.0 Maximum
concrete. Maximum 1800 13.5 13.5 13.5 14.8 14.8 14.8 16.9 16.9 16.9 18.2 18.2 18.2 Specified
0.76
span is not to exceed 2000 11.5 11.5 11.5 12.6 12.6 12.6 14.3 14.3 14.3 15.5 15.5 Uniformly
32h. 2200 9.9 9.9 9.9 10.9 10.9 10.9 Distributed Load
4. Properties and loads 2200 10.7 10.7 10.7 11.8 11.8 11.8 13.4 13.4 13.4 14.5 14.5 14.5
are based on Grade in kN/m 2 (kPa)
2400 9.4 9.4 9.4 10.4 10.4 10.4 11.8 11.8 11.8 12.7 12.7 12.7
230 steel (Grade 33 2600 8.4 8.4 8.4 9.2 9.2 9.2 10.5 10.5 11.3 11.3
steel) with a 0.91
2800 7.6 7.6 8.3 8.3 9.5 9.5 10.2 Shear Bond
minimum yield stress 3000 6.9 6.9 7.5 Coefficents
of 230 MPa (33,000
3200 k 1 = 11.1084
psi) and a maximum
2600 9.7 9.7 9.7 10.7 10.7 10.7 12.2 12.2 12.2 13.1 13.1 13.1 k 2 = 55.8868
stress under
2800 8.8 8.8 8.8 9.6 9.6 9.6 11.0 11.0 11.0 11.9 11.9 11.9 k 3 = 0.1034
Factored loads of 207
MPa (29,700 psi). 3000 8.0 8.0 8.0 8.8 8.8 8.8 10.0 10.0 10.0 10.8 10.8 10.8 k 4 = 0.0397
3200 7.3 7.3 7.3 8.0 8.0 8.0 9.1 9.1 9.1 9.9 9.9 9.9
1.22
5. Load values are 3400 6.7 6.7 6.7 7.4 7.4 7.4 8.4 8.4 9.1
based on Normal 3600 6.2 6.2 6.2 6.9 6.9
Weight Concrete 3800 5.8
(density of 2300 4000
kg/m3) (145 pcf) with 3200 8.3 8.3 8.3 9.1 9.1 9.1 10.4 10.4 10.4 11.2 11.2 11.2
a minimum 3400 7.7 7.7 7.7 8.4 8.4 8.4 9.6 9.6 9.6 10.4 10.4 10.4
compressive strength 7.1 7.8 8.9 9.6
3600 7.1 7.1 7.8 7.8 8.9 8.9 9.6 9.6
of 20.7 MPa (3,000 1.52 3800 6.6 6.6 6.6 7.3 7.3 7.3 8.3 8.3 9.0 9.0
psi) and a Modular
4000 6.2 6.2 6.9 6.9 7.8
Ratio n=9
4200 5.9 5.9 6.4
4400

Continued on back
In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved
HI-BOND
COMPOSITE FLOOR

HB30V
Z275 GALVANIZED

LIMIT STATES
DESIGN
IMPERIAL
PHYSICAL DEPTH FROM MAXIMUM FACTORED
SECTION MODULUS Moment of Inertia Note
NEUTRAL REACTIONS
PROPERTIES NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO
Continued from
STEEL PROFILE CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR
STEEL GALVANIZED Sm Ss Im If DECK Y b front
THICKNESS (pounds) (pounds)
(inches) (inches2) (lb/ft2) (inches3) (inches3) (inches4) (inches4) (inches)

(PER FOOT WIDTH) .030 0.475 1.662 0.3381 0.3566 0.6214 0.7529 1.637 397 898 6. No additional

In accordance reinforcing steel is


.036 0.570 1.994 0.4483 0.4680 0.7916 0.9042 1.641 740 1706
required for the slab
with CSA
.048 0.759 2.628 0.6932 0.7044 1.1585 1.2023 1.648 1021 2515 thicknesses shown
Specification on this table. For
.060 0.949 3.285 0.8917 0.9010 1.4903 1.5028 1.655 1261 3241
S136-07 temperature
PHYSICAL SLAB THICKNESS 5.50 6.00 6.50 7.00 reinforcing (crack-
h(inches) control) steel, see
PROPERTIES Slab Weight, W1(lb/ft2) 49.0 55.0 61.0 67.0 the VICWEST Hi-
COMPOSITE SLAB Concrete Volume, (cu yd/100 ft2) 1.185 1.340 1.494 1.648 Bond Composite
Base Steel Nominal Floor Designer's
(PER FOOT WIDTH)
Thickness IC d IC d IC d IC d Manual.
Composite
(inches)
Moment of
.030 9.3306 3.863 11.9974 4.363 15.1471 4.863 18.8236 5.363 7. Hi-Bond composite
Inertia,
load capacities are
4
I C (inches ) .036 9.8735 3.859 12.6825 4.359 15.9973 4.859 19.8620 5.359 dependant on the
Effective Depth, .048 10.8665 3.852 13.9356 4.352 17.5540 4.852 21.7664 5.352 material finish of the
d (inches) steel. VICWEST
.060 11.7853 3.845 15.0941 4.345 18.9941 4.845 23.5306 5.345 publishes load tables
for ZF75 Galvanneal
Base Steel
LOAD Nominal 1 2 3 1 2 3 1 2 3 1 2 3 steel and Z275
TABLE Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span Galvanized steel. For
(inches) (inches) other finishes contact
your local VICWEST
Maximum 5'-6" 310 310 310 351 351 351 391 391 391 400 400 400
office.
Specified 6'-0" 271 271 271 306 306 306 341 341 341 376 376 376
.030
Uniformly 6'-6" 240 240 240 271 271 271 302 302 302 333
7'-0" 214 214 214 242 242 242 270 8. Loads for the deck
Distributed Load
2 7'-6" 209 209 209 236 236 236 263 263 263 290 290 290 acting as a Form
in lb/ft (psf) include Slab Weight,
8'-0" 190 190 190 215 215 215 239 239 239 264 264 264
8'-6" 174 174 174 197 197 197 219 219 242 242 W 1 and a
.036
9'-0" 161 161 161 181 181 202 202 223 construction load of
9'-6" 149 149 168 168 187 1.0 kN/m2 (21 psf)
10'-0" 139 Uniformly Distrubuted
8'-6" 201 201 201 227 227 227 253 253 253 279 279 279 Live Load
186 210 234 258 OR
9'-0" 186 186 210 210 234 234 258 258
2.0 kN/m (137 lb/ft)
9'-6" 172 172 172 195 195 195 217 217 217 239 239 239
Transverse Live
10'-0" 161 161 161 182 182 182 202 202 202 223 223 223
.048 Load.
10'-6" 150 150 150 170 170 170 190 190 190 209 209 209
11'-0" 141 141 141 160 160 160 178 178 196 196
11'-6" 133 133 133 151 151 168 9. Load Table values
12'-0" 126 126 142 allow for slab self
10'-6" 171 171 171 194 194 194 216 216 216 238 238 238 weight.
11'-0" 161 161 161 182 182 182 203 203 203 224 224 224
11'-6" 152 152 152 172 172 172 192 192 192 212 212 212
.060 12'-0" 144 144 144 163 163 163 182 182 182 200 200
12'-6" 137 137 137 155 155 172 172 190
13'-0" 130 130 147 147 164
13'-6" 124 124 140

In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved