SCHEDULE OF RATES ~
.~
Published by:
Public Works Department
Purta Bhaban, Segun Bagicha
Dhaka-1000.
Fourteenth Edition
1st January 2014
l
,---'
.L:'______ _
PREFACE
1.0 PWD Schedule of rates (SoR), 2014 is the revised edition of PWD SoR, 2011.
2.0 This PWD SoR. 2014 incorporates most of the items with all corrections and will replace PWD SoR.
2011. The nomenclature of many items has been improved by making it. more generic and
comprehensive. Items of PWD SoR-2011, which have become obsolete over a period of time or are not
in use, have been deleted. Some items have been clubbed to facilitate quick measurements.
3.0 Efforts have been made to introduce items pertaining to execution of different works by using various
electrical and mechanical equipments.
4.0 Items o.f some new and imported materials are included for better quality works.
5.0 Brand names of materials have not been included in the nomenclature of items to m~ke them generic ~r;
nature.
6.0 This SoR is based on the study of current market· rates of materials at Dhaka and other metropolitan
cities, district towns collected during the period of Jan-2013 to October 2013 and labour rates are the
current market wages.
7.0 The following are the salient features of PWD SoR. 2014.
7.1 The description of items of works of this SoR bears the adherence to PWD BOOK OF
SPECIFICATION and Bangladesh National Building Code (BNBC).
7.2 Basic rates of relevant materials are provided for convenience o~ the user.
7.3 Generally, the basic rates of materials, incorporated in the schedule, are pertaining to materials
conforming to Bangladesh Standards (80S) and other international standards available in the
market.
8.0 A tot of effort has gone into the preparation of this Schedule of Rates. I convey may deep appreciation
and sincere thanks to all the members and their associates involved in producing this PWD SoR, 2014.
9.0 Due care has been taken to publish the Schedule of Rates as correctly as possible. However, it is not
unlikely possible that some errors might have crept in. In case any error or omission is noticed, it may
be brought to the notice of the Convener, SoR Committee, PWD.
1. Md. Abul Quasem. Additional Chief Engineer (P &SP), PWD, Dhaka. Convener
2. Chitta Ranjan Das. Additional Chief Engineer (Estab. & Co-ord.), PWD, Dhaka. Member
3. Md. Mohsin Mian Additional Chief Engineer, Dhaka Zone, PWD, Dhaka. Member
5. Md. Nasir Uddin Ahamed Additional Chief Engineer, ElM Zone, PWD, Dhaka. Member
7. Md. Abdul Malek Sikder Superintending Engineer, Design Circle-1, PWD, Dhaka. Member
8. Syed Azizul Haq, PEngo Superintending Engineer, Design Circle-2, PWD, Dhaka. Member
9. Md. Abdul Hye Superintending Engineer, Project Circle-1, PWD, Dhaka. Member
10. Md. Shafiqur Rahman Superintending Engineer, Project Circle-2, PWD, Dhaka. Member
12. Md. Shahdat Hossain Superintending Engineer, Monitoring &Audit Circle, PWD, Dhaka. Member
13. Md. Mizanur Rahman Superintending Engineer, PECU Circls, PWD, Dhaka. Member
14. Shahdat Hossain Deputy Chief Architect, Department ofArchitecture, Dhaka. Member
15. Md. Sobel Rahman. Executive Engineer, Design Division-4. PWD, Dhaka. Member
!
16. Md.Shamim Akhter Executive Engineer, Design Division-6, PWD, Dhaka. Member I
j
17.
i
Md. Go/am Rahman Chief Accounts Officer, PWD, Dhaka. Member I
I
18. Md. Ahsan Habib,PEng. Executive Engineer, Design Division-2, PWD, Dhaka. Member Secretary
Associates
K.M Mostafa Hasan, Executive Engineer. PWD
Md. Marufuf Hoque, Sub-Divisional Engineer, ,",NO Design Division-2. FWD
• Md. Masud Us Salam Bhuiyan, Office Assistant, Design Dlvision-2. P\VD
Ratnadeep Bhawal, PA to EE, Design Division-2, PWD
SPECIAL NOTE
Utmost care has been taken to overcome mistakes and confusion etc. in description of items,
units, rates although there may always be chances of unwilling printing mistakes. However if
y
confusion arises in the interpretation in any item/items, unit, rates etc. and if situation so
demands, then the procuring' entity must clarify and resolve the issue and approval is to be
"~I
obtained in this regard from the competent authority (HOPE or his authorized representative).
Hence the decision given by the competent authority will be treated as final.
TABLE OF CONTENTS
12 . I
Division 04: Brickworks, Patent Stone in Floor and Fancy Screen. Block 68 ;
~
24 Division 16: Washfng, Painting, Distempering, Polishing & Varnishing 128-130
25 Division 17: Drain and Apron 131
-
26 Division 18: False Ceiling Wall Paneling I
132
I
27 Division 19: Collapsible Gate, M. S. Gate, Rolling Shutter etc. 133-135
28 Division 20: Stair &Verandah Railing and Nosing 136-137
29 Division 21: Grill Fencing, Barbed Wire Fencing 138-139 I
30 Division 22: Miscellaneous Items 140-142 I
31 Division 23: Excavation of Tank 143 i I
32 Division 24: Road and Pavement Works 144-147 !
33 Division 25: Arboriculture Work 148-149
34 Division 26: Sanitary & Water Supply Works .. 150-168
35 Division 27: Deep Tube-Well 169-187
36 Division 28: Gas Connection Works 188-190 I
- ;
37 Division 29: Termite Treatment Works 191-192
38 Division 30: Concrete Hollow Block and Paving Stone i
I 193-200
I
39 Division 31: Sub-Soil Investigation Work 201-204
40 Division 32: Laboratory Tests of ~!:!fllneering Materials * I 205-245
i;
I
CO.NVERSION TABLE
FPS AND METRIC SYSTEM
(TABLE -1TO 3)
TABLE -1
FPS METRIC METRIC FPS
. )1--- __ / '
~16J'VUY .
PWO SoR 2014 for Civil Works 2
TABLE·-2
CONVERSION FACTOR CONVERSION FACTOR
British Remarks
Metric 51 51 Metric British (FPS)
(FPS) I
Length 1 in 25.4 mm . 25.4mm 1 mm 1mm 0.0937 in 1 in =2.54 cm
1ft. 0.3048m 0,3048 m 1 cm 1 em 0.3937 in
1 yd 0.9144 m 0.9144 m 1m 1m 3.281 ft.
1 mile 1.609 km 1.609 km 1km 1 km 0.6214 mi
1 . mile 1.852 km 1.852 km 1 km 1 km 0.5399 mile I
(nautical) (nautical)
I
'-,i
Area 1 in2 6.452 cm2 6.452cm2 1 cm2 1 em 0.155 in2 i 1 in2 =645.2 mrn2 i
1 ft2 0.0929 m2 0.0929 m2 1 m2 1 m2 10.764 ft2 1 acre = 43561ft2 = 4047 m2
1 yd2 0.8361 m2 0.8361 m2 1 m2 1 m2 i 1.~96 yd2 1 km2= 247.105 acres
1 mi2 2.59 km2 ~.59km2 1 km2 1km 0.3861 mi2 1 hectre =10000 m2
acre . 0.4047 ha 0.4047 ha 1 ha 1 ha 2.471 acre
I
Volume 1 in3 16.387 em3 16.387 cm3 1 cm3 1 em3 0.061 in3 1 ft3 = 6.23911 gal = 28.316
1 ft3 0.02832 m3 I 0.02832 ml 1 m3 1 m3 35.315 tt3 liters
1 yd3 0.7648 m3 0.7648 m3 1 m3 1 m3 1.308 yd3 1 bushel =36.37 liters
1 gal (UK) 4.546 liters 4.546 liters 1 liter 1 liter 0.22 gal (UK)
1 gal (US) 3.7854 liters 3.7854 liters 1 liter 1 liter . 0.264 gal (US)
Miscellaneous Units:
=
.1 great gross = 12 gross 144 dozen
1 quire=24 sheets
1 gross=12 dozen = 144 units
1 ream:: 20 quires = 480 sheets
1 dozfJn=12 units
1 ream printing paper = 500 sheets
1 score=20 units
PWD SoR 2014 for Civil Works 3
TABLE-3
CONVERSION FACTOR CONVERSION FACTOR
Remarks
British
Metric SI SI Metric British (FPS)
(FPS)
Mass 1 gr. 0.0648 gm 0.0648 gm 1 gm 19m 15.432 gm 1 Jb =0.486 seer
1 oz 28.349 gm 28.349gm 19m 19m 0.0353 oz 1 kg = 1.072 seer
(avoir) 0.4536 kg 0.4536 kg 1 kg 1 kg 2.2051bs = 85.74 tolas
1 Ib
. (avoir)
Cone. 1lb 0.4536 kg 4.4482N iN 0.102 kg 0.2248 lb· 1 kg :; 2.2046 Ib
load/force, 1 kip 453.6 kg 4.4482kN 1 kN 1.01.96 kg 224.811b =9.807 N
mass, weight 1ton 1.016 tonne 9.964 kN 1 kN 101.96 kg 2.007 cwt 1 tonne = 10 quintal
(1016 kg) = 1000 kg
1cwt 50.80 kg 0.4982 kN =26.7923 mound
1 kg = 0.01968 ewt
1 ton = 2200 Ib
=907.2 kg.
Linear loads 1lblin 0.01786 kg/mm 0.17512 1 N/mm 0.102 kg/mm 5.711b/in 1 kg/m =9.80 N/m
(load per unit 1lb/ft. 1.488 kg/m N/mm 1 kN/m 101.96 kg/m 68.52Ib/ft. = 0.672 Ib/ft.
length) 1 kipJft. 1488.19 kg/m 0.0146 kN/m 1 kN/m 0.102 tonne/m 0.031 ton/ft
1tonlft 3.333 tonne/m 14.5939 kN/m
32.69 kN/m.
Surface 11blin2 0.0703 kg/cm2 6.895 kN/m2 1 mN/m2 10.15 kg/m2 145.0381b/in2 1 kg Ic m2 =
loads 11blft.2 4.883 kglrn 2 47.8803 1 kN/m2 101.92 kg/m2 20.885 Ib/ft2 2048.3121b/ft2
(load per unit 1kipJft2 4883 kg/m2 kN/m2 1 kN/m2 0.102 tonnel 0.00933 1 kg/cm2 = 1 atom
area) 1 tonJft2 10.937 tonne 1m2 47.8803 m2 ton/ft2 =
1 kg/m2 0.2051b/ft2
kN/m 2
107.14 kN/m2 i
I
.. ,-~ .
Density 11b/in3 0.0000277 0.00027N/m 1 N/mm3 0.1021 kg/mm3 3703.70 Ib/in3 1 kg/riln:: 0.0624 Ib/ft3 :-
(unit weight) 1lbfft3 kglmml m3 1 kN/m3 101.92 kg/m3 6.3611b1ft3
1ton/ft3 16.02 kglm3 0.1572 kN/m 3 1 kN/m 3 0.102 0.0028 tonlft3
35.90 tonne/m 3 352.08 kN/m 3 tonnelm3
Stress, 11b/in2 '0.703 kglcm2 6.895 kPa 1 mPa· 10.15 kg/cm2 145.038 Iblin2 MPa =MN/m2"= N/mm2 =
modulus of 1 kipnn2 70.3078 kg/cm2 6.895 mPa 1 kPa 101.92 kglm2 20.885 Ib/ft2 1000 kN/m 2
elasticity, 11b/ft2 4.883 kg/m2 47.8803 Pa 1 Pa =1N/m2
pressure 1 kN =224.809 Ibs
1 kg/cm 2= 14.2231b/in2
1ft. of water = 2.989 kPa
Momentl 1lb·in 11.5214 kg·mm 112.98 N·mm 1 N·mm 0.102 kg·mm 0.0088Ib·in
Torque 1lb·ft 0.1383 kg·m 1.3558 N·m 1 N·m 0.102 kg·m 0.738Ib·ft
1kip·tt 138.3 kg·m 1.3558 kN·m 1 kN·m 0.102 tonne·m 0.3293 ton·ft
1ton·ft 0.31 tonne·m 3.037 kN·m
Velocityl 1ftlsec 0.3048 m/sec 0.3048 mlsec 1 mlsec 1 m/sec 3.281 ftlsec
Speed 1 1.609 kmlsec 1.609 km/sec 1 km/sec 1 km/sec 2237.42milhr
mile/sec 0.4470 m/sec 0.4470 rnlsec
1 milelhr
Acceleration 1ftlsec2 0.3048 m/sec2 0.3048 1 m/sec2 1 m/sec2 3.281 ftlsec2
mlsec2 I
Temperature 1 degree Fahrenheit (OF) = (~o/\2)/1.8 degree Celsius (OC)
(Celsius)
PWD SoR 2014 for Civil Works 4
TABLE-4
UNIT WEIGHT OF ENGINEERING MATERIALS
Unit Weight of Different Materials . Unit Weight of M.S. Flat Bars**
Unit weight Size Wei;ht
Ma~erials
Ib/cft kg/cum inch mm* Ib/rft kg/meter
Asphalt 66 1057 3/. x 1/8 20x 3 0.32 0.471
Aluminium 165 2643 3;" x 3/16 20x 5 0.48 0.785
Bambo~ 25 400 %x% 20x6 0.64 0.942
Bitumen 65 1040 _1 x 1/8 25x 3 0.43 0.589
Brass 534 8552 1 x 3/16 25x 5 0.64 0.981
Bricks 69 1110 1x % 25x6 0.85 1.178 I
Britk ballast 60·70 960·1120 1 %x 1/8 30x 3 0.53 0.707
Brick chips 80·110 1280·11.60 1 %x3/16 30 x 5 0.80 1.178
Brick work 120 1922 1%x% 30x6 1.06 1.413
Cast iron 450 7207 1 %x 1/8 40 x 3 0.64 0.942
Cement 90 1440 1 %x 3/16 40x5 0.96 1.570
Cement concrete 140 2240 1%x% 40x6 1.28 1.884
Clay ( dry to wet) 115·130 1840·2080 .2 x 3/3/16 50 x 5 1.28 1.9625
Coal (loose) 50 800 2x% SOx 6 1.70 2.335
Copper 556 8905 UNIT WEIGHT OF M.S. SOLID SQUARE BARS
Earth (compacted & damp) 100 1600 Size WeiJht
Earth (dry & loose) 90 1440 inch mm* Ib/rft -kg/meter
Garjan timber 45·50 720-800 %x% 12x 12 0.851 1.130
Gravel 90 1440 %x% 20 x20 1.914 3.140
Lead 710 11371 1 xi 25x 25 3.403 4.906 !
Lime concrete 120 1920 UNIT WEIGHT OF M.S. Z·SECTION
Lime (slaked to fresh) 640·960 Size Weight
-1
40·60 J
Lime stone 150 2400 inch mm* Ib/rft Its/meter II
Macadam (tar) 140 2242 0/4 x %X 3/4 X 1/8 20 x 20 x 20 x 3 0.851 1.272
Marble 169 2707 %X 3/4 x%x3/16 20 x 20 x 5 1.196 1.963
Mild steel 490 7850 1 x 1 x 1/8 25x25 x 3 1.170 1.625
Pebbles 90 1440 1 x 1 x 3/16 25x 25 x 5 1.675 2.551
Plain concrete 144 2300 UNIT WEIGHT OF M.S. ANGLE
Reinforced cement concrete 150 2400 Size Weight
Sal wood 60·65 960·1040 inch mm* Ib/rft kg/meter
i Sand ldry to wet} 100·120 1600·1920 %x %x 1/8 20 x 20 x 3 0.585 0.871
i Shingles 90 1440 %x %x 3/16 20 x 20 x 5 0.837 1.374
I Silver 656 10506 %x 3hx% 20 x 20 x 6 1.063 1.601
Stone ballast 100 1600 1 x 1 x 1/8 25x 25 x 3 0.798 1.107
Sundari wood 55·65 880·1040 . 1 x 1 x 3/16 25x25x5 1.156 1.766
Surki 80 1280 11x1x% 25 x 25 x 6 1.489 2.072
Surki mortar 85·120 1360·1920 I 1 %x 1 %x 1/8 40x40x3 1.223 1.813
Tar 90 1440 - 1 %x 1 Yz x 3/16 40x40x5 1.794 2.944 I
Teak wood 45-55 720·880 1Yzx1Yzx% 40x40x6 2.339 3.485
Water at 40 C 62.45 I 1000 2 x 2 x 3/16· 50x50x5 2.432 3.729
Wrought iron 480 7688 2x2x% 20x20x6 3.190 4.427
II
2%x2%x%
3x3x %
65x 65 x 6
75x 75x 6
4.041
4.891
5.840
6.782 i
3 x 3 x 5i16 75 x 75 x 8 6.048 8.918 i
-----
** Umt weIght wIth respect to FPS measurements of matenals
* Measurements in soft conversion
pwp $oR 2014 for Civil Works 5
TABLE - 5
----,
WEIGHT OF M.S. TEES PER RFT i
Size in inch Weight in Size in inch Weight Size in inch Weight Size in inch Weight in i
Ibs. in Ibs. in Ibs. Ibs. I
i
1 x 1 x 1/8 0.81 1%x1%x% 2.35 2%x2%x% 3.64 3x3x3J8 7.20 ~
J
!
1 x1x % 1.54 13/"x1%x% 2.79 2%x2%x% 4.07 3x3x'h 9,38 I
I
1 %x 1 %x 3116 1.50 1 %x 1%x 3/16 2.11 2 %x 2 %x 5/16 5.00 3 %x 3 %x 3/8 8.49
1
1%x1%x% 1.88 2x2x1h 3.21 2 %x 2 %x 3/8 5.92 3%x3%x% 11.08 I
I
I
!
i
1 %x 1 %x 3116 1.81 2x2x3J8
I 4.64 3x3x% 4.91
I II
TABLE - 6
! Thickness in
I Weight in Thickness in Weight in Thickness in Weightin I Thickn~ss
Weight in !bs. !
!
BWG I Ibs. inch Ibs. I! inch Ibs. I in inch i
j
-. -1
24 1.01 1116 2.55 5/16 12.75 " 5/8 25,50 """
"I
!
22 1.27 118 5.10 3/8 15.30 3/4 : 30.60
J
20 1.59 3/16 7.65 7116 17.85 7/8 35.70 I
!
18 2.04 1/4 10.20 1/2
I
20.40 1 40.80
j
PWD SoR2014 for Civil Works 6
TABLE -7
CROSS-SECTIONAL AREA AND MASS OF ROUND BAR1
Nominal Size Bar No. Cross-sectional Perimeter in mm Mass per running Length per 100 kg in
(diain mm) area in mm2 meter in kg meter
25
28
Ii
8
9
491.0
616.0 -+ 78.54
87.96
3.854
4.830
25.95
20.70
TABLE - 8
+--
0.005
0.0045
0.004
+
-+-
0.0061
0.0054
0.0058
0.0076
0.0068
0.006
0.004 j
!
39 0.0075 ~ -. 0.0035 ~ 0.0043! 0.0052 I JI
40 0.0070 1 ____ O.OO~_ 0.0039. 0.0048. :
U.S. Standard Gauge is officially a weight Gauge, in oz. Per sq. ft as tabulated. The approximate thickness shown is the "Manufacturers' Standard" of thel
American Iron and Steel Institute, basetl on steel as weighing 501.6~ )~~.!:.EI!. ft ..H.~9.6 true weight plus 2.5% for average over·run in area and thickness). I
Distance Matrix (District HQ to District HQ)**
Length in Kilometre .
Dhaka (Zero Point) ~;!if~: 178 316 247 169' 205 197 109 115 242 215 96 391 338 101 149 268 37 127 163 179 164 182 178· 249 259 180 117 3
Bagerilat 178 ii:i:tl-!,\: 437 160 119 155 328 283 182 363 175 269 512 467 140 270 397 215 52 336 357 93 tOO 139 378 381 34 290 4
Bandarban 316 437 ~~,\ 469 391 427 510 301 271 85 526 225 121 651 413 167 581 350 386 376 492 476 404 49(} 563 133 439 379 6
Barguna 247 160 469 i'U( 84 120 445 352 214 396 323 281 544 584 209 303 513 284 196 406 426 209 95 286 495 413 150 360 5
Barisal 169 119 391 84 ,:;jf~ 36 366 273 135 317 244 202 465 505 131 224 435 206 117 327 348 168 19 207 416 334 109 281 5
Bhola 205 155 427 120 36 ;:{.O:l 402 309 171 353 280 238 501 541 167 260 471 242 153 363 384 204 55 243: 452 370 145 317 5
Bogm 197 328 510 445 366 40l ;-;Jl:' 274 309 437 192 291 585 141 239 344 71 169 324 328 172 235 379 190 52 454 295 201 1
Brahmanbaria 109 283 301 352 273 309 274 ~~(;'-:: 143 227 320 81 375 416 206 134 345 114 231 76 203 269 287 283 327 244 285 79 4
Chandpur 115 182 271 214 135 171 309 143 ,~9/. 198 257 67 346 450 144 105 380 149 130 218 291 195 149 220 361 215 184 221 4
Chittagong 242 363 85 3!!6 317 353 437 227 198 )iri;.;: 453 151 160 578 339 93 507 276 312 302 .418 402 330 416 489 117 366 305 5
Chuadanga 215 175 526 323 244 280 192 320 257 453 i:"l) 306 601 331 118 360 261 237 171 373 276 82 231 37 243 470 142 305 3
Comlla 96 269 225 281 202 238 291 81 67 151 306 '.{:p;:; 300 432 193 58 361 130 218 156 272 256 215 270 343 169 272 159 4
cox's Bazar 391 512 121 544 465 501 585 375 346 160 601 300 :);U{ 726 487 241 655 425 460 450 567 550 479 564 637 252 514 453 7
DinaiPur 338 467 651 584 505 541 141 416 450 578 331 432 726 :?,,~;f~: 378 485 129 310 463 469 313 374 519 329 89 595 434 342 1
FaridptJr 101 140 413 209 131 167 239 206 144 339 118 193 487 378 i.:':!)/'" 246 308 128 89 260 235 96 144 81 290 356 155 214 3
Fenl 149 270 167 303 224 260 344 134 105 93 360 68 241 485 246 ;jli/' 414 183 219 209 325 309 237 323 396 110 273 212 4
Gaibandha 266 397 581 513 435 471 71 345 360 507 261 361 655 120 306 414 ~~:.c.f;;; 239 392 399 243 304 448 259 77 524 363 271 1
Gazipur 37 215 350 284 206 242 169 114 149 276 237 130 425 310 128 183' 239 :~';9\[: 164 166 151 216 219 200' 221 294 217 99 3
Gopaiganj 127 52 386 196 117 153 324 231 130 312 171 218 460 463 89 219 392 164 {fA;: 285 305 89 91 135 374 329 54 239 4
Habiganj 163 336 376 406 327 363 328 76 218 302 373 156 450 469 260 209 399 168 285 ~·to, 257 322 340 336 380 319 338 132 4
Jamalpur 179 357 492 426 346 384 172 203 291 '418 276 272 567 313 235 325 243 151 305 2571,j:o~: 319 361 274 224 436 378 125 2
Jessore 164 93 476 209 168 204 235 269 195 402 82 256 550 374 96 ·309 304 216 89 322 -319 ~~::,.: 148 46 286 419 59 277 3
Jhalcllathi 182 100 404 95 19 55 379 287 149 330 231 215 479 519 144 237 448 219 91 . 340 361 148 ;;::1i:':~, 194 430 348 90 294 E
Jhenaidah 178 139 490 286 207 243 190 283 220 416 37 270 564 329 81 323 259 200 135 336 274 46 194' :rif·:; 240 433 105 281 2
Joyptlrhat 249 378 563 495 416 452 52 327 361 469 243 343 637 89 290 396 77 221 374 380 224 286 430 240' 'jf} 506 345 253 1
Khagr:l!chhari 259 381 133 413 334. 370 454 2M 215 117 470 169 252 595 356 110 524 294 329 319 436 419 348 433 506 .. ::(: 383 322 E
Khulna 180 34 439 150 109 145 295 285 184 366 142 272 514 434 155 273 363 217 54 338 378 59 90 105 345 383' ;O~.' 292 4
KishMeganj 117 290 379 360 281 317 201 79 221 305 305 159 453 342 214 212 271 99 239 132 125 27.7 294 281 253322 292 Q _
Kurigram 348 477 661 594 515 551 151 425 460 588 341 441 736 134 388 495 120 320 473 479 323 364 528 339 ·157, 605 444 352
Kushtia 183 ·184 499 301 222 258 144 268 235 425 49 279 573 283 96 332 212 184 180 322 227 92 236 46 194 442 15.1 256 :;
Laksbmipur 137 209 229 241 162 198 331 164 43 155 284 89 303 -472 171 62 402 171 157 239 313 222 176 248 384 172 211 242 4
Lalmonirhal 3.43 472 656 589 510 546 146 420 455 583 336! 436 731 129 383 490 115 315 468 474 318 379 523 334 152 000 439 347
Madarij)ur 90 110 327 143 64 100 287 195 71 253 186 138 401 428 73 160 358 127 59 248 269 124 77 149 340 270 113 203 ~
Magura 150 136 461 258 179 215 217 254 192 387 65 241 536 355 52 294 285 172 105 308 278 44 193 26 267 405 103 253 <
Ma~nl 63 200' 379 270 191 227 188 148 177 305 173 159 453 329 65 212 259 64 149 202 170 152 205 137 241 322 211 145
Meherpur 240201552 346 270 306 182 326 283 478 26 332 626 321 1'43 385 250 241 197 380 266 108 ·256 62 232 495 167 294 <
Moulvibazar 203 376 416 446 367 403 368 116 258 342 413 196 490 509 300 249 439 208 325 63 297 362 380 376 420 359 378 172 ~
Munslligani 27 179 329 248 169 205 221 123 128 256 216 109 404 362 102 163 292 61 127 176 203 165 183 179 274 273 181 130
Mymensingh 122 300 436 370 291 327 178 147 234 362 282 216 510 320 203 269 249 93 249 200 51 291 305 280 231 379 302 68
Na~~n 247 357 561 473 395 431 50 325 359 487 221 341 635 127 268 394 117 219 353 378 222 264 408 219 39 504 323 251 1
Narail 130 107 442 227 148 184 269 235 162 368 116 222 516 408 100 275 338 167 55 289 309 34 162 79 319 385 90 243 ~
Narayanganj 17 186 314 255 1n 213 211 107 113 240 223 94 389 352 109 147 282 51 134 161 193 172 190 186 264 258 188 115
Narsingdi 51 225 339 294 215 251 217 67 137 265 262 119 413 358 148 172 287 56 173 121 198 211 229 225 269 282 227 75 ,
Natore 210 260 524 3n 298 334 68 288 311 450 124 304 598 207 171 357 137 182 256 341 185 167 311 122 118 467 227 214 ;
Nawallganj 302 352 616 469 390 426 160 380 403 542 217 396 690 216 264 449 229 274 348 433 278 259 404 214 128 559 319 306 :
Netra1lona 158 336 444 406 327 363 217 144 270 370 321 224 518 359 239 277 288 129 285 197 96 327 340 319 270 387 338 65 ,
Nilphamari 359 488 672 604 526 562 162 436 471 598 352 452 747 57 399 505 131 330 483 490 334 395 539 350 103 615 454 363
~N~.o=a=~==I~i________~1_5_8+-24_4~2_0_8+-27_6~1_~-r2_~~_35_3-r1_43-+_7_8-r1_3_4+-3_19~_61~_2_82-r_494~_2_0_6+-4_1~4_2_3+-19~3~1_9_2+-2_18~3_3_5+-2_57~2_1_0+-2_82~_4_05-+_15_1~2_4_6 ~~
Paba 216 234 530 350 2n 308 127 294 285 456 98 310 604 266 145 363 195 186 230 347 191 141 285 96 177 473 2lou 220 :
Pancbagam 443 572 757 689 610 646 246 521 555 683 437 537 B31 94 484 590 216 415 568 574 418 480 624 434 181 700 539 447
Pat~an 204 151 426 44 41 77 401' 308 170 352 279 237 500 540 166 259 470 241 152 362 383 200 52 242' 369 141 316 !
'Pirojpur 185 66. 438 95 53 89 350 290 182 364 198 249 512 489 147 271 419 222' 59 343 364 115 33 161 401 381 56 297 ,
Rajbari 118 167 434 236 158 194 208 204 171 360 108 214 509 347 31 267 277 119 116 257 226 119 171 103 259 378 171 200 :
Ralshahi 256 306 569 423 344 380 114 334 357 496 170 350 644 205 217 403 182 228 302 387 231 213 357 168 116 513 272 260 :
Rangamati 293 415 74 447 368 404 488 278 249 78 504 203' 195 629 390 144 558 328 36~ 353 470 453 382 467 540 70 417 356 I
Rangpur 304 433 618 550 471 507 107 382 416 544 297 398 692 78 345 451 76 276 429 435 279 340 485 295 113 561 400 308
Satkbira 240 94 499 206 164 200 307 344 243 425 154 331 574 446 168 332 376 287 114 398 391 72 145 118 358 442 59 352
Sha.ri~pur 101 134 317 166 87 123 298 205 62 244 209 128 392 439 96 151 368 138 82 259 280 147 101 173 350 261 136 213
Sherpur 188 366 501 435 357 393 188 204 300 427 291 281 576 329 250 334 258 159 314 258 16 -334 370 289' 240 445 394 125
Sirajganj 134 311 447 381 302 336 72 211 246 373 176 221 522 213 190 280 142 105 260 265 109 219 316 173 124 390 278 138 :
Sunamganj 296 470 509 539 460 496 462 209 351 436 507 290 584 603 393 343 532 301 418 137 391 456 474 470 514 453 472 266 I
Sylhet 241 414 454 483 405 441 406 '153 295 380 451 234 528 547 337 287 476 246 363 81 335 400 418 414 458 397 416 210 !
Tan!Jail 92 270 406 340 261 297 105 170 204 332 209 186 480 246 148 239 176 64 219 223 87 236 275 207 158 349 273 116
Thakurgaon 407 536 720 652 574 610 210 484 519 646 400 500 795 58 447 553 179 37B 532 538 382 443 587 39B 144 664 502 411 ,
URL: www.rhd.gov.bd
... :; ..c: C I:
fRI
;j
Q.
ni
1:
'E' 'c0
5Q. C
RI 5
N
ftI
.t:I
'C'
RI
Cl
Cl
I:
'iii c ~
c: ii
01
'C'
RI
Cl
RI
I:
'~
RI
E jij
01 iii
..c: 5 :E
i
E
..
::r e!
5
.s- .. '2'
'E'
RI
01
0
RI
e'
..c: '~ e! 01 e-CD ':; :E cQj 0
III ftI
>. I: ~ .t:I
0
.:t: III .r. ftI
RI
.r. .:t: '~ ftI
..c: RI c. :E .~
;j
E-
III
m E ~ jij ;j
III ::r ""'c ~
III Cl .~
f III
I!! .r.
""0 I: U III Q.
"[
III
.c 01 01 ftI
.r. 01 .:.c
, "" III
III
oJ
E
iii
oJ
1J
III
~
01
RI
:!
ftI
:i:
.r.
CD
:! ~ ~
I:
;j
~
E
>.
0
III
Z
III
Z Z
e!
ftI
Z•
0
iii
Z
~
III
Z
Qj
Z
E-
Z
ftI
z
.t:I
RI
a.
I:
RI
a.
;j
j;j
Q. ii:
'iii'
0::
III
'ii
0::
I:
co
0::
c:
ftI
0::
""I/)iii III
..c:
(/)
Qj
..c:
(/)
.~
iii
I:
;j
I/)
>.
I/)
C
(!
III
..c:
I-
137 343 90 150 63 240 203 27 122 247 130 17 51 210 302 158 359 158 216 443 204 185 118 256 293 304 240 101 188 134 296 241 92 407
209 472 110 136 200 201 376 179 300 357 107 186 225 260 352 336 488 244 234 572 151 66 167 306 415 433 94 134 366 311 470 414 270 536
229 656 327 461 '379 552 416 329 436 561 442 314 339 524 616 444 672 208 530 757 426 438 434 569 74 618 499 317 501 447 509 454 406 720
241 589 143 258 270 348 446 248 370 473 227 255 294 377 469 406 604 276 350 689 44 96 236 423 447 550 206 166 435 381 539 483 340 652
162 510 64 179 191 270 367 169 291 395 148 17'7 215 298 390 327 526 197 272 610 41 53 158 344 368 471 164 87 357 302 460 405 261 574
198 546 100 215 227 306 403 205 327 431 184 213 251 334 426 363 562 233 30.8 646 77 89 194 380 404 507 200 123 393 338 496 441 297 610
331 146 287 217 188 182 368 221 178 50 269 211 217 68 160 217 162 353 127 246 401 350 208 .114 488 107 307 298 188 72 462 406 105 210
164 420 195 254 148 326 116 123 147 325 235 107 &7 288 380 144 436 143 294 521 308 290 204 334 278 382 344 205 204 211 209 153 170 484
43 455 71 192 177 283 258 128 234 359 162 113 137 311 403 270 471 78 285 555 170 182 171 357 249 416 243 62 300 246 351 295 204 519
155 583 253 387 305 478 342 256 362 487 368 240 265 450 542 370 598 134 456 683 352 364 360 496 7.8 544 425 244 427 373 436 380 332 646
284 336 186 65 173 26 413 216 282 221 116 223 262 124 217 ·321 352 319 98 437 279 198 108 170, 504 297 154 209 291 176 507 451 209 400
89 436 138 241 159 332 196 109 216 341 222 94 119 304 396 224 452 67 310 537 237 249 214 350 203 398 331 128 281 227 290 234 186 500
303 731 401 536 453 626 490 404 510 635 516 389 413 598 690 518 747 282 604 831 500 512 509 644 195 692 574 392 576 522 584 528 4$0 795
472 129 428 355 329 321 509 362 320 127 408 352 358 207 216 359 57 494 266 94 540 489 347 205 629 78 446 439 329 213 603 547 246 58
171 383 73 52 65 143 300 102 203 268 100 10~ 146 171 264 239 399 206 145 484 166 147 31 217 390 345 168 96 250 190 393 337 146 447
62 490 160 294 212 365 249 163 269 394 275 147 172 357 449 277 505 41 363 590 259 271 267 403 144 451 332 151 334 280 343 287 239 553
402 115 358 285 259 250 439 292 249 117 338 282 287 137 229 288 131 423 195 216 470 419 277 182 558 76 376 368 258 142 532 476 176 179
171 315 127 172 64 241 208 61 93 219 167 51 56 182 274 129 330 193 188 415 241 222 119 228 328 276 287 138 159 105 301 246 64 378
157 468 59 105 149 197 325 127 249 353 55 134 173 256 348 285 483 192 230 568 152 59 116 302 363 429 114 82 314 260 418 363 219 532
239 474 248 308 202 380 63 176 200 378 289 161 121 341 433 197 490 218 347 574 362 343 257 387 353 435 398 259 258 265 137 81 223 538
313 318 269 278 170 266 297 203 57 222 309 193 196 185 278 96 334 335 191 418 383 364 226 231 470 279 391 .280 16 t09 391 335 87 382
222 379 124 44 152 108 362 165 291 264 34 172 211 167 259 327 395 257 141 480 200 115 119 213 453 340 72 147 334 219 456 400 236 443
176 523 77. 193 205 256 380 183 305 408 162 190 229 311 404 340 539 210 285 624 52 33 171 357 382 485 145 101 370 316 474 418 275 587
248 334 149 26 137 62 376 179 280 219 79 186 225 122 214 319 350 282 96 434 242 161 103 168 467 295 118 173 289 173 4Z0 414 207 398
384 152 340 267 241 232 420 274 231 39 319 264 269 118 128 270 103 405 177 181 451 401 259 116 540 113 358 350 240 124 514 458 156 144
172 600 270 405 322 495 359 273 379 504 385 258 282 467 559 387 615 151 473 700 369 381 378 513 70 561 442 261 445 390 453 397 349 664
211 439 113 . 103 211 167 378 181 302 323 90 186 227 227 319 338 454 246 200 539 141 56 177 272 417 400 59 136 394 278 472 416 273 502
242 347 203 253 145 294 172 130 68 251 243 11~ 75 214 306 65 363 221 220 447 ~1ti 297 200 260 356 308 I 352 213 125 138 266 2to 116 411
482 29 438 365 339 331 519 372 329 197 418 362 368 217 309 368 111 504 276 196 550 499 357 263 639 56 456 449 339 223' "613 ::-57 2EE 159
262 288 164 73 120 58 362 194 234 172 125 199 210 76 168 273 303 297 49 388 257 207 65 122164 188 243 127 .455 400 161 351
476 249
-::r/: 477 98 219 200 310 279 150 257 361 189 135 160 338 430 292 493 35 312 578 197 209 198 384 206 438 270 89 322 268' 373 317 227 541
477 ":I}'~ 433 360 334 326 514 367 '324 192 413 357 363 212 304 363 106 499 271 191 545 494 352 258 634 51 451 444 334 218 608 552 251 154
98 433 §:::: 121 133 212 289 91 213 337 90 98 137 240 332 249 449 133 214 534 99 111 100 286 304 395 172 23 278 224 382 326 183 497
219 360 121 '::~0 108 91 348 151 247 245 SIl' 158 197 148 241 283 376 254 122 461 214 158 75 194 439 322 115 144 294 200 442 386 192 424
200 334 133 106 i'{O}1 178 242 89 138 239 158 80 90 202 294 174 350 221 169 435 226 208 55 246 356 296 224 156 186 125 335 280 84 398
-- 310 326 212 9.1 178 j~;it~ 420 241 272 211 142 248 268 114 206 311 342 345 88 426 305 223 122 160 529 287 180 235 281 165 513 457 199 390
279 514 289 348 242 420 :,::0.::. 216 240 418 329 201 161 381 474 237 530 258 387 614 402 383 297 427 393 475 438 299 298 305 117 58 264 578
150 367 91 151 89 241 216 ,\9:/ 147 271 131 15 65 234 327 182 383 172 240 468 204 186 129 280 307 328 240 101 212 158 310 254 117 431
257 324 213 247 138 272 240 147 j;A:,: 229 253 137 135 192 284 39 340 278 198 425 326 308 194 238 413 286 362 223 69 115 '334 278 94 388
381 192 337 245 239 211 418 271 229 -;;ii'( 296 261 267 97 96 268 142 403 156 219 430 379 237 78 536 153 336 348 238 122 512 456 156 182
189 413 90 50 156 142 329 131 253 298 'W*; 138 177 201 293 289 429 223 175 513 183 114 122 247 419 374 103 t14 318 252 422 366 223 477
135 357 98 158 80 248 201 15 137 261 136 r'o§ 49 224 317 172 373 157 230 458 212 193 135 270 292 318 247 108 202 148 294 239 107 421
160 363 137 197 90 268 161 65 135 267 177 49 :'3)'\ 230 322 140 378 181 236 463 250 232 146 276 316 ~124 286 147 200 153 254 198 112 426
338 212 240 148 202 114 381 234 192 97 201 224 230 \0'( 92 231 228 366 59 312 333 282 140 46 501 173 239 263 201 65 475 419 119 276
430 304 332 241 294 206 474 327 284 96 293 317 322 92 A .. 323 230 458 151 308 425 375 232 46 593 265 332 356 293 177 567 511 211 271
292 363 249 283 174 311 237 182 39 266 289 172 140 231 323 ,~(r, 379 286 237 464 362 343 230 277 421 325 398 259 96 154 331 275 133 427
493 106 449 376 350 342 530 383 340 142 429 373 378. 228 230 379 ·Q.i: 514 286 68 561 510 368 274 649 55 467 459 349 233 623 567 267 62
35 499 133 254 221 345 258 172 278 403 223 157 181 366 458 286 514 ><9:~; 347 599 232 244 233 412 185 460 305 124 344 289 352 296 248 562
312 271 214 122 169 88 387 240 196 156 175 230 236 59 151 237 286 347 t-tlijf: 371 307 25fi 114 105 507 232 213 237 207 91 481 425 125 335
578 191 534 461 435 426 614 468 425 219 513 458 463 312 308 464 68 599 371 :~~~ 645 595 453 296 734 140 552 544 434 318 708 652 352 37
197 545 99 214 226 305 402 204 326 430 183 212 250 333 425 362 561 232 307 61'. ,M} 85 193 379 403 506 197 122 392 337 495 440 296 609
209 494 111 158 208 223 363 186 306 379 114 193 232 282 375 343 510 244 256 5b~ 85 /~~;;i; 174 3~8 .415 455 112 134 373 334 477 421 278 558
198 352 100 75 55 122 297 129 194 237 122 135 146 140 232 230 368 233 114 453 193 174 ff'm:~ . 186 412 313 190 123 241 180 391 335 139 416
364 258 286 194 248 160 427 280 236 78 .. 247 270 276 46 46 277 274 412 105 296 379 328 186 :"\0:';
547 219 285 309 247 131 521 465 164 260
206 634 304 439 356 529 393 307 413 538 419 292 316 501 593 421 649 185 507 734 403 415 412 547 " ~O··'· 595 476 295 479 424 487 431 383 698
438 51 395 322 296 287 475 328 286 153 374 318 324 173 265 325 55 460 232 140 506 455 313 219 595: :0;,' 412 405 295 179 569 513 213 103
270 451 172 115 224 180 438 240 362 336 103 247 286 239 332 396 467 305 213 552 197 112 190 285 476 412 ~;:ll ::-: 195. 406 291 531 476 307 515
89 444 23 144 156 235 299 101 223 348 114 108 147 263 356 259 459 124 237 544 122 134 123 309 295 405 195 X:.aS_ 289 234 392 337 193 507
322 334 278 294 186 281 298 212 69 238 318 202 200 201 293 96 349 344 207 434 392 373 241 747 479 295 406 289 :·'!:vS 124 391 335 103 397
268 218 224 200 125 165 305 156 115 122 252 148 153 65 177 154 233 289 91 318 337 334 180 1~1
- 424 179 291 234 124 ":if' 398 342 42 281
373 608 382 442 335 513 117 310 334 512 422 294 254 475 567 331 623 352 481 708 495 477 391 521 487 569 531 392 391 396 :<'6.: 68 357 671
317 552 326 386 280 457 58 254 278 456 366 239 198 419 511 275 567 296 425 652 440 421 335 465 431 513 476 337 335 342 68 >p . 301 616
227 251 183 192 84 199 264 117 94 156 223 107 112 119 211 133 267 248 125 352 296 278 139 164 383 213 307 193 103 42 357 301 :,,·(V 315
.().
541 154 497 424 398 390 578 431 388 182 477 421 426 276 271 427 62 562 335 37 609 558 416 260 698 103 515 507 397 281 671 616 315
~.
Note: This is a indicative distance chart. Users are requested to verify the distances before USing. District Head Quarters have been considered on the nearesf RHD Roads .
Shortest route has been considered for measuring the distance. For the same destination if the aitenate route is usesd then distence will vary.
PWDSoR 2014 for Civil Works 9
• Standard Bricks (9.5" x 4.5" x 2.75")1000 Nos. = approx. 72 cft. = 2.039 cum = 3172 to 4000 kg.
=
• 1 Ton of C.I. Sheet (24 B.W.G.) 10 bundles
• 1 bundle =
• 1 gallon of plastic emulsion paint / synthetic enamel paint covers 300 sft. of new surface (approx.)
• 100 eft masonry brick work requires 1100 nos standard bricks (size 9.5" x 4.5" x 2.75") with 0.25" thickness
~~~ .
Brick Soling:
• Single brick flat sQling requires : 300 Nos. bricks per % sft. (Brick size 9.5" x 4.5" x 2.75")
• Double brick flat soling requires : 600 Nos. bricks per % sft. (BriCK size 9.5" x 4.5" x 2.75")
• Herringbone bond (HBB) brick soling requires : 500 Nos. bricks pre % sft. (Brick size 9.5" x 4.5" x 2.75")
• Brick on end edging requires : 250 Nos. bricks per % rft. (Brick size 9.5" x 4.5". x 2.75")
PWD SoR 2014 for Civil Works 10
40 Carriage of earth by any means for site development in Rajshahi I Barishall Khulna Tk. 4.43 eft
city
41 Carriage of earth by any means for site development in all districts except Dhaka, Tk.. 3.65 eft
Ctg, and N'ganj.
42 5-ton capacity truck-fare in Dhaka city inlc loading, unloading Tk. 1,300.00 Per trip
43 Concrete mixer machine Tk. 1,000.00 Per day
44 Concrete vibrator Tk. 500.00 Per day
45 Hire charge of water pump for concreting or similar purposes Tk. 432.00 Per day
46 Hire charge of diesel operated 114 cusec water pump Tk. 588.00 Per day
47 Hire charge of electricity operated 1cusec water pump Tk. 760.00 Per day
48 Hire charge of 1cusec diesel operated water pump Tk. 1,030.95 Per day
49 Fuel, lubricant for mixer machine, vibrator and pump etc. Tk. 1,051.00 Per day
50 Mosaic cutting machine Tk. 300.00 Per day
51 Marble cutting and shaping in/c cutting disc. Tk. 300.00 Per day
52 Marble polishing machine in/c polishing stone Tk. 400.00 Per day
53 Hire charge of marble cutting disk Tk. 775.14 Per day
54 Hire charge of electric grindi'ng machine Tk. 206.00 Per day
55 Hire charge of cast in situ pile boring completE.. '] set inlc operational expenses Tk. 8,820.00 Per day
56 Hire charge of pre-cast pile driving complete rig set in/c -do-do- etc. Tk. 10,550.00 Per day
57 Hire charge of pre-cast micro pile driving complete rig set inlc -do-do- etc. Tk. 5,500.00 Per day
58 Hire charge of load testing devices in/c hydraulic fluid: up to 125 ton capacity Tk. 10,642.00 Per test
59 -do -do-: up to 275 ton capacity Tk. 12,519.00 Per test
60 ' Hire charge of diesel hammer mounted completed rig set. Tk. 23,707.00 Per day
61 Lifting and movement of crane for diesel mounted hammer up to site Tk. 50,000.00 Per set
62 Truck fare for carrying diesel hammer mounted rig Tk. 12,000.00 Per trip
PWO SoR 2014 for Civil Works 12
63 Hire charge for 8- 12 ton road roller Tk. 5,063.00 Per day
64 Hire-charge of chain dozer Tk. 12,774.45 Per day
65 Fuel &lubricants, sparss, maintenance, driver etc. for 8-12 ton road roller. Tk. 1,268:00 Per day
66 Hire charge of paint spray machine' Tk. 4.00 Per sft.
67 Small boat Tk. 688.00 Per day
68 Drum (defects free) Tk. 1,605.20 each
69 Hire charge of boring rig for soil exploration Tk. 5,313.00 Per day
70 Machine charge for cutting terrazzo tiles Tk. 406.00 . Per %sft.
71 Chisel for heavy duty power hammer (100sft. capacity) Tk. 1,594.00 each
72 Hire charge of heavy duty chisel machine Tk. 634.00 Per day
73 Shuttering in/c prop for partial dismantling of R.C.C. Tk. 20.00 Per sft.
74 Hire charge of welding machine Tk. 695.38 Per~day
75 Hire charge of survey instrument (Levell Theodolite etc.) Tk. 884.00 Per day
/<1:~1',,·.···.,::
~., .•. ".::."•.•.,..".• :.:••>. .·,."C'-:"~ ~·i.·0::·:,:'~'·~ "j:.• ':": ...::.::: :·{··,i':,··L··.··/:·'···· ::·.'f,.i':. .
..;:;." ~:.i.· I:ib·~:,;;;·.···:.,:.:,·····.·.:}.;:.·. r , , ' :>;;;:i.:.)i;:;,;;
DY:'-··.: ·:':;·;r.:<:·;:::·'·.,-;":.:':.·: c:;·;" .. '/'. ' .........,. ·,<:":,,,,;\f/:· :':?"'::':::{:'.:.~"');';':;:};.'.," ~
99 1st class/Picked jhama standard bricks: BOS Tk. 7,500.00 Per % aNos.
100 Automatic Machine Made 1st class standard Bricks: BOS Tk. 9,000.00 Per % aNos.
101 1st class 10 holes machine made 9.5"x4.5"x2.75" ceramic bricks Tk. 17,500.00 Per % aNos.
102 9.5· x 4.5" x 2.75" size machine made solid klinker facing bricks Tk. 13,125.00 Per % aNos.
9.5· x 4.5" x 2.75" size 10 hole machine made Rock-faceltexturedklinker facing
103 bricks Tk, 13,067.83 Per % aNos.
104 9S x 4.5" x 2.75" size 3 hole machine made reinforcing facing bricks Tk. 20,000.00 Per % 0 Nos.
105 200 x 100 x 50 mm/8" x 4" x 2" machine made hard pressed klinker.facing bricks Tk. 18,500.00 Per % 0 Nos.
106 200 x 50 x 50 mm/8" x 2" x2" machine made klinker facing RED or Maroon strips Tk. 14,000.00 Per % 0 Nos.
107 200 x 62 x15.51 mm/8" x 2.fJ x 0.65" machine made klinker red strips Tk. 16,750.00 Per % 0 Nos.
108 4" x4" X4" fancy screen block Tk. 28;000.00 Per % 0 Nos.
109 5.5" x 5.5" x 4" fancy screen block Tk. 28,000.00 Per%O Nos.
110 6" x 6" X4" fancy screen block· Tk. 32,000.00 Per % aNos.
111 190 mm x 190 mm size glass ~ricks Tk. 328.33 each
.,,: .. :.......
:. :". ;:.";~>..'<::;;{ ;~:h.;;'.,""o~;'·<'··. .'" ·•. /i;;(,. .. ';:'~/·;{;j:;·':·"{~~i,·:;;;,i .· .:;·:;: ..:?:·:,i:';:~>;t2;<; 1:'?"'::;:'2~'~':",;H:::<:+~::,;";:
".
,:<'~
:.:j .. ~.:-,;),: ,';;:;;>~.:.: .i. ,·;.i/;:;';' :"~.L",,,<'/T';~t;<jrl' .:/. .... , . . . . .·,·'<">,.;:"'5/i,';' ",-,<.< ;: ,·····.·:;·.:)\\·;~i,fd .'.'
Ordinary Portland Cement, BDS-EN - 197-1- CEM1, 52.5N (52.5MPa)/ ASTM C- 470.00 Per bag
112 Tk.
150 Type-I, 50 kg bag
I
I
Portland Composite Cement I CEM-IIIA- M, 42.5N (42.SMPa) (6-20% constituents 440.00 Per bag
113 other than clinker): 50 kg bag Tk.
137 Water-reducing high range retarding admixture in concrete: Tk. 147.00 Per litre
Type - G .
138 Micro Fibre for concrete Tk: 725.00 Per
..........•....•. ~~.:.";,':
·;,3;.·.• >:;;·!:~; ;.;'S:::.>::\
l····;.····.. ',:;;.(.
• ....•.••..•... " " . . . , ' ," ;c/" < .....", •• L2;~' . .~.''' . '": :,;;;y ';':"."'; ":.. ."\"
139 Royalty of earth Tk. 700.00 Per % 0 eft.
140 Royalty of sand Tk. 6,875.00 '. Per % 0 eft.
I
I
161 Melamine board (12 mm thick): 8' _ON X 4'-0" size: 700kg/m3 Tk. 1,946.50 Per pc.
162 9 mm thick gypsum board Tk. 25.98 Per sft.
PWD SoR 2014 for Civil Works 15
~!~"~1~fh; ;~~i;··:·:'·;····:A~~,:,:~~~ltt:~.~~:~§~!1':l::~~·:Wf·;.'. ~'·'··'':~';'~·~~··~·<:';·:2·:·<2··'g<.,,,1l·.,.,.·'·:i···;r·. ili:·"J2;,;./·if:.,· ·:;· ·"t!·,.2il ;~:Sf~,; ·i: Lr>'·2:,~J·12i'\'P.\{£;,: ili':i~>:>'3'~" 3LC~·; '.k'·\'<'k:'8·",·':· £· "'i.:.~. ':!1l£'.)'~: .:,'.
180 18 mm thick marble stone, Blacklwhite (Indian) Tk. 395.00 Per sft.
181 16 mm thick marble stone, Black/white (Indian) Tk. 350.00 Per sft.
182 12 mm thick marble stoner Black/white (Indian) Tk. 315.00 Per sft.
183 18 mm thick colored! grey marble stone (Indian) Tk. 410.00 Per sft.
184 16 mm thick colored! grey marble stone (Indian) Tk. 360.00 Per sft.
185 12 mm thick colored/ grey marble stone (Indian) Tk. 345.00 Per sft.
186 18 mm thick colored! grey marble slone (Italian) Tk. 550.00 Per sft.
~~--------------------------------------~--~~------~----------~
187 wall tiles less than, equal or equivalent to 250mmx330mm in sizes Tk. 46.00 Per sft.
188 wall tiles more than 250 x 330 mm & less than 310 x510 mm in sizes or equivalent Tk. 54.00 Per sft.
189 wall tiles more than 310 x'510 mm in sizes or equivalent. Tk. 75.00 Per sft.
190 GP (Gress Porcellanato) - Glazed Homogeneous 300 x 300 mm floor tiles Tk. 64.00 Per sft.
191 GP ~Glazed Homogeneous) 400 x 400 mm floor tiles Tk. 74.00 Per sft.
192 GP (Mirror polished) 300 ~ 300 mmfloor tiles Tk. 78.00 Per sft.
-1'-
193 GP (Mirror polished) 400 x 400 mm floor tiles Tk. 88.00 Per sft.
PWD SoR 2014 for Civil Works 16
196 Unglazed Homogeneous Floor Tiles 300 x 300 mm Tk. 68.00 Per sft.
197 Unglazed Homogeneous Floor Tiles 400 x 400 mm Tk. 75.00 Persft.
211 Adjustable mechanism in/c top and bottom plate Tk. 550.00 Per set
212 I-section jOist to support inclined prop Tk. 482.00 Per rft.
213 4" x 2" M.S. box channel with 1/8" thick M.S. sheet Tk. 450.00 Per rft.
214 Steel prop with adjustable mechanism in/c top and bottom plate Tk. 1,680.00 Per set
217 Weather coat I Acrylic based exterior emulsion Tk. 318.40 Per liter
~
PWD SoR 2014 for Civil Works 17
228 Acrylic Plastic Emulsion Paint sealer Tk. 205.00 Per liter
229 Acrylic Emulsion Paint Tk. 228.70 Per liter
234 Textured Coating in/csealer, top coat, gloss finish Tk. 288.93 Per liter
235 Wood varnishing: Yacht ( alkyd based) Tk. 250.00 Per liter
236 Wood varnishing: Egg-shell ( alkyd based) Tk. 250.00 Per liter
237 Wood varnishing: Matt ( alkyd based) Tk. 250.00 Per liter
238 Thinner for alkyd based wood varnishing Tk. 104.00 Per liter
-
243 Foam lub +k. .~
""';;jS'~'.;,,C i
."·it{';",< . </",;;\ S,:,;;:;>i!:.· "
:.. >,:••:"':""'~""".'"'.'.''' ""." "":'::::::.
Rate
I. Aluminium Channell Sections: Rate per rft. Unit
Bronze Silver S.SColor
252 101.60 mm, 44.45 mm wall frame of 1.2 mm thick Tk. 117.60 Tk. 115.50 Tk. 119.70 per rft.
254 16.54 mm, 15:49 mm Door glass bit of 0.99 mm thick . Tk. 15.75 Tk. 14.70 Tk. 16.80 per rft.
255 101.54 mm, 42.93 mm closure system of 1.8 mm thick Tk. 123.90 Tk. 120.75 Tk.126.00 per rft.
256 101.60 mm closure cover of 1.2 mm thick Tk. 47.25 Tk. 46.20 Tk. 48.30 per rft.
257 101.60 mm, 12.70 mm floor bottom of 4 mm thick Tk. 133.35 Tk. 129.15 Tk. 135.45 per rft.
258 82.60 mm, 43.99 mm door shutter bottom of 1.8 mm thick Tk. 158.55 Tk. 154.35 Tk. 161.70 per rft.
259 51 mm, 43.99 mm door shutter top of 1.8 mm thick Tk. 130.20 Tk. 126.00 Tk. 132.30 per rft.
101.60 mm, 38.10 mm,25.4 mm door handle (short) of 2.3 per rft.
260 Tk. 175.35 Tk. 170.10 Tk.178.50
mm, 2.3 mm, 4.01 mm thick
261 101.60 mm, 44.45 mm top &side 1.8 mm thick Tk. 151.20 Tk. 147.00 Tk. 154.35 per rft.
262 101.35 mm, 44.45 mm bottom of 1.2 mm thick Tk. 112.35 Tk. 109.20 Tk. 114.45 per rft.
263 44.32 mm, 19.61 mm fixed bottom cover of 1.2 mm thick Tk. 42.00 Tk. 40.95 Tk:. 43.05 per rft.
264 83.21 mm, 16.00 mm fixed grouve cover of 1.2 mm thick Tk. 65.10 Tk. 64.05 Tk. 66.15 per rft.
265 39.09mm, 14.81 mm fixed glass protector of 1.0 mm thick Tk. 25.20 Tk. 24.15 Tk. 26.25 per rft.
267 75.50 mm, 17.79 mm outer low bottom Of 1.2 mm thick Tk. 61.95 Tk. 58.80 Tk. 63.00 per rft.
268 75.5 mm, 26.8 mm outer top of 1.2 mm thick Tk. 86.10 Tk. 82.95 Tk. 88.20 per rft.
269 33 mm, 26.80 mm, 22 mm shutter top of 1.2 mm thick Tk. 57.75 Tk. 55.65 Tk. 58.80 per rft.
270 60 mm, 24 mm shutter bottom of 1.2 mm thick Tk. 81.90 Tk. 79.80 Tk. 84.00 per rft.
271 75.50 mm, 19.90 mm outer side of 1.2 mm thick Tk. 67.20 Tk. 65.10 Tk. 68.25 per rft:
272 49.20 mm, 26.20 mm shutter lock of 1.2 mm thick Tk. 75.60 Tk. 73.50 Tk. 77.70 per rft.
PWD SoR 2014 for Civil Works 19
274 31.75 mm shutter divider of 1.2 mm thick Tk. 63.00 Tk. 60.90 Tk. 64.05 per rft.
275 31.00 mm, 26.00 mm sliding fixed side of Tk. 4B.30 Tk. 46.20 Tk. 49.35 per rft.
276 7.14 mm spandrel of 1.4mm to 1.2mm thick Tk. 70.35 Tk. 68.25 Tk. 72.45 per rft.
277 75.50 mm, 32 mm outer bottom (high) of 1.2 mm thick Tk. 7B.75 Tk. 76.65 Tk. BO.B5 per rft.
I
278 75.5 rom, 26.80 mm outer top of 1.2 mm thick Tk. 86.10 Tk. 82.95 Tk. 8B.20 per rft. I
279 37.78 mm, 31.78 mm bottom cover of 1.2 mm thick Tk. 33.60 Tk. 32.S5 Tk. 34.65 per rft.
280 "7-6.20 mm, 38.10 mm grouve cover of 1.2 mm thick Tk. 84.00 Tk. 81.90 Tk. 86.10 per rft.
281 57.15 mm, 15.80 mm grouve cover of 1.2 mm thick Tk. 49.35 Tk. 48.30 Tk. 50.40 per rft.
282 76.20 mm, 38.10 mm, 57.15 rnm fixed top & side of 1.2 mm
Tk. 101.85 Tk. 98.70 Tk.103.95 per rft.
thick
283 38.88 mm, 36.63 mm casement outer 1.2 mm thick Tk. 54.60 Tk. 52.50 Tk. 55.65 per rft.
j
I, 28.4 47.62 mm, 28.57 mm, 40.82 mm casement shutter of 1.9 mm
thick Tk. 95.55 Tk. 92.40 Tk. 97.65 per rft.
286 .57.15 mm, 1S.80 mm grouve cover of 1.2 mm thick Tk. 49.35 Tk. 49.35 Tk. 50.40 per rft.
i 287 17.40 mm, 31.78 mm bottom cover of 1.2 mm thick Tk. 33.60 Tk. 32.55 Tk. 34.65 per rft.
288· 76.20 mm, 38.10 mm fixed bottom cover of 1.2 mm thick Tk. 84.00 Tk. 81.90 Tk. 86.10 perrft.
I 289 57.15 mm, 38.10 mm top & side of 1.2 mm thick . Tk. 101.85 Tk . 98.70 Tk.103.95 per rft.
290 76.00 mm, 38.10 mm wall frame of 1.2 mm thick Tk. 75.60 Tk. 73.50 Tk. 77.70 perrft.
291 55.02 mm, 37.39 mm louver Z-section of 1.2 mm thick Tk. 31.50 Tk. 30.45 Tk. 32.55 perrft.
r-29_21-3_9._67_m_m_,_1_s._06_m_m_l_ow_e_r_u-_se_c_tio_n_Of_1_.2._m_m_t_hic_k____+I_T_k.____ 36_.7_5~_T~k.__-3-5.7-0~--Tk_._3_7_.B_o-+__
per~
293 95.00 mm, 38.00 mm outer bottom of 1.2 mm thick I Tk. 103.95. Tk. 100.80 Tk. 106.05 perrft. I
I i
j I
294 95.00 mm) 28.50 mm outer top of 1.2 mm thick ! Tk. 10(. :.1 I Tk. 103.95 Tk. 109.20 per rft.
.i i
I,--_29_S-!.I_9_s._00_m_m_,_1_9.5_0_m_m_o_ut_er_S_ide_o_f_1._2__m_m__th_ic__k _____ .__~___8_1-_.9_0-L1_T_k_.___7_9_.80----'--__T_k._8_4_.0_0---,-_p_er_rft_.-,
PWD SoR 2014 for Civil Works 20
- i
Sl Items Rate Unit II
I I
i I
296 42.2 mm, 13.2 mm net section of 1.2 mm thickness ' Tk. 53.55 ! Tk. 51.45 Tk. 54.60 per rft. I
i
i
297 1" x 1 square pipe
II Tk. 50.40 Tk. 48.30 Tk. 51.45 per lit. I
j
I
298 7.14 mm span drel of 1.2 mm thick (0.70 kg/m) Tk. 70.35 Tk. 68.25 Tk. 72.45 per rft. I
j
I
299 Mosquito net (fiber net) (per sft.) Tk. 15.75 Tk. 15.75 Tk. 16.80 per rft. i
j
300 T-section (main T) for false ceiling Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft. I
301 T-section (cross T) for false ceilihg Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
I
302 L-section for wall and ceiling Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
I
303 Aluminium curtain rail in/c hard-wares and fittings Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft.
I
304 44 mm, 44 mm, 1.20 box Tk. 72.45 Tk. 70.35 Tk. 74.55 per rft. I
I
305 25 mm, 25 mm, 1.20 angle Tk. 22.05 Tk. 21.00 Tk. 23.10 per rft. I
!
306 25 mm, 25 mm, 1.20 fitting angle Tk. 38.85 Tk. 37.80 Tk. 39.90 per rft.
!
i
307 Alluminium composite Panel Tk. 238.73 Tk. 236.25 Tk.242.55 I per rh.
I
I
308 Curtain wall sub mullium (100mm X 50 mm X 2.00 mm) Tk. 324.45 Tk. 315.00 Tk.329.70 'perrft. I!
309 Curtain wall sub mullium (50mm X50 mOl X1.50 mm) Tk. 206.85 Tk. 200.55 Tk.211.05 ,per rft. J
310 Casement outer frame (29mm X20 mm X1.20 mm) Tk. 33.60 Tk. 34.65 Tk. 34.65 per rft. I
I
i
I
311 Casement outer section (52mm X22 mm X40mm X 1.5 mm) Tk. 155.40 Tk. 152.25 Tk.158.55 per rft. I
i
I
312 Aluminium angle (50mm X 50 mm X 6mm) Tk. 180.60 Tk. 178.50 Tk.183.75 per rft. I
I
i
313 Aluminium cover (50mm X 6 mm X 1.Smm) Tk. 64.54 Tk. 61.95 Tk. 66.15 per rft. J
314 50mm X 6 mm X 1.5mm angle for casement shutter Tk. 55.26 Tk. 57.75 Tk. 56.70 per rft. ,
!
I i
315 38mm x 38mm Aluminium frame (Wall box) of 1.5 mm Tk. 41.30
'T'I.
42.00 Tk. 42.00 per rft.
I
38mm x 12mm and 1.5 mm thick Aluminium frame of Netting
316 Tk. 51.80 Tk. 50.40 Tk. 53.55 per rft.
shutter top, bottom &side
317 20 mm Aluminium pipe I Tk. 88.20 Tk. 86.10 Tk. 90.30 perrft.
I
PWD SoR2014 for Civil Works 21
353 Rod tilt I Hexagon Aluminium Rod Tk. 8.05 Per rft.
354 End cap set I End closure set Tk. 61.20 Per set
-... -_.-,/-_.. __ _-
.•. 358 Plastic Washer I Fabric upper dip Tk. 2.20 each
364 Glass fiber Fabrics (special quarrty, foreign made) Tk. 88.62 Per sft.
369 Aluminium Strips (special quality, foreign made) Tk. 74.42 Per rft.
370 Rod till / Hexagon Aluminium Rod Tk. 5.43 Per rft.
PWD SoR 2014 for Civil Works 25
463 Rowl plug (10 Nos. per pack) Tk. 18.43 . Per pack
"--*- :-.,._-----
464 1 Aluminium main Tee .
II Tk. 26.05 Per rft.
II. Consumable
495 5/8" x 3" long nut bolt in/c washer Tk. 95.61 each
496 Valve Pit (Titas Gas T&O Co. Ltd. design & plan.) (for 2" dia above) Tk. 15,154.70 each
497 M.S. sheet cover supplied by Titas Gas T & 0 Co. Ltd.{for 2" dia abov~) Tk. 13A92.37 each
499 50 mm NO dia ball valve class 150 R.F. Tk. 7,000.40 each
506 3/4" dia G.I. pipe (NTL or eqv.) Tk. 60.80 Per rft.
507 1/2" dia G.I. pipe (NTL or eqv.) Tk. 51.25 Per rft.
-"'?""'---
. 513
514
70 mm non load bearing concrete hollow block
Transportation 70 mm block
Tk.
Tk.
21.23
3.18
':"'\'~~::~";Y"·'·..'••
each
each
516 90 mm non load bearing concrete hollow block Tk. 24.00 each
518 140 mm non load bearing concrete hollow block Tk. 33.46 each.
520 140 mm load bearing concrete hollow block Tk. 48.75 each
521 190 mm load bearing concrete hollow hlock Tk. 59.61 each
540 Transportation Solid block (215 x 100 x 65) mm Tk. 1.64 each
541 200 x 92 x 37.5 mm grey solid cladding block Tk. 12.19 each
543 200 x 92 x 37.5 mm colored solid cladding block Tk. 8.96 each
548 418 x 330 x 17 mm red color roof tiles Tk. 41.07 each
551 418 x 330 x 17 mrn oriental color ropf tiles Tk. 37.01 each
552 418 x 330 x 17 mm antique red color roof tiles Tk. 42.65 each
-----~.--
553 418 x 330 x 17 mrri green color roof tiles Tk. 46.40 each
121.66 each -J
554 600 x 300 x 100 mm kerb stone Tk. I
PWD SoR 2014 for Civil Works 30
556 100 mm non-load bearing concrete hollow block Tk. 26.68 each
564 418 x 330 x 17 mm brown color roof tiles Tk. 43.00 each
565 418 x 330 x 17 mm Navy blue roof tiles Tk. 45.97 each
566 418 x 330 x 17 mm Mahogany color roof tiles Tk. 43.08 each
567 418 x 330 x 17 mm Rust Gold color roof tiles . Tk. 42797 each
568 All type Concrete Ridge: red color Tk. 130.95 each
I. Misc. items:
571 Water sealed heavy type 18" dia C.I. M.H. cover having locking arrangement Tk. 1,026.84 each
593 32 mm dia plastic pipe for low-down connection Tk. 79.77 each
White Combicloset, Size (mm) 700 x 410 x 795. (BISF item No. 115A1415A or Tk. 3,622.50
594 each
equivalent)
605 White long pan, Size approx.585x445x290, 12.Skg Tk. 484.15 each
,
SL Items Rate Unit j
608 White/colored foot-rest, Size (mm) 260 x 227 x 25. 280x140x30,1.5kg Tk. 80.50 Per pair
J I
609 BISF White W-basin, 600x465x225, 14kg 580 x 445 x 235. Tk. 1,147.00 each I
I
612 White W-basin in/c pedastal, Size (mm) 656x51 Ox845 , 26kg 570 x 420 x 190. Tk. 4,000.00 each
622
623
Colored Pedestal: -do-
Tk.
801.00
842.00
each.
each
J I
624 BISF White Bowl Urinal, Size (mm) 485 x 360 x 290, 9kg . Tk. 943.00 each
627 White Flat/Squat. Urinal, Size (mm) approx510 x380x 85 Tk. 869.00 each
J
628 Colored Flat/Squatting Bowl Urinal: -do- Tk. 914.00 each I
629 Special colored Flat/Squatting Bowl Urinal: -do- Tk. 959.00 each
630 White porcelain Sink, Size (mm) 635x 480x195, 19.5kg Tk. 2,024.00 each I
I
632 Stainless steel, Single Bowl Sink: Singapore/M'Asia, Size (mm) 450 x 1050 Tk. 2,596.49 each I
J
iI
633 Stainless stee"!, double Bowl Sink: Singapore/M'Asia, Tk. 4,906.22 each
'-
I
i
634 450 x 600 x. 5mm mirror Tk. 492.00 each
J
635 450 x 350 x 4mm mirror Tk. 336.00 each ij
PWD SoR 2014 for Civil Works 33
639
Medium quality CP iron frame with brackets for 600 x 125 x 5 mm size Glass
Shen.
Tk.
305.00
133.00
each
each
J I
640 Super Quality 600 x 20 mm dia size CP Towel Rail. Tk. 417.44 each I
I
643 . Special Porcelain Toilet Paper Holder: -do- Tk. 155.00 each
I
644 Standard size Stainless Steel Toilet Paper Holder with Cover Tk. 270.96 each
I
645 Standard size CP Toilet Paper Holder with Plastic Holder rod . Tk. 216.02 each
649 Plastic low down complete set in/c internal and external fittings Tk. 1,066.59 per set i
I :
650 Internal and external fittings for plastic low down Tk. 568.91 per set
II t
651 CP Soap tray Tk. 124.00 Each I
II i
662 150 mm dia HCI bend/offset Tk. 1,013.81 each
1
J
663 150 mm dia HCI Tee/T-YIY (50 x 50 mm) Tk. 1,424.70 each
666 HCI150 x 150 or 150 x 100 mm or T-Yor Y-Cleanout Tk. 813.74 each
678 19mm x12 mm dia uPVC Rd. Tee Tk. 28.38 each i
r---~----------------------------------------~----------+------~ I
679 19mm x12 mm dia uPVC Rd. Elbow Tk. 30.64 each j
I
680 25 mm dia uPVC pipe Tk. 28.08 Per rft. I
J
681 25 mm x 19 mm dia Rd. Tee Tk. 49.52 each
I
682 32 mm dia uPVC pipe Tk. 34.90 Per rft.
I
683 32 mm dia uPVC Tee 75.47 each
\
684 32 mm dia uPVC Socket Tk. 60.13 each
I
685 32 mm dia Elbow Tk. 59.65 each
i
686 32 mm plain bend 900 I Tk. 62.29 I each
' - -_ _ _ _ _ _---l
691 50 mm dia uPVC Pipe: 20 rft (6m) long Tk. 896.75 Per pc.
693 50 mm dia uPVC Tee/T-YIY (50 x50 mm) Tk. 209.24 each
710 100 mm dia uPVC Pipe: 20 rft (6m) long Tk. 2,083.78 Per pc.
-
711 100 mm dia uPVC bend/offset Tk. 292.00 each
712 100 mm dia uPVC Tee/T-Y/Y (SOx 50 mm) Tk. 457.94 each
Sl Items
i Rate
i
Unit
I
I
!
717 110 mm dia round Grating Tk. 319.79 each
J
I
718 110 mm dia uPVC vent Cowl Tk. 108.29 each i
719 150 mm dia uPVC Pipe: 20 rft (6m) long Tk. 2,719.83 Per pc.
725 280 mm dia uPVC pipe for under-ground Tk. . 525.55 Per rft.
J
Ii
726 315 mm dia uPVC pipe for under-ground Tk. 755.23 Per rft.
I
(b) CPVC j
I
I
727 12 mm dia CPVC pipe Tk. 33.91 Per rft.
----
SL items T Rate '~ilit
I
758 19 mm dia ASS pipe Tk. 63.77 Per rft.
- !
759 19 mm dia ASS plain Tee Tk. 82.36 each
I I
760 19 mm dia ASS Plain Elbow Tk. 64.30 each
1
761 19 mm dia ASS Plain Socket Tk. 41.76 each I
i 762 19mm x 12 mm dia ASS Rd. Tee Tk. 24.30- each I
!
Tk. 139.72 each I
763 19mm x 12 mm dia ASS Rd. Elbow I
I
764 25 mm dia ASS pipe Tk. 84.21 Perrft.
I
i
SL Items Rate Unit i
I I
-!
!
i :
771 37 mm dia ASS Tee Tk. 364.54 each
I I ;
i I
772 37 mm dia ASS Socket Tk. 180.70 each I
J
i
773 37 mm dia ASS Elbow Tk. 297.92 each j
j
i
~
839 100 mm dia reducer Tk. 336.88 I each
841 62 mm dia stainless steel (2 mm thick) pipe Tk. 304.54 Per rft.
842 50 mm dia stainless steel (2 mm thick) pipe Tk. 250.85 Per rft.
843 40 mm dfa stainless steel (2 mm thick) pipe Tk. 198.68 Per rft.
844 25 mm dia stainless steel (2 mm thick) pipe Tk. 136.19 Per rft.
845 .20 mm dia stainless steel (2 mm thick) pipe Tk. 93.91 Per rft.
846 12 mm dia stainless steel (2 mm thick) pipe Tk. 83.65 Per rft.
I
847 70.79 Per rft.
6 mm dia stainless steel (1.5 mmthick) pipe Tk.
I
!
848 25 mm x 25 mm S5 square solid bar Tk. 105.72 Per rft.
852 50 mm x 25 mm x 2 mm SS box: ..
.,..~,
256.57 Per rft . I
853 S5 Welding rod Tk. 301.54 . Per Ib
PWD SoR 2014 for Civil Works 41
858 150 mm dia ReG pipe (stone-chips. 40 mm thickness. 6'-0" long) Tk. 1,017.00 each (6'-0")
I
859 225 mm dia ReG pipe: -do- Tk. 1,575.00. each (6'-0")
I
860 300 mm dia ReG pipe (stone-chips, 50 mm thickness. 6'-on long) Tk. 2,743.00 each (6'-0")
I
861 375 mm dia ReG pipe (stone-chips. 50 mm thickness. 6'-0" long) Tk. 3,580.00 each (6'·0") I
862 900 mm dia ReG pipe (stone-chips. 100mm thickness. 6'.0" long) Tk. 13,190.00 each (6'.0")
I
SL Items Rate Unit
VIII. Float-Valve
I
899 12 mm dia Float-Valve Tk. 234.22 each j
900 20 mm dia Float-Valve Tk. 317.10 each j
901 25 mm dia Float-Valve
Tk.
348.93
618.07
each
each
J
i
906 HCI150 x 150 or 150 x 100 mm T-Yor Ycleanout Tk. 1,139.22 each
910 100 mm nyn or 'T-yn plastic clean out Tk. 426.58 each
X. Faucets
927 CP shower mixture in/c shower head &faucet Tk. 3,866.37 each
930 12 mm ordinary type (brass) for surface mount CP stop cock Tk. 229.54 each
940 Special concealed type heavy stop cock Tk. 766.53 each
941 12 mm CP medium qu~lity surface & heavy type angle stop cock Tk. 512.50 . each
949 1000 liter food-grade Plastic over-head water-tank Tk. 9,800.00 each
950 1500 liter food~grade Plastic over-head water-tank Tk. 14,700.00 each
QS1 2000 liter food-grade Plastic over-head water-tank Tk. 19,600.00 each
952 150 liter capacity plastic mini tank (loft tank) Tk. 1,950.00 each
953 300 liter capacity plastic mini tank (loft tank) Tk. 3,690.00 each
954 500 liter capacity plastic mini tank (loft tank) Tk. 5,000.00 each
i
955 500 liter capacity stainless stee~ water tank Tk. 7,640.93 each
I
956 1000 liter food-grade stainless steel water tank Tk. 14,036.63 each !
!
PWD SoR 2014 for Civil Works 45
958 4000 liter food-grade stainless steel water tank Tk. 49,191.06 each
..
959 6000 liter food-grade stainless steel water tank Tk. 53,481.79 each
960 400 Gallon capacity Ferro-cement water tank Tk. 6,320.90 each
961 450 mm long metal cover connection pipe Tk. 266.46 each
962 600 mm long metal cover connection pipe Tk. 307.52 each
I
1
963 1/2·or 3/4" dia ball cock for water tank Tk. 231.50 each
964 3/48 dia overflow pipe with jam-nut for plastic water tank Tk. 122.37 eaGh
965 12 mm dia &450 mm long plastic flexible connection pipe Tk~ ~ 48.74 each
--
966 12 mm dia &600 mm long plasticfiexible connection pipe Tk. 57.62 each
967 11 titer capacity/50 GPO Reverse Osmosis water Purifier Tk. 16,998.58 each
968 10 liter capacity/75 GPO Reverse Osmosis water Purifier(without meter) Tk. 20,063.85 each
i
969 10 liter ~pacity/75 GPO Reverse Osmosis water Purifier(with meter) Tk. 21,205.04 each
I
COld~
I
i
I 17li1er capacity/tOO GPO Reverse Osmosis water Purifier. (hoi. Tk. 63,809.24 each
i
I
970 i
I
I options) . . I
I
--l
I
971 400 gal capacity ferro-cerrient water tank in/c installation Tk. 7,251.45 each I
~
974 Possible CosURoyalty of lawn grass Tk. 35.00 Per % sft.
976 16'-0" long muli bamboo (For split) Tk. 75.00 each
977 8
25'-0 long flluli bamboo (Full size) Tk. 130.00 each
993 Steel funna, 18" size wirth wooden handle Tk. 200.00 . each
998 22 BWG G.!. water can (2.S gallon) Tk. . 250.00 ea~h
1000 %" dia plastic hose pipe Tk. 15.00 per rft.
1001 3.75 h.p. 22" blade 4 stroke, finger trip Lawn Mower Machine: YARDMAN No. Tk. 40,000.00 each
060A
1002 16" blade Hand Lawn Mower, Model No. 1403 -16 (USA) Tk. 10,500.00 each
,."i. ..' '":~:;;:,,£,~;~>,/,:
,::~ :i?Y>;,.'-
I . ••.. ,.·..:.:.i •.·S;· ...\'
I. For Test boring &design
1003 Mobilization of equipment for drilling 38 mm dia test and observation well Tk. 5,856.91 L.S.
1004 Boring by using 100 mm dia cutter (0 mto 50 m) Tk. 128.00 meter
1005 Best quality heavy type hand type pump NO.6 Tk. 2,182.00 each
1006 2.91. mm wall thick 38 mm dia G.!. pipe Tk. 486.41 meter
1007 38mm dia water grade PVC pipe (D·C!ass or eqv.) in/c carnage Tk. 95.65 meter
1008 36 mm dia water grade PVC Strainer (D·Class or eqv.) in/c carriage Tk. 111.80 Meter
.~/
PWD 5aR 2014 for Civil Works 47
1011 Complete development of the tube-well (test boring) up to 200 m depth. Tk. 5,150.37 L.S.
101.5 Maintaining and filling and sealing test bore Tk. 2,961.76 Each bore
1016 Mobilization of drilling rig for shrouded production wells of depth up to 100 m Tk. 29,392.65 L.S.
i
SL Items Rate Unit
Complete development of the tube-well UP. to 200 mdepth (50 x 150 mm tube-
1042 well). Tk. 18,573.48 LS.
J
Complete development of the tube-well up·to 200 mdepth. (75 x 150 mm
1043 tube-well) Tk. 23,637.15 L.S.
j
i
i
1047 Hire charge of pump inlc spare and maintenance Tk. 230.24 Hour i
I
l.S. Ii
!
. ,
1049 150 mm dia and 4 mm thick M.S. pipe Tk. 1,952.98 meter i
i
1050 200 mm dia and 6 mm thick M.S. pipe welded Tk. 2,900.27 meter I
I
1051 200 mm dia and 6 mm thick M.S. pipe seamless Tk. 3,200.93 .meter 1
!
1052 4 mm thick 200 mm dia plate Tk. 987.20 each l'
I
J
1053 5 mm thick 250 mm dia plate Tk. . 1,158.86 each j
1056 150 mm dia 4.85 mm thick G.I. pi;'.3 Tk. 2,462.63 meter
!
I
I
1057 200 mm dia 6 mm thict·. ~.I. pipe Tk. 5,770.75 meter I
i
1058 150 mm dia stainless steel strainer of continuous slot Tk. 12,117.41 meter
!
1059 '150 mm dia 2.5 m'm thick stainless steel bridge type strainer Tk. 8,644.03 meter i!
1060 200 mm dia stainless steel strainer of cf)ntinuous slot Tk. 13,856.05 meter !
\
1061 200 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 8,831.97 meter
I
1062 75 mm dia 2.5 mm thick stainless steel bridge type strainer I Tk. 5,618.07 meter
j
PWD SoR 2014 (or Civil Works _ 49
1063 100 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 5,546.52 meter
1064 50 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 4,549.91 meter
1065 75 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 6,179.02 meter
1066 150 mm x 300 mm dia 6 mm thick M.S. reducer Tk. 8,688.87 each I
1067 200 x 300 mm dia M.S. reducer Tk. 10,823.91 each
1071 (i) 300 mm dia 6 mm thick M.S. Housing pipe welded Tk. 5,037.14 meter
1072 (ii) 300 mm dia 6 mm thick M.S. Housing pipe seamless Tk. 8,178.48 meter I
I
1073 '(iii) 400 mm dia 6 mm thick M.S. Housing pipe welded Tk. 9,017.14 meter
I!
1074 (iv) 400 mm dia 6 mm thick M.S. Housing pipe seamless Tk: 11,042.23 meter
I
1075 150 mm dia 6 mm thick M.S. Housing pipe welded Tk. 2,549.97 meter I
!
1076 150 mm dia 6 mm thick M;S.· Housing pipe seamless Tk. 2,639.54 meter I
I
1077 350 mm dia 6 mm thick M.S. Cap Tk. 1,400.80 each II
1078 40 mm dia Ro" grade pipe Tk. 32.57 rft.
1081 EPII RFL (medium) brand NO.6 Pump with necessary fittings etc. Tk. 2,277.00 each
C!
PWD SoR 2014 for Civil Works 50
III. Testing of water in/c arsenic, collected from the test bore in SUET
Laboratory
1105 Sieve analysis for sand from different layer Tk. 1,123.00 Per test
,>..,.,;';~ ,:::;;·;:f:·,,;t
'.;;->"\<> :.:': ·s .....
:.. : .... c." !.. i/·': ..>·.:·,,:~>2{·'·.::
I. Operational cost
1106 Truck fare within 20 km in/c loading & un-loading Tk. 1,000.00 Per trip
1107 Temporary camp at site for soil investigation work Tk. 1,053.00 Per site
1108 Field Engineer in/c site allowances: 1-3yrs Exp, Membersip with IEB Tk. 1,438.00 Per day
1109 Foundation Engineer: 5-10yrs exp, Membership with IEB Tk. 2,156.00 Per day
1111 Rig operators inlc site allowances Tk~ 603.00 Per day
1112 Helper to rig operator/c site allowances Tk. 375.00 . Per day
1113 Unskilled labour in/c site allowances Tk. 313.00 Per day
1124 Hydrometer, sieve analysis & sp. gr.,& Classification according to ASTM Tk. 875.00 Per test
I
1125 Linear shrinkage Tk. 500.00 Per test I
1126 Shrinkage limit Tk. SOO.OO Per test
I
I
Tk. 250.00 Per test
--J
i
I
i 128 I Plastic limit Tk. 250.00 Per test
I
I 1- -------l
1140 Consolidated drain test (direct shear test) Tk. 1,000.00 Pertest
I
1141 Consolidated drained tn-axial test Tk. 1,250.00 Pertest
1142 Consolidated quick test (direct shear test) Tk. 875.00 Pertest
I
PWD SoR 2014 for Civil Works 52
1143 Consolidated un-drained tn-axial test with pore pressure Tk. 2,875.00 Per test
1144 Consolidated un-drained tn-axial test without pore pressure Tk. 875.00 Per test
1146 Unconsolidated quick test (direct shear test) Tk. 1,000.00 Pertest
1147 Unconsolidated un-drained bi-axial test (without pore pressure) Tk. 1,000.00 Pertest
1148 Field density in/c field visit (for non-cohesive soil) Tk. 1,875.00 Pertest
1149 Field Vanshear test in cohesive soil (ASTM 0-2573-72, 1978) Tk. 1,750.00 Pertest
1151 One dimensional swelling/settlement potential of co-hesive soil Tk. 1,875.00 Pertest I
Non-repetitive static plate load test of soil (ASTM 8-1196-64, reaapproved in Tk. 1,750.00 Pertest
1152
1977)
1153 Visual Inspection &Classification of soil for engineering purposes Tk. 94.00 Pertest
1186 6" long brass tower &socket bolt Tk. 241.00 each
"-
\ 1197 1.5 mm thick corrugated fiber glass Tk. 77.00 Per sft.
1198 1.5 mm thick fiber glass sheet ridging Tk. 117.00 Per rft.
1202 Top and bottom clamping device . Tk. 1,014.00 Per set
1218 Empty gunny bags! Polymer bag to fill sand for load test Tk. 9.00 each
1220 Copper sheet for expansion joint Tk. 198.00 Per sft.
II
I 1236 Heavy dutY gate locking arrangement Tk. 229.00 each
I
1239 China made spring for rolling shutter Tk. 24~00 Per rft.
I
1240 Spring box for rolling shutter Tk. 103.00 each
J
1241 1/2 dia nut-bolt Tk. 9.00 each I
I
1280 Engineer, min graduate in relevant field Tk. 1,200.00 per day
1281 Diploma Engineer, min 5yrs Exp Tk. 1,200.00 per day
1284 Royalityof Dredge material in the water body Tk. 650.00 per thousand eft
PDA Test: StnKing hammer, guide, trip gear etc in/c carriage, saftey .&
1'285 insurance . Tk. 20,000.00 each per day
I
1286 PDA TEST: lifting device including carraige, saftey & insurance Tk. 20,000.00 each per day
I
1287
PDA Test: Data acquisition unit, sensors etc including carriage, saftey &
insurance . Tk. 50,000;00 each per day !I
1288 Arc welding at workshop 1factory Tk. 20.00 per rft
1289 Cutting by oxy-ace..10f 1/2" M.S plate, top &batt plate Tk. 15.00 tk/rft
I
1290 1/2 th MS Plate Grinding to V bevel top & bott Tk. 100.00 tklrft
1291 1" dia Hole in 1/2' M.S plate Tk. 20.00 pInos
Cutting by shearing granding and hole for steel jacket,.1/4n plate on 2U x ( top
. 1292
& bott) - Cor Uform
Tk. 10.00 tklrft
I
1293 1/4 th MS Plate Grinding to V bevel on faces of Ulegs for top & bott Tk. 60.00 tk/rft
.~
1294 Charge to bend 1/4"th MS Plates Tk, 10.00 tk/rft I
1295 2" dia Hole in 1/4" M.S plate Tk. 15.00 pInos
1296 1.51 G.lf MS pipe for dowel bar Tk. 160.00 tk/rft
1298 Data logging Engineer at Hydraulic pile driver Tk. 1,500.00 per day
1299 Chief Mechanic, at Hydraulic pile driver Tk. 1,200.00 per day
1300 Helper to mechanic, at Hydraulic pile driver Tk. 388.00 per day
1302 Crane Operator, at Hydraulic pile driver Tk. 1,000.00 . per day
!.
1303 Asst Crane O~rator, at Hydraulic pile driver Tk. 732.00 per day
J
PWO SoR 2014 for Civil Works 58
I
I
SL Items Rate Unit
, I
1304 Machine Operator, at Hydraulic pile driver Tk. 1,000.00 per day
.~ I
1305 Asst machine operator, at Hydraulic pile driver Tk. 732.00 per day
1306 Helper to crane operator, at Hydraulic pile driver Tk. 388.00 per day
I
1307 Helper to machine operator, at Hydraulic pile driver Tk. 388.00 . per day
I
I
1308 Generator Operator, at Hydraulic pile driver. Tk. 732.00 per day
I!
1309 Surveyer to pile layout, at Hydraulic pile driver Tk. 1,000.00 per day I
!i
1310 Helper to sUrV~yer, at Hydraulic pile driver Tk. 732.00 per day
i
I
I
1311 Skilled Labor, at Hydraulic pile driver Tk. 303.00 per day
i!
I
I
I
1312 ordinary labor, at Hydraulic pile driver . Tk. 245.00 per day
!
Compilation of driving Report, Pile Capacity log & submission to PE"on signing
1313 it on Hydraulic pile driver .
Tk. 10,000.00 per day
I
1314 Each additional copy, at Hydraulic pile driver Tk. 500.00 _per day
I
PIT: Mobilization,Demobilization, Accomodation +12pile PIT 20000
per 100km within
Dhaka i
r
j
I
1315 beyond 100km from Dhaka 25 perkm I
I per pile after:j~t iI
;
1320
Float I annealed Glass thickness :2.5mm
41
sft
sft
J I
1320 Laboratory Charges for Testing Materials: Please find the Division 32 A and 32 B.
~,j;;i.:;'i'~_;;;?';';'?'oL";;' ;:0. '<" .,.>;/;.,... ;}>;, .....• :•.
'i,v·;·;,,'}·:·r<>::
). '<.'.<:,::r:. ••.•~ ;;\}':''\·'i::<;\~:;':>:·:.
Carriage of materials except bricks and bats by motor trucks bullock carts or i
1 any other means, in/c. loading, unloading at both ends and stacking properly I
at site as per direction of the Engineer.
(d) For each additional km beyond 5.0 kilometer and up to 30.0 kilometer Tk. 16.00 Per M. ton
(e) For each additional km beyond 30.0 kilometer and up to BO.O kilometer Tk. 11.00 Per M. ton
2. Weighing at both ends for items of steel materials only Tk. 94.00 Per M. ton
Carriage of bricks or bats by motor truck, bullock carts or any other means
3. in/c. loading, unloading at both ends and stacking properly at site as per
direction of the Engineer.
(d) For each additional km beyond 5.0 kilometer and up to 30.0 kilometer Tk. 23.00 Per %0 Nos.
(e) For each additional km bejond ~;,;.O kilometer and up to BO.O kilometer Tk. 16.00 Per %0 Nos.
01.1 Erection and maintenance of site office and removal the same after completion
of work in accordance with the conditions of contract. In addition to the office
required for his own use, the Contractor shall provide and maintain furnished field
office for the use of the Engineer and his staff. The field office is to have a concrete
floor, adequate foundation, brick walls, false ceiling of hard board with seasoned
Garjan wood frame and painted, and all windows are to be glazed and provided with
steel grill. Outside and inside wall surface are to be painted on plaster acceptable to
the Engineer. The field office shall be maintained in a secure and watertight condition
by the Contractor until th~ completion of the contract and shall be provided with
electricity, running water and sewerage. All doors shall be fitted with approved locks
aM windows shall be provided with screen/blinds. Before construction the Contractor
shall submit plans and drawings showing proposed details and location for the field
office, including foundations, access roads, shades, layout of electrical and water
supply and hard standings thereto for the approval of the engineer. The Engineer
may require revision of the plans prior to giving approval for construction. The
Contractor shall also submit details proposed furniture, fittings and other items of
equipment and plant to the engineer for approvaL These items shall be of the
standard quality suitable for site. The office, complete with furnishings, fittings,
access roads and hard standings shalf be ready for occupation by the Engineer
within 28 days of the date when the Contractor first occupies the site. The Contractor
will provide day and night guards and a tea boy for the field office. At the end of the
project .all materials, equipment and plant, furniture, fittings recovered from
--- -'---- dismanfiingthe office and removing access road will be the property of the
Contractor. No -interim payment shall be certified unless Engineer's office with
required facilities are constructed and accepted by the Engineer.
(This is a time related item. Proportionate payment for this item shall be· made
distributing in each bill on the basis. of percentage progress of the whole works under
contract)
01.1.1 Engineer's sHe office of minimum 15 sqm plinth area with providing furniture, first aid- Tk. 125,251.00
box, safety helmet; level/theodolite, consumables, stationeries etc.
01.1.2 Engineer's sHe office of minimum 38 sqm plinth area with providing security fencing, Tk. 389,014.00
5 Kva stand-bye generator, furntture, first aid-box, safety helmet, level! theodolite,
consumables, stationeries etc.
01.1.3 Engineer's sHe office of minimum 38 sqm plinth area with providing security fencing, Tk. 502,145.00
5 Kva stand-bye generator, IBM compatible PC with monitor, unimel (uptible power
supply (UPS), Laserjet printer (minimum 25 ppm), furrifl're, first aid-box, safety
helmet, levelltheodolite/EDM, consumables, stationeries etc.
01.1.4 Engineer's sije office of minimum 38 sqm plinth area with providing security fencing, Tk. 534,467.00
5 Kva stand-bye generator, IBM compatible PC with monitor, uninterruptible power
supply (UPS), Laserjet printer (minimum 25 ppm), photocopier, 6 cft. Freeze,
furniture, first aid-box, safety helmet, level/theodolite/EDM, consumables,
stationeries etc.
'PWD SoR 2014 for Civil Works 61
01.1.5 Engineer's site office of minimum 10 sqm plinth area with proViding furniture, first aid- Tk. 23,916.00
box, safety helmet, consumables, stationeries etc for low value simple work of short
duration (not more than six months).
01.1.6 Providing and maintenance window type 1800 BTU AC (Air-Cooler) for ;i"J·.~~.(;:n:. Tk. 52,871.00
Engineer's office and remove after completion of contract.
01.1.7 Providing and maintenance one' project profile signboards of the size not Tk. 207.00
exceeding 1 m x 2. m, to be placed at a suitable place of the site including
submission of proposals for the materials of the signboards and text layout to the
Engineer for approval which· Will be positioned as directed by the' Engineer and
removing the same on completion of the Works or as instructed by the Engineer.
01.2.1 Providing 3 sets as-built Drawings subject to Engineer's approval produced in Tk. 19,451.00
AutoCAD software in 23.38" x 16.54" (A-2 size) standard drawing paper, and
operating and maintenance manual of the equipment and plant incorporated in the
works, if any. in original by the date stated in the Particular Conditions of Contract
(PCC). If fhe Contractor does not supply the as-built drawings and operating and
maintenance manuals by the date stated in the Particular Conditions of Contract
(PCC), or they do not receive the Engineer's approval, the Engineer shall withhold
the amount stated in the PCC from the payments· due to the Contractor.
The as-built drawings must show the permanent works as actually constructed and
reflect the revision of Tender Drawings and Drawings supplied to the Contractor
during the Contract as well as revisions of. drawings supplied by the Contractor
. during the Contract.
(One set of as-built drawings shall be considered for measurement and payment)
p1.2.2 Providing additional copy of as-built drawing produced in AutoCAD software in Tk. 267.00
23.38" x16.54" (A-2)·standard drawing paper accepted by the Engineer.
01.2.3 Providing minimum ten (10) copies coloured post-card size progress photograph of Tk. 42.00
'works under contract' taken by profeSSional photographer which record the progress
of the Works.
01.2.4 Preparation & submission of implementation schedule to the Engineer for approval Tk. 29,165.00
prior ground breaking showing· the events (works) and successive sub-events of
works including all the management & control parameters like Earliest Start Time
(ESnl Earliest Finish Time (EFH. float events on critical path, resource allocation
etc. with description of general method of works, in orderly manner all in the form
network diagram prepared in computer software like MS project and presenting in
Displayable hard and soft copy minimum 3 (three) sets.
(This is a time related item. Proportionate payment for this item shall be made
distributing in each bill on the basis of percentage progress of the whole works iAnder
contract)
01.2.5 Updating tile Implementation Schedule' and submission to the Engineer at Tk. 12,371.00
intervals no longer than 28 days shOWing actual physical and financial progress
achieved, on each activity and the effect .of the progress on the timing of the
remaining work, including any changes to the sequence of the activities.
However, Engineers approval of the Programme shall not alter the Contractor's
obligations. The Contractor may revise the Programme and'submit it to the Enginee~
again at any time. A revised programme shall show the Variations and Events
related to chaJigeof contract price. Month wise documentation shall be the basis
of payments on this item
PWD SoR 2014 for Civil Works 62
\
01.2.6 Providing all necessary logistic support to frame 'monthly progress meeting' Tk. 1,802.00
\ between Contractor/Contractor's representatives and Employer / Employer's
representatives at the Engineer's office at site. Month wise documentation shall be
the basis of payments on this item
01.3 Providing layout and carry over PWD Bench-Mark (8M) at site from nearby BM Tk. 4.00
pillar, Property lines, existing ground level (EGL), formation ground level (FGL),
highest flood levels (HFL), plinth levels (PL), mean sea level (MSL), setting and
marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RL's)
including locating, establishing, protecting all public utilities within the premise of
work and finally all to be presented in black and white ..
01.4 Mobilization and cleaning site before commencing actual physical work and during Tk. 21.00
contract period and demobilization after completion of the Works under contract
accepted· by Engineer.This work shall also covers clayey cleaning and clearing,
cutting or filling, dressing the project area on and in the ground to an extent that all
the events of works of the project can be executed smoothly in a working
environment with a particular attention on safety and security in all respects, and to
stockpile the end outcome to a place for disposal agreed by the Engineer, where,
payments are to be based on ground area determined by the Engineer and be
proportionate to the percentage progress of work under contract as a whole in all
respects and approved by the Engineer.
1.5 Providing Expertised architect having relevant experience (s) more than 5years for Tk. 60,000.00
detail documentation of architectural themes, drawings, workingout shop drawings,
communication with theme architect & getting approval , specifying architectural
needs according to approved master architectural themes & plan, certifying as built
drawing for the approval etc & jobs assigned by the HOPE or his official at site
(max man month not greater than 1/4th of Project duration & payment for the item
. ---- ------ subject to submission of CV & approved by approving authority) .~~~
1.6 Providing Experlised'Engneer having relevant experienCe(s) more than 10years, for Tk. 100,000.00
the project documentation, progress study & adjustment, preparation of project
Material schedule and Testing schdule for approval etc. & jobs assigned by the
HOPE or his official, at site (max man month not greater than 1/4th of Project
duration & payment for the item subject to submission of CV & approved by
approving authority)
1.7 Pick - up (double Cab) for transport of Test samples, work samples & emmergency Tk. 65,000.00
services etc. in/cfuel etc. (total usage not more than 1/6th of project duration.)
02.1 Earth work in excavation- in all kinds of soil for foundation trenches including.
layout, providing center lines, local bench-mark pillars, leveling, ramming and ·.·;:·'.':>r;i:,,'J':>:.i;>'
preparing the base, fixing· bamboo spikes and marking layout with chalk powder,
providing necessary tools and plants, protecting and maintaining the trench dry etc.,
stacking, cleaning the excavated earth at a safe distance out of the area enclosed by
the layout etc. all complete and accepted by the Engineer, subject to submit method
statement of carrying out excavation work to the Engineer for approval. However,
Engineer's approval shall not relieve the contractor of his responsibilities and ~:.:JS\;.{:~S;;<':i;:':.'\:<
obligations under the contract.
02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Tk. 11.00
Engineer. [plinth area of the structure shall b~ considered for measurement]
02.1.2 Earthwork in excavation in foundation trenches up to 1.5 mdepth and maximum 10 Tk. 67.00
mlead: in soft clayey soil/loose sand / silt
02~1.3 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 Tk. 96.00
mlead: in medium stiff clayey soil.
02.1.4 Earthwork in excavation in foundation trenches up to 1.5 mdepth and maximum 10 .~i{{icumi);:;;;·~.'). Tk. 144.00
mlead: in very stiff (hard) clayey soill rubbish etc.
02.1.5 Earthwork in excavation in foundation trenches up to 1.5 mdepth and maximum 10 .;;i?&:cOml:(:;i·; Tk. 166.00
mlead: in very soft I saturated I organic clayey soil I soil of semi-liquid state.
02.1.6 Extra rate for each additional 0.5 meter depth exceeding 1.5 meter. Tk. 16.00
02.1.7 Extra rate for each 1 madditionai lead beyond 10m. 2.12
02.2 Bailing out trapped water caused by inundation due to sepage or rain, by a Tk. 333.00
pump of aprox. 25m3/h from foundation trenches, where correct
documentation on rain fall, sepage rate, volume of inandation shall strictly be
made.
02.3 Supplying of straight and strong borrak bamboo posts of having minimum 75 mm Tk. 75.00
diameter aHhrough and driving the same vertically in the ground up to required depth
by any means shaping the top of the post, all complete and accepted by the
Engineer.
02.4 Supplying wooden ballah having an average diameter not less than 150 mm 714.00
(without barks) at one third distance from larger end with a minimum end diameter of
100 mm for retaining purpose and driving to a depth as per design and drawing by . .,..,.......,.' . . . ,.:.,. . . ~:::.
any method including all arrangement for staging, hOisting, carrying etc. complete
and accepted by the Engineer.
PWD SoR 2014 for Civil Works 64
02.5 . Palisading work by supplying bitumen drum sheet walling tied with 20 BWG G.I. Tk. 596.00
wire fixing the same with already driven borrak bamboo posts with' half split borrak
bamboo runners @450mm clc horizontally with iron nails, G.I wireete. all complete
and accepted by the Engineer. (Rate is excluding the cost of bamboo post).
02.6 Supplying and fitting-fixing horizontal bracing in Palisading with % split wooden· Tk. 269.00
ballah having an average diameter not less than 150 mm with a minimum end
diameter of 100 mm @450 mm including supply of iron nails, gazals etc. complete
approved and accepted by the Engineer.
02.7.1 Shore protection work during excavation in foundation trenches up to 1.5 m depth, : Tk. 678.00
to protect loss due to damage of property by Palisading accepted by the Engineer.
[the rate is including cost of vertical post]
02.7.2 Shore protection work during excavation in foundation trenches to protect loss due Tk. 1,217.00
to damage of property by Palisading beyond 1.5 m depth accepted by the
Engineer [the rate is including cost of vertical post]
02.8 Supply . and laying 2 mm thick Geo-textile of approved quality and Tk. 130.00
origin/manufacturer as per manufacturer's instructions approved and accepted by the
Engineer; Before commencing lying of Geo-textile, .the Contractor must submit the
method statement for carrying out this work including ~ample with evidence of origin
and compliance certificate from independent testing laboratory for approval.
02.9 Removing sludge or semi-liquid clay/substances etc not suitable for pumping out Tk. 678.00
or carrying by head load from the bottom of any marshy land, lake, ditch, pond by
mixing fine local sand of F.M. 0.8 or less to a proportion such that it can be carried to .
I
an intermediate point of disposal and cutting the same including stacking and
.----------
spreading properly on a suitable place to dry in the sun for a certain days and
dispose the dried sludge or clay to a safe distance etc. complete and accepted by
the Engineer subject to submit method statement to the Engineer for carrying out the
works including ultimate disposal of the sludge under this item for approval. However
Engineer's approval shall not relieve the Contractor of hi~ responsibilities and
obligations under the contract.
02.10.1 Sand filling in foundation trenches and plinth with sand having F.M. 0.5 to 0.8 in Tk. 602.00
150mm layers including leveling, watering and compaction to achieve minimum dry
density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the design office only etc. all
complete and accepted by the Engineer.
02.10.2 Sand fUling in foundation trenches and plinth with coarse sand having min. F.M. 1.2 Tk. . 1,043.00
in 150mm in layers including leveling, watering and compaction to achieve minimum
dry density of 90% with optimum moisture content (Modified proctor test) by ramming
each layer up to finished level as per design supplied by the. design office only etc. all
complete and accepted by the Engineer.
02.10.3 Sand filling in foundation trenches and plinth with coarse sand having min. F.M. 2.2 Tk. 1,760.00
in 150mm layers including leveling, watering and compaction to achieve minimum JJL.):~;;'i'>(.i'i:·
dry density of 90% with optimum moisture content (Modified proctor test} by ramming .... '.,>:.• ::,.,.: ....:............:.:.
each layer up to finished level as per design supplied by the design office only etc. all '.....c;:.;.;,'.' •...•,.,: ........... .
complete and accepted by the Engineer.
PWD SoR 2014 for Civil Works 65
02.11 50 mm down graded picked jhama Khoa consolidation in foundation trenches by Tk. 3,652.00
mixing the same with best quality local sand (F.M. 1.2) in (2:1) (khoa: sand)
proportion to achieve minimum dry density of 90% with optimum moisture content
(Modified proctor test) including breaking and screening chips,laying and spreading
in150mm layers uniformly and compacting etc. all complete and accepted by the
Engineer.
02.12 50 mm down graded picked jhama khoa consolidation in foundation trenches by Tk. 4,50B.OO
mixing in mixer machine in foundation with best quality local sand(F.M. 1.2) and
cement in (1:6:12) (cement: sand: khoa) proportion to ar.hieve minimum dry
densitY of 90% with optimum moisture content (Modified proctor test) including
breaking and screening chips,laying and spreading in150mm layers uniformly and
compaeting etc. all complete and accepted by the Engineer.
02.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available Tk. 114.00
within 90 m of the building site to achive minimum dry density of90% with
optimum moisture content (Modified proctor test) including carrying watering,
leveling, dressing and compacting to a speCified percentage each layer up to finished
level etc. all complete and accepted by the Engineer.
02.14 Clearing and disposing of excavated earth from the construction site by truck or Tk. 457.00
any other means to' a place within 30 km radius of the city or town area including
loading, unloading at both ends, leveling and dressing the carried'earth etc. complete :
accepted by the Engineer.
02.15 Earth fiHing in foundation trenches and plinth in 150 mm layers with carted earth
carried by truck or any other means loading and unloading at both ends including
leveling, watering and compacting to achive minimum dry density of 90% with
optimum moisture content (modified proctor test) including local carriage each layer
..~
up to finished level including cost of water and test (carried from beyond 300 m) etc.
all complete and accepted by the Engineer.
02.15.4 For other than Dhaka, Ctg., Sylhet, Rajshahi, Barishal, Khulna metropolitan area and Tk. 291.00
N'ganj district
~
PWD SoR 2014 for Civil Works 66
02.16.4 For other than Dhaka; Ctg., Sylhet. Rajshahi, Barishal, Khulna metropolitan area and· .
N'ganj district
02.17 Mechanical compaction of earth beyond plinth area, required for pre-approved Tk. 364.00
specific engineering purpose in 150mm layers including leveling, watering and
consolidation each layer with chain dozer, grader, roller etc. ,to achieve minimum dry
density of 90% with optimum moisture content (modified proctor test) up to finished .
level all complete and accepted by the engineer subject to submission of the method .
statement.
~.
PWD SoR 2014 for Civil Works 67
03.1 One layer of brick flat soling in foundation or in floor with first class or picked Tk. 355.00
jhama bricks including' preparation of bed and filling the interstices with local sand,
leveling etc. complete and accepted by the Engineer.
03.2 One layer of Herring bone bond (HBB) brick soling in foundation or in floor with Tk. 562.00
first class or picked jhama bricks including preparation of bed and filling the
interstices with local sand. leveling including the supply of water, other charges, costs
of tools and plants etc. all complete and accepted by the Engineer.
03.3 Brick on end edging including preparation of bed and filling the interstices with local Tk. 88.00
sand, leveling, maintaining alignment. grid etc. all complete and accepted by the
Engineer.
03.4 Mass concrete (1 :3:6) in foundation or floor with cement, sand (F.M. 1.2) and
picked jhama chips including breaking chips, screening, mixing, laying, compacting
to levels and curing for at least 7 days including the supply of water, electricity and
other charges and costs of tools and plants etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M)
03.4.1 Mass concrete in foundation (1 :3:6) with cement, brick chips and sand of F.M. 1.2 Tk. 6,319.00
03.4.2 Mass concrete in floor (1:3:6) with cement brick chips and sand of F.M. 1.2 Tk. 6,241.00
03.5 Mass concrete (1 :2:4) in foundation or floor with cement, sand (F.M. 1.2) and
picked jhama chips including breaking chips, screening, mixing, laying, compacting
to levels and curing for at least 7 days including the supply of water. electricity and
other charges and. costs of tools and plants etc. all complete and accepted by the
Engineer. (Cement: CEM-IIIA-M)
\
-~
03.5.1 Mass concrete in foundation (1:2:4) with brick chips and local sand of F.M. 1.2 Tk. 7,481.00
03.5.2 Mass concrete in floor (1 :2:4) with brick chips and local sand of F.M. 1.2 Tk. 7,403.00
03.6 Damp proof course (Ope) (1:1.5:3) in cement concrete with cement, sand (F.M.
1.2) and picked jhama or stone chips including breaking chips, screening. centering.
shuttering. casting. curing and finished with a coat of bitumen including the supply of
water, electricity and other charges and costs of tools and plants etc. all complete
and accepted by the Engineer. (Cement: CEM-IIIA-M)
03.6.1 75 mm or 3" thick damp proof course (1:1.5:3) with brick chips and 50% Sylhet Tk. 1,002.00
sand (F.M. 2.2) and 50% local sand (F.M. 1.2)
03.6.2 75 mm or 3" thick damp proof course (1: 1.5:3) with Sylhet sand (F.M. 2.2) and Tk. 1,174.00
stone chips.
03.6.3 150 mm or 6" thick damp proof course (1:1.5:3) with Sylhet sand (F.M. 2.2) stone Tk. 12,711.00
chips and water-pre ... :ng admixture/agent approved by the Engineer.
03.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 Tk. 34.00
square meter in floor or any where below cement concrete complete in all respect
. and accepted by the Engineer.
04.1 Brick works with first class bricks in cement sand (F.M. of sand 1.2) mortar (1 :6) Tk. 5,327.00
in foundation and plinth, filling the joints/interstices fully with mortar, racking out the
. joints, cleaning and soaking the bricks at least for 24 hours before use and curing at
least for 7 days etc.· all complete including cost of water, electricity and other charges
and accepted by the Engineer. (Cement: CEM-II/A-M)
04.2 Brick works .of width one brick or one and a half brick length with first class Tk. 5,637.00
bricKs in cement sand (F.M. 1.2) mortar (1 :6) in superstructure including raking
out joints, filling the interstices with mortar, cleaning and soaking the bricks at least .-::":'""';.::'":'::'::':' ':' ' :.''
for 24 hours before' use and washing of sand, necessary scaffolding, curing at least "'::·:':·.:':'>·.\'·:·~.··.·::..i:·;':':<'".'
for 7 days etc. all complete (measurement to given as 250 mm width 'for one brick
length and 375 mm for one brick and a half brick length) and accepted by. the
Engineer.(Cement: CEM-Ii/A-M)ln ground floor
04.3 Brick works with first class bricks in cement sand (F.M. 1.2) mortar (1 :4) In Tk. 6,013.00
exterior walls including filling the interstices with mortar, raking out joints, cleaning
and socking the bricks at least for 24 hours before use and washing of sand,
necessary scaffolding, curing at least for 7 days etc. all complete including cost of
water, electriCity and other charges. (measurement to given as 250 -mm width for one ."",:.';':".', ',C"."·'
brick length and 375 mm for one brick and a half brick length) accepted by the
Engineer. (Cement: CEM·IIIA-M). In ground floor
04.4 . Exposed brick works (for exterior wall without outside plaster) with special 6,984.00
quality sorted out first class bricks, very carefully laid in cement sand (F.M. 1.2) .:' •..'..,'> ..'.,....:,:.',;::;."',,.
mortar (1 :4}) in superstructure with uniform width and depth joints, true to vertical
___ I.
and .horizontallines including raking out joints scaffolding, soaking the bricks at least
for 24 hours before use, washing and screening of sand. Curing at least for 7 days
and high class .flush pointing with cement sand (F.M. 1.2) mortar (1: 1) including cost
of water, electricity 'and other charges etc all· complete and accepted by the
Engineer. (Cement: CEM·lI/A-M). In ground floor
04.5 Exposed brick works (for exterior wall without outside plaster) with automatic Tk. 6,984.00
machine made first class bricks, very careful~ laid in cement sand (F.M. 1.2)
mortar (1:4}) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints scaffolding, soaking the bricks at least
for 24 hours before use, washing and screening of sand. Curing at least for 7 days
and high class flush pointing wnh cement sand (F.M. 1.2) mortar (1: 1) including cost y})!:,;::!';,;:?i;:j'S:/j:,
of water, electricity and other charges etc all complete and accepted by the
Engineer. (Cement: CEM·II/A-M). In ground floor
04.6 Brick works Mth 10 holes machine made bricks of approved size (9.5" x 4.5" x 10,950.00
2.75") having uniform colour carefully lai~ in cement sand (r .Ivl. 1.2) mortar (1:4) in
superstructure with uniform width and depth joi"'~. true to vertical and horizontal
lines including raking out joints, filling the interstices with mortdr, cleaning and
soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curing at least for 7 days and pointing with cement sand (F .M.
1.2) mortar (1 :2) including cost of water, electricity and other charges etc. complete
and accepted by the Engineer. (Cement: CEM-IIIA-M) In ground floor
PWD SoR 2014 for Civil Works 69
04.7 Brick work with 9.5" x 4.5" x 2.75" size machine made solid klinker facing' Tk. 8,874.00
bricks having uniform colour carefully laid in cement sand (F.M. 1.2) mortar (1:4) in
superstructure with uniform width and depth joints, true to vertical and horizontal
lines including raking out joints, filling the interstices with mortar, cleaning and
soaking bricks at least for 24 hours before use and washing and screening of sand,
necessary scaffolding, curingatleast for 7 days and pointing with cement sand (F.M.
1.2) mortar (1:2) including cost of water, electricity and·other charges etc. complete
and accepted by the Engineer.(Cement: CEM-II/A-M)ln ground floor
04.8 Brick works with 9.5" x 4.5 x 2.75" size 10 hole machine made Rock·face or
11
Tk. 8,757.00
textured klinker facing bricks having uniform colour carefully laid in cement sand
(F.M. 1.2) mortar (1 :4) in superstructure with uniform width and depth joints, true to
vertical and horizontal lines including raking out joints, fillhg ·the interstices with
mortar, cleaning and soaking bricks at least for 24 hours before use and·. washing
and screening of sand, necessary scaffolding, curing at least for 7 days and pointing
with cement sand (F.M. 1.2) mortar (1 :2) including cost of water, electricity and other
charges etc. all complete and accepted by the EngineeL (Cement: CEM-II/A-M)
In ground floor
04.9 Brick works with 9.5" x 4.5" x 2.75" size 3 hole machine made reinforced Tk. 12,296.00
klinker facing bricks having uniform colour carefully laid in cement sand (F.M.1.2)
mortar (1:4) in superstructure with uniform width and depth joints, true to vertical
and horizontal lines including raking out joints, filling the interstices with mortar,
cleaning and soaking bricks at least for 24 hours before use and washing and :
screening of sand, necessary scaffolding, curing at least for 7 days and pointing with
cement sand (F.M. 1.2) mortar (1:2) including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In
ground floor
04.10 Extra cost shall be incorporated in the estimate for each additional floor for brick
works (item No.· 4.2 to 4.9)
04.10.1 Add for each additional floor up to 5th floor Tk. 130.00
04.10.2 Add for each additional floor from 6th floor to 9th floor Tk. 182.00
04.10.3 Add for each additional floor for 10th floor and above Tk. 208.00
04.11 Extra cost for brick·work for each additional meter (or part of meter) free Tk. 136.00
height of brick wall beyond 4 m from the respective floor in auditorium, go-down,
overhead water tank etc. as description of the item No. in 16, 17, 18 and 19 including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Extra cost shall be incorporated in the estimate only when both sides of
wall is uninterruptedly free beyond 4.00 meter)
04.12 Providing brick works for 200 x 100 mm facing in superstructure with 200 x 100 Tk. 1,586.00
x 50mm machine made klinker hard pressed facing t -~"ks of approved quality in
cement sand (F.M. 1.2) mortar (1 :4), including racking out joints, cutting the bricks to
required size wherever necessary including high class recessed pointing, cleaning
and soaking the bricks at least for 24 hours before use and washing and screening of
sand, necessary scaffolding, curing at least for 7 days for all floors up to 4th floor
including cost of water, electricity and other charges etc. all complete and accepted
by the Engineer.(100 x 200 mm face should be placed for facing).(Cement: CEM-
II/A-M)lnground floor
PWO SoR 2014 for Civil Works 70
04.13 Providing brick works in facing for 200 x 50 mrnin superstructure with 200 x 50 Tk . 2,091.00
.x 50 mm machine made hard pressed klinker facing red or Maroon strips of
approved quality pressed with 20 mm thick cement sand (F.M.1.2) mortar (1:4), 10
mm thick cement mortar in adjacent sites including racking out joints and cutting the .
bricks to required sizes wherever necessary with high class recessed pointing,
cleaning and soaking the bricks for at least 24 hours before use and washing of sand
necessary scaffolding, curing at least for 7 days for all floors up to 4th floor including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer. (Cement: CEM-IIIA-M).ln ground floor
04.14 Providing brick works for 200 x 62 mm facing in super~ .:·ucture with 200 x 62 x Tk. 2,065.00
16.51 mm machine made hard pressed kliriker facing RED strips of approved
quality with 20 mm thick cement sand (F.M.1.2) mortar (1:3) in adjacent side wall,
column, drop wall etc. and racking out joints, cutting the bricks to required sizes
wherever necessary with high class recessed pointing, cleaning and soaking the
bricks at least for 24 hours before use washing and screening of .sand and necessary
scaffoldings, curing at least 7 days including cost 'of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-M) In •
ground floor
04.15 125 mm brick work with first class bric~s in cement sand (F.M. 1.2) mortar (1:6) Tk. 798.00
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
04.16 125 mm brick works with first class bricks in cement sand (F.M. 1.2) mortar (1 :4) Tk. 837.00
and making bond with connected walls including necessary scaffolding, raking out
____ I __ .. __ ._ joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
04.17 Exposed 125 mm thick pointing extra ordinary ornamental brick work with Tk. 1,016.00
sorted out first class bricks iN cement sand (F.M. 1.2) mortar (1:4) and making
bond with connected walls including neCessary scaffolding, raking out joints, cleaning
and soaking the bricks for at least 24 hours before use and washing of sand curing at
least for 7 days in all floors including cost of water, electricity and other charges etc.
all complete and accepted by the Engineer.(Cement: CEM-H/A-M)ln ground floor
04.18 Exposed 125 mm thick pointing extra ordinary ornamental brick work with Tk. 1,030.00
automatic machine made first class bricks in cement sand (F.M. 1.2) mortar (1 :4)
and making bond with connected walls including necessary scaffolding, raking out
joints, cleaning and soaking the bricks for at least 24 hours before use and washing
of sand curing at least for 7 days in all floors including cost of water, electricity and
other charges etc. all complete and accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
PWD SoR 2014 for Civil Works 71
04.19 Providing 125 mm thick (Partition walls) brick work in superstructure brick work Tk. 1,499.00
(1:4) in cement sand (F.M. 1.2) mortar with 10 hole machine made ceramic' , .'
bricks of approved size having uniform colour, carefully laid in cement mortar and \
depth joints true to vertical and horizontal lines including. racking out joints, filling the
interstices with same mortar, making bond with connected walls, cleaning, soaking
brick at least 24 hours and washing of sand, curing 7 days in all floors, including cost
of water, electricity and other charges accepted by the Engineer. (Cement: CEM-II/A-
M) In ground floor
04.20 Fancy screen work with different size hollow machine made design blocks with
uniform colour, carefully laid incoloured cement sand (F.M. 1.2) mortar (1:3) in all
floors in wall with uniform mortar joints, true to vertical and horizontal line including
racking out joints, cleaning and soaking the blocks for minimum 24 hours before use
induding washing and screening of sand, scaffolding, curing etc. complete in all
respect including supply of all necessary materials including cost of water, electricity
and other charges accepted by the Engineer. (Cement CEM-IIIA-M)
04.20.1 With design block No. 3 (MeW) size: 4" x 4" X 4" or equivalent volume &design Tk. 4,102.00
In ground floor
04.20.2 With design block No.1 (MeW) size: 5.5" x 5.5" x 4" or equivalent volume &design Tk. 2,403.00
In ground floor
04.20.3 With design block No. 20 (MeW) size: 6" x 6" x 4" or equivalent volume and design Tk. 2,323.00
In ground floor
04.21 Extra cost shall be incorporated in the estimate for each additional floor for brick
and'screen block works (item No.- 4.12 to 4.20)
04.21.1 Add for each additional ~oor up to 5th floor Tk. 24.00
\
--~-
04.21.2 Add for each additional floor from 6th floor to 9th floor Tk. 32.00
04.21.3 Add for each additional floor for 10th floor and above Tk. 40.00
04.22 Klinker paving brick works in floor or pavement with machine made pressed bricks
of approved quality in cement sand (F.M. 1.2) mortar (1:4) on minimum 12 mm thick'
cement sand (F.M. 1.2) mortar (1:4) including raking out joints, cutting the bricks to
required size soaking the same 24 hours before use wherever necessary including
high class flush pointing in cement mort.ar (1:2), cleaning, curing at least for 7 days
etc. including washing and screening of sand, cost of water, electricity and other
charges complete and standard practice accepted by the Engineer.(Cement: CEM-
II/A-M)
04.22.1 100 mm thick brick on edge pavement with 200 x 100 x 50 mm size kl.inker faCing Tk. 2,599.00
bricks.
04.22.2 50 rnm thick flat brick pavement with 200 x 100 x 50 mm klinker paving bricks in 1:4 Tk. 1,523.00
cement sand mortar having 200 x 100 mm face at top.
04.22.3 50 mm thick brick pavement with 200 x 50 x 50 mm klinker facing bricks. Tk. 2,013.00
PWD SoR 2014 for Civil Works 72
04.23 125 mm thick brick pavement or flooring with first class brick on edge in cement Tk. 943.00
sand (F.M. 1.2) mortar (1 :4) on minimum 12 mm thick cement sand (F.M. 1.2) mortar
(1:4) including cutting the bricks as per requirement, cleaning and racking out joints,
finishing with flush pointing with cement sand (F.M. 1.2) mortar (1 :2) and .curing for at
least 7 days etc. including cost of water, washing and screening of sand (F.M. 1.2),
electricity and other charges complete and standard practice accepted by the
Engineer. (Cement: CEM-IIIA-M)
04.24 125 mm thick brick pavement/flooring with 10 hole machine made ceramic Tk. 1,578.00
bricks in cement sand (F.M. 1.2) mortar (1 :4) on minimum 12 mm thick cement
sand (F.M. 1.2) mortar (1 :4) including cutting the bricks as per requirement, cleaning
and racking out joints, finishing with flush pointing with cement sand (F.M. 1.2)
mortar (1:2) and curing for at least 7 days etc. including cost of water, washing and
screening of sand (F.M. 1.2), electricity and other charges etc. all complete and
accepted by the Engineer. (Cement: CEM-IIIA-M)
04.25 75 mm thick cement concrete (1 :3:6) with cement in flooring best quality coarse Tk. 526.00
sand. and 19 mm down graded picked chips including breaking chips, screening,
mixing, laying, compacting, washing and screening of sand of F.M 1.2 a.nd curing at
least for 7 days etc. including cost of water, electricity and other charges etc. all
complete and accepted by the Engineer. Cement: CEM-IIIA-M)
04.26 25 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse Tk. 332.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded brick chips including
breaking chips, screening, laying the concrete in alternate panels, compacting and
finishing the top with neat cement and curing at least 7 days in all floors including
cost of water, electricity and other charges etc. all complete and accepted by the
Engineer.(Cement: CEM-II/A-M)ln ground floor
04.27 38 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse Tk. 423.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50% ·<':ii">,"·;" .. ) ....." . i.i':..'
best local sand of FM 1.2) and 12 mm down well graded 'brick chips including
breaking chips, screening, laying the concrete in alternate panels, compacting and
finishing the top with neat cement and curing at least 7 days in all floors including
cost of water, electriciiy and other charges etc. all complete and accepted by the
Engineer. (Cement: CEM-II/A-M) In ground floor
04.28 25 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse Tk. 390.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded stone chips, laying the
concrete in alternate panels, compacting and finishing the top with neat cement and .
curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer. (Cement: CEM-Ii/A-M)
In ground floor .
04.29 38 mm thick artificial patent stone (1:2:4) flooring with cement, best quality coarse Tk. 510.00
sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and 50%
best local sand of FM 1.2) and 12 mm down well graded stone chips, laying the
concrete in alternate panels, compacting and finishing'the top with neat ce'ment and
curing at least 7 da}'s in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer.
Cement: (CEM-II/A-M) In ground floor
PWD SoR 2014 for Civil Works 73
04.30 25 mm thick artificial patent stone (1 :1.5:3) flooring with cement, best quality Tk. 409.00
coarse sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and
50% best local sand of FM 1.2) and 12 mm down well graded stone chips, laying
the concrete in alternate panels, compacting and finishing the top with neat cement
and curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and acoopted by the Engineer. (Cement: CEM-Ii/A-M) In
ground floor
04.31 38 mm thick artificial patent stone (1 :1.5:3) flooring with cement, best quality Tk. ·539.00
coarse sand (50% quantity of Sylhet sand or coarse sand of equivalent F.M. 2.2 and
50% best local sand of FM 1.2) and 12 mm down well graded stone chips,laying
the concrete in alternate panels, compacting and finishing the top with neat cement
and curing at least 7 days in all floors including cost of water, electricity and other
charges etc. all complete and accepted by the Engineer.(Cement: CEM-II/A-M)ln
ground floor
04.32 Extra cost shall be incorporated in the estimate for each additional floor for patent
stone works.
04.32.1 Add for each additional floor up to 5th floor Tk. 24.00
04.32.2 Add for each additional floor from 6th floor to 9th floor Tk. 32.00
04.32.3 Add for each additional floor for 10th floor and above Tk. 40.00
05.1 10 mm thick finished and 12 mm laying thickness situ mosaic work on floor with ',:t"::,~~f\~\::/i~'·:;
one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture' containing white cement / grey cement '.:.:',: ..:::",.\.":':<."'; ..
including preparation of mix. and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick chips (1:2:4) including making suitable panel,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80,
No.120}/cutting with mosaic machine and finishing with Minar stone and spreading
oxalic acid including breaking brick chips, screening, washing mosaic chips and
supply of all necessary materials and water, electricity and other charges in all
respect accepted by the Engineer. (Cement: CEM-II/A-M) '·'\;i'i(:·'7F:;;<;:;~
05.1.1 With Indian chips and glass strip using 100% white cement. Tk. 1,500.00
In Ground Floor
05.1.2 With Indian chips and glass strip using 100% grey cement. Tk. 1,233.00
In ground floor
05.1.3 With Pakistani chips and glass strip using 100% white cement. Tk. 1,533.00
In ground floor
05.1.4 With Indian chips and without glass strip using 100% white cement. Tk. 1,315.00
In ground floor
05.1.5 With Indian chips and without glass strip using 100% grey cement. In ground floor Tk. 1,109.00
05.1.6 With Pakistani chips and without glass strip using 100% white cement. Tk. 1.,347.00
In ground floor
05.2 12 mm thick finished and laying thickness 14.5 mm cast in situ mosaic work on
floor with one part of 10 mm machine crushed well graded dust free and properly
washed marble chips and one part of mixture containing 100% white cement
including preparation of mix and laying the same over minimum 25 mm thick artificial
patent stone flooring with brick-chips (1 :2:4) including making suitable panel,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No.
120)/ mosaic cutting machine and finishing with Minar stone including breaking brick
chips screening, spreading oxalic acid, washing mosaic chips and supply of all
necessary materials and water, electricity and other charges in all respect accepted
by the Engineer. (Cement: CEM-II/A-M)
05.2.3 With Indian chips and without glass strip. Tk. 1,396.00
In ground floor
05.2.4 With Pakistani chips and without glass strip. Tk. 1,432.00
In ground floor
PWD S~R 2014 for Civil Works 75
05.3 10 mm thick finished and laying thickness 12.5 mm silver grey situ mosaic work
on floor with one part of 10 mm machine crushed well graded, dust free and
properly washed marble chips and one part of mixture containing white cement and
grey cement in proportion (1: 1) including preparation of mix and laying the same
over minimum 25 mm thick artificial patent stone flooring with brick-chips (1 :2:4)
including making suitable panel, compacting, curing at least for 7 days, cutting with
pumic stone (No. 40, No. 80,' No. 120) and finishing with Minar stone including
breaking brick chips, screening, washing mosaic chips and supply of all necessary
materials including and water, electricity and other charges in all respect accepted by
the Engineer. (Cement CEM-IIIA-M) .
05.3.1 With Indian chips and with glass strip. Tk. 1,369.00
In ground floor
05.3.2 With Pakistani chips and with glass stnp. Tk. 1,402.00
!n ground floor
05.3.3 With Indian chips and without glass strip. Tk. 1,184,00
In ground floor
05.3.4 With Pakistani chips and without glass strip.ln ground floor Tk. 1,216.00
05.4 12 mm thick finished and laying thickness 14.5 mm silver grey cast in situ mosaic
work on floor with one part of 10 mm machine crushed well graded dust free and
properly washed marble chips and one part of mixture containing white cement dust
free and properly washed marble chips and one part of mixture containing white
cement and grey with cement in proportior. (1:1) including. preparation of mix and
laying the same over minimum 25 mm thick artificial patent stone flooring with brick-
chips (1 :2:4) including making sunable panels, compacting, curing at least for 7 days,
cutting with pumic stone (No. 40. No. 80, No. 120) and finishing with Minar stone
including breaking brick chips, screening, washing mosaic chips and supply of all
necessary materials and water, electricity and other charges in all respect accepted
by the Engineer. (Cement: CEM-IUA-M)
05.4.1 With Indian chips and with glass strip. Tk. 1,435.00
In ground floor
05.4.2 With Pakistani chips and with glass strip. Tk. 1,471.00
In ground floor
05.4.3 With Indian chips and without glass strip. Tk. 1,2~0.00
In ground floor
05.4.4 With Pakistani chips and without glass strip. Tk. 1,286.00
In ground floor
05.5 10 mm thick finished and laying thickness 12.5 mm situ mosaic work on wail with
one part of 10 mm machine crushed well graded dust free and properly washed
marble chips and one part of mixture containing 100% white cement including
preparation of mix and laying the same on 12 mm thick cement plaster (1 :4) to wall,
compacting, curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No.
120) including finishing the comers and edges and also finishing with Mine.r stC'···
and supplying all necessary materials in and water: electricity 2nd other charges in
all respect accepted by the Engineer. (Cement: CEM-IIIA-M)
PWD SoR 2014 for Civil Works 76
05.6 10 mm thick finished and laying thickness silver grey situ mosaic work on wall
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (1:1) including preparation of mix. and laying the same on 12 mm thick
cement plaster (1:4) to wall, compacting, curing at least for 7 days, cutting with pumic
stone (No. 40, No. 80, No·120) including finishing the corners and edges and also
finishing with Minar ston~ and supplying all necessary materials in and water,
electricity and other charges in all respect accepted by the Engineer. (Cement: CEM-
II/A-M)
05.6.3 With Indian chips using 100% grey cement. Tk. 1,199.00
In ground floor
05.7 10 mm thick finished laid in 12.5 mm thickness coloured situ mosaic work in floor
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white and grey cement in proportion
(1 :9) and necessary quantity of approved colouring materials including preparation of
mix and laying the same over min 25' mm thick artificial patent stone flooring with
---.~-- ... ----
brick-chips (1:2:4) including making suitable panel, compacting, curing at least for 7
days, cutting with pumic stone (No. 40, No. 80, No. 120) and finishing with Minar
stone including breaking brick chips, screening, washing mosaic chips and supply of
all necessary materials in all respects and water, electricity and other charges in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.7.1 With Indian chips and with glass strip. Tko 1,557.00
In ground floor
05.7.2 With Pakistani chips and with glass strip. Tko 1,590.00
In ground floor
05.7.3 With Indian chips and without glass strip. Tko 1,372.00
In ground floor
05.7.4 With Pakistani chips and without glass strip. Tk. 1,273.00
In grout: ~oor
PWD SoR 2014 for Civil Works 77
05.6 12 mm thick finished and laying thickness 14 mm coloured situ mosaic on floor
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (9:1) and necessary quantity of approved colourings materials including 'i~iWi~F;~<:t",!'h:'\
preparation of mix and laying the same over minimum 25 mm thick artificial patent ~>s;,r}Y;'~;;K\'i'?;:;,;:~
stone flooring with brick-chips (1:2:4) including making suitable panel, compacting,
curing at least for 7 days, cutting with pumic stone (No. 40, No. 80, No. 120) and
finishing with Minar stone including breaking brick chips, screening, washing mosaic
chips and supply of all necessary materials in all respects and water, electricity and
other charges in all respect accepted by the Engineer. (Cement: CEM-II/A-M)
05.8.2 With Pakistani chips and with glass strip. Tk. 1,675.00
In ground floor
05.8.3 With Indian chips and without glass strip. Tk. 1,453.00
In ground floor
05.8.4 With Pakistani chips and without glass strip. Tk. 1,489.00
In ground floor
05.9 10 mm thick finished and laying thickness 12,5 mm coloured situ mosaic on walls
with one part of 10 mm machine crushed well graded, dust free and properly washed
marble chips and one part of mixture containing white cement and grey cement in
proportion (9:1) and necessary quantity of approved colouring materials including
preparation of mix and laying the same on 12 mm thick cement sand (F.M. -1.2)
plaster (1:4) to walks including compacting, curing at least for 7 days, cutting with
pumic stone (No. 40, No. 80, No. 120) including finishing the corners and edges and
also finishing with Minar stone and supply of all necessary materials etc. and water, '
electricity and other charges complete in all respect accepted by the Engineer.
(Cement: CEM-II/A-M)
05.10 200 x 200 x 20 mm mosaic terrazzo tiles flooring having 10 mm thick finished
mosaic top with one part of 10 mm machine crushed well graded dust free and .
properly washed marble chips and one part of mixture containing white cement and
grey cement in 9:1 proportion in/c supply of all necessary materials etc. and water,
electricity and other charges complete ir all respect accepted by the Engineer and
preparation of mix machine pressed on 12 mm thick cement sand (F.M. 1.2 and 2.5
by 50% each) mortar (1 :2) ~;se including preparing the base; finally, setting the
tiles on 40 mm thick cement sand (F.M.1.2 and 2.5 by 50% each) mortar,
compacting, cutting with pumic stone (No. 40, No. 80, No. 120) and finishing the
corners and edges and also finishing with minar stone including screening, washing <"'~iu"'tS'.:I:/':,)\
mosaic chips and supply of all necessary materials etc. and water, electricity and
other charges complete in all respect accepted by the Engineer.(Cement: CEM-II/A-
M) .
05.10.1 200 x 200 x 20 mm (finished) mosaic terrazzo tiles flooring with Indian chips. Tk. 1,458.00
In ground floor
PWD SoR 2014 for Civil Works 78
\ -'
05.10.2 200 x 200 x 20 mm (finished) mosaic terrazzo tiles flooring with Pakistani chips. Tk. 1,489.00
In ground floor
05.11 Extra cost shall be incorporated in the estimate for mosaic and terrazzo tiles work
above ground floor (item No.- 5.1 to 5.10).
05.11.1 Add for each additional floor up to 5th floor Tk. 8.00
05.11.2 Add for each additional floor for 6th to 9th floor Tk. 16.00
05.11.3 Add for each additional floor for 10th floor and above Tk. 24.00
_.----·-1.. -----
PWD SoR 2014 for Civil Works 79
06.1 Marble stone flooring with Indian black! white marble stone of approved quality,
texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1:2) including ..
placing cement slurry below the stone, cutting the marble stone to desired size,
grinding and finishing the edges, setting in position in proper level filling the gaps
with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer.(Cement: CEM-II/A-M)
06.2 Marble stone flooring with Indian colouredl grey marble stone of approved
quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar (1 :2)
including. placing cement slurry below the stone, cutting the marble stone to desired ;'
size, grinding and finishing the edges, setting in position in proper level filling the
gaps with white cement arid colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials and water, electricity and other charges complete in all respect accepted
by the Engineer. (Cement: CEM-IIIA-M)
06.3 Supplying and setting Indian marble stone of approved quality, textured and size
on walls over 12 mm thick cement sand (F.M. 1.2) mortar (1 :2) including cutting and
grinding the marble stone slab/tile setting in position keeping horizontal and vertical
alignment correct, filling the joints with white cement, cutting and grinding the top
surface, finishing etc including water, electricity and other charges complete in all
respect accepted by the Engineer. (Cement: CEM-II/A-M)
06.4 Marble stone flooring with 18mm thick Italian colouredl grey marble stone of Tk. 8,281.00
approved quality, texture and size over 25 mm thick cement sand (F.M. 1.2) mortar
(1:2) including. placing cement slurry below the stone, cutting the marble stone to
desired size, grinding and finishing the edges, setting in position in proper level filling
the gaps with white cement and colouring pigments including supplying all necessary
equipments/materials and finishing the top by pumic stone and necessary auxiliary
materials ana water, electricity and other charges complete in all respect accepted
by the Engineer.(Cement CEM-II/A~M)ln ground floor
PWD SoR 2014 for Civil Works 80
06.5 labour Cost for making moulding in marble stone as per Architectural drawing
including cutting, grinding, finishing, supplying necessary equipment etc. complete in
all respect as per direction of the Engineer in Charge. (Cement: CEM-Ii/A-M) .
06.6 Supplying, fitting and fixing country made glazed wall tiles ,irrespective of color
&lor design, with on 20 mm thick cement sand (F.M. 1.2) mortar (1 :3) base and
raking out the joints with repective joint filler & binder including cutting, laying and
hire charge of machine and finishing with care etc. including water, electricity and
other charges complete all respect accepted by the Engineer.
(Cement: CEM-Ii/A-M). In ground floor .
06.6.1 Wall tiles le~s than , equal or equivalent to 250mmx330mm in sizes Tk. 1,230.00
06.6.2 Wall tiles more than 250x330 &less than 250x400 in sizes or equivalent Tk. 1,339.00
06.7 Supplying, fitting and fixing country made GP(Gress Porcella nato) - glazed
homogeneous floor tiles irrespective of color &Ior design, with cement sand
(F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including
cutting and laying the tiles in proper way and finishing with care etc. all complete and
accepted by the Engineer.(Cement: CEM-II/A~M). In ground floor
06.8 Supplying, fitting and fixing countrymade unglazed homogeneous floor tiles
irrespective of color &lor design, with cement sand (F.M. 1.2) mortar (1:4) base
and raking out the jOints with white cement including cutting and laying the tiles in
proper way and finishing with care etc. all complete and accepted by the Engineer.
(Cement: CEM-Ii/A-M)In ground floor
06.9 Supplying, fitting and fixing countr made mirror polished homogeneousJloor tiles
irrespective of color &lor design, with cement sand (F.M.1.2) mortar (1 :4) basp
and raking out the joints with white cement including cutting and laying the tiles in
proper way and finishing with care etc. all complete and accepted by the Engineer.
(Cement: CEM-Ii/A-M) In ground floor
06.10 Supplying, fitting and fixing country made GP homogeneous stair tiles irrespective Tk. 1,536.00 '.,
of color &lor design, with cement sand (F .M. 1.2) mortar (1 :4) base and raking out
the joints with white cement including cutting and laying the tiles in proper way and
finishing with care etc. all complete and accepted by the Engineer. (Cement: CEM-
II/A-M) In ground floor
06.11 Supplying, fitting and fixing country made floor tiles irrespective of color &lor
design,with adhesives in full thickness of tiles ,filler/tiles grout in/c cutting, shaping,
placing in proper level etc. all complete as direction of the Engineer in charge. In
ground floor
06.11.1 GP glazed homogenous floor tiles (400 x 400 mm) Tk. 1,360.00
06.11.2 GP glazed homogenous floor tiles (300 x 300 mr:n) Tk. 1,224.00
06.11.3 GP un-glazed homogenous floor tiles (400 x 400 mm) Tk. 1,374.00
06.11.5 GP Mirror Poiished floor tiles (300 x 300 mm) Tk. 1.414.00
06.11.6 GP Mirror Polished floor tiles (400 x 400 mm) Tk. 1,550.00
06.11.7 GPMirror Polished floor tiles (600 x 600 mm) Tk. 1,808.00
06.12 Extra Rate for each additional floor for Tiles and Marble Stone Works
06.12.1 Add for each add!, floor up to 5th floor Tk. 8.00
06.12.2 Add for each addl. floor for 6th floor to 9th floor Tk. 16.00
06.12.3 Add for each add!. floor for 10th floor and above Tk. 24.00
07.1 Reinforced cement concrete works using wooden shutter, with minimum
cement content relates to mix ratio 1:2:4 having minimum f Icr : 24 Mpa, and
satisfying, specified compressive strength f"c: 19 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & cement conforming to
BOS EN·197·1· CEM1, 52.5N (52.5MPa)/ ASTM-C 150 Type - " best q'uality sand
[50% quantity of best local sand (F.M. 1.2) and 50% quantity of Sylhet sand or
coarse sand of equivalent F.M. 2.2] and 20 mm down well graded pickedjhama brick .
chips conforming ASTM C-33 including breaking chips and screening, making,
placing shutter in position and maintaining true to plumb, making shutter water-
fight properly, placing reinforcement in position; mixing in standard mixer machine
with hoper fed by standard measuring boxes, casting in forms, compacting by
vibrator machine and curing for 28 days,and removing centering-shuttering after
specified time approved; including cost of water, electricity, additional testing
charges of materials and cylinders required by engineer, other charges etc. all
complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
07.1.1.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 354.00
07.1.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 413.00
07.1.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 355.00
07.1.4 Padestals, column capitals, lift walls and walls upto Ground Fle()r
07.1.4.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 412.00
07.1.5.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 394.00
07.1.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.1.6.2 Formworklshuttering, prop and necessal)' supports etc. (wooden) Tk. 485.00
07.1.7.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 459.00
07.1.8 Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.1.8.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 344.00
07.1.9.2 Formwork/shutiering, prop and necessary supports etc. (wooden) Tk. 395.00
07.1.11.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 584.00
PWD SoR 2014 for Civil Works 84
07.2 Reinforced cement concrete works using steel shutter, with minimum cement
content relates to mix ratio 1:2:4 having minimum f 'cr =24 Mpa, and satisfying a
specified compressive strength f 'c= 19 Mpa at 28 days on standard cylinders as per
standard practice of Code ACI/BNBC/ASTM &cement conforming to BOS EN-197-1-
CEM1, 52.5N (52.5MPa) I ASTM-C 150 Type - I, best quality sand [50% quantity of
best local sand (F.M. 1.2) and 50% quantity of Sylhet sand or coarse sand' of
equivalent F.M. 2.21 and 20 mm down weI/graded picked jhama brick chips
conforming ASTM C-33 inctuding breaking chips and screening, making, placing
shutter in position and maintaining true to plumb, making shutter water-tight
properly, placing reinforcement in position; mixing in standard mixer machine with
hoper fed by standard measuring boxes, casting in forms, compacting by vibrator
machine and curing at least for 28 days, removing cen~ering-shuttering after
specified time approved; including cost of water, electricity, additional testing
charges of materials and cylinders required. by, engineer, other charges etc. all
complete approved and accepted by the Engineer. (Rate is excluding the cost of
reinforcement and its fabrication, placing and binding etc)
07.2.2.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 391.00
07.2.3.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 323.00
07.2.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.2.4.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 373.00
07.2.5.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 380.00
07.2.0 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.2.6.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 415.00
\,
07.2.7.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 498.00
07.2.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.2.8.2 'Formworklshuttering, prop and necessary supports etc. (steel) Tk. 344.00
07.2.9.2 Formworklshuttering, prop and necessary supports etc. (steel) Tk. 410.00
07.2.10.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 403.00
07.2.11.2 Formwork/shuttering. prop anQ necessary supports etc. (steel) Tk. 584.00
07.3 Reinforced cement concrete works. using wooden shutter with minimum
cement content relates to mix ratio 1:2:4 having minimum fcr = 27 Mpa, and
satisfying a specified compressive strength fc =22 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to 80S EN-197-1- CEM1, 52.5N (52.5MPa) I ASTM-C 150 Type - I, best quality
Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well graded
stone chips conforming to ASTM C-33, making, placing shutter in position and
maintaining true to plumb, making shutter water-tight properly, placing
reinforcement in position; mixing in standard mixer machine with hoper fed by
standard measuring boxes, casting in forms, compacting by vibrator machine and
curing at least for 28 days, removing centering-shuttering after specified time
approved; including cost of water, electricity, additional testing charges of materials
and cylinders required by engineer, other charges etc. all complete approved and
accepted by the Engineer. (Rate is excluding the cost of reinforcement and its
fabrication, placing and binding etc)
07.3.1.2 Formwqrk/shuttering, prop and necessary supports etc. (wooden) Tk. 354.00
07.3.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 413.00
07.3.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 355.00
07.3.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.3.4.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 412.00
07.3.5.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 394.00
_ _ _ .J _ _ _ _ _ _ • _ _
07.3.6 Tee beams,.EII beams and Rectangular beams etc upto Ground Floor
07.3.6.2 Formwork/shutterilg, prop and necessary supports etc. (wooden) Tk. 485.00
07.3.7.2 Formwork/shuttering, prop and necessary supports etc. (wooden) TIt 459.00
07.3.8 Cornice, railing, drop waUs, louver, fins etc upto Ground Floor
07.3.8.2 Fori .. _/ork/shuttering, prop and necessary supports etc. (wooden) Tit 344.00
07.3.9.2 Formwork/shutterill[ ')rop and necessary supports etc. (wooden) Tit 395.00
rt )~
PWD SoR 2014 for Civil Works 87
07.3.10.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 381.00
07.3.11.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 584.00
07.4 Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix. ratio 1:2:4 having minimum f fcr =27 Mpa, and satisfying a
specified compressive strength f Ie = 22 Mpa at 28 days on standard cylinders as
per standard practice of Code ACI/BNBC/ASTM & Cement conforming to 80S EN-
197-1- CEM1. 52.5N (52.5MPa) I ASTM-C 150 Type -I, best quality Sylhet sand or
coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips
conforming to ASTM C-33, making, placing shutter in position and maintaining true
to plumb, making shutter water-tight properly, placing reinforcement in position;
mixing in standard mixer machine with hoper fed by standard measuring boxes,
casting in forms, compacting by vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time approved; including cost of water,
electricity. additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
07.4.1.2 Formworklshuttering, prop and necessary supports etc. (steel) Tk. 382.00
07.4.2.2 Formworklshutfering, prop and necessary supports etc. (steel) Tk. 391.00
07.4.3.2 Formworklshuttering, prop and necessary supports etc. (steel) Tk. 323.00
07.4.4 Padestals, column, column c;~~itals, lift walla and walls upto Ground Floor
~.
PWD SoR 2014 for Civil Works 88
07.4.4.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 373.00
07.4.5.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 380.00
07.4.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.4.6.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 415.00
07.4.7.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 498.00
07.4.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.4.9.2 Formwork/shuttering, prop and necessary supports etc. (steel) " Tk. 410.00
07.4.10.2 Formworklshuttering, prop and neces" -'"'I supports etc. (steel) Tk. 403.00
07.4.11.2 Formwork/shuttering, prop and necessary supports etc. ts(eel) Tk. 584.00
PWD SoR 2014 for Civil Works 89
07.5 Reinforced cement concrete works using wooden shutter with minimum
cement content relates to mix ratio 1:1.5:3 having minimum flcr =26 Mpa, and
satisfying a specified compressive strength f 'c =21 Mpa at 28 days on standard
cylinders as per standard practice of Code ACIfBNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa) I ASTM-C 150 Type - I, best quality
Sylhet sand or coarse sand [F.M. 2.2] and 20 mm down well graded picked jhania
brick chips conforming to ASTM C-33, including breaking chips and screening,
making, placing shutter in position and maintaining true to plumb, making shutter
water-tight properly, placing reinforcement in position; mixing in standard mixer
machine with hoper and fed by standard measuring boxes, casting in forms,
compacting by vibrator machine and curing at least for 28 days, removing centering-
shuttering after specified time approved; including cost of water, electricity,
additional testing charges of materials and cylinders required by engineer, other
charges etc. all cpmplete approved and accepted by the Engineer. (Rate is excluding
the cost of reinforcement and its fabrication, placing and binding etc)
07.5.1.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 354.00
'07.5.3.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 355.00
07.5.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.5.4.2 Formwork/shuttering, prop and necessary supports etc. (wo')den) Tk. 412.00
07.5.5.2 Forrnwoltlshuttering, prop and necessary supports etc. (wooden) Tk. 394.00
07.5.6 Tee beams, Ell beams and Rectangular beams etc upto Grol'"d Floor
~
PWD SoR 2014 for Civil Worlcs 90
07.5.6.2 Formwork1shuttering, prop and necessary supports etc. (wooden) Tk. 485.00
07.5.7.2 Formwork/shuttering, prop and necessary s.upports etc. (wooden) Tk. 459.00
07.5.8 Cornice, railing, drop walls, louver, fins etc upto Ground Floor
07.5.8.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 344.00
07.5.9.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 395.00
07.5.10.2 FormWork/shuttering, prop and necessary supports etc. (wooden) Tk. 381.00
07.6 Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1:1.5:3 having minimum fcr =30 Mpa, and satisfying a
specified compressive strength fc =25 Mpa at 28 days on standard cylinders as per
standard practice of Code ACIIBNBC/ASTM & Cement conforming to 8DS EN-197~
1- CEM1, 52.5N (52.5MPa) I ASTM-C 150 Type - I, best quality Sylhet sand or
coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips
conforming to ASTM C-33, making, placing shutter in position and maintCti"'ing true
to plumb, making shutter water-tight proPerly, placing reinforcement in position;
mixing with standard mixer machine with hopper, fed by standard measuring boxes,
casting in forms, compacting by vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time approved; including cost of water,
electricity, additional testing charges of materials and cylinders required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Rate is excluding the cost of reinforcement and its fabrication, placing and
binding etc)
PWD SoR 2014 for Civil Works 91
07.6.1.2 Formwork/shuttering, prop and necessary supports etc. (steet) Tk. 382.00
07.6.2.2 ForrrtNork/shuttering, prop and necessary· supports etc. (steel) . Tk. 391.00
07.6.3.2 Formwork/shuttering, Rrop and necessary supports etc. (steel) Tk. 323.00
07.6.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.6.4.2 Formwork/~huttering, prop and necessary supports etc. (steel) Tk. 373.00
07.6.5.2 Forrt1\\{)rk/shuttering, prop and n~cessary supports etc. (steel) Tk. 380.00
1-
07.6.6 Tee beams, Ell beams and Rectangular b~ams etc upto Ground Floor
07.6.6.1 Concrete Tk. 10,526.00
07.6.6.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 415.00
07.6.7 Floor and roof slab upto Ground Floor
07.6.7.1 Concrete Tk. 10,526.00
07.6.7.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 498.00
07.6.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.6.8.1 Concrete Tk. 10.194.00
07.6.8.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 344.00
07.6.9 Sunshade, false ceiling : Ground Floor
07.6.9.1 Concrete Tk. 10,194.00
07.6.9.2 FormwOTklshuttering, prop and necessary supports etc. (steel) Tk. 410.00
07.6.10 Stair case slab and steps upto Ground Floor
07.6.10.1 Concrete Tk. 10,794'.00 .
07.6.10.2 Formworklshuttering, prop and necessary supports etc. (steel) Tk. 403.00
~ ~
PWD SoR 2014 for Civil Works 92
07.6.11.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 584.00
07.7 . Reinforced cement concrete works using wooden shutter with minimum
=
cement contentrelates to mix ratio 1:1.5:3 having minimum fcr 30 Mpa, and
satisfying a specified compressive strength fc =25 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to BDS EN-197-1- CEM1, 52.5N (52.5MPa) I ASTM-C 150 Type- I, best quality
Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well graded
stone chips conforming to ASTM C-33, making, placing shutter in position and
maintaining true to plumb, making shutter water-tight properly, placing
reinforce~ent in position; mixing with standard mixer machine with hopper, fed by
standard measuring boxes, casting in forms, compacting by vibrator machine and
curing at least for 28 days, removing centering-shuttering after specified time
approved; including cost of water, electricity, additional testing charges of
materials and cylinders required by engineer, other charges etc. all complete
approved and accepted by the Engineer. (Rate is excluding the cost of reinforcement
and its fabrication, placing and binding etc)
07.7.1.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 354.00
07.7.2.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 413.00
07.7.3.2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 355.00.
07.7.4 Padestals, column capitals, lift walls and walls upto Ground Floor
07.7.4.2 Formwork/shuttering, prop and nece~sary supports etc. (wooden) Tk. 412.00
PWD SoR 2014 for Civil Works 93
07.7.5.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 394.00
07.7.6 Tee beams, Ell beams and Rectangular beams etc upto Ground Floor
07.7.6.2 Formworklshuttering, prop and necessary supports etc. (wooden) Tk. 485.00
07.7.7.2 Formworklshuttering, prop and necessary supports etc. (wooden) . Tk. 459.00
07.7.8 Cornice, railing, drop walls, louver, fins etc .upto Ground Floor
07.7.8.2 Fonnwork/shuttering, prop and necessary supports etc. (wooden) Tk. 344.00
t-
07.7.9 Sunshade, false ceiling:Ground Floor
07.7.9.2 Formwork/shuttering, prop and necessary ~ports etc. (wooden) Tk. 395.00
07.7.10.2 Formwor1c/shuttering, prop and necessary supports etc. (wooden) Tk. 381.00
l~.7.7.11".2 Formwork/shuttering, prop and necessary supports etc. (wooden) Tk. 584.00
'"
~
PWD SoR 2014 for Civil Works 94
07.8 Reinforced cement concrete works using steel shutter with minimum cement
content relates to mix ratio 1: 1.25:2.5 having minimum fcr = 40 Mpa, and
satisfying a specified compressive strength f'c =32 Mpa at 28 days on standard
cylinders as per standard practice of Code ACI/BNBC/ASTM & Cement conforming
to 80S EN·197-1- CEM1, 52.5N (52.5MPa)1 ASTM-C 150 Type - I, and adding
approved high range water reducing admixture of complying specific type
(generally be Type-G) under ASTM-C 494, best quality coarse sand [Sylhet sand
or coarse sand Qf equivalent F.M. 2.2], 20 mm down well graded crushed stone chips
conforming to ASTM C-33, including breaking chips and screening through proper
sieves, making and placing shutter in position and maintaining true to plumb,
making shutter water-tight properly, placing reinforcement in position; mixing with
standard mixer machine with hoper and fed by standard measuring boxes, casting in
forms, compacting by vibrator machine and curing at least for 28 days, removing
centering-shuttering after specified time approved; including cost of water,
electriCity, additional testing charges of materials and cylinders. required by
engineer, other charges etc. all complete approved and accepted by the Engineer.
(Doses of admixture in the mix to be fixed by mix design) (Rate is excluding the
cost of reinforcement and its fabrication, placing and binding etc and admixture)
07.8.1.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 382.00
07.8.2.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 391.00
07.8.3.2 Formworkishuttering, prop and necessary supports etc. (steel) Tk. 323.00
07.8.4 Padestals, column, column capitals, lift walla and walls upto Ground Floor
07.8.4.2 Formwc,'kIshuttering, prop and necessary supports etc. (steel) Tk. 373.00
07.8.5.2 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 415.00
07.8.6 Tee beams, Ell beams and Rectangular bsams etc upto Ground Floor
~ ~
PWD SoR 2014 for Civil Works 95
07.8.7.2 Formworklshuttering, prop and necessary supports etc. (steel) Tk. 403.00
07.8.8 Cornice, railing, drop walls, louver, fins etc. : Ground Floor
07.8.8.2 Formworklshuttering, prop and necessary supports etc. (steel) Tk. 584.00
07.11 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 19.00
07.12 Staircase slab and steps upto Ground Floor Tk. 194.00
07.14 Formwork/shuttering, prop and necessary supports etc. (steel) Tk. 41.00
07.17.1 Add for each addl. floor up to 5th floor Tk. 82.00
07.17.2 Add for each addl. floor from 6th floor to 9th floor Tk. 109.00 f
07.17.3 Add for each addl. floor for 10th floor &above Tk. ' 136.00
07.18 Extra rate for RCC work in additional floor: Formwork I shuttering including
curing
07.18.1 Add for each add!. floor'up to 5th floor Tk. 31.00
07.18.2 Add for each addl. floor from 6th floor to 9th floor Tk. 46.00
07.18.3 Add for each add!, floor for 10th floor &above Tk. 62.00
07.19 Extra cost for making 'as-cast' surface of the concrete approved and accepted by Tk. 308.00
the Engineer. (formwork cost)
PWD SoR 2014 for Civil Works 96
07.20 Supplying, best quality pliable, cold applied pre-formed self adhesive rubberized/
bituminous water proofing membrane of approved brand / origin / manufacturer from
an authorized local agent or manufacturer having minimum thickness 1.5 mm, lined
with 2 ply cross laminated high density polyethylene film performances and
properties all conforming to ASTM standards and laying, placing, fixing on made up
firm and dry surfaces free from hollows, sharp protrusions, contaminates etc. laid
over-lap by at least 75 mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict accordance with the
manufacturer recommendations and instructions providing all safety provisions in all
respects and accepted by the Engineer. (supplied by only manufacturer's authorised
dealer with certificate of origin) under following specification:
Backing(HDPE) thickness minimum 0.1 Omm
Membrane thickness minimum 1.40mni
Total thickness minimum 1.50mm
Cold flexibility greater than H200C : ASTM 0146
07.20.1 Supply and use of water reducing chemical admixture in concrete, complying Tk. 189.00
ASTM C-494 Type • A of approved brand / origin / manufacturer and supplied by
only manufacturer's authorised dealer with certificate of origin : The admixture
is to reduce quantity of mixing water required for normal workability and to maintain
low water-cement (W/C) ratio, for improved concrete quality ensuarance.
07.20.2 Supply and use of retarding chemical admixture in concrete, complying ASTM Tk. 195.00
C·494 Type • B of approved brand/origin/manufacturer and ·supplied by only
manufacturer's authorised dealer with certificate of origin :The admixture for
retarding setting time of concrete, there by reducing shrinkage tn concrete specially
for concrete laid in thick layers and intended delayed construction for improved
construction joints, re-concreting etc.
07.20.3 Supply and use of accelerating chemical admixture in concrete, complying Tk. 200.00
ASTM C-494 Type • C of approved brand/origin/manufacturer and supplied by
only manufacturer's .authorised dealer with certificate of origin: An admixture
that is to accelerate the setting time and early strength gain of concrete.
07.20.4 Supply and use of water-reducing and retarding chemical admixture in ·concrete, Tk. 183.00
complying ASTM C-494 Type • D of approved brand/origin/manufacturer and
supplied by only manufacturer's authorised dealer with certificate of origin :
The admixture to reduce the quantity of mixing water required to produce concrete of
given consistency, i.e. low water-cement (W/C) ratio and intend to retard. setting time
of concrete, specially for layered, thick laid concrete etc.
07.20.5 Supply and use of water·reducing and accelerating chemical admixture in Tk. . 207.00
concrete, complying ASTM C-494 Type·· E of approved brand/origin/manufacturer
and suppJied by only manufacturer's authorised dealer with certificate of
origin : The admixture to reduce the quantity of mixing water required to produce
concrete of given consistency, Le. low ~ater-cement (W/C) ratio and intend to
accelerate setting time of concrete, and early strength gain in concrete etc.
07.20.6 Supply and use of water-reducing high range chemical admiXture in concrete, Tk. 225.00
complyirig ASTM C-494 Type • F of approved brand/origin/manufacturer and
supplied by only manufacturer'~ authorised dealer with certificate of origin :
The admixture required to produce concrete of consistency by 12% or greater
(flowing concrete) and· for higher strength of concrete.
PWD SoR 2014 for Civil Works 97
07.20.7 Supply and use of water-reducing high range and retarding chemical admixture Tk. 171.00
in concrete, complying ASTM C-494 Type· Gof approved brand/origin/manufacturer
and supplied by only manufacturer's authorised dealer with certificate of
origin :Theadmixture required to produce concrete of consistency by 12% or
greater (flowing concrete) and for higher strength of concrete and intend to retard
setting"time of concrete.
07.21 Supplying, best quality pliable, cold applied pre-formed self adhesive rubberized/
"bituminous water proofing membran~ of approved brand I origin I manufacturer from
an authorized local agent or manufacturer having minimum thickness 1.5 mm, lined
with 2 ply cross laminated high density polyethylene film performances and
"properties all conforming t9 ASTM standards and laying, placing, fixing on made up
firm and dry surfaces free from hollows," sharp protrusions, contaminates etc. laid
over-lap by at least 75 mm along the edges and 125 mm at ends ensuring good
initial bond with the surfaces all complete under the strict accordance with the
manufacturer recommendations and instructions providing all safety proviSions in ali
respects and accepted by the Engineer. (supplied by only manufacturer's authorised
dealer with certificate of origin) under following specification:
07.21.1 Water-proofing membrane on external surface of primed vertical or inclined wall Ion Tk. 956.00
plastered and primed back-wall and concrete cast against membrane.
(Excluding cost of back fiU/brick wall on back/plaster when membrane laid on back-
wall and concrete cast against membrane which to be paid as per corresponding
items in this schedule)
07.21.2 Water-proofing IT'!''''mbrane on made up surface below the floor or below the Tk. 855.00
horizontal surfaces with temporary protective cover using polysterene/1.5" thick
sand-c.. ,,lent mortar in 4:1 lor by equally effective alternative. (Rate is excluding the
cost of protective cover which to be paid as per corresponding items in this schedule)
07.21.3 Water-proofing membrane on the floor or on the horizontal surfaces with permanent Tk. 891.00
protective cover & wearing coarse. (Rate is excluding the cost of protective cover
and wearing coarse which to be paid as per corresponding items in this schedule)
I
'f
PWD SoR 2014 for Civil Works 98
07.22 20 mm thick water.proofing work in masonry or on concrete surface with sand- Tk. 508.00
cement mortar mixed with specified admixture (supplied from authorized local
agent or from manufacturer comply with ASTM/BS/IS requirements, confirming
current compliance of the admixture to specification requirements like physical
properties, uniformity and equivalence in composition, performance requirements,
delivered in sealed. containers having and confirming plainly marked the proprietary
name of the admixture type under this specification, net weight and or volume,
manufacturing and expiry date, shelve me, non aggressiveness to environment and
metals in concrete etc.) under the strict accordance. with manufacturer
recommendations I instructions and providing safety provisions in aU respect etc. on
sound, firm surfaces all complete including cleaning the surface from dust, loose
particles, remains of oil, grease etc. all complete approved and accepted by the
Engineer. (Cement: CEM-II/A-M)
- ..----1- - - -
PWD SoR 2014 for Civil Works 99
08.1 Supplying, fabrication, and fixing to details as per design : Ribbed or deformed bar
reinforcement for Reinforced Cement Concrete, produc.ed and marked in
accordance with BDS ISO 6935 - 2: 2006 (or standard subsequently released
from BSTI) including straightening and cleaning rust, if any, bending and binding in
position with supply of G.J. wires, splices or laps what so ever etc. complete in all
respects and accepted by the Engineer ( Measurement shall be recorded only on
Standard Mass per Unit length of Bars, while, dia of bars exceeds its standard)
08.1 . 1 Grade 300 ( RB 300 : complying BDS ISO 6935·2:2006) ribbed or deformed bar Tk. 81.91
produced and marked according to Bangladesh Standard with minimum yield
strength,fy (ReH)= 300MPa,but fy not exceeding 314MPa and what ever is the
yield strength within allowable limit as per BNBC sec 8.3.3.51 ACI 318-11 sec
21.1.5.2, the ratio of ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and minimum total elongation at
maximum force is 17% and 8% respectively; up to ground floor
Tk. 85.00
08.1.2 Grade 400 (RB 400 1400W: complying BDS ISO 6935-2:2006) ribbed or deformed
bar produced and marked according to Bangladesh Standard, with minimum yield
strength, fy (ReH)= 400 Mpa but fy not exceeding 418MPa and what ever is the
yield strength wit~in allowable limit as per BNBC sec8.3.3.5/ACI 318·11 sec
21.1.5.2, the ratio ultimate tensile strength fu to yield strength fy, shall be at
least 1.25 and minimum elongation after fracture and miAimum total elongation at
maximum force is 16% and 8% respectively: up to ground floor
08.2 Extra rate for M.S. Fabrication work in additional floor shall be incorporated in the
estimate .
j.
08.2.1 Add for each addl. floor up to 5th floor Tk. 0.39
08.2.2 Add for each addl. floor from 6th floor to 9th floor Tk. 0.77
08.2.3 Add for each addl. floor for 10th floor and above Tk. 1.15
08.3 . Mild steel Grade 250 with minimum fy =250 MPa work in roof truss: supplying and Tk. 125.00
fabrication of mild steel sections as per design. Hoisting, fitting and fixing in position
with bolts and nuts or rivets or welded and providing two coats of anti-corrosive paint
over a prime coat of red oxide paint etc. complete and accepted by the
Engineer.(Measurement to be given for Truss member only).
08.4 Supplying fan hook 300-grade ( RB300) of 16 mm diameter M.S. rod (one meter Tk. 103.00
straight length) having rounded hook at the middle of bar in proper size so as to be
concealed within fan cup inCluding fabrication and fitting fixing in all floor accepted by
the Engineer. .
08.5 Constructing expansion joints 25 mm 138 mm gap in R.C.C. floor or roof slab or
beam provided with "V" folded copper! aluminium water stop sheet with loop notch
and inserted 75 mm concrete shoulders, the gap being filled up with mixture of hot
applied bituminous sealing compound etc. all complete and accepted by the
Engineer.
(Rate is excluding the cost of floor shoulders an~ floor finishes).
r
i
PWD SoR 2014 for Civil Works 100
OB.5.3 With Aluminium sheet and 6 mm x 75 mm size M.S. plate. Tk. 2,399.00
OB.6 Installation of water stopper at moveable and non-movable Ree green jOints as per
foiling specification.
Supprying, fitting and fixing Ribbed (with non centre bulb) PVC water stopper of
OB.6.1 Tk. 850.00
width approx. 250mm and approx 9mm thick, for immovable (non working) Ree
joints, having minimum tensile strength B.27MPa(approx.1200psi ) min ultimate
elongation 350%, approximate hardness 50, minimum tear resistance 0.017SkN/mm
(100Ibs/inch) at RCe construction green joints in basements, approved and
inconsultation with design office, providing 1.S" x 2.5" wooden batten at the top and
bottom of water stopper, holding in position and keeping the water stopper in true
horizontal or. vertical by approprate means as where necessary etc; allcomplete and ··i·;··<:·::..':.:.:·.:":::·:C''':'-'::·'
accepted by the Engineer
Supplying, fitting and fixing Ribbed with centre bulb PVC water stopper of width
OB.6.2 936.00
approx. 250mm and approx 9mm thick, for movable (working or expansion joints)
RCC joints, having minimum tensile strength S.27MPa(approx.1200psi) min ultimate
elongation 350%, approximate hardness SO, minimum tear resistance 0.017SkN/mm
(100Ibs/inch) at RCC construction green joints in basements, approved and :.:'::.:.'·.C"""\::/·:.~':>"';;::.·{·.
i.nconsultation with design office, providing 1.5" x 2.5" wooden batten at the top and
bottom of water stopper, holding inposition and keeping the water stopper in true
horizontal or vertical by approprate means as where necessary etc; allcomplete and
accepted by the Engineer.
OB.7 Supplying,.fitting and fixing 10" wide 16 SWG Aluminium Sheet water stopper in Tk. 286.00
construction joint of ReC vertical.' ··c·;·····:·.··"".:···.• ,''''';:.··:·:
OB.8 Providing bearing joints fixed or free with 2S0 x 375 x 10 mm M.S. (Grade - A36) Tk. 3,146.00
shoe plate fitted in the truss angles with 16 mm diameter M.S. rod counter sunk
rivets, welded and anchored to 250 x 375 x 10 mm .M.S shoe plate by two Nos. 19
mm dia M.S. "un rod embedded in the bed of the lintel around the reinforcement, "((:":.:+/:1':'/:(':'
cleaning and greasing the joints for all floors etc. all complete and accepted by the
Engineer.
09.1 Boringldrillin·g for cast in situ pile up to the required depth and diameter with
minimum 6 mlong temporary sleel casing, true to vertical, providing bentonite slurry
and maintaining water level in the hole, washing the hole for at least 30 minutes,
clean the bore-hole and make the bore- hole ready for placing steel cage and
concreting including hire charge of rig set with winch machine, tripod stand, trimie
pipe, cost of fuel, lubricant, mobiliz·ation, demobilization, maintenance, spares, stand-
byes, insurance coverage, water. electricity and other charges all compete approved
and accepted by the Engineer. Before commencing boring operation Contractor shall
submit the method statement of cast-in-situ pile work inctuding. sequence of boring
and casting, disposal of spoils, test result of materials to the Engineer for approval.
However, Engineer's approval shall not relieve the Contractor of his responsibilities
and obligations under cont~ct. .
09.1.1 400mmdia
09.1.1.2 Additional rate for each addnional meter beyond 20 mup to 29 m Tk. 4.00
09.1.2.2 Additional rate for each additional meter beyond 20 mup to 29 m Tk. 5.00
09.1.3.2 Addttional rate for each additional meter beyond 20 mup to 29 m Tk. 7.00
09.1.4.2 Additional rate for each additional meter beyond 20 mup to 29 m Tk. 8.00
09.1.5 600 mm
09.1.5.2 Addnional rate for each additional meter beyond 20 mup to 29 m . Tk. 9.00
PWD SoR 2014 for Civil Works 102
09.2 Removing of spoils I mud accumulated during boring for cast .in situ pile by wash Tk. 378.00
boring from working site to a safe distance by contractors own arrangement i.e. with
container set in truck or on cart including loading, unloading everything complete as
per standard practice. (Quantity should be given three times of solid volume of
boring)
09.3 Cast in situ pile with reinforced cement concrete works of high· slump by adding high Tk. 11,578.00
range water reducing admixture (ASTM C494 Type A or F complying item 7.20.1 or
7.20.6) with minimum cement content relates to mixratio 1 : 1.5: 3 having minimum
fcr = 26 Mpa, and satisfying a specified compressive strength fc =21 Mpa at 28
days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM &
cement conforming to BOS EN-197-1· CEM1, 52.5N (52.5MPa) I ASTM-C 150 Type
- I, best quality coarse sand [Sylhet sand or coarse sand of equivalent F.M.2.2], 20
mm down well graded crushed stone chips conforming to ASTM C-33, including
breaking chips, screening through proper sieves, making, placing re-bar cage· in
position, placing and removing tri-pod as per requirement, pouring the concrete in
bore-hole with the help of a trimie pipe, maintaining the trimie pipe immersed in
concrete by at least 1 meter throughout the period of concreting, maintaining
required slump, etc. mixing the aggregates with standard mixer machine with hoper,
casting in forms, all complete including water, electricity, testing of materials and
concrete etc and other charges as per design, drawing etc all complete approved
and accepted by the Engineer. (Rate is excluding the cost of reinforcement and its
fabrication, binding, welding, placing and admixture ( approx doses 150 to 250ltr per
bag of cement which to fix by mix design) }
09.4 Providing and making point welding at contact point of the spiral binders at 3.9
reasonable intervals with the main reinforcements by electric arc welding for
construction of cast in situ bored pile carefully with highly oxidized electrodes making
the points prominent and accepted by the Engineer (rate is inclusive of all materials
labour, tools and plants, electriCity and all equipment).
09.5 . Providing and making welded splice over two sides of contact by welding of Tk. 472.83
minimum 300 mm length at the lap of main reinforcement in re-bar cage to be placed
in bore-hole where necessary by electric arc welding with highly oxidized electrodes
making the joint prominent and accepted by the Engineer. (rate is inclusive of all
materials labour, tools and plants, electricity and all equipment).
09.6 Labour for breaking head of hardened cast in situ bored pile/pre-cast pile up to Tk. 3,603.00
a required length by any means but )Vithout damaging the rest and removing the
dismantled materials such as concrete to a safe distance including scraps and
cleaning concrete from steel/M.S. rods, straightening and bending of pile bars,
preparation and making platform where necessary, carrying, all sorts of handling,
stacking the same properly after clearing, leveling and dressing the situ and clearing
the bed etc. complete in all respects and accepted by the Engineer.
(Measurement will be given for the actual pi:~ "lead volume to be broken)
PWD SoR 2014 for Civil Works 103
Load Test and Report shall be conducted under the supervission of a professional
Geotechnical Engineer registered in SPERB or Geotechnical Firm registerd in PWD.
Boring and Pouring logs I Driving logs of Piles and Method statement shall be the
part of load test report. (Rates on Load test under the supervision of Experts in the
laboratory of unversities and HSRI can be found in Chapter-32)
09.8.2 For intermediate loading from 75 tonne to 125 tonne for each additional tonne. Tk. 1,050.83
08.8.3 For intermediate loading from 125 tonne to 175 tonne for each additio~al tonne. Tk. 1,050.83
09.8.4 For intermediate loading from 175 tonne to 225 tonne for each additional tonne. Tk. 1,050.83
09.8.5 For intermediate loading from 225 tonne to 275 tonne for each 3~ditional tonne. Tk. 1,050.83
PWD SoR 2014 for Civil Works 104
09.9 Pre-cast pile made in reinforced' cement concrete with minimum cement content
relates to mix ratio 1:1.5:3 having minimum fcr:: 30 Mpa, and satisfying specified
compressive strength fc =25 Mpa at 28 days on standard cylinders as per standard
practice of Code ACIIBNBC/ASTM &cement conforming to BDS EN-197-1- CEM1,
52.5N (S2.SMPa) I ASTM-C 150 Type - I, best quality coarse sand (F.M.2.2), 20 mm
down well graded stone chips conforming to ASTM C~33, mixing in standard mixture
machine and fed by standard measuring boxes, including all related works like cost·
of breaking chips, screening through proper sieves, cleaning and washing, centering
and shuttering. with M.S sheet, M.S angle, F.I bar, nuts and bolls, champering edges
if so, preparation of casting beds, laying polythene there in, placing reinforcement·
cages in position, casting, compacting by vibrators and tapered rods as where
necessary, curing {or 28 days etc. cost of water, electricity and other charges,
providing fitting fixing pile shoe in position as per design and drawing, tools, plants &
equipments, mobilization, demobilization, hire charge of driving set, labour, test of
materials and concrete etc. all complete as per design, drawing and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication, binding,
welding and placing)
09.9.1 . 250 mm x 250 mm size pre-cast pile (1:1.5:3) with stone chips Tk. 850.00
09.9.2 300 mm x 300 mm size pre-cast pile (1:1.5:3) with stone chips Tk. 1,176.00
09.9.3 360 mm x 360 mm size pre-cast pile (1: 1.5:3) wJth stone chips Tk. 1,520.00
09.10 Mobilization and demobilization of drop hammer type pre-cast pile driving rig. Tk. 3,417.00
---_._---_._---
09.11 Driving 250 mm x 250 mm size pre-cast pile with drop hammer type rig, and
maintaining Driving Log in prescibed format Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineers approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.12 Driving 300 mm x 300· mm size pre-cast pile with drop hammer type rig and
maintainir.{; Driving Log in prescibed format. Before commencing driving
ooeration, Contractor shall submit method statement for carrying the driving
Gr-cration includir.g sequence of driving to the Engineer for approval. However,
Engineer's approval shall not relieve the Contractor of his responsibilities and
obligations under contract.
09.13 Driving 360 mm x 360 mm size pre-cast pile with drop hammer type rig and
maintaining Driving Log in prescibed formal Before commencing driving
operation, Contractor shall submit method statement for carrying the driving
operation including sequence of driving to the Engineer for approval. However,
Engineer's approval shall not relieve the Contractor of his responsibilities and
obl~ations under contract.
09.14 . Mobilization and demobilzation of automatic diesel hammer mounted complete Tk. 177,757.00
rig set.
09.15 Driving 250 mm x 250 mm size pre-cast pile by rig fitted with automatic diesel Tk. 597.00
operated hammer and maintaining Driving Log in prescibed format. Before
commencing driving operation by rig fitted with automatic diesel operated hammer,
Contractor . shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approvaL However, Engineer's approval shall
not relieve the Contractor of his responsibilities and obligations ,under contract.
09.16 Driving 300 mm x 300· mm size pre-cast pile by rig fitted with automatic diesel Tk. 818.00
operated hammer and maintaining Driving Log in prescibed format. Before
commencing driving operation by rig fitted with automatic diesel operated hammer,
Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer's approval 'shall
not relieve the Contractor of his responsibilities and obligations under contract.
09.17 Driving 360 mm x 360 mm size pre-cast pile by rig fitted with automatic diesel Tk. 895.00
operated hammer and maintaining Driving Log in prescibedformat. Before
commencing driving operation by rig fitted with automatic diesel operated hammer,
Contractor shall submit method statement for carrying the operation including
sequence of driving to the Engineer for approval. However, Engineer's approval shall
not relieve the Contractor of his responsibilities and obligations under contract.
09.18 Pre-cast driven micro·pile with reinforced cement concrete works with minimum
cement content relates to mix ratio 1:1.25:2.5 having minimum fcr =35 Mpa, and
satisfying a specified compressive strength fc = 30 Mpa af 28 days on standard
cylinders as per standard practice of Code ACIlBNBC/ASTM &cement conforming to
BOS EN·197·1- CEM1,52.5N (52.5MPa) / ASTM-C 150 Type -I, best quality coarse
sand (F.M.2.5) and 20. mm down well-graded stone chips conforming to ASTM C-33,
mixing in standard mixture machine with hoper and fed by standard measuring
boxes, including cost of brt:aking chips, screening through proper sieves, cleaning
and w~shing, c{:lntering and shuttering with M.S sheet, M.S angle, F.I bar, nuts and
bolts, preparation of bed, laying polythene, placing of reinforcement cage, casting,
compacting by vibrators and tapered rods, curing for 28 days etc. including cost of
water, electricity and other charges, providing pile shoe as per design and drawing,
driving the pile up to the design depth as per standard practice or specified method
providing head cushion. all equipments including mobilization, demobilization and
hire charge of driving set, shampering, test of materials and concrete etc. including
carrying all complete approved c:~1 accepted by the Engineer. (Rate is excluding the
cost of reinforcement and its fabrication, binding, welding and placing and driving
pile) ,
PWD SoR 2014 for Civil Works 106
09.18.1 180 mm x180 mm x 7.6. mPile with reinforced cement concrete (1 : 1.25 : 2.5) with Tk. 463.00
stone chips
09.18.2 205 mm X205 mm x 7.6 mPile with reinforced cement concrete (1 : 1.25: 2.5) with Tk. 576.00
stone chips
09.18.3 Driving of 180 mm x 180 mm x 7.6 m Pre-cast Pile,and maintaining Driving Log in Tk. 170.00
prescibed format
09.18.4 Driving of 205 mm x 205 mm x 7.6 mPre-cast Pile, and maintaining Driving Log in Tk. 200.00
prescibed format
. 09.19 PDA (Pile Driving Analyzer) Test: Conducting High Strain Dynamic Testing of
piles by an expert & licensed usre of the software(s) as per ASTM 04945, providing
all relevant materials ,equipment,experts,labors,mobilizationand demobilization,data
acquisition, CAPWAP analysis, preperation of resultsin standard formsetc. complete
in all respects, approved and accepted by the engineer, where, report shall contain
relevant pile log, prevailing soil investigation report at the place, copy of expertise &
licensing.
09.19.1 PDA test upto 200 metric ton as ultiumate pile capacity : only one pile at a site to Tk. 162,377.00
test in single run
09.19.2 PDA test upto 200 metric ton as ultiumate pile capacity : upto two pile at a site to Tk.' 148,060.00
test in single run
09.19.3 PDA test upto 200 metric ton as ultiLJmate pile capacity: upto three pile at a site to Tk. 135,426,00
test in single run
---------. ------
09.19.4 PDA test upto 200 metric ton as ultiumate pile capacity : upto four pile at a site to Tk. 124,253.00
test in single run .
09.19.5 PDA test upto 200 metric ton as ultiumate pile capacity: five pile at a site to test in Tk. 114,349.00
single run (Each successive rates for more than five test piles at a site in single run
may be asked)
09.20 PIT (Pile integrity test) : Conducting. low strain dynamic testing of pile as per ASTM
D5882-The standard method for low-strain integrity testing of pile by a qualified and
approved PIT expert, preparing pile heads and providing all relevant materials,
equipment, experts, labour, mobilization, demobilization; data acquisition and ·
analysis, preparation of results in standard forms and compiling final report with
recommendations on the tests etc. complete in all respects approved and accepted
by the Engineer. (Report shall contain driving log I Boring and pouring logs, Graphs
& Statement on "Calliberation Pile" (pile that tested for its capacity and PIT done·
eralier on it, at a place of known soil profiles), Soil investigation report. (Caliberation
pile shall be made and tested first).
Method statement for conducting PIT shall be submitted the Engineer for approval;
and shall be the part of PIT report, However, Engineer's approval shall not relieve
the contractor of his responsibilities and obligations under contract.
09.20.1 Mobilization &demobilization within 100km of Dhaka to site and PIT on12(twelve) Tk. 24,021.00
Piles or less
09.20.2 Additional charge on Mobilization &demobilization beyond 100km off Dhaka to site Tk. 30.00
~ ~
PWD SoR 2014 for Civil Works 107
09.20.3 For PIT test of each additional pile after 12(twelve) pile tested. Tk. 1,201.00
09.21 Pre-cast spliced pile jointing by supplying, fitting, fixing prefabricated square shaped
two steel caps made up by 6mm thick ASTM A36 complied M.S plate, sides formed
by bent in channel shape to have only two line of joinery on faces, having min 50 mm
dia hole on its web; capping by min 12 mm thick ASTM A36 complied M.S plate
shaping the edges in 45°, having min 40 mm dia hole at centre to pass 25 mm M.S
bar 433 mm in length; jointed at channels root by welding; caps fitted with 2 nos BOS .
ISO 6935-2009: 8420 DWR complied d20 U-bar 1244mm in length by welding,
equidistance from centre holes of cap and shall have min 75 mm clear from pile
faces; and finally, the system be fitted in correct alignments on pile head positions
waiting for concreting; both the pile heads fitted with the steel caps be welded
together through v-notehes in field, whlle one of the companion segment of piles
drived in ground and other one placed over it maintaining true verticality; a/l complete
as per direction an.d stepwise approval .leading to final approvai of Engineer in
charge.
09.22.1 Driving pre-cast pile made in square cut ends{tip) without shoe of any si~ein Tk. 932
the range, 250mmx250mm to 450mmx450mm having pile segment up to 21.0m in
length; by HydrauliC Static Pile driver of approx. 180.00 tonne (metric ton) capacity;
arranged with necessary cranes, power source, maintaining driving log and record of .
pressure exerted on piles driven in to desired RL or Capacity level; complete in a/l
respect including mobilizing demobilizing of machines & equipment, handling of
piles, dressing & leveling of site, way making, surveying, layout setting etc ended
with the submission of pile driving report in three copies duly signed by professional
engineer and approved by the engineer: .
09.22.1.1 Making Pre-Cast Piles with Square Cut ends with lengths upto 21.0m in Tk. 22,807.04
reinforced cement concrete works having minimum cement content relates to mix
ratio 1:1.5:3, leading minimum fcr =30 Mpa, and satisfying specified compressive
strength fc =25 Mpa at ~8 days on standard cylinders as per standard practice of
Code ACII8NBC/ASTM & cement conforming to 80S EN-197-1- CEM1,52.5N
(52.5MPa) I ASTM-C 150 Type -I, best quality coarse sand (F.M.2.2), 20 mm down
well graded stone chips conforming to ASTM C-33, mixing in standard mixture
machine fitted with hopper and fed by standard measuring boxes, including all
related works like cost of breaking chips, screening through proper sieves, cleaning
2nd washing, centering and shuttering with M.S sheet, M.S angle, F.I bar, nuts and
bolts, champering edges if so, preparation of casting beds, laying polythene there
in, providing reinforcement & placing fitting fixing in position, casting concrete,
compacting by vibrators and tapered rods as where necessary, curing for 28 days
etc. cost of water, electricity and other charges, as per design and drawing, tools,
plants & equipments, mobilization, demobilization, labour, test of materials and
concrete etc. complete in aU respect as per design, drawing and accepted by the .'··.;(S~L':·:·:;·;?~;'.'·;'::';:<
En.gineer.
10.1 Supplying, fitting and fixing 0.457 mmthick corrugated galvanized iron sheet
(Bangladesh made) having min weight 63-65 kg per bundle (2'-6" width 70 - 72 rft
long) fitted and fixed on M.S. sections with 'J' hook or wooden purlin with screws,
limpet washers and putty etc ..all complete and accepted by the Engineer.
10.2 Supplying, fitting and fixing 1.5 mm thick fiber glass sheet roofing fitted and fixed TIt 1,240.00
on M.S. sections with 'J' hook or wooden purlin with screws, limpet washers and
putty etc. all complete and accepted by the Engineer.
10.3 0.27 mm thick galvanized iron plain sheet ridging with 300 mm lap on either side
fitted and fixed with galvanized bolts and nuts etc. all complete and accepted by the
Engineer.
10.4 1.5 mm thick plain fiberglass .sheet ridging with 300 mm lap on either side fitted Tk. 618.00 .
and fixed with galvanized bolts and nuts etc. all complete and accepted by the
Engineer.
10.5 Saftey Canopy: Supplying temporary safety canopy & around construction work Tk. 1,531.00
place where public safety is possibly be endangered due to constructional activities,
which shall be made of aligning truss system of steel sections at 1800 mm clc as
maximum and making flooring system by corrugated galvanized iron sheets of
approx O.4Smm thick. Placed on steel sections aligned perpendicular to truss at 900
mm c/c as maximum. All fitted. Fixed in position providing necessary anchors,
cables, wires, ties etc. by standard anchoring &welding, nut-bolts etc, all complete
and certifiea for safe and accepted by the Engineer
11.1 Supplying and making door and window frames (Chowkat) for all floors with
matured natural seasoned wood of req~ired size including. painting two coats of coal
tar to the surface in contact with wall, fitting and fixing in position etc. complete and
accepted by the Engineer. (All sizes of wood are finished).
111 Supplying, fitting and fixing M.S. flat bar clamp of 225 x 38 x 6 mm size having Tk. 86.00
bifurcated ends to door and window frames with necessary screws and encasing
inside the wall with cement concrete (1:2:4) etc. complete and accepted by the
Engineer.
11.3 Supplying, fitting and fixing M.S. flat bar clamp 150 x 38 x 6 nim size having Tk. 89.00
bifurcated ends to door and window frames with rowel plug, necessary screws etc.
including cutting groove in Chowkat if necessary etc. complete in all respect ·
accepted by the Engineer. '
11.4 .Supplying, fitting and fixing double leaf door frame for all floors with 38 x 38 x 6 mm Tk. 563.00
M.S. angle fitted with 250 mm long 6 Nos. of iron clamps of same size,(with one end f'
bifurcated) with the vertical members of the frame, fIXing the frame in wall with
cement concrete (1 :2:4), mending good the damages, fIXing 6 Nos. of 100 mm size
iron hinges with the vertical members of the frame all complete including cutting,
sizing, welding, fabricating, carrying from work-shop to sHe and local carriage, curing
etc. complete as per plan and drawing and accepted by the Engineer.
11.5 Supplying, fitting and fixing of door frame for single leaf in all floors with 38 x 38 x 6 Tk. 554.00
mm M.S. angle, fixing 130 mm long 6 Nos. of iron clamps of same size (with one end
bifurcated) with the vertical members of the frame, fixing the frame in wall with
cement concrete (1 :2:4), mending good the damages, fixing 4 Nos. of 100 mm size
iron hinges with the vertical members of the frame all complete including cutting,
sizing, welding, fabricating, carriage from workshop to sHe including local carriage,
curing etc. as per plan and drawing etc. all comp:e~a and accepted by the Engineer.
(Running meter of the doorframe will be "onsidered towards measurement).
11.6 Supplying seasoned wood and making roof truss of any size with wall plates as
per design inlc suppl~ng, fabricating and hoisting, scaffolding, fitting and fixing in
position with bolts, nuts, coat tarring in 2 coats etc. all complete and accepted by the
Engineer.
(All sizes of wood are finished).
~,
PWD SoR 20'14 for Civil Works 110
11.7 Supplying and making seasoned wooden hand rail of stair case etc. including .
necessary molding with proper corner finishing as per design, fitted and fixed in
position in all floors etc. all complete and accepted by the Engineer.
"
PWD SoR 2014 for Civil Works 111
12.1 Supplying, fitting and fixing 38 mm thick well matured, seasoned (min 10" wide
plank) solid wood single leaf door shutter having top rail style of sections 100 mm "·"r<~'''.·>;.r,',':·.<::·'''<
X 38 mm, lock rail 125 x 38 mm and bottom rail 225 x 38 mm. Closed joints with 25
mm x 12 mm size wooden peg and provided with best quality 4 Nos. 100 mm iron .,:,',:;:,,,>:;,,:'::'.:.::'::
hinges 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long iron tower and
socket bolts, 2 (two) Nos. heavy type nickel plated handle, hinged cleats, buffer
blocks and finished by sand papering etc. all complete in all floors and accepted by
the Engineer.(AII sizes of wood are finished)
12.2 Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) solid wood single leaf flush door sh,utter having a frame of top lock'
and bottom rail of sections 100 mm x 12 mm styles 100 mm x 38 mm covered with
100 mm x 12 mm plank, screwed to each face and provided with best quality 4 Nos.
100 mm iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long
iron tower and socket bolts, 2 (two) Nos. heavy type nickel plated handles, hinged
cleats, buffer blocks and finished by sand papering etc. all complete in all floors and .':',"";"i::::::;;::">'>.
1'
accepted by the Engineer. (All sizes of wood are finished)
12.3 Supplying, fitting and fIXing 38 mm finished well matured, natural seasoned (min 1C" Tk. 14,344.00
wide plank) wooden ornamental special design (equivalent hatil) both sides single
panel flush door shutter with top and middle rail 150 rnm x 38mm bo ..... m rail 225
mm x 38 mm and style 125 mm x 38 mm, having vertical panels 175 mm x 38 mm
in.lc minimum 12 mm lap to each panel providing 4 nos, best quality 100 mm brass
hinges, 12 mm dia best quality 200 mm & 300. mm brass socket and tower bolts
2(two) now heavy type best quality brass handle hinges cleats, wooden buffer blocks
in/c supply of necessary nails and screws finished by making design by machine
finished etc. al/ complete in all floors and accepted by the Engineer (Ctg. tea~
wood).
PWD SoR 2014 for Civil Works 112
12.4 Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) wooden double leaf panel door shutters. Top rail and styles of
sections 100 mm x 38 mm, lock rail 125 mm x 38 mm and bottom rail 225mm x 38
mm, paneling 38 mm thick both sides raised, provided with best quality 6 Nos..100
mm.iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 225 mm long iron ""'''',';,\ic:',·.:,,'·;':;·:·
tower and socket bolts, 2 (two) Nos. heavy type nickel plated handle, 1 No. hatch-
bolt hinged cleats, buffer blocks and finished by sand papering, necessary screws
etc. all complete in all floors and accepted by the Engineer. (Double leaf. All sizes of """bJ,':"''''::\'''/
12.5 Supplying, fitting and fixing 38 mm thick well matured, natural seasoned (min.10"
. wide plank) wooden double leaf panel door shutters. Top rail and styles of .
sections 100 mm x 38 mm ..lock rail 125 mm x 38 mm and bottom rail 225 mm x 38
mm. paneling 25 mm thick one side raised, provided with best quality 6 nos. 100 mm
iron hinges, 2 (two) Nos. best quality 12 mm dia 300 mm and 200 mm long iron
tower and socket bolts, 2 (two) Nos. heavy type nickel plated handles, 1 No. hatch-
bolt hinged cleats, buffer blocks and finished by sand papering, necessary screws
etc. all complete in all floors and accepted by the Engineer.(Double leaf. All sizes of
wood are finished) i·:·::<'·"::':·'·..::·:.··:':<·".··
12.6 Supplying, fitting and fixing 38 mm finished thick well matured, natural seasoned
(min. 10" wide plank) wooden grooved single panel flush door shutters with top
and middle rail 100 mm x 38 mm, bottom rail 225 mm x 38 mm and style 100 mm x
38 mm, having vertical panels 100 x 38 mm including keeping 6 mm x 12 mm even
groove all around and minimum 12 mm grooved lap to each panel. Providing 4 Nos. "~"'.".:'">.;:' .. (,:y<,,,
best quality 100 mm iron hinges, 12 mm dia best quality 200 mm and 300 mm iron
socket and tower bolts, 2 (two). Nos. heavy type best quality nickel plated handle
hinged cleats, wooden buffer blocks including supply of necessary nails and screws,
finished by sand papering etc. complete in all respect in all floors as per drawing and'
as per standard practice and accepted by the Engineer. (All sizes of wood are
finished).
12.7 . Supplying, fitting and fixing 36 mm thick and having density 400 kg/cumsolid
particle board single leaf flush door for all floors for internal use made of well
matured mechanical seasoned Rubber (Malaysian timber) or other approv,ed wooden
frame having finished size 35 x 50 mm around upon which 1.2 mm thick veneer (total
two Nos. of veneers one of 0.7 mm horizontally made of gorjon and another of 0.5
mm vertically made of Burma Teak or Champa or Chapalish or Garjan wood) with
necessary screws are pested on each side by mechanized process and provided .
with best quality 4 Nos. 100 mm iron hinges, 2 Nos. best quality 12 mm iron dia 300
mm and 225 mm long iron tower and socket bolts, 2 (two) Nos. heavy type nickel ··:.:."'·.';···;·.;i.·.·: .. C,
plated handles, hinged cleats, buffer blocks etc. complete and accepted by the
Engineer.
12.8 Manufacturing and supplying, fitting,. fixing well matured, natural seasoned (min 10"
wide plank) wooden fixed louver shutters having 62 x 125 mm frame and inner
horizontal wooden louver 150 x25 mm size spaced @50 mm clc fixed with frame in
grooves including cost of screws, nails, 12 mm x 12 mm size wooden bit, preparing.
the surface by sand papering etc. complete in all respect as per drawing and .
accepted by the Engineer. (All sizes of wood are finished). '
12.9 Supplying, fitting and fixing well matured, natural seasoned (min 10" wide plank)
wooden glazed ventilator louver shutters for all floors having wooden outer frame ~";A<::;;<;:;f:;,>
of section 62 x 125 mm (finished) with 62 x 125 mm (finished) size vertical divider
with inner 50 mm x 38 mm shutter and with 3 Nos. horizontal 38 mm x 38 mm sash :.·;.::,'>" ... '···.:'·:i;··
bar in each part and inner horizontal glazed louver of size 150 x 6 mm (local) fixed in
frame @ 154 mm clc by cutting grooves in the frame including cost of screws,
wooden bit, pivots, sand papering,' cutting glass to required size etc. all complete as
. per design, drawing and as per standard practice and accepted by the Engineer. '(AII
sizes of wood are finished).
12.10 Supplying fitting and fixing 38 mm thick well matured, natural seasoned (min 10"
wide plank) wooden door shutters for all floors having styles and rails of section
150 mm x 38 mm and 5 mm glass panes fitted and fixed with wooden batten, putty
and nails including supplying and fitting and fixing 50 mm dia best quality round door
lock. 12 mm dia, 1200 mm long iron tower bolt and 8 Nos. 100 mm iron hinges to
each shutters, 2 Nos. nickel plated handle, hinged cleats, buffer blocks, screws,
finished with necessary sand papering and putty works etc. complete and accepted
by the Engineer. (All sizes of wood are finished).
12.11 Supplying, fitting and fixing 25 mm thick well matured natural seasoned (min 10" . Tk. 5,505.00
wide plank) Kathal wood door and window shutters for all floors having 75 x 25
mm 'Z' battens, provided with best quality 3 Nos. 100 mm iron hinges, 2 Nos. 62 mm .
dia iron ring fitted with nuts, 2 Nos. best quality 12 mm dia, 300 mm and 225 mm
long iron tower and socket bolts, hinged cleats, buffer blo.cks, screws and finished
with sand papering in all floors etc. complete and accepted by the Engineer. (All
sizes of wood' are finished).
12.12 Supplying, fitting and fixing 38 mm thick well matured natural seasoned (min 10"
wide plank) wood glazed window shutters for all floors having horizontal and
vertical. sections of 87 x 38 mm and sash bar 38 x 38 mm· fitted with 3 mm glass
panes with putty and nails and provided with best quality 4 Nos. 75 mm iron hinges,
2 (two) Nos. best quality 12 mm dia 250 mm and 150 mm long iron tower and socket
bolts, nickel plated handles 225 mm long catch hooks or hinged cleats, buffer blocks, .
necessary screws and finished with sand papering for all floors etc. complete and .
:~f~'
_ _ -.-1.- .... _
accepted by the Engineer. (All sizes of wood are finished). '.
12.12.1 Kathal
.. Tk. 5,567.00
12.13 Supplying, fitting and fixing 38 mm thick well matured, seasoned (min 10" wide
plank) wood window shutter one third glazed and two third raised paneling on
both sides and 38 mm thick for all floors having horizontal and vertical sections of 87
mm x 38 mm and sash bars 38 x38 mm fitted with 3 mm glass panes with putty and
nails and provided with best quality 4 Nos. 75 mm iron hinges. 2 (two) Nos. best
quality 12 mm dia 250 mm and 150 long iron tower and socket bolts, nickel plated
handles, 225 mm long catch hooks or hinged cleats, buffer blocks and finished by .
sand papering for all floors etc. complete and accepted by the Engineer. (All sizes of .
wood are finished).
~ ~
PWD SoR 2014 for Civil Works 115
12.14 Seasoning of timber in a recognized mechanical timber seasoning plant up to a Tk. 16,203.00
moisture content of 12% - 16% by weight as measured by a electric moisture meter
or any other moisture measuring device etc. complete in all respect including.
loading, unloading, carriage at both ends accepted by the Engineer.
12.15.1 Supplying, fitting and fixing steel glazed window shutter for all floors with frames as Tk. 5,572.00
per design having 25 x 25 x 5 mm angle section for Chowkat and shutters and 50 x
25 x 5 mm T- section used for vertical member and 25 x 5 mm F.I. bar- for making ./\::?p·;,c'>"e:;:r:::,:/,:,i
box (combining with angle) and 25 x 19 x 5 mm Tee used for glass divider etc. :. ."-::>:::.,,.,,::::...•;:.':.:: .
including aU cost of charges for welding, riveting etc. supplying all essential fittings,
like iron hinges, plate handle, pin-stopper, adjustable cleat and· clamps, fitting and
fixing the frame including. supplying, fitting, fixing 3 mm glass panes by pucca putty.
and making necessary holes in walls and R.C. C works and necessary fitting· with
C.C. (1 :2:4) and mending good the damages including. all cost of carriage, workshop
charges, electricity, and labour for fillings, fixing, curing etc.' all complete and
accepted by the Engineer.
12.15.2 Supplying, flfting and fixing M.S. door shutter made with 1.5" x 1.5" x X" angle outer Tk. 5,828.00
frame, inner member 1" x X" F.I. bar, cladding with 16 BWG M.S. sheet, hinged with
2" x 2" x X" M;S. angle Chowkat. .
12.16 Supplying, fitting and fixing steel glazed window shutter for all floors with frames as
per design having 19 x 19 x'19 x 3 mm Z-section in frame and 19 x3 mm F.I. bar for
making T~section for horizontal dividers of shutters and 25 x 3 mm F.I. bar for middle
vertical members of frame including all cost of charges for fabrication and
manufacture by welding riveting etc. supplying all essential fittings like 2 Nos.
stopper, handle, 150 mm long 3 Nos. adjustable deats, iron pins, hinges, 150 mm
long 4 Nos. clamps, for fitting frame including supplying, fitting, fixing 3 mm glass
panes by pucca putty and making necessary holes in brick and RC.C. wall or
member as necessary filling with C.C. (1:2:4) and mending good the damages
including all cost of carriage, electricity, workshop charges and labour in fitting, fixing
etc. all complete as per drawing and design and accepted by the Engineer.
12.16.1 With provision for fan-light (total wt of grill wnhout glass panes is min 28.13 kg for ·:··:i'.::'·"~nn.,i':·,<': Tk. 3,549.00
15 sft)
12.16.2 Without provision for fan-light (total wt of grill without glass panes is min 24.84 kg .:,"... .,. ...... .' Tk. 3,304.00
for 15 sft)
12.17 Manufacturing, supplying fitting and fixing of fixed glazed frame for all floors with Tk. 3,156.00
oute~ i1emberof 19 x 19 x 19 x 3 mm Z-section and vertical and horizontal dividers
of 19 x 19 x 3 mm T-section including all cost of fabrication and welding, supplying
and fixing of 19 x 19 x 3 mm angle clamps of 150 mm length (with one end
bifurcated) of required Nos, with the frame, fixing the frame in wall with (1 :2:4)
cement concrete in the hole for clamp after making necessary grooves, supplying
and fixing of 3 mm glass panes with pucca putty, mending good all damages,
painting iron face with two coats of synthetic enamel paint over a coat of anti-
corrosive priming to approved colour and quality etc. cost of electricity, workshop
charges, c(lrriage etc. aI/ complete as per drawing and accepted by the Engineer.
[Rate is excluuing the cost of painling}(Scope of work of this item is in staircase and
over partition wall etc.) .
PWD SoR 2014 for Civil Works '116
12.18 Supplying, fitting and fixing 25 mm thick wooden double leaf fly proof wire mesh
window shutter for all floors with 75 x 25 mm vertical and horizontal style and sash
bar of 38 x 25 mm section provided with 24 8.W;G. G.I wire mesh netting of 20 mesh
fitted and fixed with shutter by 12 x 12 mm wooden bit, brass screws, nails etc.
including supply of all necessary fittings such as 2 Nos. 150 mm long brass tower
and socket bolt of best quality 4 Nos. 75 mm brass hinges, heavy type 2 Nos. 150.
mm long catch hook and 100 mm long brass handle 2 Nos. including fitting and fixing
the same in. position with frame with supply of necessary screws and nails etc.
complete and accepted by the Engineer. (All sizes of wood are finished)
12.19 Supplying, fitting and fixing of well matured louver shutter having 75.50mm x 38mm Tic .14,259.00
size all around frame and inner horizontal wooden louver blade 65mm x 20mm
spaced @ 38mm clc, fixed with frame in grooves including cost of nails, handle,
tower bolt, screws (brass fitting) etc. a" complete in all respect as per drawing and
direction of the Engineer in charge.
12.20 Supplying, fitting and fixing 3" X 3/4" Chittagong Teak wood moulding bit as per Tk. 1,090.00
design etc. all complete approved and accepted by the Engineer. .
12.21 Extra cost for using brassl SS fittings in place of iron fittings in doors & windows
for a" floors (super quality local).
12.22 Supplying, fitting and fixing of made in hydraulic door closer (big size) including a" Tk. 2,521.00
necessary tools and accessories etc. all complete approved and accepted by the
Engineer.
12.23.1 Supplying, fitting and fixing MORTICE door lock approved and accepted by the Tk. 1,620.00
Engineer.
12.23.2 Supplying, fitting and fixing Rir.11 round door lock approved and accepted by the Tk. 962.00
Engineer.
12.24 Supplying, fitting and fixing of best quality magnetic door shock absorber including Tk. 272.00
all necessary tools and accessories etc. all complete approved and accepted by the
Engineer
12.25 Supplying, fitting and fixing best quality heavy type 19 mm dia and to 300 mrn long Tk. 403.00
brass hasp bolt including cutting grooves in door shutter and frames, screws etc. a"
complete approved and acceptea by !tit:: Engineer.
13.1 Supplying, fitting and fixing window grills made of 16 mm dia M.S. rod @ 100 mm Tk. 2,161.00
clc fitted with 3 (three) Nos. horizontal M.S. flat bar (38 x 6 mm) including fabrication, .'\;.,::. :'\\);:':Ai'\(,;
welding, riveting, cost of electricity, workshop charges, carriage, fixing with pre- :)).;:.j.::":. .•:.:.<:<:<
placed clamps in walls/RCC member for all floors etc. complete and accepted by the
Engineer. (Total weight per sqm should. be approx. 22.8 kg and add or deduct @ Tk.
35.00 for each kg excess or less respectively)
Supplying, fitting and fixing window grills of any design made of mild steel section
13.2. Tk. 1,545.00
approx. 20. x 3 mm) with outer frame of apprQx 25 x 6 mm) F.I. bar fabricating,
welding, cost of electricity, workshop charges, carriage, fixing with pre-placed clamps
in walls or RCC member, all necessary tools and plants etc complete for all floors
and accepted by the Engineer. (Total weight per 'sqm should be approx 11.0 kg. and
add or deduct @Tk. 140 for each kg. excess or less respectively)
13.3 Supplying, fitting and fixing window grills of any design made with approx 20 x 5 mm" Tk. 1,640,00
F.I. bar as inner and outer section; including fabricating, welding cost of electricity
and tools and plants etc. complete for a/l floors accepted by the Engineer.
(Total weight per sqm should be min 12 kg. and add or deduct. @ Tk. 136 for each
kg. excess or less respectively)
13.3.1 Supplying, fitting and fixing window grills of any design made with approx 20 x 5 mm Tk. 1,515.00
F.I. bar as inner members but no outer frame; including fabricating, welding cost of
electricity and tools and plants etc. complete for all floors accepted by the Engineer. .<,.\,•. J?~t.::.;:<
(Total weight per sqm should be approx 10 kg. and add or deduct. @ Tk. 152 for ·:;·· . ,. '.: . .···>.·:·,:.·:::::. .:.'i:. .·y·.
each kg. excess or less respectively)
13.4.1 Supplying, fitting, fixing window grills of any design made with approx 25 x 6 mm F.1. Tk. 2,262.94
bar as both outer and inner section; including fabrication, welding, cost of electricity
workshop charges, carriage, cutting grooves, mending good the damages, tools and
plants etc. complete for all floors accepted by the Engineer. (Total weight per sqm
should be approx 21 kg. and add or deduct @Tk. 113 for each kg. excess or less
respectively)
13.4.1.1 Supplying, fitting, fixing window grills of any design made with approx 25 x 6 mm F.I. Tk. 2,041.00
bar as inner section but no outer frame; including fabrication, welding, cost of
electricity workshop charges, carriage, cutting grooves, mending good the damages,
tools and plants etc. complete for all floors accepted by the Engineer. (Total weight ::';;":::(J'<' •. :":'.::}:':'.
per sqm should be approx 18 kg. and add or deduct @ Tk. 108 for each kg. excess ':".<.',:j:'.. '<";.,>,.'.:":::'.:.
or less respectively)
13.4.2 Supplying, fitting and fixing window grill made of M.S. section approx 25 x 6mm outer """",':·.·~nIT1"·, ..:·, Tk. 1,747.85
frame and approx 20 x5mm inner memr;~: as per drawing and design approved and ,:... ,:,:.<.,""':".,:':;.'.'.,
accepted by the Engineer. (Total weight per sqm should be min 14 kg. and add or ,. ·.·.:.:.•. :..•·.i:,::. \;..
deduct @Tk. 125 for each kg. cAcess or less respectively)
13.5.1 Supplying, fitting and fixing window grill made of approx12mm x 12mm M.S. solid bar Tk. 2,416.00
140mm clc with outer frame of approx 38 x6mm F.I. bar as per design approved and
accepted by the Engineer.
13.5.2 Supplying, fitting and fixing window grill made of approx 10mm x 10mm M.S. solid ·.",....·'..... 11[' .. :·",.· Tk. 2,159.00
bar 140mm clc with outer frame of approx 38 x 6mm F.I. bar as per design approved
and accepted by the Engineer. .
· PWD SoR 2014 for Civil Works 118
13.6 Supplying, fitting and fixing window grills made of mild steel section 25 mm x 3 Tk. 1,629.00
mm including fabrication, welding, cost of electricity, workshop charges, carriage, .
fixing with pre-placed clamps in walls or RCC member, all necessary tools and plants
etc complete for all floors and accepted by the Engineer...
(Total weight per sqm should be min 0.81 kg. and add or deduct @ Tk. 59.00 for '
each kg. excess or less respectively)
13.7 Supplying, fitting and fixing veranda grill made of 10 mm dia M.S. rods provided Tk. 2,080.00 .
75 mm clc in any position both ways as per-design with outside frame 25 x 25 x 6
mm M.S. angle including fabricating welding in each point painting.2 coats of
synthetic enamel paint over a coat of anti-corrosive priming including cost of
electricity, tools and plants, workshop charges, carriage of the same including cutting .
groves in the R.C.C. or brick work, mending good the damages with C.C. (1 :2:4) etc.
complete for all floors accepted by the Engineer. [Rate is excluding the cost of
painting]
(Total weight per sqm should be min 57.68 kg. and add or deduct @ Tk. 35.00 for
each kg. excess or less respectively)
13.8 Supplying, fitting and fixing and fixing verandah grills made of 3/8" dia M.S. rod " Tk. 2,353.00.
placed @ 3" clc both ways fitted with outer frame of M.S. angle 1" x 1" x %" as per
drawing and approved and accepted by the Engineer.
14.1 Supplying fitting and fixing of Aluminium swing door with spandrel as per the U.S.
Architectural Aluminium Manufacturer's Association (MMA). standard specification
having 1.8 mm thick wall frame size 101.60 mm. 44.45 mm. 83.21 mm). 2.33 mm
thick shutter size (54 mm, 46 mm), 0.99 mm thick door glass bit (size 16.54 mm.
14.49 mm 0.115 kg/m), 2.5 mm thick clousure section (size 101.60 mm, 42.93 mm
1.2 mm), 106.60 mm clousure cover (0.45 kg/m), 4 mm thick floor bottom (size
101.60 mm. 12.70 mm'1 kg/m), 1.8 mm thick shutter bottom (size 82.6 mm, 43.99
mm, 0.60 kg/m), 1.8 mm thick shutter top (size 51 mm, 43.99 mm, 1.88 kg/mLand
2.3 mm to 4.01 mm thick handle (size 101.60 mm, 38.10 mm, 25.40 mm short, 1.35 .
kg/m) section of all aluminum members will be anodized to aluminium bronze/silver.
colour with a coat not less than 15 micrones in thickness and density of 4 mg per
squ~re cm etc. including all accessories like swing door clousure, swing door lock,
swing door mohiar, labour charge, fabrication, fitting fixing in position, carriage and
electricity charge kee~ng provision for fitting 5 mm thick glass including neoprene
sealant etc. complete in all respect as per drawing and accepted by the Engineer.
(Total weight min 23 kg/m2)
14.2 Supplying fitting and fixing of Aluminium swing door as per the U.S. Architectural
Aluminium Manufacturer's Association (AAMA) standard specification having 1.8 mm
thick wall frame size 101.60 mm. 44.45 mm. 83.21 mm). 2.33 mm thick shutter size
(54 mm, 46 mm), 0.99 mm thick door glass bit (size 16.54 mm. 14.49 mm 0.115
kglm), 2.5 mm thick clousure section (size 101.60 mm, 42.93 mm 1.2 mm), 106.60
mm clousure cover (0.45 kg/m), 4mm thick floor bottom (size 101.60 mm. 12.70 mm
1 kg/m), 1.8 mm thick shutter bottom (size 82.6 mm, 43.99 mm, 0.60 kg/m), 1.8 mm
thick shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) and 2.3 mm to 4.01 mm thick
handle (size 101.60 mm, 38.10 mm, 25.40 mm short, 1.35 kg/m) section of all
aluminum members will be anodized to aluminium bronze/silver colour with a coat
not less than 15 micrones in thickness and density of 4 mg per square em etc. .
including all accessories like swing door clousure, swing door lock, swing door
mohiar, labour charge, fabrication. fitting fixing in position, carriage and electricity
charge keeping provision for fitting 5' mm thick glass including neoprene sealant etc.
complete in all respect as per drawing and accepted by the EnS.' leer.
(Total weight min 23 kglm2)
14.3 Supplying, fitting and fixing of Aluminium composite swing doors with fixed
partition as per the U. S. Architectural Aluminium Manufacturer's Association i"·'··',,:,i'''/<'.·.:·'·:
(AAMA) standard specification having 1.5 mm thick wall frame (size 101.60, 44.45
mm, 0.86 kg/m), 1.8 mm thick shutter side (size 54 mm, ·46 mm, 1.2 kg/m), 1 mm
thick door glass bit (size 16.54 mm, 14. 49 mOl, 0.115 kg/m), 1.8 mm thick closure
section (size 101.54 mm, 42.93 mm, 1.20 kg/m) , 1.5 thick closure cover (101.60
mm, 0.45 kg/m)1 4 mm thick floor bottom (size 101.60 mm, 12.70 mm, 1 kg/m), 1.8
mm thick shutter bottom (size 86.60 mm, 43.99 mm ,0.60 kg/m), 1.8 mm thick .
shutter top (size 51 mm, 43.99 mm, 1.88 kg/m) 2.3mm to 4.01mm thick handle
(short) (size 101.60 mm, 38.10 mm, 25.40 mm, 1.35 kg/m), 1.5 mm thick top and ;
. side (size 101.60 mm, 44.45mm, 1.3 kg/m) , 1.50 mm thick bottom (size 101.35 mm,
44.45 mm, 1.10 kg/m), 1.50 mm thick bottom cover (44.32 mm, .19.61mm, 0.392
kg/m), 1.50 mm thick grouve cover size 83.21 mm, 16.00 mm, 0.57 kg/m), 0.99 mm :::'::~;,,,ii\:i;Y'.:'<'.::'>.
thick fixed glass protector'(size 39.09 mm, 14.81 mm, 0.188 kg/m), 0.99 mm thick "':""""',;'"'.'.'<'.';":.""',,
fixed glass protector bit (size 15.75 mm, 14.81 mm, 0.13 kg/m) section of all ··",'·;J'·'.O·"·,·'::'.:·:,·,:
aluminium members will be anodized to aluminium bronze/silver colour with a coat
not less 15 microns in thickness and density of 4 mg per square cm etc. (Total (Vi) :\·':":.')'::;":;'Cl'
. weight min 69.699 kg) keeping provision for 5mm of glass panes with cost
including all accessories like swing door clouser, swing door lock , swing door
mohair, flush bolt, bolts and nuts including sealants, labour charge for fitting, fixing
by angles, screws, mohiar, washer, machinery, cost of fabrication, making the
grooves, mending good the damages, electricity. etc.eomp/ete in all respect as per
drawing and accepted by the Engineer.
14.4 Supplying, fitting and .fixing of Aluminium sliding doors as per the U.S. Architectural
Aluminium Manufacturer's Association (AAMA) standard specification having 1.2 mm
thick outer bottom (size 75.50 mm, 17.79 mm, 0.528 kg/m) , 1.2 mm thick outer top
(size 7S.50 mm, 26.80 mm, 0.78 kg/m) 12 mm thick shutter top (size 33 mm, 26.80
mm, 0.536 kg/m), 1.2 mm shutter bottom (size 60 mm, 24 mm, 0.736 kg/m) , 1.2 mm
thick outer side(size 75.50 mm, 19.90 mm, 0.616 kg/m) 1.5 mm thick shutter lock
(size 49.20 mm, 26.20 mm, 0.661 kglm), 1.2 mm thick inter lock (size 34.40 mm,
32.10 mm, 0.665 kg/m), 1.2 mm thick shutter divider (size 31.75 mm, 0.535 kg/m)
sections all aluminium members (Total weight 14.789 kg) will be anodized to .""".".".""","","",',,,
aluminium bronze/silver colour with a coat not less than 15 microns in thickness and
density of 4 mg per square cm etc. including all accessories like handle, sliding >:~;~;:Y;<+.:::;'
door key lock, sliding door wheel, sliding door mohiar, sliding door neoprene, bolts
and nuts including sealants, keeping provision for fitting Smm thick glas~ including
labour charge for fitting of accessories, making groovec; and mending good
damages, carriage, and electricity complete in· all respect as per drawing and
accepted by the Engineer. Size up to: 2100 mm r "'100 mm
/l
PWD SoR 2014 for Civil Works 121
14.5 Supplying, fitting and fixing of Aluminium sliding doors as per the U.S. Architectural
Aluminium Manufacturer's Association (AAMA) standard specification having 1.2 m
mm thick outer bottom (size 75.50 mm, 17.79 mm, 0.528 kg/m), 1.2 mm thick outer
top (size 75. 50 mm, 26.80 mm 0.78 kg/m), 1.2 mm thick shutter top (size 33 mm,
26.80 mm, 0.536 kg/m), 1.2 mm thick shutter bottom (size 60 mm, 24 mm, 0.736
kg/m), 1.2 mm thick side (size 75.50 mm, 19.90 mm, 0.616 kg/m) , 1.2 mm thick
sliding fixed sKfe (31 mm, 26 mm ,'0.422 kg/m) 1.2 mm thick shutter lock (size 49.20 .
mm ,26.20 mm ,0.661 kg/m), 1.2 mm thick inter lock (size 34.40 mm, 32.10 mm,
0.665 kg/m) 1.2 mm thick shutter divider (size 31.75 mm, 0.535 kg/m) and 1.4 mm to
1.5. mm thick spandrel (7.14' mm, 0.70 kg/m) sections all aluminium' members (total
weight 19.72 kg) will be anodized to aluminium bronze/silver colour with a coat not
less than 15 microns in thickness and density of 4 mg per .square cm etc. including
all accessories like sliding door key lock, sliding door whee , sliding door mohiar,
sliding door neoprene, bolts and nuts including sealants, keeping provision for fitting
5mm thick glass including labour. charge for fitting of accessories, making grooves
and men~ing good damages, carriage, and electricity complete in all respect as per
drawing and acceptedby the Engineer. Size up to: 1800 mm x 2100 mm
14.6 Supplying, frtting and fixing of Aluminium sliding window as per the U.S.
Architectural Aluminium Manufacturer's Association (AAMA) standard specification
having 1.2 mm thick outer bottom (size 75.50 mm, 32mm), 1.2 mm thick outer top
(size 75.50 mm, 16.80 mm), 1.2 mm thick shutter top (size 33 mm.26.80, 22 mm),
1.2 mm thick shutter bottom (size 60mm, 24.40 mm), 1.2 mm thick outer side (size
/.".
75.50 mm,19.90 mm), 1.2 mm thick sliding fixed side (size 31 mm, 26 mm),1.2 mm J
thick shutter lock (size 49.20 mm 26.20 mm) and 1.2 mm thick inter lock (size 34.40
mm, 32.10 mm) sections all aluminium members (total weight kg/sqm) will be
anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc. including all accessories like
sliding door key lock, sliding door wheel, sliding door mohiar, sliding door neoprene,
bolts and nuts including sealants, keeping provision for fitting 5 mm thick glass
including labour charge for fitting of accessories, making grooves and mending good
damages, carriage, and electricity complete in all respect as per drawing and
accepted by the Engineer.
14.6.1 Size up to: 1500 mm x1400 mm. (total weight minimum 9.081 kg)
14.6.2 Size up to: 900 mm x 1400 mm (total weight minimum 7.409 kg)
~ ~/
PWD SoR 2014 for Civil Works 122
14.7 Supplying, fitting and fixing of Aluminium sliding composite window with
mosquito mesh as per the U.S. Architectural Aluminium Manufacturer's Association .
(AAMA) 'standard specification having 1.2 mm thick outer bottom (size 95.00 mm, 38
mm, 0.870 kgfm) , 1.2 mm thick outer top (size 95.00 mm, 28.50 mm, 0.97kg/m), 1.2
mm thick shutter top (size 33 rnm, 26.80 mm, 22 mm, 0.536 kg/m), 1.2 mm thick
shutter bottom (size 60 mm, 24.40 mm, 0.736 kg/m), 1.2 mm thick outer side (si~e
95.00 mm, 19.50 mm, 0.738 kg/m), 1.2 mm thick shutter lock (size 49.20 mm, 26.2
mm, 0.661 kg/m), 1.2 mm thick shutter lock (size 34.40 mm, 32.10 mm, 0.665 kg/m), .
1.2 mm thick mesh section (size· 42.20 mm, 13.20 mm 0.460 kg/m), all aluminium
members (total weight 12.79 kg) will be anodized to aluminium bronze/silver colour
with a coat not less than 15 micron in thickness and density of 4 mg per square cm
etc. including all accessories like sliding door key lock, sliding door wheel, sliding
door mohiar, sliding door neoprene, bolts and nuts including sealants, keeping
provision for fitting fiber mesh including labour charge for fitting of accessories,
making grooves and mending good damages, carriage, and electricity complete in
all respect as per drawing and accepted by the Engineer.
'\
PWO SoR 2014 for Civil Works 123
14.8 Supplying, fitling and fixing of Aluminium fixed composite window C1S per the U.S.
Architectural Aluminium Manufacturer's Association (AAMA) standard specification :
having 1.2 mm thick outer bottom (size 75;50 mm, 32 mm, 0.695 kg/m), 1.2 mm thick
outer top (size 75.50mm, 26.80 mm, 0.78 kg/m). 1.2 mm thick shutter top (size 33
mm, 26.80 mm, 0,536 kg/m), 1.25 mm thick shutter bottom (size 60 mm, 24.40 mm,
0.736 kg/m) , 1.2 mm thick outer side (size 75.50 mm, 19.90 mm, 0.616 kg/m), 1.2
mm thick sliding fixed side (size 31 mm, 26 mm, 0.422 kg/m), 1.2 mm thick shutter
lock (size 49.20 mm, 26.20 mm, 0.661 kg/m), 1.2 mm thick interlock (size 34.40 mm,
32.10 mm 0.665 kg/m) 1.2 mm thick bottom cover (size 37.78 mm, 31.78 mm, 0.313
kg/m), 1.2 mm thick grouve cover (76.20 mm, 38.10 mm, 0.912 kg/m) , 1.2 mm thick
grouve cover (size 57.15 mm, 15.80 mm, 0.452 kg/m) and 1.2 mm thick top and side
(size 76.20 mm, 38.10 mm, 0.3 kg/m) sections all aluminium members (total weight
12.297 kg) will be anodized aluminium bronze/silver eplour with a coat not less than
15 micron in thickness and density of 4 mg per square em etc. including all
accessories like sliding door key lock, sliding door wheel, sliding door mohiar, sliding
dopr neoprene. bolts and nuts including sealants, keeping provision for fitting 5 mm
thick glass including labour charge for fitting of accessories, making grooves and
mending good damages, carriage, and electricity complete in all respect as per
drawing and accepted by the Engineer. Size up to: 1500mm x 2100 mm.
14.9 Supplying, fitting and fixing of Aluminium top hung/casement windows as per the
U.S. Architectural Aluminium Manufacturer's Association (AAMA) standard
specification having 1.2 mm thick casement outer {size 38.86 mm, 36.36 mm,
0.395kg/m), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm, 0.692 kg/m),
and 1.245 mm thick shutter glass clip (size 15.87 mm, 27 mm, 0.188 kg/m) sections
of all aluminium members will (total weight 7.584 kg) be anodized to aluminium
bronze/silver colour with a coat not less than 15 micron in thickness and density of 4
mg per square cm etc. including all accessories 4-bar hinge, casement handle, bolts
and nuts keeping provision for fitting 5 mm thick glass including labour charge for
fitting of accessories, making grooves and mending good damages, carriage, and
electricity complete in all respect as per drawing and accepted by the Engineer.
14.10
Supplying ~tting and fixing of Aluminium corrugated curtain wall as per the U.S.
Architectural Aluminium Manufactur&, .; Association (MMA) standard specification'
having 1.2 mm thick bottom cover (size 37.78 mm 31.78 mm, 0.313 kg/m), 1.2 mm .
thick grouve cover (size 76.20 m 38.10 mm, 0.912 kg/m) , 1.2 mm thick grouve cover
(size 57.15 mm, 15.80 mm 0.45 kg/m), 1.2mm thick top and side (size 76.2 mm,
57.15 mm, 0.1"53 kg/m) and 1.8 mm thick spandrel (7.14 mm, 0.70 kg/m) sections of .··.',·,.···,'. . ·. ,.-;·i.. ···:.. ·..
all aluminium members will be anodized to aluminium bronze/silver colour with a coat
not less than 15 micron in thickness and density of 4 ~" square cm etc. including all .
accessories like rivet, screws fixed neoprene etc. complete in all respect as per
drawing and accepted by the Engineer.
PWD SoR 2014 for Civil Works 124
'14.11 Supplying fitting and fixing of Aluminium fixed fan light as per the U.S. Architectural
Aluminium Manufacturer's Association (AAMA) standard specification mm, 0.313
kg/m) 1.2 mm thick bottom cover (size 76.2 mm, 38.10 mm, 0.76 kgfm) and 2.5 mm
thick grouve cover section (size 57.15mm, 15.80 mm, 0.425 kg/m) and 1.2 thick top
and side section (76.20 mm, 16 mm, 38.10 mm, '0.961 kg/m) fixed with above
mentioned frames and all aluminium members (Total weight 5.365kg) will be
anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square cm etc; including all accessories,
neoprene, sealant, nut and bolt etc. complete in aI/ respect as per drawing and
accepted by the Engineer.
14.12 Supplying fitting and' fixing of Aluminium fIXed louver as per the U.S. Architectural
Aluminium Manufacturer's Association (AAMA) standard specification having 1.2mm .
thick wall frame (size 76.20 mm,·38.10 mm, 0.707 kg/m), 5 mm thick louver section
(size 55.02 mm, 37.39 mm, 0.22kg/m) and 2.50 mm thick louver outer section (size
39.67 mm, 15.06 mm, 0.265 kg/m) and inner inclined aluminium louver section fixed
with above mentioned frame and all aluminium members (total weight 7.992 kg) will
be anodized to aluminium bronze/silver colour with a coat not less than 15 micron in
thickness and density of 4 mg per square' cm etc. including all accessories,
neoprene, sealant, nuts and bolts etc. complete in all respect as per drawing and
accepted by the Engineer.
14.13 Supplying, fitting, fixing of Aluminium sliding fly proof Netting shutter as per the Tk. 2,069.00
_.i
U. S. Architectural Aluminium' Manufacturer's Association (AAMA) standard )
specification having 1.2mm thick 38mm x 18mm aluminium outer frame, 1.2mm thick
38mm x 12mmmosquito net shutter frame (mesh section).AII aluminium members
(total weight 12.79 kg) will be anodized to aluminium SS! bronze/silver colour with a
coat not less than 15 micron in thickness and density of 4 mg per square cm etc.
including all accessories like wheel, sealent, rubber, bolts and nuts keeping provision
for fitting fiber mesh including labour charge for fitting of accessories, making
grooves and mending good damages, carriage, and electricity complete in all
respect as per drawing and accepted by the Engineer.
14.14 Supplying, fitting and fixing in Aluminium door frames, windows, partitions and
curtain wall distortion free glass of approved quality and shade including cost of
fitting fixing all necessary accessories etc. complete in all respect as per drawing and
accepted by the Engineer.
14.15 Supplying, fabrication and Installation of Approved colour (4 mm thick) Aluminium Tk. 5,994.00
composite panel (Alucobond/AlcopaneIlAlpolic) as per US Architectural Aluminium
Manufacturer's Association (AAMA) in column, beam and wall surface providing with
44 x 44 x 1.5 mm aluminum section including supply of necessary hardwares,
, consumables, scaffolding etc. fitted with necessary accessories like rivet, screw,
Rowel bolt etc. all complete in all respect as per drawing and direction of the
Engineer in charge.
r
14.16 Supplying. fitting and fixing of aluminium curtain wall with aluminium top Tk. '8,238.00
hung/casement windows as per the US Architectural aluminium Manufacturer's
Association (AAMA) Standard Specification having 100 mm , 50mm, 2mm curtain
wall sub-mullim outer and inner frame, 15 mm thick casement outer frame (size
38.86 mm 36.6mm), 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2
mm thick shutter glass strips, all aluminium member Will be powder coated with coal
not less than 1.5 micron in thickness including all accessories 4 bar hinge casement
handle, 50 m x 50mm x' 6m aluminium angle, steel rowel bo~t, screws , rivets norton.
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect
as per drawing and direction of the Engineer in charge.
14.17 Supplying, fitting and fixing of aluminium ·curtain wall and aluminium top Tk. 6,901.00
hung/basement windows ad per the US Architectural aluminium Manufacturer's .'
Associaticn (MMA) Standard Specification having 50 mm, 50mm, 2mm curtain wall
sUb-mullim outer and inner frame, 15 mm thick casement outer frame (size 38.86
;" -; 36.6mm)., 1.9 mm thick casement shutter (size 47.62mm, 28.57mm,) 1.2 mm
thick shutter glass strips, all aluminium member will be powder coated with coal not
less than 1.5 micron in thickness including all accessories 4 bar hinge casement ',,'}:;:,.·;">I':.',:::,'<:','C<,·,
handle, 50 m x 50mm x 6m aluminium angle. steel rowel bolt, screws , rivets norton :;,:·,:<".:;'i;:.<i():<':',:
tape masking tape, structural sealant, gum bracket rod etc. all complete in all respect
as per drawing and direction of the Engineer in charge .
@{.
PWD SoR 2014 for Civil Works 126
15.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to Tic 214.00
wall both inner-and outer surface, finishing the comer and edges including washing
of sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-Ii/A-M). Ground floor.
15.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing Tk. 246.00
to plinth wall (1:4) with cement up to 150 mm below ground level with neat cement
finishing including washing of sand, finishing the edges and corners and curing at
least for 7 days, cost of water, electricity and other charges etc.· all complete in all
respect as per drawing and accepted by the Engineer. (Cement: CEM-II/A-M)
Ground floor.
15.3 Minimum 12 mm thick cement sand (F .M. 1.2) plaster with ·neat cement finishing Tk. 263.00
to dado (1:4) with cement up to ·150 mm with neat cement finishing including
washing of sand, finishing the edges and Corners and curing at least for 7 days, cost
of water, electricity and other charges etc. all complete in all respect as per drawing
and accepted by the Engineer. (Cement: CEM-IIIA-M). Ground floor.
15.4 Minimum 12 mm thick cement sand· (F .M. 1.2) plaster (1 :6) having with fresh Tk. 198.00
cement to wall both inner-and outer surface, finishing the corner and edges including
washing of sand cleaning the surface, scaffolding and curing at least for 7 days, cost
of water, electricity and.other charges etc. all complete in all respect as per drawing
and accepted by the Engineer.(Cement: CEM-IIIA-M)Ground floor.
15.5 Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to TI(",- 186.00
--.~--.-.- .. '----
ceiling R.C.C. columns, beams, surface of st~ir case,· sunshades, cornices, railings,
drop wall, louvers, fins and finishing the corners and edges including washing of .
sand cleaning the surface, scaffolding and curing at least for 7 days, cost of water, '
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-Ii/A-M). Ground floor.
15.6 Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:3) with fresh cement to Tk. 191.00
ceiling R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings,
drop wan, louvers, fins and finishing the corners and edges including washing of
sand cleaning the surface, sc!)ffolding and curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A-M). Ground floor.
15.7 Flush pointing to brick wall with cement sand (F .M. 1.2) mortar (1 :2) with cement Tk. 117.00
including raking out the joints, and necessary scaffolding curing at least for 7 days,
cost of water, electricity and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer. (Cement: CEM-li/A-M). Ground floor.
15.8 Rule pointing to brick wall with cement sand (F.M. 1.2) mortar (1:2) with fresh Tk. 149.00
cement and raking out the jOints, scaffolding, curing at least for 7 days, cost of water,
electricity and other charges etc. all complete in all respect as per drawing and
accepted by the Engineer. (Cement: CEM-II/A·M). Ground floor.
'(
PWD SoR 2014 for Civil Works 127
15.9 Raised or tack pointing work to brick wall with cement sano (F.M. 1.2) mortar Tk. 359.00 ,J
(1:2) with fresh cement minimum 12 x 20 mm in size including raking out the joints "':.",'"''}:«''::':'':;:''..',''' I
and necessary scaffolding, curing at least for 7 days, cleaning each and every brick,
cutting the bricks with pumic stone where necessary etc. all complete in all floors,
cost of water, electricity and other charges etc. all complete in all respect as per
drawing and accepted by the Engineer. (Cement: CEM-IIIA-M) Ground floor.
15.10 Providing drip course or Nosing at the edge of sunshade or cornice with cement Tk. 91.00
sand (F.M. 1.2) mortar (1 :2) with fresh cement including scaffolding, curing at least
for 7 days, cost of water, electricity and other charges etc. all complete in all respect
as per drawing and accepted by the Engineer.(Cement: CEM-II/A-M)Ground floor.
15.11.1 Making groove in plaster on outside wall upto 50mm X 6mm size including Tk. 18.00
scaffolding, curing etc. complete as per drawing and accepted by the Engineer.
15.11.2 Making groove in plaster on outside wall upto 38mm X 6mm size including Tk. 27.00
scaffolding, curing etc. complete as per drawing and accepted by the Engineer..
15.12 Extra rate for plaster and all types of pointing shall be incorporated in the estimate
, 15.12.1 Add for each additional floor up to 5th floor. Tk. 11.00
15.12.2 Add for eaco additional floor from 6th Hoorto 9th floor Tk. 17.00
15.12.3 Add for each additional floor above 9th floor Tk. 22.00
15.13 Average 100 mm thick finished lime terracing with 20 mm down graded first class Tk. 12,015.00
brick chips (Khoa), surki from 1st class·bricks and min lime content 500kg per
2.83cubic meter (stone lime brought at site, not being powdered.in open 'air and to be'
slaked in presence of engineer-in-charge and to be measured in volume three days
after slaking for using in the mix) in the proportion 7:2:2 (brick chips: surki : lime)
including preparation of the mix on the ground by making a suitable platform under
proper polythene cover. Cutting the mix twice daily with limewater (1: 10) at least for 7
days until the mix attain desirable consistency. Laying the mix in proper slope,
beating the same with standard 'koppa' for minimum 7 days to gain maximum
consolidation, making ghoondy and neat finishing with lime Surki mortar (1 :2) and
curing for 21 days providing polythene cover after each day work and cleaning etc.
complete in all respect accepted by the Engineer.
15.14 Pre-cast ventilators of minimum 25 mm thick of any design with cement sand Tk. 1,777.00
(F.M.1.2) mortar (1:4) fitted and fixed in position, finished with cement sand (F.M;
1.2) plaster (1:6) including necessary scaffolding and curing, in all floors accepted by
the Engineer. (Cement: CEM-II/A-M)
15.15 75 x 75 mm cornice of brick masonry in cement sand (F. M. 1.2) mortar (1 :6) having Tk. 174.00
minimum 12 mm thick cement sand (F.M. 1.2) plaster (1 :6) including scaffolding and
curing at least for 7 days in all floors accepted by the Engineer. (Cement: CEM-II/A-
M)
15.16 Supplying, fitting, fixing of broken and sharp ,glass 19 mm to 32 mm height, avo 19 Tk. 211.00
mm width placed at a distance approximately 25 mm center to center spacing,
embedding the same to 12 mm to 19 mm thick cement plaster with neat cement
finishing including necessary scaffolding approved and accepted by the
Engineer.(Cement: CEM-II/A-M)
16.1 White washing by three coats, lime mixture prepared at least 12 hours before use, Tk. 18.00
slacking stone lime, supply of gums, blue, stirring thoroughly, removing the floating
materials from the mixer, surface cleaning to free from a/l foreign materials before
application of each coat, applying one vertical and one horizontal wash for each coat
and successive coat is to be applied after drying up of previous coat including hair
brass, providing necessary scaffolding and cleaning plinth, floors, doors, windows,
portions and ventilators by washing, rubbing, oiling if necessary after white wash for
all floors including cost of water, electricity. and other charges etc. complete in all
respect in all floors and accepted by the Engineer.
16.2 Colour wash with yellow orchard/any other colour pigment by two coats over a Tk. 20.00
prime coat of white wash, lime mixture prepared at least 12 hours before use,
slacking stone lime, supply of gums, blue, stirring thoroughly, removing the floating
materials from the mixer, surface cleaning to free from all foreign materials before
application of each coat, applying one vertical and one horizontal wash for each coat
and successive coat is to be applied after drying up of previous coat including hair
brass, providing necessary scaffolding and cleaning plinth, floors, doors, windows,
portions and ventilators by washing, rubbing, Oiling if necessary after white wash for
all floors including cost of water, electricity and other charges etc. complete in all
respect in all floors and accepted by the Engineer.
16.3 . Cement Paint of approved quality and colour delivered from authorized local agent Tk. , 128.00
of the manufacturer in a sealed container, made from water based powder mixed
with water (1:1), applying first coat, curing the same after six hours for 24 hours,
second coat applied and curing the same for 7 (seven) days etc, taking care and
cleaning the surfac~ .fully from grease, oily substances, old paints, lime wash,
fungus, algae etc., sand papering the surface before applying 1st and 2nd coat,
complete including cost of electricity, water and other changes etc. complete in all
. floors and accepted by the Engineer.
16.4 On exterior surface applying as per manufacturer instructions 3 coat of weather coat Tk. 189.00
of approved quality and colour delivered from authorized local agent of the
manufacturer in asealed container complete in all respect in all floors and accepted
by the Engineer.
16.5 On exposed brick surface applying as per manufacturer instructions in 3 coats Tk. 193.00
silicon based water repellent of approVed quality delivered from authorized local
agent of the manufacturer in a sealed container etc. complete in all respect in all
floors and accepted by the Engineer.
16.6 Painting to door and window frames and shutters in two coats with approved best Tk. 183.00
quality and colour of synthetic enamel paint delivered from authorized local agent
of the manufacturer in a sealed container, having highly water resistant, high
bondibilty, flexible, using specific brand thinner applied by brass/roller/spray over a
coat of priming elapsing time for drying including surface cleaning from dust, oil or
dirt, smoothening, finishing and polishing with sand paper and necessary tools,
scaffolding, testing charges etc. aU complete in all floors approved and ac("c:~ted by ·c··:-:::.:",·:,',·y',':;:n:i·:·
the Engineer.
PWD SoR 2014 for Civil Works 129
16.7 Approved best quality and colour synthetic polyvinyl distemper delivered from Tk. 147.00 ~ I
authorized local agent of the manufacturer in a sealed container, applying to wall and )
ceiling in 2 coats over a coat of brand specified primer or sealer elapsing specified I
time for drying/ recoating matt finish including cleaning and sand papering making
the surface free from loose and flaky materials, dirt, grease, wax, polish, scra.ping all
chalked and scaled materials, applying the paint by brush/roUer and necessary
scaffolding etc. all complete in all floors accepted by the Engineer.
16.8.1 Plastic emulsion paint of approved. best quality and colour delivered from Tk. 159.00
authorized local agent of the manufacturer in a sealed container, applying to wall and
ceiling in two coats over a coat of brand specified primer or sealer elapsing
specified time for drying or recoating including cleaning drying, making free from dirt,
grease, wax, removing all chalked and scaled materials, fungus, mending good the
surface defects, sand papering the surface and necessary scaffolding, spreading by
brush! roller/spray etc. all complete in all floors accepted by the Engineer.
16.8.2 Plastic emulsion paint of approved best quality and colour delivered from Tk. 221.00
authorized local agent of the manufacturer in a sealed container, applying to wall and .
ceiling in two coats over lime putty of specified brand' applied on primer or sealer
elapSing specified time for drying/recoating including cleaning drying, making free
from dirt; grease, wax, removing all chalked and scaled materials, fungus, mending
good the surface defects, sand papering the surface and necessary scaffolding,
spreading by brush/ roller/spray etc.' all complete in all floors accepted by the
Engineer:
Ume putty to be applied as per manufacturer instructions approved and accepted by
the Engiheer.
16.9.1 Acrylic emulsion painting (silky finish) of approved best quality and colour Tk. 162.00
delivered from authorized local agent of the manufacturer, in a sealed container,
applying to wall and ceiling in two coats over a coat of brand specified primer or
sealer including cleaning, drying, making free from IQOse and flaky materials, dirt,
grease. wax, removing all chalked and scaled materials, fungus, elapsing specified
r
time for drying, re-coating, flaking paints, mending good the surface defects, sand
papering the surface, smoothing by putty and necessary scaffolding, testing charges, .
applied by brush/roller/spray etc. all complete in all floors accepted by the Engineer.
16.9.2 Acrylic emulsion painting (silky finish) of approved best quality and colour Tk. 218.00
delivered from authorized local agent of the manufacturer in a sealed container,
applying to walland ceiling in two coats over lime putty of specified brand applied
on primer or sealer elapsing specified time for drying/recoating including cleaning
drying, making free from dirt, grease, wax, removing all chalked and scaled
materials, fungus, mending good the surface defects, sand papering the surface and
necessary scaffolding, spreading by brush/ roller/spray etc. all complete in all floors
accepted by the Engineer.
16.10 omitted
16.11 omitted
16.12 Textured paint of approved best quality and colour delivered from authorized local Tk. 578.00
agent of the manufacturer in a sealed container, applying to wall and ceiling
including cleaning, drying. making free from dirt, grease, wax, removing all chalked
and scaled materials, fungus if required must be treated with fungicidal solution,
flaking paints. mending good the surface defects, sand preparing the surface and
necessary scaffolding, applied by. brush/roUer/spray etc. all complete in all floors
accepted by the Engineer.
\"
~ ~
PWD SoR 2014 for Civil Works 130
16.13 Chlorinated rubber paint of approved quality and colour delivered from authorized Tk. 306.00
local agent of the manufacturer in a sealed container, applying to concrete surfaces
and walls in three coats elapsing specified time for drying and re-coating including
cleaning, drying, making free frpm dirt, grease, wax, removing all chalked and scaled
materials, fungus (if required must be treated with fungicidal solution) flaking paints,
washing the surface with soap water/caustic· soda, mending good the surface
defects, smoothening the surface by putty sand papering the surface and necessary
scaffolding, applied by brush/roller/spray etc. all complete in all floors and accepted
by the Engineer.
16.14 French polishing to door and window frames and shutters three coats over a coat TIc 293.00
of priming. including putty, cleaning finishing and polishing with sand paper etc. all
complete in all floors accepted by the Engin~er.
16.15 Wood varnishing of approved quality and colour delivered from authorized local
agent of the manufacturer in a sealed container using brand specified thinner to door
and window frame and shutter in three coats, applied with brush including cleaning
oil, grease, dirt, making dry, sand papering, if required washing with weak detergent
solution, stripping out the colour straps, finishing the surface, etc. all complete in all
floors accepted by the Engineer.
.)G;vu/ .
PWD SoR 2014 for Civil Works 131
17.1 Constructing surface drain of 300 mm clear width and depth up to 300 mm in Tk. 1,167.00
brick masonry with 125 mm thick.check wall in cement sand (F.M. 1.2) mortar (1:6)
over avo 75 mm thick cement concrete base (1 :3:6) over one layer of brick flat soling.
The surface having minimum 12 mm thick 'Cement sand (F.M. 1.2) plaster (1 :3) and
neat cement finishing with cement curing at least for 7 days including excavation in .
a" kinds of soil,· backfilling with fine sand (F.M. 0.8), consolidating and dressing, cost
of water, electriCity, other charges etc. complete and accepted by the Engineer.
(Cement CEM-"/A-M)
17.2 Constructing surface drain of 600 mm (av.) depth and 225 mm clear width at Tk. 2,340.00
the bottom and 525 mm at the top having 125 mm thick cement concrete (1 :2:4) curb
up to 300 mm from the bottom over one layer of polythene on top brick flat soling and
the side slopes of the remaining 300 mm height provided with 125 mm thick first
class brick work in cement mortar (1:6) including minimum 12 mm thick cement sand
(F.M. 1.2) plaster (1 :3) including neat cement finishing the surfaces and back of the
drain up to 150 mm below ground level with fresh cement (conforming to 80S 232)
curing at least for 7 days including excavation of all kinds of soil, back filling with fine
sand (F.M. 0.8) consolidating and dressing, including cost of water, electricity, other .
charges etc. complete and accepted by the Engineer. (Cement: CEM-"/A-M)
17.3 Providing apron with 50 mm thick cement concrete (1 :2:4) with cement, coarse sand Tk. 832.00
and picked jhama chips including breaking chips and one layer brick flat soling at
bottom with first class or picked jhama bricks including cutting earth· for preparation
of bed and filling the interstices with local sand (F.M. 0.8) including finishing,
.dressing, curing at least for 7 days etc. all complete, including cost of water,
electricity, other charges accepted by the Engineer. (Cement: CEM-II/A-M)
17.4.1 Supplying, laying, fitting' fixing best quality 225·mm dia(internal) machine made . Tk. 911.00 ~/
R.C.C. pipe over 100 mm thick cement concrete (1 :3:6) at base and sides including
single brick flat soling and gasket with cement mortar (1:4) joints, cutting and filling
trenches up to required depth including excavation of soil etc. all complete in all
respects as per type plan and accepted by the Engineer (average depth of trench is
W
3'-6 (Cement: CEM-II/A-M)
).
17.4.2 do- with 300 mm dia (internal) R.C.C. pipe. Tk. 1,188.00
17.5 Supplying, laying and fitting-fixing 900 mm dia ReC pipe of approved quality and Tk. 9,661.00
accepted by the Engineer. [Rate is excluding cost for excavation, back-fill, materials
for back-fill and bedding]
t,
PWD SoR 2014 for Civil Works 132
18.1.1 Supplyirig, fitting and fixing plain particle board complying unit wt 499 to Tk. 2,674.00
550kg/m 3 ,bending strength 0.35N/mm2 , max swelling 8% , moisture content not
more than 10% I for ceiling of 12 mm thick with best quality and well seasoned
Garjan wood fraille of section 75 x38 mm at 600 x 600 mm in grid suspended from
ceiling or roof or beam by 12 SWG double ply G.I. wire fixed to the ceiling by rowel
plug, screws, hooks, nails etc. maintaining straight lines and desired finished level at
bottom face with vertical strut as required including cutting holes in slabs or beams
by electric drill machine and mending good the damages, if any,. during execution of
the work including cost and carriage of all materials, accessories, labour for
installation, electricity charge, scaffolding, screws, nails etc. including. painting 2
coats over acoat of priming with best quality and approved colour synthetic enamel
as per item no 16.6 of this schedule of etc. all complete as per drawing design and
accepted by the Engineer. (All sizes of wood are finished)
18.1.2 Supplying, fitting and fixing plain particle board as in itme 18.11 for ceiling of 12 Tk.
mm for auditorium and other type of tall structures beyond 4 m up to 8 m,
which do not c<;lVer the above item [Item No. 1S3(a)J. Description of item is the same
as in item No. 153(a) above.
18.1.3 Supplying, fitting and fixing of ceiling with 12 mm thick melamine board laminated Tk. 1,522.00
by mechanical hot press with a milk white PVC membrane in aluminium frame
suspended from ceiling.
18.2.1 Supplying, fitting and fixing gypsum board ceiling of 9 mm thick board laminated by Tk. 1,692.00
mechanical hot press with a milk while PVC membrane with Aluminium T-bar frame
in natural anodized finish at 600 x 600 mm in grid suspended from ceiling by 12
SWG double ply wire fixed to Ihe ceiling by rowel plug, screws, hooks, nails etc.
maintaining straight lines' and desired finished level a bottom face with vertical
wooden strut as required including making holes in slabs, or beams by electnc drill
machine; and mending good the damages, if any, during execution of the work
including cost of all materials, electriCity, accessories, scaffoldings, labour for
installation, screws, nails, etc. all complete as per drawing, design and accepted by
the Engineer.
18.2.2 - do - with 12 mm thick veneered board ceiling. Tk. 1,962.00
18.2.3 Supplying, fitting and fixing of'9 mm thick perforated gypsum board false ceiling . Tk. t,751.00
with aluminium T bar frame in natural anodized frame at 600 mm x 600 mm grid
suspended from ceiling by 12 SWG double ply G./. Wire
18.3.1 Supplying,fitting and fixing 12 mm thick Burma Teak (8T) Veneered board in Tk. 3,379:00
walling with best quality and well seasoned Garjan wood frame of section 75 x 38
mm at 600 x600 mm in grid, fitted and fixed to wall by plugs, nails, screws etc.
including treatment of inner surface with termite and damp proofing agent .
maintaining leveled and finished exposed faces including. making holes in wall and
mending good the damages. If any, during execution of the work including. cost and
carriage of all materials, electricity, accessories, labour for installation, scaffolding,
screws, nails etc. including French polishing 3 coats over a coat of priming as per
item No. 137 of the schedule etc. all complete as per design, approved sample and
accepted by the Engineer.
18.3.2 - do - 12 mm thick particle board walling Tk. 2,360.00
19.1.1 Manufacturing, supplying, fitting and fixing collapsible gate of any design and Tk. 3,531.00
shape made of 3/411 x 3/4" x 1/8" channel placed @ 112 mm clc vertically and
connecting the same with each other by 20 x 3 mm M.S flat bar scissors 525 mml
600 mm long provided in 3 rows including cutting the different M.S. members to
required sizes, fabricating, welding, riveting with required size rivets, providing
required size wheels, pulling. handles on both sides, suitable locking arrangement,
electrodes, grease and finally placing the same in position in between 2 (two) Nos.
50 x 50 x 6 mm M.S. Tee rail made by welding 2 Nos. 50 x 6 mm M.S. flat bar fitted
and fixed at top and bottom with R.C.C. lintel/roof slab, floors and side wall with
required Nos. 150 mm to 225 mm long 38 x 6 mm M.S. flat bar clamps one end
welded with the gate member and the other end bifurcated and embedded in C.C. at
the respective point including cutting 'holes and mending good the damages by
pouring concrete (1:2:4) into the holes and· finishing, etc complete, 'painting 2 (two)
coats with approved best quality synthetic enamel paint over a coat of anticorrosive
painting, both end carriage, including greasing, electrodes, curing etc. complete as
per drawing and design and accepted by the Engineer.
. (Rate is excluding the cost of paint).
19.1.2 -do- -do- Collapsible gate made of 3/4" x 3/4" x 1/8" M.S. angle as vertical member Tk. 4,045.00
and'314" x 1/8" F.I bar as scissors.
. 19.1.3 -do- -do- Collapsible gate made of 1" x1" x 1/8" "..S. angle as vertical member and Tk . 4,876.00
1" x 1/8" F.I bar as scissors.
Tk. 5,756.00
"
19.2.1 Supplying, fitting, fixing, and installation of ordinary type M.S. gate (double leaf) of
any design and shape with 38 x 38 x 6 mm M.S. Ang.le outer frame having 16 mm
dia M.S. rod placed vertically @75 mm c/e. at bottom part and top part (arrows) and
also placed horizontally at boltom for interconnection of 16 mm dia M.S. rod placed
vertically as per design, the top part covered with 18 BWG M.S. sheet and fixed with
4 Nos. 38 x 6 mm F.1. bars placed diagonally and 4 Nos. 38 x 6 mm F.I. bars placed
horizontally and ve~ic"ally all passing through the center, providing locking
arrangements on 3 mm thick M.S. plate one for main gate and one for minimum 300
x 1025 mm pocket gate with 38 x 38 x 6 mm M.S. angle and 16 mm dia M.S. rod
placed vertically @ 75 mm cle, providing 38 x 38 x 6 mm M.S. angle clamps fitted
and fixed with the outer frame ofthe main gate, the clamp being embedded in R.C.C.
or R.C.C. core pillar with cement concrete (1:2:4) in masonry including 'cutting holes
and mending good the damages, finishing, curing etc. including riveting, welding as
and where necessary, painting two .coats with approved qualny of synthetic enamel
paint over a coat of priming of anti-corrosive paint etc. all complete as per drawing,
design and accepted by the Engineer. (Rate is excluding the cost of paint),
19.2.2 Manufacturing, supplying and fitting-fixing security door with 7/8" dia M.S, rod and Tk. 10,070.00
as
outer frame with 2" x 2" x %" M.S. angle complete per drawing and accepted by
the Engineer.
r'
~
PWO SoR 2014 for Civil Works 134
19.3 Supplying, fitting, fixing, and installation of ordinary type M.S. security gate of any Tk. 5,007.00
des~n and shape with 50 x 50 x 6 mm M.S. angle outer frame and two 50 x 50 x 6 .
mm angle placed diagonally having 22 mm dia M. S. rod placed vertically @ 115 mm
c/c. and also 38 x 6 mm F.I placed horizontally, the bottom part covered with 3 mm
thick M.S. sheet providing locking arrangements on 3 mm thick M.S. plate providing
heavy type clamps fitted and fixed with the outer frame of the main gate, the clamp
being embedded in R.C,C. or R.e. core pillar with cement concrete (1 :2:4) in
masonry including cutting holes and mending good the damages, finishing, curing
. etc. including fabrication, riveting, welding as and where necessary, etc. all complete
as per drawing, design and accepted by the Engineer.
19.4 Supplying, fitting, fixing and installation ordinary type M.S. gate (double leaf) of Tk. 7,991.00
any des~n and shape with 38 x 38 x 6 mm M.S. angle box (made by welding 2 Nos.
38 x38x 6 mm angle) outer frame having 25 x 50 x 25 x 5 mm M.S. channel (made
by welding 2 Nos. of angle) placed part diagonally after cutting and shaping as per.
requirement part horizontally @ 75 mm C/C the two part of each leaf being
separated by a vertical member of 38 x38 x 6 M.S. box and welded the each ends of
diagonal and horizontal members properly with the box frame as per architectural
drawing providing full locking arrangement on 3 mm thick M.S. plates providing 38 x
38 x 6 mm M.S. angle clamps, fitting fixing with the outer frame of the gate the
clamp being embedded in R.C.C. pillars with cement concrete (1:2:4) including.
cutting holes and mending good the damages, finishing, curing and where necessary
painting two coats with approved quality of synthetic enamel paint over a coat of
priming of anticorrosive paint etc. a" complete including making and providing 50 x 6
mm M.S. rail and 38 mm wheel for smooth movement of the gate etc. all co~plete as
per drawing, design and accepted by the Engineer. [Rate is excluding the cost of
painting]
19.5 Manufacturing, supplying, fitting and fixing G.I. pipe gate of any design and shape Tk. 9,307.00
having 38 mm dia G.I. pipe outer frame and 19 mm dia. G.I. pipe vertical member
placed @75 mm C/C by welding at top and bottom of G.I. pipe frame, cutting the
pipes in proper shape and size including making semicircular band at the corners of
the outer frame without damaging the pipe, covering 50% Of. the gate area with 18
BWG M.S. sheet, providing also tWo extra horizontal 38 mm dia G.I. pipes welded .
with vertical post, providing 6 Nos. huskle domney with R.C.C. or R.C.C cere pillar
with cement concrete (1 :2:4) in masonry including cutting holes, mending the
damages, making provision for minimum 0.61 m x 1.4 mpocket gate having its outer
frame and inner vertical members made with 19 mm dia G.!. pipe including
necessary locking arrangements. Painting the gate with 2 (two) coats of synthetic
enamel paint over a coat of anti-corrosive priming, welding as and where necessary
including necessary locking arrangement and providing 2 Nos. 16 mm M.S. socket
bolts etc. all complete as per design and drawing and accepted by the Engineer. ;;,\;'Yh":::/!/'iV/;.
[Rate is excluding the cost of painting]
, l
PWDSoR 2014 for Civil Works 135
19.6 Supplying, fitting and fixing of rolling shutter of any design and shape made of 24 Tk. 5,300.00
SWG G.P. sheet unit minimum 69 mm width having 10 mm and 12 mm dia circular
folding at ends, rolled in machine, locked together properly to form rolling shutter, top
of the shutter to be fitted with circular spring box made of 22 BWG sheet, containing
best quality spring made in China, nutted with 38 mm G.I. pipe at one end and the
other end nutted to shutter including fitting the G.!. pipe again with 375 x 300 x 6 mm
pankha at ends with side guide channel (side channel consist of 50 x 100 ~ 6 mm
M.S. plate with 2 x 19 x 3 mm F.1. bar, middle channel consist of 2 x 150 mm x 6 mm
M.S. plate With 2 x19 mm x6 mm fixed to wall or column with clamps embedded in
R.C.C. part by cement concrete (1:2:4) including cutting holes (minimum 3 x 25 mm
x6 mm) mending the damages, finishing, curing, bottom end of shutter fitted to folded
G.P. sheet '(min 125 mm width in two layers), which is again fitted to 25 x 25 x 3 mm
angle, providing handle with F.I. bar 25 x 6 mm and locking arrangement in both
sides, painting two coats with approved colour and brand of synthetic enamel paint
over a coat· of priming etc. complete in all respect accepted by the Engineer. [Rate is
excluding the cost of painting]
19.7 Manufacturing, Supplying, fitting, fixing of ordinary type M.S. folding gate with Tk. 4,865.00
12mm x 12mm MS square solid bar and 25 mm x 25mm x 6 mm MS Angle box
frame including fabrication, welding, cost of electricity, workshop charges, carriage,
cutting grooves, mending good the damages, finishing, curing etc. including
fabrication, riveting, welding as and where necessary, etc. all complete as per
drawing, design and accepted by.the Engineer.
20.1 Manufacturing, supplying, fitting and fixing stair railing of any standard height of any Tk. 3,273.00
design and shape with square box (2 Nos. in each tread) made by thorough
welding of 2· Nos. 19 x 19 x 3 mm M.S. angle to provide hand-rail, e~graving each
box 150 mm in the concrete by 50 x 50 x 6 mm anchor plate at base welding 38 mm
x6 mm F.I. bar inclined plain with the top of the box to fit in the grooved wooden rail
by necessary screws including cutting grooves in concrete, mending good the
damages with cement concrete (1 :2:4), applying first class polish to hand rail, 2 (two)
coats of synthetic enamel paint of approved quality over a prime coat etc. finished in
all respect for all floors and acc~pted by the Engineer.(Exposed area of railing will be
considered for measurement, rate is excluding cost of hand-rail and cost of painting}.
20.2 Manufacturing, supplying, fitting and fixing stair railing of standard height of any Tk. 6,471.00
design and shape with square box (2 No. box in each tread) made by thorough
welding of 2 Nos. 25 x 25 x 5 mm M.S. angle, engraving each box 150 mm in the
concrete by SOx 50 x 6 mm anchor plate at base welding 50 x 50 x 6 mm F.I. bar in
inClined plain with the top of the box fit in the grooved wooden rail and 2 Nos. 225 x
25 mm finished section of wooden strip fitted and fixed at mid height of railing at both
side of M.S. angle box in inclined plain parallel to the hand rail etc. fitted and fixed by
necessary screws, nails including cutting grooves in concrete mending good the
damages with c~ment concrete (1:2:4) applying 1st class French polish to wooden
hand rail and inclined wooden strip and painting to F.I bar and square box with 2
(two) coats of synthetic enamel paint of approved quality and colour over a prime
coat etc. complete in all respect for all floors and accepted by the Engineer.
(Exposed area of railing will be considered for measurement, rate is excluding cost of
polishing and painting)
20.3 Supplying, fitting and fixing 12 mmdia G.I pipe stair railing of any standard height
of any design and shape with 50 x 50 x 6 mm M.S. plate at the base of 12 mm dia
G.I. Pipe and fitted arid fixed by welding. Placing the pipes vertically @ 125 mm c/c
(1 Nos. in each steps) 150 mm embedded into the R.C.C tread of staircase after
cutting grooves and mending good the damages with C.C. and providing 38 x 6 mm
F.1. bar on the top of G.I. pipe to provide wooden/G.I. pipe hand rail of any design
including polishing painting etc. all complete and accepted bv the Engineer.
(Exposed area of railing will be considered for measurement, rate is excluding the
cost of pain, wood for railing)
20.3.1 With the provision of hand rail of size: 150 x 62 mm (finished) Tk. 1,932.00
20.3.2 With the provision of hand rail of size: 112 x 62 mm (finished) Tk. 2,479.00
20.4 Supplying, fitting and f!xi'lg stainless steel (S5) stair railing of standard height with Tk. 7,008.00
2 mm thick 2.5" dia pipe for hand-rail as per drawing and accepted by the Engineer.
20.5.1 Supplying, fitting and fixing 12 mm dia G.I pipe stair railing of any standard height Tk. 3,467.00
of any design and shape with 50 x 50 x 6 mm M.S. plate at the base of 12 mm dia
G.1. Pipe and fitted and fixed by welding. Placing the pipes vertically @ 125 mm clc
(1 Nos. in each steps) 150 mm embedded into the R.C.C tread of stair case after·
cutting grooves and mending good the damages with C.C. and providing 38 x 6 mm
F.I. bar on the top of G.I. pipe to provide wooden/G.!. pipe hand rail of any design
including polishing paintii19 el\.,. ~II complete and accepted by the Engineer.(Exposed
area of railing will be considered for measurement, rate is excluding the cost of pain,
wood for railing}
\
)~
PWD SoR 2014 for Civil Works 137
20.6 Supplying, fitting and fixing verandah railing with 2mm thick 50 mm, 25 mm and 20 Tk. 11,391.00
mm diameter stainless. steel pipes as per approved design and accepted by the
Engineer.
20.7 Providing noising to the Nose of tread of stair including supplying 3 Nos. of 75 mm
long 12 mm x 3 mm F.I. bar clamp with bifurcated ends in each treads including
fitting and fixing with the angle by welding including fitting and fixing the angle by
cutting grooves in R.C.C, fixing and finishing and the same with C.C. (1:2:4) etc. cost
of electricity all complete and accepted by the Engineer.
20.7.1 Providing 1.5" x 1.5" x 1/4" M.S. angle to the nosing of steps of staircase Tk. 376.00
20.7.2 Providing nosing 1.25" x 1.25" x 1/4" M.S. angle to the nosingof steps of stair case. Tk. 325.00
20.7.3 Providing 1" x l' X 1/4" size M.S. angle to the nosing of stair case. Tk: 276.00
20.7.4 Providing 1.5" x 1.5"·x 1/4" brass angle to the nosing of steps of stair case Tk. 1,206.00
\ ,
PWD SoR 2014 for Civil Works 138
21.1 Supplying, fitting and. fixing steel grill fencing in boundary wall of any design and Tk. 1,929.00
shape with 31 x 6 mm F.I. bar @150 mm c/c placed vertically after cutting as per·
required measurement. Welding the said F.I. bar with 2 Nos. horizontal 30 x 6 mm
F.I. bar placed one at top and another at bottom including embedding/fixing the
horizontal F.I. bar in position including cutting grooves in wall up to 150 mm depth
and mending good the damages with C.C. (1 :2:4) finished with two coats of painting
with synthetic enamel paint over acoat of anti-corrosive painf etc. complete as per
drawing and design and accepted by the Engineer. (Rate is excluding the cost of
painting)
21.2 Supplying, fitting and fixing steel grill fencing of any design and shape made with Tk. 4,470.00
19 mm x 3 mm tube (angle box made with 2 Nos.19 x 19 x 3 mm angle in by
continuous welding) placed vertically @ 150 mm clc and welding the said vertical
boxes with two Nos. horizontal 25 x 25 x 6 mm angle box (made with 2 Nos. 25 x 25
x6 mm angle by welding), placing one at bottom and another at top and again fitted
and fixed by welding the said horizontal tube box (with vertical 38 x 38 x 6 mm angle
box post made with 2 Nos. 38 x 38 X 6 mm angle by welding) provided 1800 mm clc
including embedding the tube box post in brick R.C.C. pillar or core wall up to 375
mm depth after cutting grooves in wall/pillar including mending good the damages
with C.C. (1 :2:4) and finishing, curing, 2 coats of approved synthetic enamel paint
over a coat anti-corrosive paint etc. all complete as per design, drawing and
accepted by the Engineer.(Rate is excluding the cost of painting)
21.3 Manufacturing, supplying, fitting and fixing M.S. grill fencing as per design with Tk. 2,238.00·
outer frames having 38 x 38 x6 mm M.S. angle and inner members having 6 mm dia
M.S. rodplaced @ 110 mm cle diagonally on both direction, welding each cris-cross .
end· of rod with corners of outer frame including cutting rods and size angles to .
required shapes and size and setting the entire fence with the previously installed
tube (angle box) post including thorough and full welding the frame with the angle
box posts, paintirig 2 coats of synthetic enamel paint over a coat of anti-corrosive
priming etc. all complete as per drawing and accepted by the Engineer.
(Rate is excluding the cost of angle box post and its installation and excluding the
cost of paint)
21.4 Manufacturing, supplying, fitting and fixing M.S. tube (angle box) post (bottom end Tk. 932.00
bifurcated) made by thorough welding of two Nos. 38 x 38 x 6 mm M.S. angle and
vertically placing the post into C.C. or R.C.C. foundation including cutting angle to
required shape and size including covering the top of the post with 6 mm thick M.S.
plate etc. all complete as per drawing. (Rate is excluding the cost of C.C.lR.C.C.
foundation and paint)
21.5 Providing barbed wire fencing with R.C.C (1 :2:4) pillars @ 2.43 m c/c. and of Tk. 139.00
section 100 mm x 100 mm at top and 150 mm x 150 mm at bottom of 2.13 m total .
height (1.37 m above G.l. and 0.76 m be ' -··' G.L.) including 150 mm thick, 450 mm
square spread footings (pillars reinforced with 4 Nos. 10 mm dia main rod and 6 mm .
dia stirrups @ 150 mm clc, footing reinforced with 5 Nos. 10 mm dia rod both ways)
supplying, fitting and fixing 8 lines of barbed wire horizontally (fixed with the post
through 6 mm dia, rods embedded in to the post) and 2 lines diagonally from post to
post with 12 BWG 2 ply barbed wire, with 4 points barbs @ at least 112 mm c/c
including 6 mm thick (1 :4) cement plaster up to 1500 mill length of the pillars etc.
complete and accepted by the Engineer. (Rate is excluding !tIe cost of concrete and
reinforcement which is to be paid as per corresponding items in the schedule)
.(!{
PWD SoR 2014 for Civil Works 139.
21.6 Providing.barbed wire fencing with average 100 mm dia best q.uality local bullah ·. ,·. .:,:c:.••~"f.,u. Tk. 240.00 .. I
post of 1.98 m total height (1.37 m above G.L. and min. 0.60 membedded in the
ground) placed at 1800 mm clc with 9 Nos. horizontal lines and 2 Nos. diagonal lines
of 12 BWG 2 ply barbed wire with 4 pOints barbs @at least 112 mm c/c in each way
of 1.8 m .including embedded the post tightly in ground and p'roviding a cement
concrete base of 200 x 200 x300 mm around ballah at E.G.L, stretching the wires
and fixing with the post with the help of minimum 62 mm long G.I. nails including
supply of all materials etc. aU complete and accepted by the Engineer.{Rate is
excluding the cost of ballah and its driving/fixing and concrete which is to be paid as
per corresponding items in the schedule)
21.7 Supplying, fitting and fixing 12 BWG barbed wire (2 ply, 4 points) in fencing work Tk. 760.00
@150 mm clc in both horizontally and vertically, supported by 38 x 38 x 6 mm
M.S. angle post (300 mm embedded in R.C.C. or in brick work with a cement
concrete base of 75 x 75 x 300 mm) 600 mm vertical and 450 mm inclined or as per
requirement @ 2.4 m. cle including straightening, binding the joints with 18 BWG wire
making holes in the angle etc. in /e supplying of all necessary materials complete in
all respect and accepted by the Engineer. (Rate is excluding the cost of R.C.C or
brick work or C.C. which iS'to be paid as per corresponding items in the schedule)
22.1 Supplying, fitting and fixing wooden wedge instead of putty by 12 mm x 12 mm- Tk. 54.00
(base x height) for fixing glass panes with wooden frame by nails or by any other
approved method including the cost of necessary wood, painting/polishing, nails ·etc.
and excluding the cost of wooden frame, and painting and 5 mm thick glass panes all
complete and accepted by the Engineer.
22.2 Supplying, fitting and fixing of 20mm dia foreign made aluminium pipe curtain rail Tk. 552.00
for door and window including cutting and fitting fixing as per required measurement
and supplying necessary screws, electric drill and rowel plug including charge of
electricity etc. complete and accepted by the Engineer.
22.3 Supplying, fitting and fixing 10mm thick clear ~empered glass door including all Tk. 13,075.00
accessories 1 set maintenance auto closed special quality 2 nos clamping device, 1
set locking device, top ~inge and handle etc. complete in all respect as per drawing
and direction of the Engineer in Charge.
22.4 Supplying, fitting and fixing 10mm thick clear glass partition with 44mm, 44mm,. Tk. 3,238.00
1.5mm aluminium box, protector bit (single), protector bit (double) in/c all accessories
etc. all comp.lete and as per drawing and direction of the Engineer in Charge.
22.5 Supplying, fitting and fixing of C.T wood strip (62 x 25 x 20 mm) for fixing of Tk. 646.00
aluminium curtain rails as per design and drawing fitted and fixed in pos.ition .
including supply of screws, nails, drilling etc. and two coats of French polishing over
a coat of priming etc. all complete and accepted by the Engineer. (Rate is excluding
_._.,-- ,- ----- the cost ofpolishing and painting etc.)
22.6 Supplying, fitting and fixing vertical Venetian blinds made with glass fiber fabrics Tk. 1,655.00
(foreign made) with supply of all materials (foreign made) such as Head rail
(Aluminium), end cap-set, rod till, sigger (stopper) runner, spacer (link), Handling
cord, ball chain, link chair, cord-weight weight-plate plastic washer, glass fiber
fabrics, and head cap-set etc. all complete and accepted by the Engineer.
22.7 Supplying, fitting and fixing horizontal Venetian blinds 1n width made with Tk. 1,270.00
aluminium foilsl strips (foreign made) with supply of all materials (foreign made) such •
as head rail, bottom rail, rod till, head cap, bottom cap, gear box, stick, support and
cap, cord drum and support, bracket, cord lock, cord equalizer, top holder, ladder,
cord, handling cord and aluminium foils etc. all complete and accepted by the
Engineer.
22.8 Supplying, fitting, fixing of steel iron rack made of 50 x 50 x 6.35 mm vertical and Tk. 9,334.00
horizontal angle post, welding 63.5 mm x 6.35 mm F.I. bar placed horizontally as
braCing for the posts, 38 x 6.35 mm cross FJ. bars weld~d with vertical post, 12.7
mm thick M.S plate welded as cup shape at the bottom of post, supplying and fitting
rivets, charge for wielding, drilling, carrying, cutting, straightening, in required sizes
etc in all respect as per drawing, design and accepted by the Engineer.
PWD SoR 2014 for Civil Works 141
22.9 Supplying fitting, fixing of uPVC plastic door or window frame having specific Tk. 248.00 ' I
gravity 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BSIISO/IS. standards
fitted and fixed in brick wall! RC.C wall with 6 Nos. GI clamp, 4Nos inner jOint GI
clamp, 2 Nos. outer GI joint clamp, 16 Nos. rivet making necessary grooves and
mending good the damages, finishing, curing, carriage etc complete in all respect
accepted by the Engineer.
22.10 Supplying, fitting, fixing of uPVC hollow or solid plastic door shutter having
specific gravity 1.35 -1.45, thickness 1.7 mm-2.2.mm, and other physical, chemical,
thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards
or ASTM, BSII50115 standards of different sizes fitted fixed with uPVC plastic door
frame weighing 5.82 kg/m2 wnh at least 3 Nos. 55 hinges by min 64 Nos. 03.17 mm
and 3.97 mm 12.7 mm long rivets, 12 Nos. 25.4 mm 55 screws, (2) 9.38 mm, 150
mm long 55 tower bolts 2 Nos., 146 mm S5 handle by rivet 2 Nos., G.I inner jOint
234.95 mm x 127 mm clamp, 76.2 mm x 57.15 mm~ 25 mm dia 1 no S5 haspbolt,
special type round· lock, carrying the same to the site and local carriage etc.
complete in all. respect accepted by the Engineer
22.11 Supplying, fitting, fixing uPVC plastic or glass partition in plastiC frame fabricated
by 70 x 50 x 2 mm T and 50 x 40 x 2 mm I 50 x 30x 2 mm l-sections, providing
partition with 156 x 25 mm uPVC hollow section having wall thickness 2.5 mm 1
partition with 5 mm thick glass. Physical, chemical,· thermal, fire resistivity properties
r
etc of the materials ~s. per B5Tlapproved manufacturer standards or ASTM, .
8S/lSO/IS standards, fitted and fixed in brick wall or R.C.C wall with 6 Nos. GI
clamp, 4 Nos. inner joint GI'clamp, 2 Nos. outer GI joint clamp, 16 Nos. rivet making
necessary grooves and mending good the damages, finishing, curing, carriage etc
complete in all respect and accepted by the Engineer.
22.12 Supplying, fitting, fixing of uPVC Profile for door, window and fixed partition Tk. 439.00
frames applications having specific gravity 1.36·1.43, and other physical, chemical,
thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards
or ASTM, BS/l50115 standards including all accessories fittings with 6 Nos. steel
clamps complete in all respect as per drawing and accepted by the Engineer.
22.13 Supplying, fitting, fixing swing door shutter made of low density free foam (lDFF)
sheet having standard size 4' x 8'. Physical properties: density: 0.55-0.68 g/cm 3,
weighing 1.3 kg/sft, providing new sash (4"), sliding glass bead, rubber, screws, 3"
hinges 4 Nos., 4" tower bolt 2 Nos., 6" handle 2 Nos. etc. including all accessories
complete in all respect as per drawing and accepted by the Engineer.
22.13.1 6'-6 x 2'~ 6" size 8 mm thick uPVC swing door shutter
h
Tk. 8,762.00
22.13.2 7'-0" x 2'- 6" size 8 mm thick uPVC swing door shutter Tk. 9,027.00 (.,
@:
PWD SoR 2014 for Civil Works 142
22.13.3 7'-0" x 3-0 size 8 mm thick uPVC swing door shutter 9,293.00
22.14 Supplying fitting fixing of plastic wall paneling with 3 mm sheet, weighing 0.188 1,119.00
kg/sft fitted and mending good the damages, carriage to the site including glass
bead, partition frame, rubber, 5 mm clear glass fitted and fixed with screws, steel
clamp accepted by the Engineer.
22.15 Supplying, fitting, fixing of uPVC Profile fixed partition with 5 mm clear glass, 3,129.00
weighing 1.032 kg/sft fitted and mending good the damages, carriage etc. complete
in all respect accepted by the Engineer .
22.16 Supplying, fitting, fixing of uPVC profile sliding window having gross weighing 1.3
kg/sft (including glass) fitted and mending good the damages, carries etc complete in
all respect accepted by the Engineer.
22.17 Supplying, fitting, fixing of plastic wood paneling in false ceiling with 6 mm sheet, 1,147.00
weighing 0.358 'kg/sft fitt~ and mending good the damages, carries etc complete in
all respect acc~pted by the Engineer
22.18 Supplying, fitting and fixing approved quality.190 mm x 190 mm size glass bricks in 13,740.00
round stair wall complete in all respect and accepted by the Engineer.
22.19 Supplying, and fitting and fixing 50 mm thick rock or glass wool padding of 3,50~.OO
approved quality and accepted by the Engineer.
._-_._--....::-.:.---
I,
PWD SoR 2014 for Civil Works 143
23.1 Earthwork in excavation of tank of any dimension in all kinds of soil including
cutting up to required depth including bailing out water and throwing on the
embankment, breaking clods, ramming and leveling, dressing in 225 mm layer with
maintaining the side slopes and level of both tank and the embankment as per
design and accepted by the Engineer.
23.1.2 For each additionallitt of 0.3 mbeyond 1.5 mand up to 3 m Tk. 5.30
23.1.3 For each additionallitt of 0.3 mbeyond 3 m and up to 4.5 m Tk. 7.77
23.1.4 For each additionallitt of 0.3 mbeyond 4.5 mand up to 6 m Tk. '10.24
23.1.5 Extra each additional lead of 0.3 mor part there of beyond initial lead 30 meter Tk. 20.84
23.2,1 Bailing out water by 1 cusec diesel operated pump including hire charge of Tk. 458.00
pump, fuel, operator,~pares and maintenance etc. c~mplete.
23.2.2 Bailing out water by 1 cusec electricity operated pump including hire charge of Tk. 373.00
pump, fuel, operator, spares and maintenance etc. complete
24.1 Earth work in road embankment up to a lift of 1.5 m in all kinds of soil including
cutting and throwing earth in layers not exceeding 150 mm in thickness, breaking
clods up to 40 mm size in each layer, ramming, leveling and dressing as per required
side slope and alignment with earth borrowed from the road side Govt. acquired land
for any leads and maintaining the embankment true to level and side slopes as per,
profiles for one year from the date of completion including making dug, bailing,
profiling etc. complete and accepted by the EngineeL
24.1.2 For additional lift of 1 mbeyond 1.5 mup to 2.5 m Tk. 126.00
24.1.3 For additional lift of 1 mbeyond 2.5 mup to 3.5 m Tk. 142.00
24.1.4 For additional lift of 1 mbeyond 3.5 mup to 4.5 m Tk. 158.00
24.1.5 For additional lift of 1 mbeyond 4.5 mup to 5.5 m Tk. 173.00
24.1.6 For additional lift of 1 mbeyond 5.5 mup to 6.5 m Tk. 189.00
24.2 Earthwork in box cutting in all types of soil. Removing soil to a safe distance,
maintaining proper alignment, camber .and grade including leveling, dressing and
compacting the sub grade as per drawing and accepted by the Engineer
24.3 Creating turf on the side slopes and top of embankment with good quality turf not Tk. 13.00
less than 225 mm square chunk, watering till the Qrass grown including all leads and
lifts etc. complete and accepted by the Engineer.
24.4 Single layer brick flat soling in road work with first class or picked jhama bricks as Tk. 368.00
per alignment, camber and grade including filling joints with sand (F.M. 0.50) etc.
complete including cost of all materials and accepted by the Engineer.
24.5 Brick on edges pavement in herring bone bond (HBB) with first class or picked Tk. 601.00
jhama bricks as per alignment, camber and grade over 12 mm thick sand cushion
(F.M. 0.50) including filling the joints with the same sand including cost of all
materials and accepted by the Engineer.
24.6 Double brick flat soling in roadwork with first class or picked jhama bricks as per Tk. 744.00
camber and grade and filling the joints with fine sand (f.M. 0.50) and also providing
12 mm thick sand cushion in between the two layers of brick flat soling with the same .
quality of sand including cost of all materials and accepted by the Engineer.
24.7 Brick on end edging (75 mm across the road) with first class or picked jhama bricks Tk. 93.00
and filling the gaps with fine sand (F.M. 0.50) including cutting trenches, true to level
and grade, removing earth, refilling and ramming the sides proper!y including cost of
all. materials and accepted by the Eng!neer.
, l
)fMu/
PWD SoR 2014 for Civil Works 145
24.8 Breaking picked jhama, first class bricks or bats including cost of bricks and bats
, j
and stacking in measurable sizes at site accepted by the Engineer
24.9 Labour for compacted water bound Macadam base course with graded metal of Tk. 613.00
crushed well btmt, picked jhama or first class bricks and bats having compacted
thickness made as per specifications including local handling and spreading
. uniformly to· proper grade, camber and super elevation, hand packing, rOiling
properly with 8 .to 10 ton capacity power driven Road Roller and watering profusely
'. for compaction of 100% MOD (standard) blinding with sand (F.M. 0.80) @ 12 m3 per
m2 including fuel, lubricants, spares, maintenance, driver etc. all complete and
accepted by the Engineer.
24.10 Providing compacted sub-base base course with well graded metal of crushed well Tk. 3,379.00
burnt p.j. 11st class brick bats and sand (FM 0.8) with mixing proportion 2 : 1 having
compacted thickness made as per specification induding local handling, spreading
uniformly to proper grade camber and super elevation, packing rolling properly with 8
to 10 ton capacity power driven road roller and watering properly for compaction of
100% MOD· (standard) blinding with sand includiDg cost of fuel, lubricants, spares,
maintenance, driver etc. al! complete and accept~ by the Engineer in charge.
24.11 50 mm thick compacted premixed bituminous carpeling with 12 mm down well Tk. 1,046.00
graded stone chips having water absorption not greater than 2% flakiness index not
greater than 35 @0.64 cum of stone chips mixed with 42 kg of heated bitumen
(bitumen content % by wt. of total is 5.2% to 5.80%) heating at 1350C to 1550C and
spread uniformly over 10 sqm of surface, rolled with 8 to 10 ton Roller compacted
fully inpropergrade.andcamber spreading 0.12 cum sand (F.M.1.50) on 10 sqm
including tools and equipment etc. all complete and accepted by the Engineer.
NB: If Asphalt Plant is used rates will be increased by 25%.
24.12 38 mm thick compacted premixed bituminous carpeting with .10 mm down well Tk. 858.00
graded stone chips having water absorption not greater than 2%, flakiness index
not greater than 35 @ 0.32 cum of stone chips mixed with 22.00 kg of heated
bitumen (bitumen content % by wt. of total is 5.2% to 5.80%), heating at 1350C to
1550C and spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller
compacted fully in proper grade and camber and spreading 0.12 cum sand (F.M.
1.50) on 10 sqm surface etc. all complete and accepted by the Engineer.
NB: If Asphalt Plant is used rates will be increased by 25%.
24.13 25 mm thick compacted premixed bituminouS carpeting with 10 mm down well Tk. 626.00
graded stone chips having water absorption not greater than 2% flakiness index not
greater than 35 @ 0.32 cum of stone chips mixed with 22.00 kg of heated bitumen
(bitumen content % wt. of total is 5.2% to 5.80%), heating at 1350c to 1550c and
spread uniformly over 10 sqm of surface· rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber and spreading 0.12 cum sand (F.M. 1.50) on 10
sqm surface etc. all complete and accepted" by the Engineer.
NB:lf Asphalt PJant is used rates will be increased by 25%.
PWD SoR 2014 for Civil Works 146
24.14 50 mm thick co'mpacted premixed bituminous carpeting with 12 mm down well Tk. 885.00
\"
graded shingles @ 0.64 cum of shingles mixed with 42 kg of heated bitumen
(bitumen content %by wt. of total is 5.2% to 5.80%) heating at 1350c to 1550c and
spread uniformly over 10 sqm of surface. Rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber spreading 0.12 cum sand (F.M. 1.50) on 10 sqm
etc. all complete and accepted by the Engineer. NB: If Asphalt Plant is used rates will
be increased by 25%.
24.15 38 mm thick compacted premixed bituminous carpeting with 12 mm down well Tk. 737.00
graded shingles @ 0.48 cum of shingles mixed with 30.25 kg of heated bitumen
(bitumen content % by wt. of total is 5.2% to 5.80%), heating at 1350c to 155°c
spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller compacted
fully in proper grade and camber and spreading 0:12 cum sand (F .M.-1.50) on 10
sqm surface including necessary tools and equipment etc. all complete and accepted
by the Engineer. NB: If Asphalt Plant is used rates will be increased by 25%.
24.16 25 mm thick compacted premixed bituminous carpeting with 10 mm down Tk. 495.00
graded and wen grades shingles @0.32 cum of shingles mixed with 20.50 kg of
heated bitumen (bitumen content % by wt. of total is 5.2% to 5.80%), heating at
1350c to 155°c spread uniformly over 10 sqm of surface rolled with 8 to 10 ton Roller
compacted fully in proper grade and camber and spreading 0.12 cum sand
(F.M.1.50) on 10 sqm surface including necessary tools and equipment etc. all
complete and accepted by the Engineer. NB: If Asphalt Plant is used rates will be
increased by 25%.
24.17 Providing tack coat @ 7.32 kg of bitumen per 10 sqm including heating bitumen up Tk. '87.00
to 176°C to 188°C and spreading etc. all complete (cost of bitumen included)
accepted by the Engineer.
i
-------,;- --.- . 24.18 Providing ,seal coat with 4 eft of'Sylhet sand (FM 2.2) mixed with @ 7.32 kg of TK~ 186.00 '.
bitumen per 10 sqm of road surface including supplying and spreading of 0.09 cum
of sand (F.M. 0.80) including heating bitumen up to 176 degree to 190 degree
Celsius and spreading etc. all complete (cost of bitumen included) accepted by the
Engineer.
24.19 Premixed bituminous seal coat with 0.12 cum of pea gravels mixed with 80 kg of Tk.. 235.00
bitumen per cu~ of pea gravels and laid over 10 sqm, road surface, spreading with
proper camber, grade, surface blinding with dry sand (F.M. 2.5) @ 0.09 cum per 10
sqm, rolling the suface with min 8 ton power driven roller etc. all complete and.
accepted by the Engineer.
24.20 Providing bitumenous painting with 4.54 kg of bitumin per 10 sqm. of road surface TIt. 104.00
including supplying and spreading of 0.09 cum of sand (FM 1.20) with heating
bitumen upto 176 degree to 196 degree celsius, surface rolling with min 8 ton power
driven roller etc. all complete and accepted by the Engineer.
24.21 Providing painting top of the road surface as road marking in two "",ats with Tk. 223.00
approved best quality and colour of synthetic approved quality of paint from
authorized local agent of the manufacturer in a sealed container having highly water
resistant, high bondability, flexible, using specific brand thinner applied by brass/
roller or others over a coat of priming elapsing lime for drying including surface
cleaning from dust, oil or dirt, smoothening, finishing necessary tools etc. all
complete in approved and accepted by the Engineer.
PWD SoR 2014 for Civil Works 147
24.22 Providing expansion joints across the R.C.C. road pavement with 20 mm gap Tk. 317.00
between the adjacent panels. Supplying dowel bars of size 12 mm dia 600 mm long
M.S rod placed at 750 mm c/c. 300 mm of the bar fixed within one slab keeping
remaining portion the bar free within the adjacent slab being inserted in 20 mm dia
300 mm long P.V.C. pipe embedded in the slab, inside of pipe fully greased, filling
. the gap betWeen the slabs (with admixture) of hot bitumen and coarse sand (F.M.
2.5) in proportion (2: 1) finishing the top with bitumen, spreading coarse sand over the
joint, all complete as per plan, drawing and accepted by the Engineer.
25.1 Labour charge for scraping lawn surface up to 38 mm thick by spade, picking up all Tk. 7.10
sorts of bricks bats, rubbish by suitable tools, removing the sallie by head load or by
any other means and stacking the same,to a safe distance beyond 300 m including
supply of tools and plants etc. all complete and accepted by the Engineer.
25.2 Preparation 'of ground to make ready for plantation by spading the ground in to a Tk. 15.00
depth of 150 mm to 230 mm beyond 38 mm thick scrapped ground by, spade,
breaking earth clods to powder by hammers, picking up all sorts of rubbish,
unwanted grasses by suitable tools, carrying and spreading the surplus earth into
low lying area including supply of tools and plants etc. all complete and accepted by
the Engineer.
25.3 Leveling and dressing' of lawn area to proper slope and grade by spading the Tk. 4.70
same up to 150 mm including supplying tools and plants etc. all complete and
accepted by the Engineer.
25.4 Supplying of best and approved quality alluvial loamy siHy soil including loading, Tk. 567.00
unloading at both ends, properly stacking at site including supply of tools 'and plants
etc. all complete and accepted by the Engineer.
25.5 Supplying well decomposed cow dung carried by ,trucks or any other means Tk. 1,183.00
including loading, unloading at both ends, stacking the same at site including supply
of tools and plants etc. all complete and accepted by the Engineer.
'-"- .. '-/- ---- 25.6 Labour charge for spreading the alluvial loamy silty soil from the stacks at site on Tk. 115.00
the lawn surface, leveling, dressing the same including supply all necessary tools
and plants etc. all complete and accepted by the Engineer.
25.7 Supplying lawn grass of approved quality by truck or any other means, sorting the Tk. 41.00
grass to proper size, washing the grass,. dibbling the grass 6 mm to 50 mm apart,
irrigation of lawn area till the grass grown at least for two months after plantation,
weeding the undesirable grass, mowing the lawn grass by lawn mower up to two
months after plantation, appl~ng urea fertilizer on the lawn surface @ 1 kg per 9.29
sqm including supply of tools and plants etc. all complete and accepted by the
Engineer.
25.8 Labour charge for mixing well decomposed cow dung with alluvial loamy silty Tk. 107.00
soil and excavated earth, removing the excess earth to safe distance including
supply of tools and plants etc. all comple~ 'lnd accepted by the Engineer.
25.9 Supplying and providing, fitting, fixing bamboo jafry fencing by best quality muli Tk. 364.00
bamboo split 20~m in width, having 75 mm x 75 mm mesh placed horizontally and
diagonally doing 25 mm framing a square shape. in both ways and both sides
tightened with G.I wire fitted with Borrak bamboo post of 100 mm dia and placed
firmly in position at 1800 mm apart including supply oftoe:-. ~nd plants, digging hole
,and filling back etc. all complete and accepted by the Engineer.
, \
~
PWD SoR 2014 for Civil Works 149
25.10 Supplying and providing, fitting, fixing muli bamboo tree guard 1200 mm long and Tk. 481.00
500 mm dia fixing with best quality muli bamboo split 20 mm in size having 75 mm x
75 mm a square holes with 20 mm wide bamboo splits strengthen with 4 Nos. 20 mm
wide bamboo spl~ in both sides tightened with G.I wire fitted with 3 Nos. 63 mm dia
borrak bamboo post of 1800 mm long of which 600 mm will be driven into earth by
digging hole followed by fill back including supply of tools and plants all complete as
per direction of engineer-in-charge.
25.11 Earth work in excavation to make a pit of 600 x 600 x 450 mm (depth) for Tk. 110.00
plantation, applying cow dung mixing with loamy silty soil and excavated earth,
planting the plants, tightened with 1800 mm long borrak bamboo post with jute rope
including supply of tools and plants all complete and accepted by the Engineer.
25.12 Spading for preparation of flower beds in pits up to 600 mm depth, re-molding, Tk. 364.00
picking up and placing an(l removing the spaded earth to a safe distance, mixing @
1 cft well decomposed cow dung with 20% loamy silty soil and 6 cft excavated soil
ahd flll back the pit including supply of tools and plants all complete and accepted by
the Engineer.
25.13 Preparation of hedge beds by excavation of earth up to 300 mm depth filling up the Tk. 183.00
bed by a mixture of cow dung, loamy silty soil, cutted earth @ 1 cft cow dung manure
per 6 eft of cutted earth and 20% loamy silty soil including supply of tools and plant
etc. all complet~ and accepted by the Engineer.
25.14 Carrying of rubbish, taking up all sorts of bricks, brick-bats and rubbish gravel . Tk. 111.00
chips, loading and unloading at both ends including supply of tools and plants etc. all
complete and accepted by the Engineer.
25.15 Supply and carrying of 12.20. m long 100 mm dia borrak bamboo at site, loading Tk. 378.00
and unloading at both end stacking the same at site including supply of tools and '(
plants etc. all complete and accepted by the Engineer.
25.16 Supply and carrying of 7.62 mlong 50 mm to· 62.5 mm dia muli bamboo at site, Tk. 17f.OO
-loading and unloading at both end stacking the same at site including supply of tools
and plants etc. all complete and accepted by the Engineer.
26.1 Supplying, fitting and fixing European type glazed porcelain commode "S" type
465 x 340 x 415 mm in size, approximately 14 kg by weight, plastic seat cover and
preparing the base with cement concrete and with wire mesh or rods, if necessary, in
all floors including making holes wherever required and mending good the damages
and fitting, fixing finishing etc. complete with all necessary fittings and connection
approved and accepted by the Engineer.
26.1.1 Standa'rd
26.2 Supplying, fitting and fixing European type glazed porcelain low-down, capacity 10
liter, 490 x 190 x 350 mm in size, approximately 14 kg by weight, on walls by screws
, and F.1. bar clamps, rowel plugs, making holes wherever required and mending good
the damages and fitting, fixing finishing etc. complete with all necessary fittings and
connection approved and· accepted by the Engineer..
26.2.1 Standard
26.3 Supplying, fitting and fixing European type glazed porcelain Combi closet, in/c
plastic seat cover, cystem system, preparing the base with cement concrete and with
wire mesh or rods if necessary, in all floors including making holes wherever required
and mending good the damages and fitting, fixing, finishing etc. complete, with all ,
necessary fittings and connection approved and accepted by the Engineer.
26.3.1 Standard
26.3.1.1 BISF White, Item No. 115A1415A, 700 x 410 x 795 mm,31.5 kg Tko 7,242.00
26.3.1.2 BISF Coloured :·em No. 115AJ415A, 700 x 410 x795 mm,31.5kg Tk. 7,242.00
26.3.1.3 BISF ..,pecial coloured Item No. 115A1415A, 700x410x795 mm,31.5kg Tk. 8,679.00
26.3.2 Super
.~
PWD SoR 2014 for Civil Works 151
26.3.3 Superior
26.4 Supplying, fitting and fixing· European type glazed combi closet,
approx.725x360x840 min size, approx. 42.7 kg by weight,in/c plastic seat cover,
cystem system, preparing the base with cement concrete and with wire mesh or rods
if necessary, ·in all floors including making holes wherever required and mending
good the damages and fitting, fixing, finishing complete with all necessary fittings and
connection approved and accepted by the Engineer.( an exclusive item, subject to
approval by not less than SE)
26.5 Supplying, fitting and fixing Bangladesh pattern, long pan with foot-rest, made of
Vitreous China and preparing the base of pan with cement mortar (1 :4) and with wire
mesh or rods, if necessary in all floors including making holes wherever required and
mending good the damages and fitting, fixing, finishing etc. complete with all
necessary fittings and connection approved and accepted by the Engineer.
26.5.1 Standard
26.5.2 Super
26.6 Supplying, fitting and. :ng Bangladesh pattern lo.ng pan, made of Vitreous China
and preparing the base of pan with cement concrete and with wire mesh or rods if
necessary in all floors including making holes wherever required and mending good
the damages and fitting, fixing, finishing etc. complete with all necessary fittings and
. connection approved and accepted by the Engineer.
26.6.1 Standard
26.7 Supplying, fitting and fixing plastic low-down including all fittings and accessories Tk. 2,017.00
26.8 Supplying 280x140x30mm. size glazed porcelain foot rest, 1.5 kg by weight Tk .. 174.00
including fitting, fixing in position with cement mortar (1:4) if necessary in all floors
including making' holes wherever required and mending good the damages· and
fitting, fixing, finishing etc. complete with all necessary fittings and connection
approved and accepted by the Engineer.
26.9 Supplying, fitting and fixing white glazed vitreous W/H Wash Basin including
excluding pedastal, fitting, fixing the same in position with heavy type C.I. Brackets.
30 mm dia PVC waste water pipe with brass coupling (not exceeding 750 mm in
length), basin waste with chain plug including making holes in walls and floors and
fitting with wooden blocks, screws and mending good the damages, finishing etc. all
complete approved and accepted by the Engineer.
26.9.1 Standard
~
PWO SoR 2014 for Civil Works 153
Cabiet Basin
Corner. Basin
26.10
Supplying, glazed .vitreous W/H Wash Basin in/c pedastal approx. size
.656x510x845,26kg by weight including fitting, fixing the same in position with heavy
type C.1. Brackets. 30 mm dia PVC waste water pipe with brass coupling (not
exceeding 750 mm in length). 12mm plastic lead (connectiqn) pipe with brass
coupling, basin waste with chain piug including making holes in walls and floors and
fitting with wooden blocks, screws and mending good the damages, finishing etc. all
complete approved and accepted by the Engineer.
26.10.1 Superior
26.11 Supplying, white glazed vitreous W/H Wash Basin in/c pedastal and fitting, fixing
the same in position with heavy type C.I. brackets, 32 mm dia PVC waste water pipe
with brass coupling (not exceeding 7S0 mm in length), 32 mm dia C.P. basin waste
with chain plug, bracket including making holes in walls and floors and fitting with
wooden blocks, screws and mending good the damages with cement mortar (1:4),
etc. all complete approved and accepted by the Engineer.
26.11.1 Super
26.12 Supplying, fitting and fixing basin pedestal, with rowel plug and screws etc. all
complete approved and accepted by the Engineer.
'\
~ ~
PWD SoR 2014 for Civil Works 154
26.12.1 Standard
26.12.2 Super
26.12.3 Superior
26.13 Supplying, fitting and fixing glazed vitreous standing bowl urinal, fitting, fixing the
same in position after making holes in walls and floors, providing 32 mm dia plastic
waste pipe with brass coupling up to grading below, 12 mm dia plastic connection
pipe With brass coupling, 12 mm dia brass stop cock including mending good the
damages w~h cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
26.13.1 Standard
26.13.2 Super
26.14 Supplying, fitting and fixing glazed vitreous china flat or squatting urinal
510x380x85mm in size, approx. 9.5 kg by weight with flushing inlet fitted in cement
mortar (1 :4) with painted cast iron body: one gallon capacity, automatic flushing
cistern in each group etc. including 12 mm brass controning valve, 32 mm dia PVC
flush pipe with brass coupling, 12 mm dia plastic lead (connection) pipe including
mending good the d~mages with 1:4 cement mortar etc. all complete approved and
accepted. by the Engineer.
~
PWD SoR 2014 for Civil Works 155
26.15 Supplying, fitting and fixing ,porcelain sink fitted and fixed with heavy type C.I.
brackets, 12 mm dia C.P. bib cock, 40 mm dia C.P. chain plug. 40 mm dia. C.P.
waste,4O mm dia PVC waste pipe with brass coupling (750 mm length) including
making holes in walls and floors and mending good the damages with cement mortar
(1:4) etc. all complete approved and accepted by the Engineer. '
26.16 Supplying, fitting and fixing single bowl stainless steel sink with sink tray size Tk. 4,090.00
(450 x 1050 mm.) with heavy type CI steel brackets 12mm dia C.P. bib-cock 40 mm
dia C.P. chain plug. 40 mm dia C.P. waste. 40 mm dia PVC waste pipe with brass
coupling (750 mm length) including making hole in walls and floors and mending
good the damages, finishing with 1:4 cement mortar etc. all complete approved and
accepted by the Engineer. (Malaysia I Singapore I Thailand made or equivalent)
26.17 Supplying, fitting and fixing double bowl stainless steel sink with sink tray with Tk. 7,596.00
heavy type CI or steel brackets 12 mm dia C.P. chain plug. 40 mm dia C.P. waste,
40 mm dia PVC waste pipe with brass coupling (750 mm length) including making
hole in walls and floors and mending good the damages, finishing etc. all complete
approved and accepted by ,the Engineer. (Malaysia I Singapore / Thailand made or
equivalent) .
26.18 Supplying, fitting and fIXing of 450 x 600 mm size and 5 mm thick unframed super Tk. 786.00
f
quality mirror with hard boards at the back with all necessary fitting including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the· Engineer. (Made in Japan or equivalent)
26.19 Supplying, fitting and fixing of 450 x 350 mm size and 5 mm thick unframed super Tk. 621.00
quality mirror with hard boards at the back with all necessary fitting including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer. (Made in Japan or equivalent)
26.20 Supplying, fitting and fixing super quality 600 x 125 mm coloured glass (plate) Tk. 1,258.00
shelf having 5 mm thickness with fancy C.P. brackets, screws and frames including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer.
26.21 Supplying, fitting and fixing super qualny ,600 x 125 mm white glass (plate) shelf Tt" 689.00
having 5 mm thickness with fancy C.P. brackets, screws and frames including
making holes in walls and mending good the damages with cement mortar (1:4) etc.
all complete approved and accepted by the Engineer.
26.22 Supplying, fitting and fixing super quality C.P. Towel rail of 600 mm long and 20 Tk. 637.00
mm in dia with C.P. holder including making holes in walls and mending good the
damages with cement mortar (1 :4) etc. all complete approved and accepted by the
Engineer.
J
'\
(!{ ~
PWO SoR 2014 for Civil Works 156
26.23 Supplying; fitting and fixing medium quality C.P. Towel rail of 600 mm long and 20 Tk. 537.00
mm In dia withe.p. holder including making holes in walls and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
Engineer.
26.24 Supplying, fitting and fixing standard toilet paper holder of 150 x 150 x 126 mm size'
including making holes in walls and mending good the damages with cement mortar
(1 :4) etc. all complete approved and accepted by the Engineer.
26.25 Supplying, fitting and fixing of special coloured toilet paper holder Size (150 mm x
150 mm x 126 mm) including making holes in walls and mending good the damages
with cement mortar (1 :4) etc. all complete approved and accepted by the Engineer.
26.25.2 • do • Standard size stainless steel bracket and holder rod with cover. Tk. '406.00
26.25.3 • do - Standard size, C.P iron bracket with plastic holder rod. Tk. '340.00
Supplying, fitting and fixing standard size soap tray including making holes in walls
and mending good,the damages with cement mortar (1:4) etc. all complete approved
and accepted by the Engineer.
26.27 Supplying, fitting and fixing 125 mm dia stainless steel floor grating in traps or in Tk. 198.00
drains inciuJing making holes in wallslfloors and mending good the damages with
~"rnent mortar (1 :4) etc. all complete approved and accepted by the Engineer.
26.28 Supplying, fitting and fixing 62 mm dia stainless steel floor grating in traps or in Tk. 145.00
drains including making holes in, wails/floors and mending good the damages with
cement mortar (1 :4) etc. all complete approved and accepted by the Engineer.
26.29 Supplying, fitti% ~'ld fixing plastic grating with hinged cover size 150 x 150 mm in Tk. 345.00
traps or in drains including making h~les in walls/floors and mending good the
damages with cement mortar (1:4) etc. all complete approved and accepted by the
I,
Engineer.
~ ~
PWD SoR 2014 for Civil Works 157
26.30 Supplying 100· mm inside diameter HCI rainwater down pipe, fitting and fixing in Tk. 1,864.00
position with head and shoes, bends, trap, tee, offset, clamps and nails etc. complete
in aU floors approved and accepted by the Engineer.
26.31 Supplying 100 mm inside diameter best quality uPVC rain water down pipe fitting, Tk. 642.00
fixed in position with head and shoes, bends, min.20 mm width F.I. Bar clamp and
nails, and including all accessories such as round grating/domed roof grating bands,
sockets approved and accepted by the Engineer.
26.32 Supplying 50 mm insidedia HCI soil, waste and ventilation pipe each piece Tk. 962.00
having over length 1800 mm, thickness 6.5mm, spigot diameter 80 mm, weight min
12 kg fitted and fixed in position with sockets thickness min 8.5 mm, internal depth
min 68 mm, bead's outside diameter min 90 mm, ears flange length min 150 mm,
caulking clearance min 10 mm produced in foundry grade pig iron as per BSTI
approved manufacturer standard .fitting and fixing in. position including head and
shoes bends made of minimum 20 mm x 3 mm F.I. bar or equivalent, trap, tee,
offset clamps and nails etc. complete in all floors approved and accepted by the
Engineer.
26.33 Supplying 100 mm inside dia HCI soil, waste and ventilation pipe each piece· Tk. 1,813.00
having over length 1800 mm, thickness 6.5 mm, spigot diameter 117 mm, weight niin
24.85 kg fitted and fixed in position with sockets thickness min 6.5 mm, internal
depth min 75 mm, bead's outside diameter min155 mm, ears flange length min 208 .
mm, caulking clearance niin 8 mm produced in foundry grade pig iron as per BSTI.
approved manufacturer standard fitting and fixing in position including head and
shoes bends made of minimum 20 mm x 3 mm F.1. bar or equivalent, trap,' tee,
offset, clamps and nails etc. complete in all floors accepted by the Engineer.
26.34 Supplying 150 mm inside dia HCI soil, waste and ventilation pipe each piece Tk. 2,640.00
r
having over length 1800 mm, thickness 6.5mm, spigot diameter 117mm, weight min.
41 kg fitted and fixed in position with sockets thickness min 7mm, internal depth min
100 rnm bead's outside diameter min 200mm, ears flange length min 258.mm,
caulking clearance min 9 mm produced in foundry grade pig iron fitting and fixing in
position including head and shoes, bends, trap, tee, off-set, clamps and nails etc.
complete in all floors approved and accepted by the Engineer.
26.35 Supplying 50 mm inside dia best quality uPVC soil, waste and ventilation pipe Tk. 446.00
having specific gravity 1.35 - 1.45, wall thickness 2.5 - 3.0 mm, and other physical,
. chemical, thermal, fire resistivity properties etc. as per BSTr approved manufacturer
standards or ASTM, BSIISOIIS standards fitted and fixed in position with sockets,
bends, of uPVC Pipe with all accessories such as Round grating /domed roof grating
bands, sockets etc. approved and accepted by the Engineer (length: 6000 mm
each).
26.36 Supplying 100 mm inside dia best quality uPVC soil, waste and ventilation pipe Tk. 739.QO
having specific gravity 1.35-1.45, wall thickness 3.4- 4.0 mm, and other physical,
chemical, thermal, fire resistivity properties etc ..as per BSTI approved manufacturer
standards or ASTM, 8S/ISOIIS standards fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating bands,
sockets etc. approved and accepted by the Engineer (length: 6000 mm each).
/\
PWD SoR 2014 for Civil Works 158
26.37 Supplying 150 mm inside dia best quality uPVC soil, waste and ventilation pipe :}~;}~;"iii1,:;'!)ii$j 1,073.00
having specific gravity 1.35 - 1.45, wall thickness 4.5 mm - 5.2 mm, and other
physical, chemical, thennal, fire resistivity properties etc. as per 8STI approved
manufacturer standards or ASTM, 8S/ISOIIS standards fitted and fixed in position
with sockets, bends, with all accessories such as Round grating/domed roof grating
bands, sockets etc. approved and accepted by the Engineer (length: 6000 mm
each).' .
26.38 Supplying, fitting and fixing G.1. pipe conforming to the standard 8S-1387 &BOS-
1031, having chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20,
Sulphur 0.060 max, Phosphorous 0.060 max, Tensile properties: miminum Yield
Strength 188 MPa, minimum Tensile Strength 313 MPa and marking for a)
Manufacturer b) Material c) Wall thickness d) Nominal· outside dia e) Intended
use etc. on the body of the pipe with all special fittings, such as bends, elbows,
sockets, reducing· sockets, tee, unions, jam-nuts etc. including cutting trenches
where 'necessary and fitting the same with earth duly rammed and fixing in walls with
holder bats and making hole in floors, walls and consequent mending good the
damages etc. all complete in all respects approved and accepted by the Engineer.
(Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation,
Ministry of Industries, Government of Bangladesh shall be given priority)
26.38.1 15 mm dia G.I. pipe with wall thickness 2.65 mm, outside diameter min 21 mm, ' 301.00
weight 1.31 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.2 20 mm dia G.I. Pipe with wall thickness 2.65 mm, outside diameter min 26.5 mm, 390.00
weight 1.70 kg/m, can Withstand min 50 kg/cm2 hydraulic pressure.
26.38.3 25 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 33.3 mm, 508,,00
weight 2.59 kglm, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.4· 32· mm dia G.I. Pipe· with wall thickness 3.25 mm, outside diameter min 42 mm, 644.00
weight 3.33 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.5 40 mm dia G.I. Pipe with wall thickness 3.25 mm, outside diameter min 47.9 mm, 869.00
weight 3.83 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.6 50 mm dia G.I. Pipe with wall thickness 3.65 mm, outside diameter min 59.7 mm, 1,083.00
weight 5.38 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.7 62-65 mm dia G.!. Pipe with wall thickness 3.25 mm, outside diameter min 75.2 mm, 1,541.00
weight 6.15 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.8 75-80 mm dia G.!. Pipe with wall thickness 3.25 rpm, outside diameter min 87.9 mm, 1,899.0q
weight 7.22 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
26.38.9 100 mm dia G.I. Pipe with wall thickness 3.65 mm, outside diameter min 113 mm, 2,520.00
weight 10.42 kg/m, can withstand min 50 kg/cm2 hydraulic pressure.
Supplying diffe~nt inside dia uPVC pressure pipe C-Grade I Having density 1350
26.39
kg/m3. opacity 0.2% of visible light as per ISO 7686, minimum required strength 25
MPa conforming to BOS-1 :2013, 4.4.1, 4.4.2 for water supply having specific
gravity 1.35 - 1.45, and other physical, chemical, thermc" 1re resistivity properties
etc. as per 8STI approved manufacturer standards or ASTM, BS/lSOIlS standards
fitted and fixed in position with sockets, bends, with all accessories such as Round
grating/domed roof grating , bends, sockets etc. approved and accepted by the
Engineer. (length: 6000 mm each)
PWD SoR 2014 for Civil Works 159
26.40 Supplying different inside dia best quality CPVC pressure pipe Having density 1350
kg/m3, opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 .
MPa conforming to BOS-1:2013, 4.4.1, 4.4.2 for water supply having specific
gravHy 1.35 - 1.45, and other physical, chemical, thermal, fire resistivity properties
etc. as per BSTI approved manufacturer standards or ASTM, BS/lSO/lS standards
fitted and fixed in positiqn with sockets, bends, with all accessories such as Round
grating/domed roof grating, bends, sockets etc. approved and accepted by the
Engineer. (length: 6000 mm each)
26.41 Supplying different inside dia best quality ABS pressure pipe for water supply
having specific gravity 1.35 - 1.45, and other physical, chemical, thermal, fire
resistivity properties etc. as per BSTI approved manufacturer standards or ASTM,
BS/lSO/lS standards fitted and fixed in position with sockets, bends, with all
accessories such as Round grating/domed root grating, bends, sockets etc.
approved and accepted by the Engineer lI~ngth: 6000 mm each)
'\
~
PWD SoR 2014 for Civil Works 160
26.42 Supplying, fitting and laying HCI soil pipe each piece having over length 1800 mm,
thickness 5.5 mm, spigot diameter ·116 mm, weight min 24.85 kg fitted and fixed in
position with sockets thickness min 6.5 mm, internal depth min 75 mm, bead's
outside diameter min 155 mm, ears flange length min 208 mm, caulking clearance
min 7.5 mm produced in foundry by grade pig iron as per 6STI approved
manufacturer standard fitting and fixing in position including head, shoes, bends,
trap, tee, offset, clamps and nails etc. complete in all floors approved and accepted
by the Engineer.
26.43 Supplying, fitting and laying up to depth of invert 100 mm inside dia best quality
uPVC pressure soil pipe having specific gravity 1.3 -1.45, and other physical,
chemical, thermal, fire reSistivity properties etc. as per 6STI approved manufacturer
. standards or ASTM, 6S/ISOIIS standards fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating etc. complete
approved and accepted by the Engineer (length: 6000 mm each). .
26.43.1 uPVC soil pipe 100 mm dia wall thickness 2.7 mm - 3.4 mm, 553.00
26.43.2 uPVC soil pipe 150 mm dia wall thickness 4.0 mm - 4.5 mm, 724.00
26.44 Supplying, fitting and fixing laying Pipes up to depth of invert dia .R.C.C pipe having
1.83 meter in length made of stone chips with 40 mm cement joint including all
fittings and specials like. plain bend, Tees, reducing sockets, junctions, door bends
cowls, anti-siphon. gasket and cement joints, making holes in walls and mending
good the damages etc·. all complet~ approved and accepted by the Engineer.
26.45 Supplying 100 mm dia uPVC pipe for waste including fitting, fixing etc. all complete . Tk. 575.00
approved and accepted by the Engineer.
26.46.1 Supplying 150 mm dia uPVC pipe for underground laying including fitting, fixing etc. 764.00
all complete approved and accepted by the Engineer.
26.46.2 Supplying 200 mm dia uPVC for. underground laying including fitting, fixing etc. all Tk. 1,459.00
complete approved and accepted by the Engineer.
·26.46.3 Supplying 250 mm dia uPVC for underground 'Iaying including fitting, fixing etc. all 2,019.00
complete approved and accepted by the Engineer.
26.46.4 Supplying uPVC waste pipe 280 mm dia with wall thickness 6.9 mm - 8.6 mm for 2,463.00
underground laying including fitting, fixing etc. all complete approved and accepted
.by the Engineer. .
PWD SoR 2014 for Civil Works 161
26.46.5 Supplying uPVC waste pipe 315 mm dia with wall thickness 7.7 mm - 9.7 mm for Tk. 3,368.00
underground laying including fitting, fixing etc. all complete approved and accepted
by the Engineer.
26.47 Supplying, fitting and fixing G,I. Union with sealant etc. complete in all respects
approved and accepted by the Engineer.
26.48 Supplying, fitting and fixing best quality GJ. gate valve with sealant etc. complete
approved and accepted by the Engineer.
26.49 Supplying, fitting and fixing best quality G.I. Globe valve, threaded joint with sealant
etc. complete approved and accepted by the Engineer.
26.50 Supplying, fitting and fixing best quality G.I. Check valve, threaded joint with sealant .
etc. complete approved and accepted by the Engineer.
26.51 Suppl~ng, fitting and fixing best quality G.I. Float valve, threaded jOint Pit valve etc.
complete approved and accepted by the Engineer.
26.52 Supplying, fitting and fixing European type HCI P·Trap drainage pipe preparing the
base with cement concrete in 1:2:4 and with wire mesh or rods if necessary, in all
floors including making holes wherever'required and mending good the damages
and fitting, fixing complete with aI/ necessary fittings and connection approved and
accepted by the Engineer.
26.52.2 100 x 100 mm or 100 x 50 mm size Hel Yor T-Y Cleanout Tk. 1,249.00
~ ~
PWD SoR 2014 for Civil Works 163
26.52.3 150 x 150 mm or 150 x 100 mm size Hel T-Y or Y Cleanout Tk. 1,572.00
26.53 Supplying different inside dia best quality uPVC pressure waste pipe having
specific gravity 1.35 -1.45, wall thickness 2.7 mm - 3.4 mm, and other physical,
chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer
standards or.ASTM, BS/ISOIIS standards, fitted and fixed in position with sockets,
bends, with all accessories such as Round grating/domed roof grating bands,
sockets etc. complete approved and accepted by the Engineer.
26.54. Supplying, fitting and fixing best quality faucets etc. complete approved and
accepted by the Engineer
26.55 Supplying, fitting and fixing best quality CP pillar cock etc. complete approved and
accepted by the Engineer i
26.55.1 12 mm CP medium quality pillar cock Tk. 840.00
26.56 Supplying, fitting and fixing best quality concealed fixed sink cock etc. complete
approved and accepted by the Engineer
26.57.1 Supplying, fitting and fixing CP Basin Mixture with all necessary hardware and Tk. 2,338.00
. consumables approved and accepted by the Engineer.
26.57.2 Supplying, fitting and fixing CP Single Handle Basin Mixture with all necessary Tk. 1,~J4.00
hardware and consumables approved and accepted by the Engineer.
26.58 Supplying, fitting and fixing CP Shower Mixture including Shower Head only with Tk. 3,404.00
a/l necessary hardware and consumables approved and accepted by the Engineer.
26.59 Supplying, fitting and fixing CP Shower Mixture including Shower Head and Tk. 4,867.00
faucet with all necessary hardware and consumables approved and accepted by the
Engineer. .
I
"
~
PWD SoR 2014 for Civil Works 164
26.60 Supplying, fitting and fixing CP 8ath tub Mixture ~ith Shower Head only including Tk. 5,110.00
all necessary hardware and consumables approved and accepted by the Engineer.
26.61 Supplying, fitting and fixing CP Self closing pillar cock with all necessary hardware Tk. 971.00
and consumables approved and accepted by the Engineer
26.62 Supplying, fitting and fixing SpeciaVFancy quality C.P. concealedl surface stop
cock wfth all necessary hardware and consumables approved and accepted by the
Engineer.
26.62.1 12 mm brass Stop Cock for Surface Mount (general quality) Tk. 307.00
26.62.2 12 mm CP Stop Cock for Surface Mount (medium quality) Tk. 382.00
26.62.3 12 mm CP Stop Cock for Surface Mount (special type) Tk. 919.00
26.63 Supplying, fitlingand fixing Special/Fancy quality C.P. concealedl Surface Angle
stop cock etc. complete approved and accepted by the Engineer.
26.63.2 12 mm CP medium quality surface &heavy type fancy angle stopcock .. Tk. 827.00
-',~)~
.~----.--' -----
26.63.3 12 mm surface special heavy type angle stop cock Tk. 795.00
26.64 Groove cutting in brick work, R.C.C floor, including cost for concealing of G.I. pipe
work (12 mm and 20 mm dia) in brick wall by cutting groove in wall, lintel, beam etc.
by any means carefully without damaging the structure and filling the grooves with
C.C (4:2:1) after laying of pipe including cost of scaffolding, finishing, curing etc. all
complete approved and accepted by the Engineer.
26.64.1 Groove Size 40 x40 mm (For laying 12 mm to 20 mm dia pipes) Tk. ·49.00
26.65 Supply and fitting-fixing cleansing shower for ablution including holder of following
types:
~. )W~
PWD 50R 2014 fo/' Civil Works 165
26.67 Sl!Pplying, fitting fixing of food grade plastic overhead water reservoir tank
including all necessary fittings, hardware and consumables etc. all complete
approved and accepted by the Engineer.
26.68 Supply and installation of food-grade plastic internal mini water tank for the use in ".'. ;,',':;:'."".," . ',' ' ' ."' .
kitchen, bathroom and toilet for emergency storage and supply of water ,. . '.,.:. .".,.,...... " . . .,. ,.
manufactured from liner low density polyethylene (ILOPE) rota-grade (ultra violet)
stabilized which complies FDA (Federal Department of Agriculture, USA) r~gulations '.·•.··.'.<·';.'i).~i:,.'),}..>
21 CFR 1277. 152, having food grade quality where no recycled material is used +\c:;:·,;.:"\::A·\'.•.,· ·.:::·,·,
carrying. lifting, fitting, fixing in position including supply of necessary hardware,
consumables, fittings .etc. all complete approved and accepted by the Engineer.
26.69 Supply' and installation of foreign made food grade stainless steel water tank
including supply of hardware, consumables. fittings etc. all complete approved and
accepted by the Engineer.
26.70 Supply and installation of 400 gallon capacity Ferro-cement water tank including Tk. 7,886.00
necessary t"'Q,dware, fittings and consumables etc. all complete approved and
ac~epted by the Engineer.
26.71 Supplying, fitting and fixing 12 mm dia, 450 mm long Plastic flexible lead Tk. 65.00
(connection) pipe approved and accepted by the Engineer.
26.72 Supplying, fitting and fixing 12 mm dia, 600 mm long Plastic flexible lead Tk. 99.00
(connection) pipe approved and accepted by the Engineer.
26.73 Supplying, fitting and fixing 12 mm dia 450 mm long metal cover connection pipe Tk. 350.00
approved and accepted by the Engineer. '
PWD SoR 2014 for Civil Works 166
26.74 Supplying, fitting and fixing 12 mm dia 600 mm long metal cover connection pipe Tit 399.00
approved and accepted by the Engineer.
26.75 Construction of masonry inspection pit with 250 mm thick brick work in cement
mortar (1:4) including necessary earth work, side filling and one layer brick flat
soling, 75 mm thick (1 :3:~) base concrete for making invert channel and 12 mm thick
(1:2) cement plaster with neat finishing etc. all complete up to a depth of 700 mm
approved and accepted by the Engineer.
26.75.1 Clear 450 x 450 mm and depth 450 to 600 mm, .average 525 mm for single 150 mm. Tk. 3,433.00
dia RC.C. pipes and 400 mm PVC pipe.
26.75.2 Clear 520 x 525 mm and depth 675 to 825 mm, average 750 mm for single 225 mm Tk. 5,0·12.00
dia RC.C. pipes and 400 mm PVC pipe.
26.75.3 Clear 600 x 600 mm and depth 750 to 900 mm, average 825 mm for single 300 mm Tk. 6,882.00
dia R.C.C. pipes and 375mm and 400 mm PVC pipe.
26.75.4 Master-pit of Size: Clear 600 x 500 mm and average 750 mmdepth for Septic tank. Tk. 3,71Q.OO
26.76 Construction and placing of R.C.C. inspection pit cover (slab) in (1:2:4)"with 1%
reinforcement excluding M.H. cover wnh locking/unlocking arrangement including
necessary earth work, side filling shuttering. curing, cement plaster (1 :4) with neat
finishing on edges and top etc. all complete approved and accepted by the Engineer.
26.77 Construction and placing of R.C.C inspection pit cover (slab) with supplying and
provisions for placing, fitting, fixing 450 mm dia Col. Man-hole cover with locking/un-
locking anpngement including concrete (1 :2:4) with approx. 1% re-enforcement,
necessary earth cutting, or cleaning, side filling, curing etc. with minimum 12 mm
cement· plaster (1: 4) and neat cement finishing on edges and top all complete anq
accepted by the Engineer.
26.77.1 950 x 950 x75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. Tk. 2,371.00
26.77.2 1025 x 1025 x 75 mm RC.C. pit cover with 450 mm dia C.1. manhole cover. Til 2,534.00
26.77.3 1100 x 1100 x 75 mm RC.C "'it cover with 450 mm dia C.I. manhole cover. Tk. 2,755.00
26.78 Construction of masonry inspection pits up to a depth of 700 mm with 250 mm thick
brick work in cement mortar (1:4) including 100 mm thick R.C.C. top slab (1:2:4)
with .1% reinforcement, man-hole cover with locking arrangement including
necessary earth work, side filling and one brick flat soling. 75 mm thick {1:3:6} base
concrete for making invert channel and 12 mm thick (1 :2) cement plaster with neat
finishing etc. all complete approved and acce~<ri by the Engineer.
26.78.1 Clear 450 x 450 mm and depth 450 to 600 mm, average 525 mm for single 150 mm Tk, 5,804.00
dia R.C.C. pipes and 400 mm PVC pipe with pit cover and 450 mm diaC.I. man-hole
cover.
~ ~
PWD SoR 2014 for Civil Works 167
26.78.2 Clear 525 x 525 mm and depth 675 to 825 mm, average 750 mm for single 225 mm Tk. 7,546.00
dia RC.C. pipes and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole
cover.
26.78.3 Clear 600 x 600 mm and depth 750.to 900 mm, average 825 mm for single 300 mm Tk. .9,637.00
dia RC.C. pipes and 375 mm and 400 mm PVC pipe with pit cover and 450 mm dia
C.I. man-hole cover.
26.79 Construction of septic tank of different sizes with walls of brick work in cement
· mortar (1:6) having a lining of minimum 125 mm R.C.C cast against the walls as per
approved type plan over a brick flat soling and 150 mm thick reinforced cement
concrete flooring (1 :2:4) with 125 mm thick walls in parti~ion and 12 mm thick cement
plaster (1:4) with N.C.F. to insides of walls on floor and all around outside walls by
8
18 height at top including supplying fitting and fixing of two RC.C. Tees and
providing 450 mm dia water sealed heavy type C.I. manhole cover with
locking/unlocking arrangement and 100 mm thick RC.C (1:2:4) top slab, including
centering, shuttering, fabricating, casting and curing etc. complete up to required
depth including necessary earth work in excavation and shoring, bailing out water
and side filling including the cost of all materials, operations and incidental charges.
etc. all complete as per type plan approved and accepted by the Engineer. (Rate is
· including cost of reinforcement and its fabrication, binding and placing)
26.80 Construction of soak well of different sizes (medium and large sizes) with 250 mm
thick solid brick work and 250 mm honey comb brick work with cement mortar (1:6)
as per design over R~C.C. (1:2:4) well curb with 1% reinforcement up to the depth as
per drawing with 450 mm dia water sealed heavy type. C.1. manhole cover with
locking arrangement, filling the well up to the required depth with graded khoa and
sand including supplying and fabricating M.S. Rod, casting, curing including
necessary earth work in excavation, side filling and bailing out water including cost of
all materials. etc. all complete as per drawing, design approved and accepted by the
Engineer. (Rate is including cost of reinforcement and its fabrication, binding and
placing)
"
PWD SoR 2014 for Civil Works 168
26.81 Construction of· soak well of different sizes (small sizes) with 250 mm thick solid
brick work and 250 mm honey comb brick work with cement mortar (1 :6) as per
design over R.C.C. (1 :2:4) well curb with 1% reinforcement up to the depth as per
drawing with 450 mm dia water sealed heavy type.· C.I. manhole cover with locking
arrangement, filling the well up to the required depth with graded khoa and sand
including supplying" and fabricati~g M.S. Rod, casting, curing including necessary
earth work in excavation, side filling and bailing out water including cost of all.
materials etc. all complete as per drawing, design approved and accepted by the
Engineer.
26.82 Supplying, fitting, fixing of Reverse Osmosis Water Purifier of foreign· made for
purification of water by reverse osmosis system to have potable water confirming
WHO standard and. Bangladesh concentration parameters including installation
charge, carriage, sundries etc. complete approved and accepted by the Engineer.
(excluding cost of pipe, pipe line laying and accessories required for pipe line laying)
26.82.1 Water purification vol.: 50 Gallon /day water reserve capacity: 11 liter Tk .. 21,318.00
26.82.2 Water purification volume: 75 gallon per day (Without meter) Tk. 25,238.00
26.82.3 Water purification volume: 75 gallon per day (With meter) Tk. 26,636.00
26.82.4 Water purification volume: 100 gallon Per day Tk. 79,433.00
---_." \ .. _-----
26.83 Supply, installation and commissioning of 50 liter capacity best quality 'Water Tk. 4,391.00
Dispenser' with container of approved brand/origin.
26.84 Punching or cutting hole of any diameter for sanitary works. Tk . 666.00
. ~
PWD SoR 2014 for Civil Works 169
(Note: Tender for test & observation well must be called beforehand. Tender
for main production well will then be called on the basis of required data
obtained from the test well. Requirements of water must be guiding factor in
dimensioning the main well.
27.1 Mobilization for test boring or observation well: Transportation of materials, Tk. 7,034.00
equipments, tools and plants and boring rig to work site. Con.struction of derrick and
dismantling the same. Cleaning the site after completion of the work accepted by the .
Engineer.·
27.2 Boring by using 100 mm dia cutter and 40 mm dia heavy type G.I pipe having wall
thickness .2.9 mm, outside diameter min 47.8 mm, weight 3.517 kg/m, capability to
withstand 50 kg/cm 2 and other equipments .capable of drilling up to a depth 500 ,
meter .by water jet system through all sorts of strata. Protection of caving by ,
supplying necessary casing pipe. Collection of soil samples at every 3 meter interval
and at every change of strata and preserves them in a controlled environment for
analysis and laboratory test. Finally withdrawal of boring and casing pipes etc.
complete and accepted by the Engineer.
27.3 Installation of tube-well fixture for observation well: Supplying and lowering of
40/38 mm inside dia best quality uPVC pressure tube well pipe having specific
gravity 1.35 - 1.45, wall thickness 2.5 mm - 3.0 mm, capability to withstand a
minimum hydrostatic pressure of 170 psi for 1 hr. fitted and fixed in position with all
accessories, uPVC sand trap of length 3.00m with uPVC strainer of desired slot
installing in or at mid depth of the most suitable water bearing strata. 38 mm dia G.I.
pipe of best quality of length 1.52 mwith M.S. welded flat bar on each side to prevent
from rotation up to desired depth, fitting fixing the best quality NO.6 C.l. head hand-
pump etc including the cost of solvent cement, SOC;~f;~ adaptor, filling medium sand
up to 18.00 m above strainer and the remaining portion with available soil from
boring etc. complete as per standard specL,Jtion and accepted by the Engineer.
27.3.1 Fitting, fixing NO.6 .Hand-pump set including all necessary accessories etc complete Tk. 2,738.00
and accepted by the Engineer.
PWD SoR 2014 for Civil Works 170
27.32 38/40 mm dia heavy type G.I pipe conforming. to standard BS-1387 & BDS-1 031, Tk. 680.00
having chemical composition (in%) Carbon 0.17-0.25, Manganese 0.95-1.20,
Sulphur 0.060 max, Phosphorous 0.060 max, Tensile properties: miminum Yield
Strength 188 MPa, .minimumTensile Strength 313 MPa and marking for a)
Manufacturer b) Material c) Wall thickness d) Nominal outside dia e) Intended use
etc. on the body of the pipe having wall thickness 2.9 mm, weight 3.517 kglm
capability to withstand 50 kg/cm2 hydraulic pressure.
27.3.3 38/40 mm dia water grade uPVC pipe having wall thickness 2.5-3.00 mm Tk. 141.00
27.3.4 38/40 mm dia water grade uPVC strainer having thickness 2.5-3.00 mm Tk. 175.00
27J.7 Supplying, fitting fixing observation well inside the housing pipe of the deep tube Tk. 21,806.00
well: 100'-0" depth
27.3.8 Supplying, fitting fixing tube-well log describing technical information of the tube-well Tk. 2,859.00
as per instruction and accepted by the Engineer.
27.3.9 Filling the top 0.6 meter of the bore hole around the top pipe With sanitary seal of Tk. 51.00
concrete of proportion 1:2:4 as per design accepted by the Engineer.
27.4 Complete development of the tube well to obtain sand and turbidity free water at a
-.----_... -----
satisfactory yield confirmed by tests as . per specification and accepted by the .
Engineer. Water sample must be taken from 3 separate aquifers from three tube-
well.
27.5 "Furnishing design of a production well by testing of water and soil samples from ,j
a test bores up to 350 mdepth collecting samples of water from the best suitable
aquifer, .filling in sterilized air-tight glass bottles having no air space inside; collecting
soil (sand, solids etc) at 3m interval and at each change of soil strata from the bores,
arranging them in the cell of abox in an orderly manner. carrying out test of water for
(1) pH, (2) C02 (3) Chloride, (4) Fluoride, (5) Iron, (6) Manganese, (7) Nitrate-
Nitrogen, (8)Total alkalinity, (9) Total hardness, (10) Arsenic, (11) Turbidity, followed
by test reports along with Bangladesh Standards of potable water and' (12) Sieve
analysis on soils throughout a bore, leading to ascertain the best suitable sustained
aquifers, depths and slot sizes of strainer, types and dia of tube well for specific
yield, thickness of shrouding around strainer, fineness modulus of shrouding
materials, mechanical units (pumps, compressor) for testing and operation of the
tube well, maintaining test bore functional till tube well installation, testing etc. is
finished, finally filling and sealing the left over test bore permanentry, including
carrying water and soil samples under direct responsibility of Engineer-in-charge to
BRTC, SUET or other reputed laboratory, approved by the authority, submitting the
report and design details aD complete and accepted by the Engineer and maintaining
the mobilized tools and plant at site till satisfactory test results are found (if not, next
test bore may be executed with the approval of concern S.E.! Design Office)'
• Total No. of test on water: 11 types of test x 1 test bore x one set sample (3
specimen) = 11 Nos. test (each specimen 1.5 liter of water)
• Sieve analysis: min 9 Nos. Sample x one te-st x One bore =9 Nos. test
. (Samples are of 1 kg dry wt. each)"
There are about 55 (fifty-five) tests for potable water Quality Standard according to
Bangladesh Environment Conservation Rules-12 (Schedule-3), 1997, under ECA
1995 of Ministry of Environment and Forest. Therefore, additional test! tests on water
or sieve analYSis of soil if required, other than the above specified 12 (twelve) tests, .
--Il
may be carried out for public interest as per direction of the design engineer on
actual payment including profit, VATand all other charges.
27.6 Disinfections of the well by using minimum 3 kg of bleaching powder of 33% Tk. 380.00
strength or any other disinfectant as per standard specification and accepted by the
Engineer.
PRODUCTIO~J 'NELL
~ ~/~
PWD SoR 2014 for Civil Works 172
27.8 Preparation and making gravel pack around the tube well fixtures with supply of Tk. 3,087.00
designed graded pea gravels free from any substance harmful to pipe and health
confirmed by test (Passing through 10 mesh and retained on 40 mesh) including
sieving, washing etc. complete as per standard specification and accepted by the
Engineer. (The rate is inclusive of the cost of extra amount required for caving and
extra depth below the tube well fixtures, shrouding should not be more than 15 m
above the strainer and measurement should be allowed from bottom of the tube-well
fixture to top of the gravel pack)
27.9 Making a $anitary seal up to a minimum depth of 6 meter from G.L. or as specified Tk. 7,982.00 .
including the supply of approved quality of cement, sand and khoa' (12 mm down
graded) in ratio (1:1 :5:3) as per standard specification and accepted by the Engineer.
27.10 Boring: Execution 325 mm dia of boring through all sorts of strata by reverse
cirGUlation or any other approved.method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 325 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
__
. .. ).- .. _- of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation) .
27.11 Supplying the following tube well fixtures and pipes having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to 80S-1:2013, 4.4.1,4.4.2 at working site as per standard practice and
accepted by the Engine'er. '
27.11.2 50 mm dia water grade uPVC blind pipe/sand trap of wall thickness 2.5 to 3.00 mm 182.00
27.11.3 50 mm dia strainer of any slot as per design made with grade uPVC pipe of wall 221.IJU
thickness 2.5 to 3 mm
~ )Wn/
PWD SoR 2014 for Civil Works 173
27.11.5 125mm dia water grade uPVC Housing pipe of wall thickness 5.5 to 6.4mm Tk. 736.00
27.11.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design Tk. 364.00
27.12 Complete installation of 50 mm -dia uPVC tube well fixtures such as expanded Tk. 66.00
top or furnishing pipe, reducer, tube well pipes, strainer, blind pipe, pipe cap -etc.
fitting and fixing with best quamy PVC solution, iron screws and PVC tape, sockets
and placing in position with proper size M.S. centralizer @ 3.0 meter c!c in strainer
portion including blind pipe etc. complete -as per standard practice and accepted by
the Engineer.
27.13 Complete development of the tube well by air compressor and p·ump of suitable
capacity by alternate surging and pumping or any specified method until satisfactory
yield: is achieved in sand and turbid free-water confinned by laboratory test using
necessary quantity of cologne and conducting step drawn-clown test before and. after
the development' as per ·specification and accepted by the Engineer.
(Development should be started within 24 hoursaf completion of shrouding)
27.14 Pumping test of the well by designed turbine/submersible pump with supply of Tk. 651.00
testing equipments for pressure! velocity! discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per speCification and
accepted by the Engineer.
27.15 Disinfections of the well including supply of suffICient quantity of bleaching powder Tk. 1,106.00
(33% strength) to obtain chlorinated water having. 150 ppm free chlorine in the well
complete as per standard specification and accepted by the Engineer.
27.16 Filling of the borehole around the tube well from top of the shrouding up to the Tk. 24,r'"
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmfullo pipes and health as per standard specification and accepted
by the Engineer.
.~.
PWD SoR 2014 for Civil Works 174
27.17 Protective top cover: Supplying and fitting fixing best qualify 150 mm dia 4 mm Tk. 3,826.00
thick MS. Pipe 1.0 m (3'-4") long one end blocked with 200 mm dia 4 mm thick M.S.
plate and other end minimum 300 mm (1'-0") embedded in sanitary seal for
protection of uPVC Housing Pipe as per standard specification and accepted by the
Engineer.
27.18 . Boring: Execution 350 mm dia of boring through all sorts of strata by reverse'.'
circulation or any other approved method (Method. other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 350 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as .
required. and at every change in soil stratum including sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specification .
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom·
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siKation)
27.19 Supplying the following tube well fixtures and having density 1350 kg/m3. opacity
0.2% of visible light as per ISO 7686, minimum required strength 25 MPa conforming
to 805-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and accepted by
the Engineer.
27.19.2 75 mm dia water grade uPVC blind pipe/sand trap of wall thickness 3.5 to 4.1 mm Tk. 312.00
27.19.3 75 mm dia strainer of any slot as per design made with grade uPVC pipe of ·.~h'lI Tk. 347.00
thickness 3.5 to 4.1 mm
27.19.5 150 mm dia water grade uPVC Housing pipe having waH thickness 6.6 mm to 7.6 Tk. 953.00
mm
27.19.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design Tk. 364.00
PWD SoR 2014 for Civil Works 175
27.20 Complete installation of 75 mm dia uPVC tube-well fixtures such as expanded Tk. 74.00 . I
top pipes. Reducer, tube-well pipes, strainer, blind pipe. Pipe cap etc fitting and fixing \
with best quality uPVC solution, iron screws and uPVC tape and placing in position
with proper size M.S. centralizer @ 3 meter clc .in strainer portion including blind
pipe etc. complete as per standard practice and accepted by the Engineer.
27.21 Complete development of the well by suitable air compressor and pump of suitable
capacity by altemate surging and pumping un till satisfactory yield, sand free water
and the turbidity condition is reached using necessary quantity of calgon and
conducti.ng step draw down test before. and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.22 Pumping'~est of the well by designed turbine/submersible pump with supply of testing Tk. 807.00
equipments for pressure/ velocity/ discharge etc. and all materials for 72 hours
including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
. 27.23 Disinfections ·of the well including supply of sufficient quantity of bleaching powder Tk . 1,342.00
(33% strength)chlorinated water having 150 ppm available free chlorine complete as
per standard specification and accepted by the Engineer.
27.24 Filling of the bore·hole around the tube well from top of the shrouding up to the Tk. 28.00
bottom of sanitary seal by withdrawn selected sailor local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.25 Protective top cover: Supplying and fitting fixing best quality 200 mm dia 4 mm Tk. 5,317.00
thick M.S. pipe 1.0 m(3'-4") long one end blocked with 250 mm dia 4 mm thick M.S.
plate and other end minimum 300 mm (1'-0) embedded in sanitary seal for protection
of uPVC housing pipe as per standard specification and accepted by the Engineer.
27.26 Boring: Execution 400 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to .
be applied only for wells deepe'r t~an 152 meter) BOring for 400 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval oras
required and at every change in soil stratum including· sinking and with drawing
necessary casing pipe and all necessary arrangements complete as per specificatic. ..
and accepted by the Engineer.(Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
~ )j6;1l£V/ '
PWD SoR 2014 for Civil Works 176
27.27 Supplying the following tube well fixtures and pipes HaVing density 1350 kg/m3.
opacity 0.2% of visibJe light as per ISO 7686, minimum required strength 25 MPa
conforming to BOS-1:2013, 4.4.1, 4.4.2 at working site as per standard practice and
accepted by the Engineer
27.27.2 100 mm dia water grade uPVC blind pipe! sand trap having wall thickness 4.5mm to Tk. 472.00
5.2mm
27.27.3 100 mm dia strainer of any slot as per design made with water grade uPVC pipe Tit 507.00
having wall thickness 4.5 mm to 5.2 mm
27.27.4 Best quality 100 mm x 200 mm dia uPVC Reducer . Tk. 861.00
27.27.5 200 mm dia water grade uPVC Housing pipe having wall thickness 6.6mm to 7.8mm TIc 804,00
t09.0mm
27.27.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design Tk. 364.00
27.28 Complete installation of 100 mm dia uPVC tUbe-well fixtures such as expanded . tk, 85~00
1.
" top pipes. Reducer, tube-well pipes. Strainer, blind pipe, pipe cap etc. fitting and
fixing with best quality PVC solution, iron screws and uPVC tape and placing in
position with proper size M.S. centralizer @ 3 meter c/c. in strainer portion including
blind pipe etc. complete as per standard practice and accepted by the Engineer.
·27.29 Complete development of the tube-well by air compressor and pump of suitable
capacity by alternate surging and pumping until satisfactory yield, sand· free water
. and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer.(Oevelopment should be started within
24 hours of completion of shrouding)
27.30 Pumping test· of the well by designed turbine/submersible pump with supply of Tk. 852.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours fncluding yield drawn and recovery test etc. complete as per specification and
. accepted by the Engineer.
27.31 Disinfections of the well including supply of sufficient quantity of bl~aching powder Tk. 1,579.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
,, complete as per standard specification and accepted by the Engineer.
~ ~
PWD SoR 2014 for Civil Works 177
27.32' Filling of the borehole around the tube-well from top of the shrouding up to the Tk. 32.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.33 Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm Tk. 8,468.00
thick M.S. pipe. 1.0 m (3'-4") long one end blocked with 300 mm dia 4 mm thick M.S.
plate and other end minimum 300 (1'-0") embedded in sanitary seal for protection of
uPVC Housing pipe as per standard specification and accepted by the Engineer.
27.34 Boring: Execution 600 mm dia of boring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter). Boring for 600 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval or as
required and at every change in soil stratum including sinking and with drawing
necessary casing ~pe and all necessary arrangements complete as per specificat!on
and accepted by the Engineer. (Measurement will be allowed from E.G.L. to bottom
of the blind pipe and the rate is inclusive of the cost of extra depth or of further boring
required due to caving and siltation)
27.35 Supplying the foUowing tube-well fixtures and pipes having density 1350 kg/m3,
opacity 0.2% of visible light as per ISO 7686, minimum required strength 25 MPa
conforming to BDS-1 :2013, 4.4.1. 4.4.2 at working site as per standard practice and
accepted by the Engineer.
27,35.1 Best quality 150 mm dia uPVC cap for blind pipel sand trap. 473.00
27.35.2 150 mm dia water grade uPVC blind pipel sand tr having wall thickness 6.6 mm Tk. 1,042,00
t07.6 mm
27.35.3 150 mm dia strainer of any slot as per design made with'grade uPVC pipe of wall Tk. 1,086.00
thickness 6.6 to 7.6 mm
27.35.4 Best quality 150 mm x 200 mm dia uPVC Reducer Tk. 999.00
27.35.5 200 mm dia water grade uPVC Housing pipe of wall thickness 6.6 mm to 7;8 mm Tk. 1,668.00
27,35.6 Supplying centralizer made with 12 mm dia M.S. rod of approved design Tk. 364.00 ~ "
~ )J6M/
PWD SoR 2014 for Civil Works 178
27.36 Complete installation of 150 mm dia uPVC tube-well·fixtures such as expanded Tk. 90.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
with best quality uPVC solution, iron screws and uPVC tape and placing in position
with proper size M.S. centralizer @3meter clc in strainer portion including blind pipe
etc. complete as per standard practice and accepted by the Engineer.
27.37 Complete development of the tube well by suitable air compressor and pump of
. suitable capacity by aHernate surging and pumping until satisfactory yield, sand free
water and the turbidity condijion is reached using necessary quantity of calgon and
condu~tingstep draw down test before and after the development as. per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.38 Pumping test of the well by designed turbine/submersible pump with supply of Tk. 973.00
testing equipments for pressure! Velocity! discharge etc. and all materials for 72
hours including ·yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.39 Disinfections of the well including supply. of sufficient quantity of bleac~ing powder Tk. 1,895.00
(33% .strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer
27.40 Filling of the borehole around the tube well from top of the shrouding up to ·the Tk. 43.00
bottom of sanitary seal by withdrawn selected. soil or local clay as free from any -.-"
."
substances harmful to pi pes and health per stand ard specification. and accepted by
"J
/'.
c -----
the Engineer.
27.41 Protective top cover: Supplying and fitting fixing best quality 250 mm dia 4 mm Tk. 8,343.00
thick M.S. pipe 1.0 m (3'-4") long one end blocked with 300 dia 4 mm thick M.S. plate
and other end minimum 300 (1'·0') embedded in sanitary seal for protection of iJPVC
HOUSing pipe as per standard specification and accepted by the Engineer.
27.42 Boring: Execution of 600 mm diaboring through all sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to .
be applied only for wells deeper than 152 meter) for boring 600 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G. L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.42.1 From 0.0 mto 50 m= 50 m Tk. 1,020.00
27.42.2 From 50 mto 100 m=50 m Tk. 1,173.00
27.42.3 From ~OO rr. :."'1152 m =52 m Tk. 1,349.00
27.42.4 From 152m to 200 m=48 m Tk. 1,551.00
I '
27.42.5 From 200 mto 250m =50 m Tk. 1,783.00
@ )Gm/
PWD SoR 2014 for Civil Works 179.
27.43.3 150 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
27.43.3.1 Stainless steel strainer of continuous slot having weight 28.84 kg per meter. Tk. 14,871.00
27.43.3.2 2.50 mm thick stainless steel Bridge type strainer. Tk. 10,700.00
27.43.4 150 mmx 300 mm dia M.S. reducer of minimum thickness of 6 mm. Tk. 3,510.00
27.43.5 300 mm dia 6 mm minimum thick M.S. housing pipe (Welded) Tk. 6,197.00
27.43.6 300 mm dia 6 mm minimum thick M.S. housing pipe (Seamless) Tk. 9,970.00
27.43.7 Centralizer made with 12 mm dia M.S. rod of approved design. Tk. 364.00
V<
27.43.8 350 mm dia M.S. cap having 6mm thick for housing pipe covering. Tk. 2,036.00
27.44 Complete installation of 150 mm dia deep tube-well fixtures such as expanded Tk. 351.00
top pipes, reducer. tube-well pipes, strainer, blind pipe. pipe cap etc. fitting and fixing
socket, welding and additional welding with fibre and placing in position with proper
size M.S. centralizer @ 3 meter c/c in strainer portion including. blind pipe etc.
complete as per standard practice and accepted by the Engineer.
27.45 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw dtlwn test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of cor. 'etion of shrouding)
27.45.1 Wells up to 200 mdepth Tk. 41,814.00
27.46 Pumping test of the well by ~'Jsigned turbine/submersible pump with supply of Tk. 1,002.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
> I
~ JJ&~
PWD SoR 2014 for Civil Works 180
27.47 Disinfections of the well including supply of sufficient quantity of bleaching powder Tit 1,935.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.48 Filling of the borehole around the tube well from top of the shrouding up to the Tk. 43.00
bottom of sanitary seal by withdrawn selected sailor local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.49 Boring:· Execution of 800 mm dia boring through all sorts of strata by reverse
circulation or any other approved. method (Method other than reverse circulation is
to be applied only for wells deeper than .152 meter). For boring 800 mm dia vertical
hole up to designed depth. and collection of soil samples at every 3 meter interval
and at every change of formation including sinking and withdrawing necessary
casing pipe and all necessary arrangements complete as per specification and
accepted by the Engineer. (Measurement will be allowed form G.L. to bottom of the
blind pipe and the rate is required for caving and siltation)
27.50 Supplying the following tube-well fixtures and pipes conforming to standard BS-
1387 & 80S-1031; having chemic'al composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength ·188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal· outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.50.1 200 mm dia M.S. cap Smm thick for blind pipe! sand strap Tk. 1,581.00
27.50.2 200 mm dia 6 mm thick tube well pipe and blank G.I. pipe of wt. 33.45 kg per meter Tk. 7,005.00
can withstand minimum 700 psi hydraulic pressure
27.50.3 200 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm·
dia M.S. rod continuously.
27.50.3.1200 mm dia stainless steel strainer of continuous slot having 38.36 kg per meter. Tk. 16,973.00
I'
PWD SoR 2014 for Civil Works 181
27.50.3.2 200 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 10,940.00
27.50.5 400 mm dia 6 mm thick M.S. housing pipe (Welded) .Tk. 10,977.00
27.50.6 400 mm dia 6 mm thick M.S. housing pipe (Seamless) Tk. 13,409.00
27.50.7 Centralizer made with 12 mm dia M.S. rod of approved design Tk. 364.00
27.50.8 450 mm dia M.S. cap of 6 mm thick for housing pipe covering. Tk. 1,977.00
27.51 Complete.i~stallation of 200 mm dia deep tube well fixtures such as expanded Tk. 383.00
top pipes, reducer, and tube well pipes, strainer, blind pipe. Pipe cap etc. Fitting and
fixing socket, welding and additional welding with fibre and placing in position with
proper size M.S. centralizer @ 3 meter clc in strainer position including blind pipe
etc. complete as per standard practice and accepted by the Engineer.
27.52 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the' turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within ·
24 hours of completion of shrouding). ~'
27.53 Pumping test of the well by designed turbine!submersible pump with supply of testing Tk. 1,044.00
equipments for pressure! velocity! discharge etc. and all materials for 72 hours
including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.54. Disinfections of the well including supply of sufficient quantity of bleaching powder Tk. 2,211.00
(33% strength) chlorinated water having 150 ppm avaHable free chlori/lcl complete as
per standard specification and accepted by the Engineer.
27.55 Filling of the borehole around the tube well from top of the shrouding up to the T~. 43.00
bottom of sanHary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
J,
~
PWO SoR 2014 for Civil Works 182
27.56 Boring: Execution of 325 mm dia boring through all sorts of strata by reverse
circulation or any other approved method. (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 325 mm dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer.{Measurement will be allowed fromG.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.57 Supplying the following tube·well fixtures and pipes conforming to standard BS-
1387 & 80S-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
----------," _.----
and marking for a) Manufacturer b) Material c) Wall.thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.57.1 150 mm dia 6mm thick M.S. cap for blind pipe! sand trap. Tk~ 1,213.00
27.57.2 50 mm dia 4.85 mm thick tube well pipe and blank GJ pipe Tk. 851.00
27.57.3 50 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia
M.S. rod continuously.
27.57.3.1 50 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter. Tk. 5,782.00
27.57.3.2 50 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 5,782.00
27.57.5 150 mm dia 6 mm thick M.S. housing pipe (Welded). rk. 3,210.00
27.57.6- 150 mm dia 6 mm thick M.S. housing pipe (Seamless). Tk. 3,317.00
27.57.7 Centralizer made with 12 mm dia M.S. rod of approved design. Tk. 364.00
27.57.8 150 mm dia M.S. cap of 6 mm thick for housing pipe covering. Tk. 1,54~ ·')0
/'
PWD SoR 2014 for Civil Works 183
27.58 Complete installation of 50 mm dia deep tube-well fixtures such as expanded Tk. 351.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
socket, welding and additional welding with fibre and placing in position with proper
size M.S.centralizer @ 3 meter c/c in strainer portion including. blind pipe etc.
complete as per standard practice and accepted by the Engineer
27.59 Compete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.60 Pumping test of the well by designed turbine/submersible pump with supply of Tk. 839.00
testing equipments for pressure/ velocity/ discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.61 Disinfections of the well including supply of sufficient quantity of bleaching powder Tk·. 1,106.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.62 Filling of the borehole around the tube well from top of the shrouding up to the Tk. 25.00
bottom of sanitary seal by withdrawn selected soil or local day free from any
substances harmful to pipes' and health as per standard specification and accepted
by the Engineer.
27.63 Boring: Execution of 350 rnm dia boring through a/l sorts of strata by reverse
circulation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 350 mm dia vertical hole
up to designed depth and col/ection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.64 Supplying the following tube-well fixtures and pipes conforming to standard BS-
1387 & BOS-1031, having chemical composition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe at working site as per standard practice
and accepted by the Engineer.
27.64.1 150 mm dia 6mm thick M.S. cap for blind pipel sand trap. Tk. 1,209.()0
27.64.2 75 mm dia 4.85 mm thick tube well pipe and blank G.I. pipe Tk. 1,328.00
27.64.3 75 mm dia strainer of slot opening as per design including tagging 4 Nos. 12 mm dia
M.S. rod continuously.
27.64.3.1 75 mm dia stainless steel strainer of continuous slot having 28.84 kg per meter. Tk. 7,753.00
27.64.3.2 75 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 7,753.00
27.64.5 150 mm dia 6mm thick M.S. housing pipe (Welded) Tk. 3,210.00
27.64.6 150 mm dia 6mm thick M.S. housing pipe (Seamless) Tic ..3,~17.00
- . -...- .. -
27.64.7 Centralizer made with 12 mm dia M.S. rod of approved design Tk. 364.00
27.64.8 150 mm dia M.S. cap of 6 mm thick for housing pipe covering. Tk. 1,542.00
27.65 Complete installation of 75 mm dia deep tube-well fixtures such as expanded Tk. 341.00
top pipes, reducer, tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and fixing
socket,' welding and additional welding with fibre and placing in position with proper
size M.S. centralizer @ 3 meter c/c in strainer portion including blind pipe etc.
complete as per standard practice and accepted by the Engineer.
27.66 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding)
27.67 Pumping test of the well by designed turbine/submersible pump with supply of Tk. 897.00
testing equipments for pressure! velocityl discharge etc. and all materials for 72
hours including yield drawn and -recovery test etc. complete as per specification and
accepted by the Engineer.
27.68 Disinfections of the well including supply of sufficient quantity of bleaching powder Tk. 1,342.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
comPlete as per standard specification and accepted by the Engineer.
27.69 Filling of the borehole around the tube well from top of the shrouding up to the - Tk. 29.00
bottom of. sanitary seal by withdrawn selected soil or local clay free from any
substances harmful to pipes and health as per standard specification and accepted
by the Engineer.
27.70 Boring: Execution of 400 mm dia boring through all sorts of strata by reverse
circl.dation or any other approved method (Method other than reverse circulation is to
be applied only for wells deeper than 152 meter) for boring 400 mrn dia vertical hole
up to designed depth and collection of soil samples at every 3 meter interval and at
every change of formation including sinking and withdrawing necessary casing pipe
and all necessary arrangements complete as per specification and- accepted by the
Engineer. (Measurement will be allowed from G.L. to bottom of the blind pipe and the
rate is inclusive of the cost of extra depth of boring required for caving and siltation)
27.71 Supplying the fol1owing tube-well fixtures and pipes conforming to standard BS-
1387 & 80S-1031, having chemical compOSition (in%) Carbon 0.17-0.25,
Manganese 0.95-1.20, Sulphur 0.060 max, Phosphorous 0.060 max, Tensile
properties: miminum Yield Strength 188 MPa, minimumTensile Strength 313 MPa
and marking for a) Manufacturer b) Material c) Wall thickness d) Nominal outside dia
e) Intended use etc. on the body of the pipe ~t working site as per standard practice
-and accepted by the Engineer.
27.71.1 Supplying 150 mm 6mm thick M.S. cap for blind pipe/ sand trap. Tk. 1,213.00
- 27.71.2 SuppMng 100 mm dia 6 mm thick tube well pipe and blank G.!. pipe Tk. 1,780.00
27.71.3 100 mm dia strainer of slot op~ning as per design including tagging 4 Nos. 12 mm
dia M.S. rod continuously.
~
PWD SoR 2014 for Civil Works 186
27.71.3.1 Supplying 100 mm dia stainless steel strainer of continuous slot having 28.84 kg per Tk. 6,994.00
meter.
27.71.3.2 Supplying 100 mm dia 2.5 mm thick stainless steel bridge type strainer Tk. 6,994.00
27.71.4 Supplying 100 mm x' 200 mm dia 6mm thick M.S. reducer. Tk. 5,626.00
.27.71.5 Supplying 200 mm dia 6 mm thick M.S. housing pipe (Welded) Tk. 3,631.00
27.71.6 Supplying 200 mm dia 6 mm thick M.S. housing pipe (Seamless) Tk. 3,992.00
27.71.7 Supplying centralizer made with 12 mm pia M. S. rod of approved design Tk. 210.00
27.71.8 Supplying 200 mm dia M.S. cap of 6 mm thick for housing pipe covering. Tk. 2,150.00
27.72 Complete installation of 100 mm dia deep tube-well fixtures such as expanded Tk. 383.00
top pipes, reducer, and tube-well pipes, strainer, blind pipe, pipe cap etc. fitting and
fixing socket, welding and additional welding with fibre and placing in position with
proper size M.S. centralizer @ 3 meter clc in strainer portion including blind pipe etc.
complete as per standard practice and accepted by the Engineer.
27.73 Complete development of the tube well by suitable air compressor and pump of
suitable capacity by alternate surging and pumping until satisfactory yield, sand free
water and the turbidity condition is reached using necessary quantity of calgon and
conducting step draw down test before and after the development as per
specification and accepted by the Engineer. (Development should be started within
24 hours of completion of shrouding) .
27.74 Pumping test of the well by designed turbine/submersible pump with supply of Tk. 939.00
testing equipments for pressurel velocityl discharge etc. and all materials for 72
hours including yield drawn and recovery test etc. complete as per specification and
accepted by the Engineer.
27.75 Disinfections of the well including supply of sufficient quantity of bleaching powder Tk. 1,579.00
(33% strength) chlorinated water having 150 ppm available free chlorine etc.
complete as per standard specification and accepted by the Engineer.
27.76 Filling of the borehole around the tube well from top of the shrouding up to the Tk. 32.00
bottom of sanitary seal by withdrawn selected soil or local clay free from any .
substances harmful to pipes ~f'l1 health as per standard 'specification and accepted
by the Engineer. .
27.77 Supplying and sinking 40 mm dia water grade uPVC tube well pipe having wall
thickness 2.5 mm to 3.0 mm including trial boring and with all necessary fittings as
required etc. all complete and accepted by the Engineer.
~ )Wvu/
PWO SoR 2014 for Civil Works 187
27.78 Supplying and sinking· 3 m long uPVC strainer with all necessary fittings as Tk. 486.00
required etc. complete and accepted by the Engineer.
27.79 Supplying, fitting and fixing· No. 6 pump for 40 mm. dia tube well with a/l Tk. 931.00
necessary fittings including 0.61 m long 40 mm dia G./. Pipe etc. all complete as per
accepted by the Engineer.
27.80 Construction of platform of size 1.4 mx 1.0 mand outlet drain up t01 meter long, Tk. 4,552.00
as per drawing with 75 mm thick cement concrete of fc min 17MPa with brick chips
and cement content relates to 1:2:4, over a brick flat soling and providing 125 mm x
75mm brick band in 1:6 all around, including .finished with 12 mm thick cement .
plaster in 1:4 followd by neat cement finishing all complete and accepted by the
Engineer..
27.81 Supplying and sinking uPVC, uPVC tube well pipe, strainer including trial boring
having density 1350 kg/m 3, opacity 0.2% of visible light as per ISO 7686, minimum
required strength 25 MPa conforming to BDS·1 :2013, 4.4.1, 4.4.2 with all necessary
fittings as required etc. a/l complete and accepted by the Engineer.
27.81.1 50 mm dia water grade uPVC pipe having wall thickness 2.5 mm to 3 mm Tk. 405.00
27.81.2 40 mm dia water grade uPVC pipe having wall thickness 2.5 mm to 3 mm Tk. 225.00
27.82 Supplying, fitting and fixing deep set tube well pump (Hand set) with all necessary Tk. 5,808.00
fittings as required such as No.6 pump, 50 mm dia G.I. pipe 0.61 m long, 50 mm x
40 mm reducing socket, 40 mm dia pipe Nipple 1.22 m long cylinder, Tie foot ball, tie
plunger, 3 Nos. 10 mm dia socket, 4 Nos. 10mm dia nuts, 5 Nos. end threaded 10
mm dia M.S. rod 3 mlong, necessary quantity of solution and tape etc. complete and "
accepted by the Engineer.
"
1
PWD SoR 2014 for Civil Works 188
28.1 Pipe line installation: Installation of 50 psi, API, 5L, Grade-B, ERW Natural pipe line :t'/:::;~~i;;;!E;'pq;);'
for supplying Titas Gas including, supplying, fitting, fixing and laying different sizes
M.S. pipes with necessary tape and primer including. cutting trenches (450 x 910
mm) in all kinds of soil, cleaning, cutting, applying coal-tar, wrapping the pipes and
back filling the trenches, excavating earth including. leveling, dressing and removing
excess. earth in all· respect as per specification of Titas Gas T and 0 Co. pd. and
accepted by the Engineer.[Rate is excluding the cost of welding and back filling with
sand at the bottom by 300 mm in thick (compacted)] .
(Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation, Ministry of
Industries, Government of Bangladesh shall be given priority)
28.1.1 75 mm N.D (88.90 mm D.D) M.S pipe, weight min 8.3 kg/m, standard test pressure Tk. 1,509.00
176 kg/ m2, wall thickness min 11.29 mm
28.1.2 50 mm N.D. (60.30 mm D.D) M.S pipe, weight min 5.44 kg/m, standard test pressure Tk. 972.00
176 kg/ m2, wall thickness min 3.91 mm
28:1.3 25 mm N.D. (33.40 mm D.D) M.S pipe weight min 2.50 kg/m, standard test pressure Tk.· 728.00
50 kg/ m2, wall thickness min 3.38 mm
28.1.4 20 mm N.D. (26.70 mm D.D) M.S pipe weight min 1..68 kg/m, standard test pressure Tk. 418.00
50 kg/ m2, wall thickness min 2.87 mm
:;.~~
28.2 Back filling the trenches with sand (F.M 0.8) in 150 mm layer, compaction each Tk. 644.00
layer up to finished level as per standard practice and accepted by the Engineer.
:
:!
28.3 Providing Butt welded joints with pipes to Tees, Elbows, Saddles, end caps etc
above or below ground including. cutting and V-leveling in each end of the pipe,
grinding by machine etc. complete as per specification of Titas Gas T and 0 C Ltd.
and accepted by the Engineer.
28.4 Supplying, fitting and fixing the following materials includi •. ;j carriage to the work site
from Titas Gas Store as per specification of Titas Gas (T and D) Co. Ltd. and
accepted by the Engineer. (Rate is excluding the cost of welding)
C!
PWD $oR 2014 for Civil Works 189
28.5 Supplying, welding, fitting and fixing of different sizes Valve Teel Service Tee to
connect the pipe line with the Titas Gas Main pipe line etc. all complete in all respect
as per specification of Titas Gas T and 0 Co. Ltd. approved and accepted by the
Engineer.
28.5.1 50 mm x 50 mm Valve Tee (2" and above 2" low pressure line) Tk. 20,427.00
28.6 Supplying, fitting and fixing in position different dia IIF (Insulated Flange) etc .all Tk. 6,609.00 ~/
complete in all respect as per specification of Titas Gas T and D Co. ltd. approved
and accepted by the Engineer. 50 mmN.D. (60.30 mmO.D) Insulation Flange.
28.7 COristructron of 1520 x 1520 x 1370 (depth) mm water-tight valve pit, enclosed by Tk. 63,844.00
250 mm thick brick wall in 1:6, plastered on each face in 1:4 with net cement
finishing, having a75 mm thick C.C (1:3:6) bed upon a layer of brick flat saling, over
laid by 38 mm thick patent stone flooring including standard M.S. sheet valve pit
cover as per drawing and specification of rrtas Gas T and 0 Co. Ltd. etc. all
complete in all respect and accepted by the Engineer.
28.8 Testing and purging the pipe lines properly as per specification of Titas Gas T and Tk. 24.00
o Co. Ltd. and accepted by the Engineer.
28.9 Supplying, fitting and fixing ball valve class 150 RF including supplyir.g :)f 2 Nos.
flange along with necessary nuts and bolts welding the flange etc. all complete in all
respect as per specification of Titas Gas T and 0 Co. Ltd. appr", .dd and accepted by
the Engineer
28.9.1 50 mm ball valve class 150 RF. 2" dia Tk, 15,511.00
28.10 Cutting permanent pucca (rigid/flexible) road and mending good the damages
etc. all complete in all respect and accepted by the Engineer.
~
PWD SoR 2014 for Civil Works 190
28.11 Installation of Domestic or Commercial House line for supplying Titas Gas
including supplying, fitting and fixing in position different dia best quality G.\. Pipe
(NT or equivalent) along with all necessary G.I. Fitting and accessories, cutting
trenches, walls and ftoors etc. and back filling the trenches, restoring walls and floors
etc. all complete in all respect as per specification of Titas Gas T and DCo. Ltd. and
accepted by the Engineer.
28.12 Supplying, fitting and fixing in position different dia one-way brass stop cock (best
quality and heavy type) etc. complete in all respect as per specification of Titas Gas
T and D Co. Ltd. approved and accepted by the Engineer.
28.13 Testing and purging the house line properly as per specifications Titas Gas T and Tk. 16.00
oCo. Ltd. and accepted by the Engineer.
··-···----'i .'----
....
29.1 Supplying anti·termite chemicals named OURS BAN 20 EC and mixing the same Tk. 204.00
with pure water in required proportion (For DURSBAN 20 EC I Ltd. in 19 liters of
pure water) and spraying the emulsified mixture @ 5 liters per square meter of soil
surface by chemical sprayer or by any other means to the sides and bottom of the
foundation trench and over plinth filling or floor bed accepted by the Engineer.
29.2 Extra cost for supplying anti termite chemicals named OURS BAN 20 EC and Tk. 1,501.00
mixing the same with pure water as per specification in item No. ·1 and using the
same emulsified water as mixing water. in cement-sand mortar of brick works in
foundation and up to plinth and accepted by the Engineer.
29.3 Supplying anti-termite chemicals named OURS BAN 20 EC and mixing the same Tk. 305.00
with pure water as per specification in ~em No.1 and spraying the emulsified mixture
with hand sprayer over both outside and inside back fill in foundation trenches
@ 7.50 liters per sqm of the vertical surface area of the foundation wall accepted by .
the Engineer. (The maximum depth of the back fill to be treated is 500 mm. and the
measurement for depth should not be given more than 500 mm)
29.4 Anti·termite treatment in existing super structures by making downwardly Tk. 39.00
slanting holes at a required depth of 9- from the existing finished F.UG.L inside and
. outside the building and· applying the emulsion of anti termite chemicals, named
DURS BAN 20 EC into the holes preparing chemical solution mixing with water at the
ratio of chemical: water =. 1: 19 maintaining a 'dosage rate of 250 ml per hole
induding supplying all materials and repairing the holes all complete and accepted
by !he Engineer.
29.5 Trench treatment for protection against incoming termites to the establishment Tk; 202.00
through underground by making trench around existing building Istructuresat a
required depth of 750 mm from existing level supplying anti-termite chemicals named
OURS BAN 20 EC preparing the solution to be mixed with water in the ratio of
chemical: water = 1: 19 appl~ng the solution into trench with the help of a chemical
sprayer in three layers and each layer follows a 250 mm thick back-fill in trench etc
. all complete and accepted by the Engineer.
29.6 Fumigation treatment (Pest Control) against mosquitoes, flies, bees, cockroaches, Tk. 15.00
spiders, silver fishes, lizards and other common pests and insects in wooden walls,
bricks walls, floors, doors and windows, furniture fanlight, carpets, records, curtains,
electrical conduits etc. with the application of fumigants such as Syngeata or .,. ;,. . c,:·.,:' ...."..:" . . ·.',:',·. ':.'"'.
NEOCIDOL-60 EC or similar chemically equivalent govt. registered pest control "(::;:c<'i·,. :.;:,·····
products preparing chemical solution mixing with water in the ratio of chemical: water
= 1:100 appl~ng with the help of electrically/mechanically operated jet fogging . ···/'·<.'.. ,:··;,,··,.;·;·.i:.,:·,··
machine, swing fog, dyna fog, pneumatic hand sprayer, knap sac hand sprayer in
air-tight position, After fumigation the surface will be kept remain at air-tight condition
at least for 3 (three) hours etc. complete and accepted by the Engineer. .
(Volume of the room will be considered towards measurement.)
29.7 Anti tennite treatment of all wooden doorframes, window frames, wood Tk. 148.00
paneling etc by using DURS BAN 20 EC emulsion in the ratio of 1liter. DURS BAN
.
20 EC + 19 liters of Kerosene oil suitable for wood, plywood, particle board, hard N~ ~;:':,~'.i;,,,;.,;~:,1';:{ •.
board etc. on both surfaces by brush on both surfaces by brush-on-method etc.
complete and accepted by the Engineer.
PWO SoR 2014 for Civil Works 192
29.8 Anti-tennite treatment of electric telephone wiring system by inserting a plugging Tk. 235.00
materials (cotton, foam etc.) soaked in anti-termite chemical DURS BAN 20 EC to an
electric switch board point for all floors and spraying the emulsion (to be mixed at the
ratio of 1 liters DURS BAN 20 EC + 19 liter of water) to the casings and grooving of
electric wirings, telephone cables utility pipes etc. for all floors etc. complete and
accepted by the Engineer.
29.9 .Destruction of termite nest around an infested building, tree stumps in lawn with the Tk. 1,474.00
treatment of OURS BAN 20 EC by excavation of soil in affected area up to a depth of
1.5meter, mixing the DURS BAN 20 EC solution to be mixed with water in 1:19 ratio
with the soil and laying the same· in same place etc. all complete as per direction
including. cost of all materials and chemicals etc. complete and accepted by the
Engineer.
30.1 70 mm thick partition wall excluding plaster .thickness with Concrete Hollow block
having compressive strength of 4.14-SN/mm2 of size (390 x 70 x 190) mm in
compliance with ASTM C129, fairly uniform thickness and texture and individual
Block shell thickness should not be less than 16 mm, water absorption 'not more than
7%,laying with 8-10 mm thick mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M) filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.1.2 Add for each addl. floor up to 5th floor Tk. • 24.82
30.1.3 Add for each addlfloor for 6th floor to 9th floor Tk, 33.10
30.1.4 Add for each addl floor for 10th floor and above Tk. 41.37
30.2 70 mm thick partition wall excluding plaster thickness with Concrete Hollow block
having compressive strength of 4.14-SNlmm2 of size (390 x 70 x 190) mm
compliance with ASTM C129, thickness of individual Block shell should not be less
than 16 mm, water absorption not more then 7 % iying with 8 to 10 mm thick mortar
(with admixture) of cement and sand in ratio 1:6 (sand not less than 1.2 F.M)
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min 3(three) days on mortar joints by jute/brush
in wet followed by imperviouslwet covering for another 4 (four) days etc all complete
and accepted by the Engineer.
30.2.2 Add for each add!. floor up to 5th floor Tk. 24.82
30.2.3 Add for each addl floor for 6th floor to 9th floor Tk. 33.10
30.2.4 Add for each addl floor for 10th floor and above Tk. 41.37
30.3 90 mm thick partition wall wnh Concrete Hollow block having strength of
4. 14-SN/mm2of size (390 x 90 x 190) mm in compliance with ASTM C129, thickness
of individual Block shell should not be less than 16 mm, water absorption not more
then 7%, lying with specified mortar (with admixture) of cement, lime and sand in
ratio 1:1:6 ($.and not less than 1.2 F.M), filling the interstices with mortar and making
bond with ~nnecting walls including necessary scaffolding and curing for min 3
(three) days~:'on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another 4( four} days curing etc all complete and accepted by the
Engineer.
30.3.2 Add for each add!. floor up to 5th floor . Tk. 24.82
PWD SoR 2014 for Civil Works 194
30.3.3 Add for each addl floor for 6th floor to 9th floor Tk. 33.10
30.3.4 Add for each addl floor for 10th floor and above Tk. 41.3.7
30.4 90 mm thick partition wall with Concrete Hollow block having compressive strength
of 4.14-SN/mm2 of size (390 x 90 x 190) mm in compliance with ASTM C129,
thickness of individual Block shell should not be less than 16 mm, water absorption
not more than 7%, lying with specified mortar (with admixture) of cement, and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute !brush in wet, followed by impervious Iwet
covering for another 4 (four) days curing etc. all complete and accepted by the
Engineer. .
30.4.2 Add for each add!, flooT up to 5th floor Tk. 24.82
30.4.3 Add for each addI floor for 6th floor to 9th ·floor Tk. 33.10
30.4.4 Add for each addl floor for 10th floor and above Tk. 41.37
30.5 140 mm thick load bearing wall with Concrete Hollow block having compressive.
strength of 13~18N/mm2 of size (390 x140 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less then 25 mm, water absorption
not more than 7%,. laying with mortar (with admixture) of ceVlent, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute !brush in wet, followed by impervious Iwet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.5.2 Add for each add!. floor up to 5th floor Tic 33.10
30.S.3 Add for each addl floor for 6th floor to 9th floor Tit 41.37
30.5.4 Add for each addl floor for 10th floor and above 11c 49.65
30.6 140 mm thic~ partition wall with Concrete Hollow block having compressive
strength of 4.14-SN/mm2 of size (390 x 140 x 190) mm in compliance with ASTM
C129, thickness of individual Block shell should not be less than 16 mm, water
absorption not more than 7%, laying with specified· mortar (with admixture) of
cement and sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with
mortar and making bond with connecting walls including rll~vessary scaffolding and
curing for min 3 (three) days on mortar joints hv jute Ibrush in wet, followed by
impervious Iwet covering for another 4( four) udyS curing etc all complete and
accepted by the Engineer.
30.6.2 Add for each add!, floor up to Sth floor Tk. 33.10
30.6.3 Add for each addl floor for 6th floor to 9th floor Tk. 41.37
30.6.4 Add for each addl floor for 10th floor and above Tk. 49.65
(!{
PWD SoR 2014 for Civil Works 195
30.7 140 mm thick load 'bearing wall with Concrete Hollow block having compressive
strength of 13"'18N/mm2 of size (390 x 140 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less then 25 mm, water absorption .
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3(three) days on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
30.7.2 Add for each addl. floor up to 5th floor Tk. 33.10
30.7.3 Add for each add I floor for 6th floor to 9th floor Tk. 41.37
30.7.4 Add for each addl. floor for 10th floor and above Tk. 49.65
30.8 140 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13-18 N/mm2 of size (390 x140 x 190) mm in compliance with ASTM
e90, thickness of individual Block shell should not be less than 25 mm, water
absorption not more than 7%, laying with mortar (with admixture) of cement and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
. min 3 (three) days on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another 4 (four) days etc all complete and accepted by the Engineer.
(rate is excluding the cost of grouting and reinforcement)
30.8.2 Add for each add!, floor up to 5th floor Tk.. 33.10
30.8.3 Add for each addl floor for 6th Hoar to 9th floor Tk. 41.37
30.8.4 Add for each addl floor for 10th floor and above Tk. 49.65
30.9 190 mm thick toad bearing wall with Concrete Hollow block having compressive
strength of 4.14-5 N/mm 20f size (390 x 190 x 190) mm compliance with ASTM C90,
thickness of individual Block shell should not be less than 25 mm, water absorption
not more than 7%, laying with mortar (with admixture) of cement, lime and sand
in ratio 1:1:6 (sand not less than 1.2 F.M), filling the interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another' 4 (four) days etc all complete and accepted by the Engineer.
(rate is excluding the cost of grouting and reinforcement)
30.9.2 Add for each add!, floor up to 5th floor Tk. 41.37
30.9.3 Add for each addl floor for 6th floor to 9th floor Tk. 49.65
30.9.4 Add for each addI floor for 10th floor and above Tk. 57.92
PWD SoR 2014 for Civil Works 196
30.10 190 mm thick load bearing wall with Concrete Hollow block having compressive
strength of 13... 18 N/mm2 of size (390 x 190 x 190) mm in compliance with ASTM
C90, thickness of individual block shell should not be less than 25 mm, water
absorption not more than 7%, laying with mortar (with admixture) of cement and
sand in ratio 1:6 (sand not less than 1.2 F.M), filling the. interstices with mortar and
making bond with connecting walls including necessary scaffolding and curing for
min 3 (three) days on mortar jOints by jute !brush in wet, fol/owed by impervious /wet
covering for. another 4 {four} days etc all complete and accepted by the Engineer.
(Rate is excluding cost of grouting and reinforcement)
30.10.2 Add for each addl. floor up to 5th floor· Tk. 41.37
30.10.3 Add for each addl floor for 6th floor to 9th floor Tk. 49.65
30.10.4 Add for each addl floor for 10th floor and above Tk. 57.92
30.11 Supplying, carrying and placing of (600 x 200 x 150) mm concrete ceiling block on
properly leveled shutter accepted by the Engineer.
30.11.2 Add for each addl. floor up to 5th floor Tk. ~3.08
30.11.3 Add for each addl floor for 6th floor to 9th floor Tk. 184
30.11.4 Add for each addl floor for 10th floor and above Tk. 4·.Q;}
.... ..
", ,~.
30.12 Supplying, carrying and placing of (600 x 200 x200) mm concrete ceiling block on
properly leveled shutter accepted by the Engineer
30.12.2 Add for each addl. floor up to 5th floor Tk. 3.84
30.12.3 Add for each addl floor for 6th floor to 9th floor Tk. 6.92
30.12.4 Add for each addl floor for 10th floor and above Tk. 8.07
30.13 Minimum 10 mm thick cement plaster in cement: sand (1:5) in outet surface of
external wall with specified external plaster mix applied in two coats (first coat 617
mm and second coat 4/3 rnm) finishing the corner and edge including washing of
sand cleaning the surface, scaffolding and curing for min 3 (three) days on mortar
joints by jute/brusr :., wet, followed by impervious/wet covering for another 4 (four)
days etc. all complete etc. all complete and accepted by the Engineer. (Rate is
excluding c.ost of grouting and reinforcement)
30.13.2 Add for each addl. floor up to 5th floor Tk. 11.03
30.13.3 Add for each addI floor for 6th floor to 9th floor Tk. 16.55
30.13.4 Add for each addl floor for 10th floor and above Tk. 22.07
PWD SoR 21)14 for Civil Works 197
30.14.1 Supplying and placing of approx. 60 mm thick grey Uni-Block paving for walk way Tk. 799.00 _I
having compressive strength of 15 N/mm2 on compacted sand bed of 50 mm on )
stabilized soil base, and filling all interstices with sand, cleaning etc. accepted by the
Engineer.
30.14.2 Supplying and placing of approx. 60 mm thick coloured Uni-Block for paving walk Tk. 1,019.00
way having compressive strength of 15 N/mm2 on compacted sand bed of 50 mm on
stabilized soil base, and filling all interstices with sand, cleaning etc. accepted by the
Engineer.
30.15.1 Supplying and placing of 60 mm thick grey Uni·Block for paving foot-path, major Tk. 1,081.00
walk way, car porch having compressive strength of 49 N/mm2 on compacted sand
bed of 50 mm on stabilized soil base, and filling all interstices with sand, cleaning
etc. accepted by the Engineer.
30.15.2 Supplying and placing of 60 mm thick coloured Uni·Block for paving foot·path, Tk. 1,155.00
major walk way, car porch having compressive strength of 49 N/mm2 on
compacted sand bed of 50 mm on stabilized soil base, and filling all interstices with
sand, cleaning etc. accepted by the Engineer.
30.16.1 Supplying and placing of 80 mm grey Uni·Block for paving Heavy Trafic areas, Tk. 1,330.00
Roads Rounds Abuts, Industrial Yards etc having compressive strength of 49
N/mm2 on compacted sand bed of 50 mrn on 'stabilized soil base, and filling ·all
interstices with sand, cleaning etc. accepted by the Engineer.
30.16.2 Supplying and placing of 80 mm thick coloured Un i-Block for paving Heavy'trafic Tk. 1,590.00
areas, road, industrial yard etc having compressive strength of 49 Nlmm2 on
compacted sand bed of 50 mm on stabilized soil base, and filling all interstices with
sand, cleaning etc. accepted by the Engineer.
30.17.1 'Supplying and placing of grey 200 x 100 x 60 mm Rectangular Block having Tk. 1,399.00
compressive strength of 15N/mm2 on 50 mm thick compacted sand bed, and filling
all interstices with sandt cleaning etc. accepted by the Engineer.
30.17.2 Supplying and placing of coloured 200 x 100 x 60 mm Rectangular Block having Tk. 1,605.00
compressive strength of 15N/mm2 on 50 mm thick compacted sand bed, and filling
all interstices with sand, cleaning etc. accepted by the Engineer.
30.18.1 Supplying and placing' of grey engraved cement concrete tiles (250 x 250 mm) in .
size having minimum thickness 24 mm over 12 mm sand cement mortar (4:1) each
at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4)
including raking out joints and cutting the tiles to required sizes wherever necessary
with high class recessed pointing, cleaning and washing of sand, curing for min 3
(three) days on mortar joints by jute Ibru~h in wet, followed by impervious Iwet
covering for another 4 (four) days etc. all complete and accepted by the Engineer.
30.18.1.2 Add for eacn add!, floor up to 5th floor Tk. 31.28
30.18.1.3 Add for each addl floor for 6th floor to 9th floor Tk~ 39.10
30.18.1.4 Add for each addl floor for 10th floor and above Tk. 46.92
PWD SoR 2014 for Civil Works 198
30.18.2 Supplying and placing of coloured engraved cement concrete tiles (250 x 250 ::;:'·,':·,C·'·.;X:':.:::':'f:;":,\
mm) in size having minimum thickness 24 mm over 12 mm sand cement mortar (4:1)
each at a distance of 6 mm apart and filling the joints with cement sand mortar (1:4) .
including raking out joints and cutting the tiles to required sizes wherever necessary
with high class recessed pointing, cleaning and washing of sand, curing for min 3
(three) days on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another 4 (four) days etc. all complete and accepted by the Engineer.
30.18.2.2 .Add for each add!. floor up to 5th floor Tk. 31.28
30.18.2.3 .Add for each addl floor for 6th floor to 9th floor Tk. 39.10
30.18.2.4 Add for each addl floor for 10th floor and above Tk. 46.92
30.19.1 215 mm thick wall (excluding plaster thickness) with 215 x 100 x 65 mm concrete
solid block having minimum compressive strength of 21 N/mm2 of size with 6 mm
thick cement sand mortar in 1:6 in superstructure including racking out the joints,
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min. 3 (three) days on mortar jOint by jute! brush
in wet followed by impervious covering for another 4 (four) days etc. all complete and
accepted by the Engineer. .
30.19.1.2 Add for each addI. floor up to 5th floor Tk. 31.28
".
30.19.1.3 Add for each addI floor for 6th floor to 9th floor Tk. ". ;.~39:10
30.19.1.4 Add for each addl floor for 10th floor and above Tk. 46.92
30.19.2 100 mm thick wall (excluding plaster thickness) with 215 x 100x 65 mm concrete
solid block having minimum compressive strength of 21 N/mm20f size with 6 mm
thick cement sand mortar in 1:6 in superstructure including racking out the joints,
filling the interstices with mortar and making bond with connecting walls including
necessary scaffolding and curing for min. 3 (three) days on mortar joint by jutel brush
in wet followed by impervious covering for another 4 (four) days etc. all complete and
accepted by the Engineer.
30.19.2.2 Add for each addl. floor up to 5th floor Tk. 31.28
30.19.2.3 Add for each addl floorfor 6th floor to 9th floor Tk. 39.10
30.19.2.4 Add for each addl floor for 10th floor and above Tk. 46.92
30.20.1 38 mm thick Grey cladding work in facing on superstructure with (200 x 90x 38)
mm size concrete clad pested with 20 mm thick cement mortar (1 :4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
deaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by' jute Ibrush in wet, followed by impervious Iwet covering for
another 4 (four) days etc. all complete for up to 4th floor ac':epted by the Engineer.
PWD SoR 2014 for Civil Works 199
30.20.1.2 Add for each addl. floor up to 5th floor Tk. 31.28 I
30.20.1.3 Add for each addl floor for 6th floor to 9th floor Tk. 39.10
30.20.1.4 Add for each addl floor for 10th floor and above . Tk. .46.92
30.20.2 38 mm thick coloured cladding work in facing on superstructure with (200 X92 x .
38) mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be placed'
at 6 mm apart, fillir:lg the interstices with same mortar, raking out joints and cutting
the clad to reql,lire~ sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar joints by jute !brush in wet, followed by impervious Iwet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.2.2 . Add for each addl. floor upto 5th floor Tk . 31.28
30.20.2.3 Add for each addl floor for 6th floor to 9th floor Tk. 39.10
30.20.2.4 Add for each addl floor for 10th floor and above. Tk. 46.92
30.20.3 50 mm thick Grey cladding work in facing on superstructure with (400 x100 x 50)
mm size concrete clad pestedwith 20 mm thick cement mortar (1:4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar jOints by jute /brush in wet, followed by impervious Iwet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.3.2 Add for each add!. floor up to 5th floor Tk. 31.28
30.20.3.3 Add for each addl floor for 6th floor to 9th floor Tk. 39.10
30.20.3.4 Add for each addl floor for 10th floor and above Tk. 46.92
30.20.4 50 mm thick coloured cladding work in facing on superstructure with (400 x 100
X 50) mm siz~ concrete clad pested with 20 mm thick cement mortar (1 :4) to be
placed at 6 mm apart, filling the interstices with same mortar, raking out joints and .
cutting the; clad to required sizes wherever necessary with high class recessed
pointing, cleaning and washing of sand, necessary scaffolding; curing for min 3
\...ree) days on mortar joints by jute Ibrush in wet, followed by impervious Iwet
covering for another 4 (four) days etc. all complete for up to 4th floor accepted by the
Engineer.
30.20.4.2 Add for each ac11 floor up to 5th floor Tk. 31.28
30.20.4.3 Add for each addl floor for 6th floorto 9th floor Tk. 39.10
&n/
PWD SoR 2014 for Civil Works 200
30.20.4.4 Add for each addl floor for 10th floor and above Tk. 46.92
30.20.5 15 mm thick Grey cladding work in facing on superstructure with (420 x 330 x 15)
mm size concrete clad pested with 20 mm thick cement mortar (1 :4) to be placed at
6 mm apart, filling the interstices with same mortar, raking out joints and cutting the
clad to required sizes wherever necessary with high class recessed pointing,
cleaning and washing of sand, necessary scaffolding, curing for min 3 (three) days
on mortar jOints by jute Ibrush in wet, followed by impervious Iwet covering for
another 4 (four) days etc. all complete for up to 4th floor accepted by the Engineer.
30.20.5.2 Add for each add!. floor up to 5th floor Tk. 31.28
30.20.5.3 Add foreach addl floor for 6th floor to 9th floor Tk. 39.10
30.20.5.4 Add for each add I floor for 10tll flo'or and above Tk. 46.92
30.20.6 15 mm thick coloured cladding work in facing on superstructure with (420 x 330 x
15) mm size concrete clad pested with 20 mm thick cement mortar (1:4) to be
placed at 6 mm apart, filling the interstices with same mortar; raking out joints and
cutting the clad to required sizes wherever necessary with high class recessed
pointing, cleaning and washing of sand, necessary scaffolding, curing for min 3
(three) days on mortar joints by jute !brush in wet, followed by impervious Iwet
covering for another 4 (four) days etc. all complete for up to4th floor accepted by the
Engineer.
30.20.6.2 Add for each add!, floor up to 5th floor Tk. 31.28
30.20.6.3 Add for each addl floor for 6th floor to 9th floor Tk. 39.10
30.20.6.4 Add for each addl floor for 10th floor and above Tk. 46.92
30.21.1 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of red colour Tk. 68.00
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
30.21.2 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of oriental colour Tk. 63.00
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
30.21.3 Supplying, carrying, placing, providing (418 ·x 330 x 17) mm size of antique red
....11\. 68.00
colour concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile
to the roof members of truss accepted by the Engineer.
30.21.4 Supplying, carrying, placing, providing (418 x 330 x 17) mm size of green colour Tk. 73.00
concrete roof tiles on pre-fixed and pre-fabricated truss and fixing each tile to the
roof members of truss accepted by the Engineer.
30.22 Supplying, carrying, placing, providing of concrete Kerb stone size (600 x 300 x Tk. 195.00
100) mm approved and accepted by the Engineer.
~ ~/
PWD SoR 2014 for Civil Works 201
31.2 Field visit, fixing location of bore holes citing respective coordinates in X, Y & Tk. 5,697.00
Z axes with respect to pre-determind datum(BM} and inspection of sampling and.
samples by the Geo-tech. Expert I Engineer
31.3.1 Installation of boring equipment at- site on dry ground/and a surface up to a Tk. 839.00
maximum 750 mm under water and accepted by the Engineer..
31.3.2 Installation of boring equipment at site: for depth of water above 750 mm to 1500 Tk. 4,223.00
mm and accepted by the Engineer.
31.3.3 Installation of boring equipment at site: For depth of water above 1500 mm Tk. 5,715.00
(stagnant water) and accepted by the Engineer.
31.4 Boring 100 mm dia bore-hole by wash boring method:
31.4.1 Boring 100 mm dia bore-hole by wash boring method: 0 to 15 meter including the Tk. 214.00
depths for SPT operation and accepted by the Engineer.
31.4.2 Boring 100 mm dia bore-hole by wash boring method: 15 meter to 25 meter Tk. 235.00
including the depths for SPT operation and accepted by the Engineer.
31.4.3 Boring 100 mm dia bore-hole by wash boring method: 25meterto 35 meter including Tk. 241.00
the depths for SPT operation and as and accepted by the Engineer.
31.4.4 Boring 100 mm dia bore-hole by wash boring method: 35 meter to 45 meter Tk. ~46.00
including the depths for SPT operation and accepted by the Engineer.
31.4.5 Boring 100 mm dia bore-hole by wash boring method: 45 meter &above including Tk. 256.00
the depths for SPT operation and accepted by the Engineer.
31.5 . Execution of SPT with Standard Autometic Hammer (ASTM 0-1586-84, hammer:
(140 + 2 Ibs) /(63.5 + 1 Kg), height of fall: (30" + 1") / (760 mm + 25 mm) including
withdrawn of drilling pipe from the bore-hole and fixing the steel cap with drilling pipe
and replacing the drilling pipe with cap into the bore hole up to the layer of interest .
approved and accepted by the Engineer.
31.5.1 SPT @ 1500 mm interval:. For 0 to 15 meter Tk. 90.00
~ )~
PWD SoR 2014 for Civil Works 202
Carrying out different test on soil samples collected from the sub-soil·
investigation site accepted by the Engineer.
31.10 Specific gravity Tk. 150.00
31.11 Grain size Analysis of soil by Sieve and Hydrometer analysis & Specific gravity test, Tk. 1,050.00
And Providing ASTM Classification of Soil
--- _.-
-~ ~.-
31.12 Visual Inspection &Classification of soil for engineering purposes Tk. . 1:13.00
~ ~
PWD SoR 2014 for Civil Works 203
31.25.2.4 Unconsolidated undrained triaxial test without pore pressure Tk. 1,200.00
31.25.3 Field Vanshear test in cohesive soil (ASTM 0-2573-72, 1978) Tk. 2,100.00
31.27 Field density test in/c field visit for non-cohesive soil Tk. 2,250.00
31.29 One dimensional swelling I settlement potential of cohesive soil. Tk. 2,250.00
31.30 Non-repetitive static plate load test of soil (ASTM 0-1196-64, reapproved in 1977 Tk. 2,100.00
. 31.32 Sub - Soil investigation by exploratory borings andl or by CPT, DCP etc. collecting ,
and necessary testing of samples in numbers as required for Stratification of Layers,
physical parameters of soils like Atterberg limits,Specific Gravity, Gain size
distribution(by wet seive, Hydrometer if required) ,shrinkage & swelling, Settlement;
C -4> values and other Strength parameters to ascertain Bearing Capacity , Skin
friction, End bearings etc at layers of interest as per respective National/International
standards and entering all theese data & information in necessary Tables &Graphs,
furnishing them in the form of Standard Sub-Soil Investigation Report duly signed by
competent Engineer & Exploratory Office.
----_. ------ 31.33 Extra cost per site for Mobilization & demobilization in addition to any item,
under 31.32
31.33.2 Other than divisional city: cost in addition to item 31.33.1 for the distance from Tk. 20.00
respective divisional HQ to site.
31.34 Extra cost per bore hole, if the same is under water by more than 1.5m in depth Tk . 4,223.00
J './" ./
,( i/, /
A0/~(£l/
PWD SoR 2014 for Civil Works 205
a) The following table is provided as one of many quality controlling factors with the objective of estimating cost of material tests and to ensure quality leading to durable and safe structure. Sampling of
construction materials and products considered to be tested shall be done under the direct control and guidance of Procuring Entity. Representatlve(s) of the contractor shall be liable to collect or
prepare sample etc., send to the testing laboratories in an acceptable manner and collect authenticate copy 1 copies of test results I reports and duly submitted to the office of the Procuring Entity.
Procuring Entity shall· recommend the contractor to prepare bill for payment. It is to be noted that materials and products to be tested and its frequencies described here are merely as minimum ar:ld
Procuring Entity may consider for more tests from Table A of this division
b) Tests are to be done in the nearest laboratory as far as possible.
c) Procuring Entity may include any other material or tests in their estimate with intimation to Convener. Schedule of Rates Committee. PWD.
d) laboratory testing service provider:
1. HBRI: Housing and Building Research Institute. 120/3 Darus-Salam. Mirpur. Dhaka. Phone: +8802-8060989.
2. BUET (BRTC) : Bangladesh University of Engineering & Technology. Dhaka-1000. (Bureau of Research, Testing & Consultation) Phone: +8802"9665q50-56. Ext: 7226.
3. KUET (CRTS) : Khulna University of Engineering & Technology. Khulna-9203. (Centre for Research Testing & Services). Phone: +88041-77480, Ext: 200.
4. RUET (DCE) : Rajshahi University of Engineering & Technology. (Department of Civil Engineering). Phone: +880721-750742-3.
5. SUST (CRTC): Shahjalal University of Science &Technology. Sylhet-3114. (Centre for Research Testing &Consultancy). Phone: +880821-713491, Ext: 423.
6. CUET (BRTC) : Chittagong University of Engineering & Technology. Chittagong-4349. (Bureau'of Research. Testing & Consultation). Phone: +880031-714948.
7. DUET (DCE) : Dhaka University of Engineering & Technology. Gazipur-1700. (Department of Civil Engineering). Phone: +88-02-9204703
32.0 I Conducting laboratory test of engineering materials during construction in progressive manner well fitted with physical progress of work, by the procuring entity. with all logistic support
supposed to be given by the contractor; where sampling, sample sending to laboratory and collecting test results from the samples to laboratory shall be under strict control and guidance of
procuring entity following the norms elucidated in respective material standards like BOS. EN. ASTM. ISO. IS etc. and paid to the contractor after complete and proper documentation on:
1) laboratory test results in original
2) evidence of receiving samples in the laboratory in correct order
3) forwarding letter of procuring entity addressed to laboratory for testing
4) evidence of receiving "forwarding letter" with recipients' full address and contact number
5) conformation on samples tested that sent in sealed condition bearing the signature and date of procuring entity
8) ensurance docu~ents of sealing, signing and sending the samples.
@. ~
PWD SoR 2014 for Civil Works 206
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
Item No. Lab Test Items Remarks BUET KUET RUET CUET DUET
Slab. Beam, Others SUST
Foundation Column HBRI (BRTC
Wafll Brick Wall (BRTC) (CRTS) (DC E) (CRTC) -(DCE)
) -
1 2 3 4 5 6 7 8 9 10 11 12 13 14
32.1 CONCRETE
Average
Compressive
Strength, fcr
Compressive 7 days strength: 7 days strength: 7 days strength: - 2091.01 1568.25 3659.26 - 1960.3
strength: 1 set.of 3 1 setof3 1 setof3
Concrete cylinders samples per samples per samples per floor
N 100x 200 mm
C"") Building Unit. - Building Unit. per Building Unit.
1. Anyone of I
N
C"")
Compressive 28 days 28 days strength: 28 days strength: 100mmx - 2091.01 1568.25 3659.26 - 1960.3
C'I
strength: strength: 1 setof3 1 setof3 200mm and
..- Concrete cylinders 1 setof3 samples per samples per 150mmx300
N 100x 200 mm samples per 3000 sft or less 1500 sft or less Cylinder may be
C"")
1500 sft or less of PLA per floor. of PLA per floor. tested.
ofPLA.
2. in case of . '
Compressive 7 days strength: 7 days strength: 7 days stren~th: brand change. - 3789.95 2352.38 16989.4 - 3659.3
..- strength: 1 set of 3 1setof3 1 setof3 non compliance
c--! Concrete cylinders samples per samples per samples per floor of test results
N 150x 300 mm Building Unit. Building Unit. per Building Unit
C"") etc. contractor
N will be liable for
additional tests .
N
("I')
Compressive 28 days 28 days strength: 28 days strength:
and costs.
3789.95 2352.38 16989.4 - 3659.3
N strength: strength: 1 set of 3 1 set of 3
~ Concrete cylinders 1 set of 3 samples per samples per
N 150x 300 mm samples per 3000 sft or less 1500 sft or less
("I')
1500 sft or less of PLA per floor. of PLAper floor.
ofPLA.
32.1.3 -In - situ Core cutting - 1 set of 3 1 setof3 More tests might - 6665.08 . - - -
& testing without samples per samples per be needed as
Scanning ,excluding Building Unit. Building Unit. and when
field visit ** • deemed by the
Design Office.
---- -~--
L----_ ~- ~--
-----
~ ~
PWD SoR 2014 for Civil Works 207
Str~ctural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
CUET
I
Item No. Lab Test Items Slab, Beam, Remarks BUET KUET RUET SUST DUET
Foundation Column Others HBRI (CRTC) (BRTC
Walll Brick Wall (BRTC) (CRTS) {DC E) (DeE)
)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
32.1.4 In-situ Core cutting - - - This test is not a - 13068.8 - - - -
&testing with general
Scanning, excluding requirement,
field visit "* however needs
to be carried out
as and when
deemed by the I
Design Office. j
32.1.5 Slump Te~~ at field Randomly once Randomly once Randomly once
per 500 sft of per 500 sft of per 500 sft of
PLA. PLA. PLA.
32.2 CEMENT
32.2.1 Compressive Once for getting Once for getting Once for getting in case of brand 2352.38 9409.52 2875.13 8625.4 5881 8625.4 .
Strength approval of approval of approval of change,non
(3 and 28 days) cement type & cement type & cement type & compliance of
brand, per 5000 brand, per 5000 brand, per 5000 test results etc ..
sft or less of sft or less of PLA sftor less of PLA contractor wHi be
PLA. per floor. per floor. liable for
additional tests
and costs.
32.2.2 Setting time: Initial Once for getting Once for getting Once for getting in case of brand 1306.88 3528.57 2483.07 3267.2 - -
&Final approval of approval of approval of change, non
cement type & cement type & cement type & compliance of
brand, per 5000 brand, per 5000 brand, per 5000 test results etc.
sft or less of sft or less of FILA sft or less of PLA contractor will be
PLA. per floor. per floor. liable for
i additional tests
i and costs.
(!{ ~
-.I.
PWD SoR 2014 for Civil Works 208
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
Item No. Lab Test Items Remarks CUET
Slab, Beam, BUET KUET RUET SUST DUET
Foundation Column Others HBRI (BRTC
Wall' Brick Wall (BRTC) (CRTS) (DCE) (CRTC) (DCE)
)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
32.2.3 Fineness Once per brand. Once per brand. Once per brand. in case of brand 1306.88 2875.13 1698.94 2613.76 1045.5 2613.8
change,non
compliance of
test results etc.
contractor will be
liable for
additional tests
and costs.
32.2.4 Soundness Once per brand. Once per brand. Once per brand. in case of brand
change,non
compliance of
consult
lab
- . - - -
~
I
test results etc.
I
contractor will be I
liable for !
I
additional tests I
and costs.
-- _ .. __.,
I
32.2.5 Compositicm Once per brand. Once per brand. Once per brand. in case of brand consult - - - - I
~ ... ~
PWD SoR 2014 for Civil Works 209
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
@. ~
PWD SoR 2014 for Civil Works 210
-
Structural Components &Testing Frequency UNIT RATES PER SET OF TEST in BOT
32.4.2 Unit Weight 1 set of 3 1setof3 1 set of 3 in case of non 653.44 2875.13 2091.01 2613.76 - 2613.8
samples 11500 samples/2500 5ft samples 13000 compliance of
sft or less of or less of PLA. sft or less of test results etc.
I
32.4.5 : Salt content or 1 setof3 15etof3 1 setOf3 in case of non - - 2091.01 2613.76 1568.3 2221.7
Sulphate content samples 11500 samples/2500 sft samples 13000 compliance of
sft or less of or less of PLA. sft or less of test results etc.
PLA. Minimum ~ Minimum 1 set. PLA. Minimum 1 contractor will be
set set. liable for
: additional tests
and costs.
--~-------
~ ~
PWD SoR 2014 for Civil Works 211
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST In BOT
32.4.7 LOS 1 set 3 times per 1 set 3 times per 1 set 3 times per in case of non 1568.25 - 3789.95 4704.76 2613.8 4835.5
ANGELES 3000 sft. 3000 sft. 3000 sft. compliance of
ABRASION (applicable to (applicable to (applicable to test results etc.
TEST road wOrk). road work). road worK}. contractor will be
liable for
additional tests
and costs.
32.5.1 Sieve Analysis 1 setof3 1 set of 3 1 setof3 in case of non 1045.5 2091.01 1568.25 1960.32 - 1960.3 I
samples 11500 samples/2500 sft samples 13000 compliance of
sft or less of or Jess of PLA. sft or less of test results etc.
PLA. Minimum 1 Minimum 1 set. PLA. Minimum 1 contractor will be
set. set.. liable for
additional tests
and costs. I
~ ~
,.
-"~
PWD SoR 2014 for Civil Works 212
Structural Components &Testing Frequency UNIT RATES PER SET OF TEST in BOT
, and costs.
32.5.4 Bulking of Sand Once per Once per floor of Once per floor of in case of non - 5619.58 3920.63 4704.76 - 4574.1
Eluilding Unit Building Unit. Building Unit. compliance 'of,
test results etc.
"
contractor will be
liable'for
additional tests,
and costs.
32.5.5 ' Salt content or Once per Once per floor of Once per floor of in case of non - - 2091.01 2613.76 1568.3 2221.7
Sulphate content Building Unit Building Unit. Building Unit. compliance of
test results etc.
I contractor will be
liable for
additional tests
i
I and costs.
32.5.6 I Mica content - - Only demanded - 9801.59 4182.01 5227.51 - 4574.1
by design office
or, felt by PE on
visit site sample
Isource.
----
~ .~
PWD SoR 2014 for Civil Works 213
_. ~
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT I
~ ~
PWD SoR 2014 for Civil Works 214
.Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
I .
~ ~.
PWD SoR 2014 for Civil Works 215
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
1 2 3 4 5 6 7 8 9 10 11 12 13 14
32.7.1 Absoprtion - - 1 set of 3 in case of brand - 2091.01 1698.94 1960.32 - 1960.3
samples/3000 sft change, non
or less of PLA. compliance of
Minimum 1 set. test results etc.
contractor will be
liable for
additional tests
and costs.
32.7.2 Un.it Weight - - 1 set of 3 in case of brand - 2875.13 2352.38 2875.13 - 2613.8
samples/3000 sft change, non
or less of PLA. compliance of
Minimum 1 set. test results etc. I
contractor will be
liable for
additional tests
I
I
and costs. I
~ ~
PWD SoR 2014 for Civil Works 216
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
@. )&w/
PWO SoR 2014 for Civil Works 217
. Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
~ JWw/
PWD SoR 2014 for Civil Works 218
------~-~
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
(!{ ~
PWO SoR 2014 for Civil Works 219
I
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
-1_
32.11 uPVC PIPE
32.11.1 1/2"·4"
32.11.1.1 - - - As and when - - - - -
Pressure Test required by the 3,920.63
PE
32.11.1.2 - - - As and when - - - - - -
Dimension Test required by the 1,960.32
PE
32.11.1.3 - - - As and when - - - - - -
Aceton Test required by the 980.16
PE
32.11.1.4 - - - As and when - - - - - -
Impact Test required by the 1,960.32
PE --- -----'--~.~~ ~.
~ ~
PWD SoR 2014 for Civil Works 220
-----_.
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
PE i
~,92~:63
32.11.1.7 - - As and when - - - -
Filter Test required by the
-_ _ _._-__ _:
PE
32.11.2 5"·6"
···_·T-·--··--r-··_·_·_·-i
32.11.2.1 - . As and when - - - - - I - r. -.- ~
---l--~-t~~~
Pressure Test required by the
PE
32.11.2.2 - - - As and· when -
Dimension Test required by the
PE
i 1.960.32
I ----
32.11.2.3 - - As and when - - - - ..
Aceton Test required by the 980.16
PE ..
32.11.2.4 - As and when - - - - - -.
Impact Test required by the 1,960.32
PE
32.11.2.5
Heat Reversion
- - - As and when - - - - - -
required by the 980.16
Test PE
32.11.2.6 - - - As and when - - ~
- - -
Tensile Test required by the 980,16 '
PI,;
-. _....
@: --~-
PWD SoR 2014 for Civil Works 221
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
@: ~
PWD SoR 2014 for Civil Works 222
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
32.11.5 12"
32.11.5.1 - - - As and when - - -
Pressure Test required by the 9,148.15
PE
~ ~
PWD SoR 2014 for Civil Works 223·
Structural Components & Testing Frequency UNIT RATES PER SET OF TEST in BOT
@: ~
.:
Structural Components &Testing Frequency UNIT RATES PER SET OF TEST in BOT
Note: Follow Division 32 B : LASORATORY CHARGE FOR TESTING OF MATERIALS or consult laboratory for the Rates of test items not found here.
~ ~.
PWD SoR 2014 for Civil Works 225
1 2 3 4 5 6 7 8 9 10
AGGREGATES
1 Absorption and Specific Gravity 1 Tk. 1.306.88 Tk. 4,051.32 Tk. 3,397.88 Tk. 3,920.63 Tk. - Tk. 3,659.26 -
2 Aggregate crushing value (ACV) 1 Tk. 1,960.32 Tk. 4,182.01 Tk. 3,397.88 Tk. 3,920.63 Tk. 2,613.76 Tk. 3,920.63 -
3 Aggregate impact value (AIV) 1 Tk. - Tk. 3.528.57 Tk. 3,136.51 Tk. 3.920.63 Tk. 2,613.76 Tk .. 3,267.20 - 1
---j
4 Angularity Number in/c sp. gr. 1 Tk. - Tk. 4,182.01 Tk. 3,397.88 Tk. 4,312.70 Tk. - Tk. 3,920.63
5 Bulking of ~ :'nd 1 Tk. - Tk. 5,619.58 Tk. 3,920.63 Tk. 4,704.76 Tk. - Tk. 4,574.07 -
6 CBR of base and sub-base material 1 Tk. - Tk.37,768.78 Tk. 31.887.83 Tk. 39,206.35 Tk. - Tk. 34,632.28 -
7 Clay lump and friable particles 1 Tk. 1,306.88 Tk. 3,267.20 Tk. 2,744.44 Tk. 3,267.20 Tk. - Tk. 3,005.82 -
8 Coal and lignite 1 Tk. - Tk. 3,267.20 Tk. 2.613.76 Tk. 3,267.20 Tk. - Tk. 2,875.13 -
3,267.20 Tk.
I
9 Elongation Index (EI) 1 Tk. 1,306.88 Tk. 3,528.57 Tk. 2,744.44 Tk. - Tk. 3,267.20 -
10 Flakiness Index (FI) 1 Tk. 1,306.88 Tk. 4,182.01 Tk. 3,397.88 Tk. 4,312.70 Tk. - Tk. 3,920.63 -
11 l.A. Abrasion (ASTM C535 or ASTM C131) 1 Tk. 1,568.25 Tk. - Tk. 3,789.95 Tk. 4,704.76 Tk. 2,613.76 Tk. 4,835.45 -
12 Mica content 1 Tk. - Tk. 9,801.59 Tk. 4,182.01 Tk. 5,227.51 Tk. - Tk. 4,574.07
. 13 Organic Impurities 1 Tk. 1,960.32 Tk. 2,483.07 Tk. 3,267.20 Tk. 3.920.63 Tk. 1,568.25 Tk . 2,221.69 -
14 Effect of organic impurities 1 Tk. - Tk. 13,591.53 Tk. 11,369.84 Tk. 14,375.66 Tk. - Tk. 11,761.90 -
15 Standard Proctor test of aggregate (MOD) 1 Tk. - Tk. 14,767.72 Tk. 12,807.41 ' Tk. 15.682.54 Tk. - Tk. 13,722.22 -
16 Modified Proctor or Vibrating 1 Tk. - Tk. 22,608.99 Tk. 19,080.42 Tk.' 23,523.81 Tk. .; Tk. 20.910.05 -
17 Salt content or Sulphate content 1 Tk. - Tk. 0
Tk. 2,091.01 Tk. 2,613.76 Tk. 1,568.25 Tk. 2,221.69 .
18 Sieve analysis (CA) 1 Tk. 1,045.50 Tk. 3,528.57 Tk. 2,875.13 Tk. 3.528.57 Tk. 1,306.88 Tk. 3,136.51 -
----- --------- -------
~ ~
PWO SoR 2014 for Civil Works 226
..
SL.No. Materials and Name of Tests Sample RATE
Size DCE, DUET
HBRI BRTC, BUET CRTS, KUET DCE,RUET CRTC, SUST BRTC, CUET
1 2 3 4 5 6 7 8 9 10
19 Sieve analysis (Ballast) 1 Tk. - Tk. 4,182.01 Tk. 3,397.88 Tk. 4,312.70 Tk. - Tk. - -
20 Sieve analysis (FA) 1 Tk. 1,045.50 Tk. 2,091.01 Tk. 1,568.25 Tk. 1,960.32 Tk. - Tk. o 1,960.32 -
21 Wash sieve analysis 1 Tk. - Tk. 2,875.13 Tk. 1,960.32 Tk. 2,352.38 Tk. - Tk. 2,613.76
24 Soundness with Na2S04 1 Tk. 7,841.27 Tk. 12,676.72 Tk. 10,455.03 Tk. 13,722.22 Tk. - Tk. 11,108.47 -
23 Soundness with Mg2S04 1 Tk. 7,841.27 Tk.16,074.60 Tk. 13,068.78 Tk. 15,682.54 Tk. - Tk. 13,068.78
24 Ten percent fines (10% fines) 1 Tk. 3,920.63 Tk. 7,057.14 Tk. 5,227.51 Tk. 6,273.02 Tk. 2,613.76 Tk. 6,534.39 -
25 Unit weight of aggregate (CA) 1 Tk. 653.44 Tk. 2,875.13 Tk. 2,091.01 Tk. 2,613.76 Tk. - Tk. 2,613.76
......
26 Unit weight of aggregate (FA) 1 Tk. 653.44 Tk. 2,091.01 Tk. 1,829.63 Tk. 2,221.69 Tk. - Tk. 1,960.32 -
---
27 Void ratio I Porosity 1 Tk. 653.44 Tk. 4,835.45 Tk. - Tk. 3,~20.63 Tk. 1,568.25 Tk. 3,789.95 -
CEMENT CONCRETE
28 compressive strength:
3
Tk. - Tk. 2,091.01 Tk. 1,568.25 Tk. 3,659.26 Tk. - Tk. 1,960.32
Concrete cylinders (100 x 200 mm)
29 Compressive strength:
3
Tk. - Tk. 3,789.95 Tk. 2,352.38 Tk. 16,989.42 Tk. - Tk. 3,659.26 -
Concrete cylinders (150 x 300 mm)
30 Concrete Spun 3 Tk. - Tk. 3,267.20 Tk. 2,613.76 Tk. - Tk. - Tk. - -
31 Concrete cylinders casting & testing 3 Tk. 784.13 Tk. 19,080.42 Tk. 7,187.83 Tk. - Tk. Tk. 16,989.42 -
32 Concrete beam in flexure 3 Tk. 3,920.63 Tk. 8,233.33 Tk. 6,534.39 Tk. 6,534.39 Tk. 3,920.63 . Tk. 7,187.83 -
33 Concrete slab in flexure 3 Tk. - Tk. 11,369.84 Tk. 9,148.15 Tk. - Tk. - Tk. - -
~ ~
PWO SoR 2014 for Civil Works 231
-.--.---,.- -_. '--.--_._ .... _----
SL.No. Materials and Name of Tests Sample RATE
Size
-
HaRt BRTC, BUET CRTS, KUET DCE,RUET CRTC, SUST BRTC,'CUET DCE, DUET
1 2 9
------
10
3 4 5 6 1 8
----.-~
102 Tension (deformed bar::> 25 mm) 3 Tk. - Tk. 3,659.26 Tk. 3,397.88 Tk. 3,267.20 Tk. - Tk.
.--. -- -- ---- - ---------~
103 Tension (plain bar> 25 mm) 3 Tk. Tk. - Tk. 3,397.88 Tk. 3,136.51 Tk. Tk.
----
104 Bend test (up to 25 mm)
. - 3 Tk. - Tk. 1,176.19 Tk. 914.81 Tk. 1,306_88 Tk. - Tk. 1,045.50 -
-------
105 Re-bend test (up to 25 mm) 3 Jk. Tk. 1,437.57 Tk. 1,176.19 Tk. 1,306.88 Tk. - Tk. 2,J52.38 -
106 Bend test (above 25 mm) 3 Tk. - Tk_ 1,306.88 Tk. 1,045.50 Tk. 1,568.25 Tk .. - Tk. 1,176.19 -
------
107 Re-bend test (above 25 mm) 3 . Tk. - Tk. 1,568.25 Tk. 1,306.88 Tk. 1,568.25 Tk. - Tk. 2,613.76 -
... --_._---
108 Shear test 3 Tk. - Tk. - Tk. 1,960.32 Tk. 3,267.20 Tk. Tk. 3,528.57 -
111
Impact
3
Tk.
Tk.
-
1,960.32
Tk. 3,659.26
Tk. 8,494.71
Tk.
Tk.
3,136.51
7,187.83
Tk.
Tk.
2,352.38
9,148.15
Tk.
Tk. 4,574.07
-
.+------------ ---:....------
Tk.
Tk.
3,659.26
7'8~
-
-
112 Deformation measurement 3 Tk. - Tk. 3,267.20 Tk. 1,698.94 Tk. 2,352.38 Tk. - Tk. 1,960.32 .-
. - ----_.
113 Spring test 1 Tk. Tk. 3,136.51 Tk. 2,613.76 Tk. 3,136.51 Tk. - Tk. 2.875.13. -
--- ------
114 Tension (eye-hooks, anc~or bolt) 1 Tk. Tk. 5.096.83 Tk. 4,443.39 Tk. Tk. o Tk. 4,'104.76 -
115 Weight 3 Tk. 261.38 Tk. - Tk. - Tk. 980.16 Tk. 914.81 Tk_ 914.81 -
116 H.T. Wire 3 Tk. Tk. 7,841.27 Tk. 3,920.63 Tk. 4,704.76 Tk. - Tk. -
117 Strand 3 Tk. - Tk. 14.114.29 Tk. 11.108.47 Tk.11,108 ..47 Tk. - Tk. - -
120 Absorp'tion 5 Tk. - Tk: 2,091.01 Tk. 1,829.63 Tk. - Tk. - Tk. -
121 Flexural 5 Tk. 0
Tk. 2,875.13 Tk. 2,352.38 Tk. 0
Tk. 0
Tk. - - --
(!£ ~
-~,'-
- "
-"'""\
PWD SoR 2014 for Civil Works 232
-
SL.No. Materials and Name of Tests Sample RATE
Size
HBRI BRTC, BUET CRTS, KUET DCE, RUET CRTC, SUST BRTC, CUET DCE,DUET
1 2 3 4 5 6 7 8 9 10
122 Wrape & Tk. - Tk. Tk. 1,698.94 Tk. Tk. Tk. -
SOIL
123 CBR of soils (three points) 1 Tk. - Tk. - Tk. 15,682.54 Tk. 20,910.05 Tk. 10,455.03 Tk. 20,910.05 -
124 Field Tk. - Tk. - Tk. 25.484.13 Tk. 7,841.27 Tk. 6,534.39 Tk. 7,841.27 -
density(8spot+ 2proctor+ 2seives/Hydrometer 1
exluding field visit *
--
-
j
125 Sp. gr. 1 Tk. Tk. 2,221.69 Tk·. 1,960.32 Tk. 2,352.38 . Tk. 1,568.25 Tk. 2,091.01
~ 126 Hydrometer, sieve analysis & sp. gr 1 Tk. - Tk. 5,619.58 Tk. 4,835.45 Tk. 5,880.95 Tk. 3,920.63 Tk. -
127 Linear shrinkage 1 Tk. - Tk. 2,091.01 Tk. 1,698.94 Tk. 1,969·32 Tk. 1,306.88 Tk. 1,960.32 -.
128 Shrinkage limit 1 Tk. - Tk. 1,698.94 Tk. 1.437.57 Tk. 2,613.76 Tk. 1,306.88 Tk. 1,568.25
,...-
129. Liquid limit I Plastic limit 1 Tk. - Tk. 3,528.57 Tk. 2,744.44 Tk. 3,267.20 Tk. 1,306.88 Tk. 3,267.20
130 Standard proctor 1 Tk. - Tk. 7,057.14 Tk. 5,619.58 Tk. 6,534.39 Tk. - Tk. 6,534.39 -
131 Modified proctor 1 Tk. - Tk. 8,494.71 Tk. 6,273.02 Tk. 7,841.27 Tk. 4,574.07 Tk. 7,841.27
..
132 Unit weight (wet & dry) 1 Tk. - Tk. 2,091.01 Tk. 1,829.63 Tk. 1,960.32· Tk. 1,568.25 - Tk. 1,960.32
. 133 , Void ratio (Sp. Gr. & Unit Wt.) 1 Tk. - Tk. 3,528.57 Tk. 3,136.51 Tk. 3,267.20 • Tk. 2,613.76 Tk. 3,267.20
,-
---
134 i Moisture content 1 Tk. - Tk. 1,045.50 Tk. 784.13 Tk. 980.16 Tk. 784.13 Tk. 914.81 -
135 Organic matter content 1 Tk. - Tk. 3,659.26 Tk. 3,136.51 Tk. 3,920.63 Tk.· 2,613.76 Tk. 3,397.88 -
136 loss on ignition 1 Tk. - Tk. 3,136.51 Tk. 2,613.76 Tk. 3,005.82 Tk. 0
Tk. 2,875.13 -
139 Sand equivalent test 1 Tk. - Tk. 4,704.76 Tk. 3,920.63 Tk. 4,966.14 Tk. - Tk. 4,312.70 -
-
140 Permeability (cohesive) 1 Tk. 0
Tk. 14,767.72 Tk. 5,227.51 Tk. 6,534.39 Tk. 0
Tk. 13,722.22
_. - I - ----------
(!{ ~
PWD SoR 2014 for Civil Works 235
172 Compression stiffness 1 Tk. Tk. 5,619.58 Tk. 4,835.45 Tk. 5,227.51
~--- Tk. 5,227.51
--
OTHERS
173 Tension tef (;; on Bolt, hooks 3 Tk. - Tk. - Tk. - Tk. . Tk. - Tk . -
174 Compression of fibre glass(one sample) 1 Tk. - Tk. - . Tk. 1,698.94 Tk . - Tk. - Tk. - -
--
175 Compression of timber 1 Tk. 0
Tk. 12,023.28 Tk. - Tk. - Tk. - -
180 Load test on man-hole cover (>18 inch dia) 1 Tk. - Tk. 7,710.58 Tk. 5,096.83 Tk. - Tk. - Tk. -
--
181 Tension test of fiber glass strai 'ar/pipes 1 Tk. - Tk. - Tk. 3,920.63 Tk. - Tk. - Tk. -
--
~Iastomeric Bearings
182 Vulcanized rubber and thermoplastic 3 Tk. - Tk. 5,880.95 Tk. 5,750.26 Tk. Tk. - Tk. 5,880.95 -
elastomer in tension & elongation at break
ASTM 0412
183 Short duration compression test on plain and 1 Tk. - Tk. 5.750.26 Tk. 5,619.58 Tk. Tk. - Tk. 5,880.95 -
steel laminated elastomeric bearings for
bridges. ASTM 0 4014
184 Long duration compression test on plain and 1 Tk. - Tk.11,631.22 Tk. 11,239,15 Tk. . Tk. 0
Tk. 11,761.90
steel laminated elastmeric bearings for
bridges, ASTM 04014
--
~ )WN/
-~- ' ..
PWD SoR 2014 for Civil Works 236
2 3 4 5 6 7 8 9 10
185 Determination of shear modulus, ASTM 3 Tk. Tk. 8,102.65 Tk. Tk. Tk. 9,148.15
04014
r -+- + ---f- -+~. ----l
186 Test for compression set, ASTM 0395 4 Tk. Tk. 7,318.52 Tk. Tk. Tk. 6,011.64
I . I ---t-- I
187 Determination of durometer hardness, ASTM Tk. Tk. 2,483.07 I Tk. 2,483.07 Tk. Tk. Tk.
02240
----l--------+-. ~--' -._-._--+
188 Test for rubber durability-deterioration in an 3 Tk. Tk. 4,966.14 Tk. 4.835.45 Tk. Tk. Tk. 4,835.45
air oven, ASTM 0573
'
t- --I +
189 Test for determining the adhesion on rir;j Tk. Tk. 4,051.32 Tk. 3,920.63 Tk. Tk. Tk.
I
190
substrates, ASTM 0429
OimenSiO. r.al test (external and internal) giving I Tk. Tk. 2,483.07 .~ Tk. " Tk.' . --l- 1 Tk.-.-2,483.07
WATER
------------- .-------. ---I
Drinking Water
'192 Ii Water (Drink + As), Total Package Fee Tk. Tk. Tk. 8,625.40 Tk. Tk. Tk. 7,971.96
193 Water (Orink + As + TC & FC), Total Package Tk. Tk. Tk. 10,455.03 Tk. 9,148.15 Tk. Tk.
Fee
194 pH/Hydrogen .Ion density Tk. 653.44 Tk. Tk. --+ Tk.
392.06 392.06 Tk. +------1----.
Tk. 392.06
195 I; Color (filtered) Tk. Tk, Tk. 261.38 Tk, 392,06 Tk. Tk. 392.06
_jtJ96; Carbon dioxide (C02) I Acidity Tk. Tk. 261.38 Tk. 261.38 Tk. 392.06 Tk. Tk. 261.38
L ___
197 : Chlorine (CI)
!..
~ 1 j!k! Tk~~-.. -.~ Tk. 914.81 l. Tk. ·1 Tk. 914.81-=---_ _ .~
~ ~
PWD SoR 2014 for Civil Works 237
203 Total hardness 1 Tk. 653.44 Tk. 1,045.50 Tk. 718.78 Tk. 914.81 Tk. - Tk. 914.81 -
---- ._--_.- .---------
204 Total dissolved solids (TOS) 1 Tk. 653.44 Tk. 1,176.19 Tk. 914.81 Tk. Tk. Tk. 1,045.50 - I
-----
205 Arsenic (As) 1 Tk. - 1,960~~~tn. 1,568.25 Tk. 1,960.32
.- ..
Tk. Tk. 1,829.63 - ----------1 -.
j=~=L=~-_~-j
207 Faecal Cvllform (Fe) 1 Tk. - Tk. 1,437.57 Tk. 1,045.50 Tk. - . . Tk.· - Tk .
1-' -------. --
208 Total coliform (Te) 1 Tk. - Tk. 1,437.57 Tk. 1,045.50 Tk. 1,306.88 Tk. - Tk.
-----
209 Manganese density (Mg) 1 Tk. Tk. 3,528.57 Tk. 2,091 :01 Tk. Tk. - Tk. - - I
---- -.---.-- .. --------~--
210 Sodium (Na) density (SAR) 1 Tk. Tk. 4,966.14 Tk. Tk. Tk. Tk. -
- _._---- ... ---
Pollution Study
--
211 Bio-chemical Oxygen demand (BOD)-drinking Tk. - Tk. Tk. 1,829.63 Tk. 2,352.38 Tk. 653.44 Tk. 2,091.01 -
water 1
213 Chemical Oxygen demand (COD)-Dichromate 1 Tk. - Tk. Tk. 2,091.01 Tk. 2,352.38 Tk. 653.44 Tk. 2,221.69 -
214' Dissolved Oxygen (~O) 1 Tk. - Tk. - Tk. - Tk. - Tk. 653.44 -
.. ----
215 S~lphate
-~- -- -
1 Tk. - Tk. - Tk. 718.78 Tk. 784.13 Tk. 392.06 Tk. 784.13 -
(!{ )J6rvu/
-....
PWD SoR 2014 for'Civil Works 238
1 2 3 4 5 6 ~ 8 9 10
216 Color (Scanning) 1 Tk. - Tk. - Tk. 784.13 Tk. 784.13 Tk. - Tk. - -
Miscellaneous Parameters
217 Selenium (Se) 1 Tk. 0
Tk. 3,920.63 Tk. - Tk. - Tk. - Tk. - - I
I
218 Carbonate (C03) 1 Tk. - Tk. 653,44 Tk. 326.72 Tk. 1,176.19 Tk. '261.38 Tk. 1,176.19 -
!
219 Ammonia-Nitrogeri (NH3-N) 1 Tk. - Tk. 1,306.88 Tk. 1,045.50 Tk. 1,045.50 Tk. - . Tk. 784.13 -
- - --
6~
.
-
-:.~-
Nitrate -Nitrogen (N02-N) 1 Tk. - Tk. 784.13 Tk. 653.44 Tk. 1,045.50 Tk. Tk. 4,574.07 I
1--.
Arsen~c (As) 1 Tk. - Tk. 1,960.32 Tk. - Tk. 1,960.32 Tk. 1,568_25 Tk. 1,829.63
i
223 Bromine content (Sr) 1 Tk. Tk. 653.44 Tk. 653.44 Tk. 784_13 Tk. - Tk. 653.44 -.
1~4 225
Total Chlorine content, CI2
1
Tk.
Tk.
-
-
Tk.
Tk.
784.13
784.13
Tk.
Tk_
653.44
653.44
Tk.
Tk.
784.13
784.13
Tk.
Tk.
-
-
Tk.
Tk.
653.44
---
653.44 -
1- 226"- --Break-point Chlorination 1 Tk. - Tk. 9,932.28 I Tk. 7,449.21 Tk. 9,148.15 Tk_ 3,267.20 Tk. 9,148.15
f-.-- - -: - - - - - -
~.--~2-- r- Hydrogen Sulphide (H2S) 1 Tk. - Tk. 1,045.50 Tk. 784.13 Tk. 784.13 Tk. 653.44 Tk. 784.13 -
228 Iodine content (I) 1 Tk. - Tk. 653.44 Tk. 653.44 Tk. 784.13 Tk. - Tk. 653.44 -
r--
229 Mercury (Mg; 1 Tk. - Tk. 5,619.58 Tk. 4,051.32 Tk. 5,880.95 . Tk. - Tk. 5,227.51 -.
230 Phosphate content (P04) 1 Tk. - Tk. 4,182.01 Tk. 914.81 Tk. 980.16 Tk. 522.75 Tk. 914.81 -
231 Sulphite (S03) 1 Tk. - Tk. 784.13 Tk. 849.47 Tk. 980.16 Tk. - Tk. 784.13
. 232 Silica-content (Si02) 1 Tk. . Tk. 1,306_88 Tk . 914.81 Tk. 980.16 Tk. - Tk. 1,176.19 -
-
233 Ba/CalCr/Cu/Cd/KlNa/Ni/Pb/Zn 1 Tk. - Tk. - Tk. 1,960.32 Tk_ 1,829.63 Tk. - Tk. 1,829.63 -
.," '".
234 Oil and Grease content in Water 1 Tk. - Tk. - Tk. 3,659.26 Tk. 3,267.20 Tk. Tk. 1,568.25 -
------ -~---~----.~--. ----- ---~ -.~--- --- -~--
~. ~
PWD SoR 2014 for Civil Works 239
1 2 3 4 5 6 7 8 9 10
235 . Oil and Grease content in Waste Water 1 Tk. - Tk. - Tk. - Tk. - Tk. - Tk. - -
236 Organic Matter 1 Tk. - Tk. 2,744.44 Tk. 2,352.38 Tk. 2,613.76 Tk. - Tk. 2,613.76
237 Boron (B) 1 Tk. - Tk. 3,528.57 Tk. 1,960.32 Tk. 1,829.63 Tk. Tk. 1,829.63 - !
238 Electrical co.nductivity (EC) 1 Tk. - Tk. 653.44 Tk. 653.44 Tk. 653.44 Tk. 130.69 Tk. - -
239 Total Solids (TS) 1 Tk. - Tk. 2,352.38 Tk. 914.81 Tk. 980.16 Tk. 653.44 Tk. 1,045.50 !
I
240 (TSS) or (TSS + TOS) 1 Tk. - Tk. 2,352.38 Tk. 1,829.63 Tk. 1,960.32 Tk. - Tk. 2,091.01
241 Pb or Cd release of Tableware 1 Tk. - Tk. 2,352.38 Tk. 1,829.63 Tk. 1,960.32 Tk. - Tk. 2,091.01 -
242 Extraction charge for oil 1 Tk. - Tk. - Tk. 1,829.63 Tk. - Tk. - Tk. 2,613.76 -
:
243 Extraction charge for salt 1 Tk. - Tk. Tk. 1,045.50 Tk, - Tk. Tk. 2,613,76 -
- I
~
244 Extraction of TCLP(Toxic Characteristic
1
Tk. - Tk. - - Tk. - Tk. - Tk. -
Leaching Procedure) excluding metal test
246 Boron (B) 1 Tk. - Tk. - Tk. 3,267.20 Tk. 3,528.57 Tk. - Tk. 3,267.20 -
247 Electrical co n 1uctivity (EC) 1 Tk. - Tk. 1,045.50 Tk. 653.44 Tk. 980.16 Tk. 130.69 Tk. 1,045.50
.248 Organic matter for solid, sludge 1 Tk. - Tk. 2,875.13 Tk. 1,568.25 Tk. 1,960.32 . Tk. - Tk. 1,960.32
249 Organic matter(Wet Combustion Method) 1 Tk. - Tk. 3,397.88 Tk. 2,875.13 Tk. 3,920.63 Tk. - Tk. 3,267.20 -
250 Ammonia-Nitrogen (NH3-N) 1 Tk. - Tk. 1,306.88 Tk. 1,045.50 Tk. 1,437.57 Tk. - Tk. 1,306.88 .
-. . -,. - .. ---.. .~. -. -.
~ . JWw/
-..,;.
PWD SoR 2014 for Civil Works 240
254 Arsenic (As) 1 Tk. Tk. 1,960.32 Tk. 1,568.25 Tk. 2,613.76 Tk. - Tk. 2,091.01
255 Mercury (Hg) 1 Tk. - :Tk. 5,619.58 Tk. 4,574.07 Tk. 5,227.51 Tk. - Tk. 4,574.07 -
256 Sulphite (S03) 1 Tk. - Tk. 784.13 Tk. 1,829.63 Tk. 2,613:76 Tk. - Tk. 3,267.20
257 Ca, Cd, CI, K, Mg, Na, Pb 1 Tk. - Tk. 1,960.32 Tk. 2,417.72 Tk. 2,352.38 Tk. - Tk. - -
I
265 Swimming Pool: pH, Alkalinity, Color, . Tk. - Tk. Tk. 6,273.02 Tk. 8,886.77 Tk. - Tk. 8,494.71 -
Turbidity, Total.Suspended Solids, Chloride, 1 ..
TC,FC, Fe, N03,P04
------ ----- -- - - -- --- - - ------------ -------- -------- ----- ------
(!{ )f6;w/
PWD SoR 2014 for Civil Works 241
---~----- ---
1 2 3 4 5 6 7 8 9 10
266 Textile (Only Dyeing) pH, Alkalinity, Turbidity, Tk. - Tk. - Tk. 6,795.77 Tk. 8,886.77 Tk. Tk. 8,494.71 -
Hardness, Chemical Oxygen Demand
1
(KMnO), Total Chlorine, N03, N02, Fe, Mn,
Cu, TS.
267 Textile (Boiler) pH, Alkalinity, Turbidity, Tk. .- Tk. - Tk. 6,534.39 Tk. 8,886.77 Tk. - Tk. 8,494.71
Hardness, Chemical Oxygen Demand
1
(KMnO), Total Chlorine, Ca, Fe, Mn, Si02,
S04
268 Tanning: pH, Alkalinity, Color, Turbidity,
1
Tk. Tk. - Tk. 3,005.82 Tk. 3,528.57 Tk. - Tk. -
Hardness, Fe, Mn
269 Cooling: pH, Hardness, Turbidity, Total Tk. - Tk. Tk. 4,443.39 Tk. 5,880.95 Tk. - Tk. 5.227.51 -
Dissolved Solids, Fe, Mn, COD, (KMn04), 1
P04
270 Paper and Pulp (Ground wood): pH, Alkalinity, Tk. - Tk. - Tk. 4,574.07 Tk. 6,273..02 Tk. - Tk. 5,227.51
Color, Turbidity, Hardness, Total Dissolved 1
Solids, Fe, Mn, Si02, CO2
271 Boiler Feed Water (including oil &grease): Tk. - Tk. - Tk. 5,750.26 Tk. 7,841.27 Tk. - Tk. 6,534.39
pH, Alkalinity, Color, P-Alkalinity, M-Alkalinity,
Turbidity, Hardness, Total Dissolved Solids, 1
Totaf Suspended Solids.
Air Pollution
..
273 (CO, SO, NO, CH4) excluding visit visit 3 - - - - - - -
274 SPM per three spot 3 - - - - - - -
---- ...... . ~.- ~ '. ~ - . ' .. ' ,- .. ··r ,,~. _'". _ . . -"'''''.-. -". ,~,""'''_'_~k~
...... •. ~...... .,~_ ~_ ... _. _ _ .. _ 'v_'"' .- ......." _ '" .'4.~" _.... ~ .. ., __ • , .'_~"_ .- ..... ,. ,.-~,--. ......... ~" •.. , .,. . .~.' .-~ ~- .. ~'-~'. '" L ........ • ,. ~ .~ - >.'._"-" ,-,_.
~. ~
PWD SoR 2014 for Civil Works' 242
1 2 3 4 5 6 7 8 9 10
@ JJ6;w/
PWD SoR 2014 for Civil Works 243
1/2"·4"
-
288 Pressure Test - - - - - - 3,920.63
.•
294 Filter Test - - - 3,920.63
-
5"·6"
295 Pressu. a Test - - .
- - - 5,227.51
~ )Wvu/
'''''''---
~1 i
---
~ ~
PWD SoR 2014 for Civil Works 245
Size
HBRI BRTC, BUET CRTS,KUET DCE, RUET CRTC, SUST BRTC. CUET DCE. DUET
1 2 3 4 5 6 1 8 9 10
- - - - - -
~
Tensile Test 980.16
- - - - - - ,---------
"- 329 . . Filter Test - - - - - -
-
- --.-----~--- -----
16"
1333
331
·332
Dimension Test
Aceton Test
Impact Test
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
=-1------
.
2,613.76
980.16
-------_..
1,960.32
1--
I
-- ------
334 Heat Reversion Test - - - - - - 980.16
335 Tensile Test - - - - - ~
980.16
. 336 Filter Test - - - - - - -
- ----------
~ ~
j
.---:
i per sqm per eqm I per sqm I per eqm per eqm par eqm
24586 4·
:'\'.5
27929 6
:K:':.7·
;'1
10
12 50866 12
·.13:·:/} 13
14 23665 20&14 18508 16861 31700 34410 55786 58132 30650 14
F:',1'5;?i~;\ iMtJi~~(~~~~\<'tt.~ ~;i~~,i. :t'.~ ~.... . ·~~"W.~;i1f.i. ~~~\'~~~', '. . ,,~::' •"1~f~~tlO'3.1;~; , " . jti\'$~~fl~~tJj~~~,,5l~~:.;i·r;:~;"-!~;~~'ti~:'\::iirff iW~,)!;'1Ji?)'i~f';.c:.;;~Y ':)·:'(~~%31$'t2:~·'i,t%1'5 '{;o'
16 237-94 21141 19134 64353 66251 33065 16
., ;irl:i, :~t*!~w.~~~~t ~1i~'$~W~i~;{'f-f,1;,~{if:~ ~~~1if!M~~~ ~~~~~r~,::;~:~~~;' ",.,~:{'~5U~<:c\;;-Jci.~5*~*$.\~,*,~~!t(;~1i\~j} ~1';,W~??[Fi:~;jf::X;~~:U:;;1:~\i)f.:7ij$31;Y?,~0, riifN\?~;!i~ij~;:~~J:F\? ;~::1~?;;:~2~}\i;'%\;~:. ,t~i~;'11(:'
18 271)5 23945 21554 74575 76025 35912 1B
:.'; ::::19':';:;;;; :;~':;~*;;;:~~W~1~;~lli!i~i ~%i~w.r)7~~~:~I~: :\)~~pt~~g'~ !.~ ~'i1r~~~tJti; }~fl~~!%fj.~~ ~k~~~.r;~t.ltJ;;!r~ '~!~~~J~;~~. &%~28'"~;iil~~~~~~;.~~t4f~~i~Sr; If:fl?{~!!;~){~;!1ix;::;,~j\M~k,~lfB6{flm ~J;*~:t;t9@5!\t{;;;;~;'W:::;(;3a$gs.~?:';/;Y:id9 ;:\:.
20 26909 24113 I 85330 86333 41353 20
;:\':~2:I:;\h';,~; :;c<Jr,~;SYjf~~~~~~1i~\~\}1~1)!~ ,>' ,.;.,'" ~; ~!;~1t/j~~~q:c~~:~ ~~;; }'. ~,,*~~.K""l~ ~~~lr~~s~~ ,;t.;:i;~~{,~W~:0;,,*,~;~ '~)I'~~ra'·. ' ·,,,.~;;~f~ ,~;~;';r}j'i;~9~J;!~;';:~~:~ :fi:fl:'j::#184}}:!;:: :;P;~;21., .;;;:.
22 . I 94858 95413 47086 22
';:"'23~::)£ ;~\i:;K:?M}::~;~i.,~,,*r;~ ~~'1!...'ffll!ili;i& .: .,' . . •.." . ;'~ ~~$fJt;'~¢a!~t~\?i; ~~?;i;fl!M'~~~,~A' I.I(&'i!J~~ :t~,~~ii.~£'~'>?;! [';~;::!,.~;f.;¥'if"~r..~:r ·~~:t~~~'@l~.i@'\l~'jtI~~J;g~n1fi~ ~f~'¥~~'Iif::~;~;?:;~~~J~ ?#fi~~',~J,;;"Fi" ~!!;r;;iit:t';;_:ii5it}~!f~J'~~;ij~~~OO51l\;:;lf::.: ;iil!'.~;:23 :',~
24 I 103318 103426 53097 24
Annexure-A
I
NOTES ON PLINTH AREA RATES (PLAR) \
1. PLAR are the rates to assess the cost of buildings when detail Architectural and Structural Design is
not available.
2. PLAR are formulated by studying huge vari9ables, data and assumptions only provide hints on the cost
of construction over a couple of years.
3. A wide range variation of actual cost from PLAR directs to study (i) architectural & structural design (ii) .
site condition (iii) decision built up.
4. Exclusive works relates to high density of cost rike glazed c~rtain wall, aluminium composite curtain
wall/cladding are beyond the scope of PLAR.
5. PLAR never resembles an actual cost; instead it's a probabilistic cost for fund conformity after time
dependent tender and agreement procedure to run a smooth project.
6. PLAR costs for buildings are to" be assessed after confirming the building category namely 'standard',
'super' and 'superior'.
7. 'Special' category buildings are residents/offices hold by constitutional posts or other building to be
decided by Chief Engineer, PWD and Chief Architect, Department of Architecture. The finishing
schedule and corresponding rates for these category buildi~gs are to be fixed as per actual estimate.
8. PLAR includes 19% extra cost for VAT and Other charges.
Plinth Area is the area bounded by exterior perimeter of a floor or the perimeter formed by joinin"g the
lines on the outer faces of columns in the floor, including any area kept opening what so ever, except
courtyard open to sky.
The category of buildings should be understood by the terms standard, super, superior on their usuCiI
meanings, but as a guide Standard category of buildings is that, made in quality and provided with
general basic facilities and finished components are mostly.'of local materials." bricks, sand, cement and
lime based but a hygienic finish in toilets, lavatory & kitchen.
PWD SoR 2014 for Civil Works 248
TABLE 2: PWD PLAR 2014 - SUPER STRUCTURE Rates in BOT per sqrn
ADD STRUCTURAL MEMBER WEIGHTAGE RATES (TABLE - 3) IN ADDITION TO THE RATES OF THIS TABLE
BUILDING CATEGORY
LOAD BEARING BrIck Wall System : fc= 19 To 23MPa RCC FRAME STRUCTURE:fc == 19 To 21 Mpa IRCC FRAME STRUCTURE: rc= 22 To 25 Mpa (ADO 5%
0:: NON RESIDENTIAL: NRLB A2 RESIDENTIAL: RLB A2 NON RESIDENTIAL: NRRCB A2 RESIDENTIAL: RRCB A2 NON RESIDENTIAL: NRRCS C2 RESIDENTIAL: RRC" J2 i ~
Q
~ JCQIJ~r.!tHdth_ fillj~~~~hJJ)lL_,_~..
__,_.JQ~o~.re.~~ Wllh_~!IC~~~hlp..) ICOn~l'!tfl ~Ith,_B.tIl!kiehlP~1 l~o"-~ti!I~_\Ylt~ BtJck.~hlp~1 Co"crefe with Stone'chlps COncrete with St~ne ~n~
i
.5
rr
StandataT --supef-I -Supl!rTOi'- r-Standard I Super I Superior Sfancfardl -Super _Su~erio"~T~a_ncta-"dLS~r~Supe@~ndardl~S~fleU-~Ulltinoj_T§tanc!ard! Super I Superior
4 10 11 12 I 13 1 14 1 15 16 I 17 18 I 19 1 20 21 22
GF Park I ' I 9030 I· 9632 I 10595 1 .' 9450.'1 10080 1 11088 I 9815 1 10470·.1 11517 I 10271· 1 10956 I 12052 GF Park.
kGF.i:~Hititi.itfj1~~H~~~wt::);BI· 14096" . I~l':§1<!.1~~q§:!;}.J 13829~t14.7}1[;~i)n.· 16226 ~~,r$9~]169iff I~~:i;i~,,~~;.r(rd :'16662 ." f~fj1717.2·~r195501;t~:·1~57fr18267-IT\{1Z41f2Si;i1l 172i8-[:]9.3.i8~N 21408 h;·: j: GF: Habitation
2 . 2 ~
3 + ~
4 3rd Floor
PJ!4~'J!1r~~~H:;~~~;fm1~r--139i7~'~~!1~~t,bl .' '13722 ,n~jii~M~~~1 ,16101 t;f:;~'~9JXa.·16852 ~~f~#f!.!'~~365~r1ThV~$?;1:::-19399T,~t§l3i~:1 18125 1~}~lj2'~~~1~t17864] :J~'1l!~69;;1 22198T :~5r· 4th Floor
6 6 ~
7 , 1 ' · 6th Floor
.8 7th Floor I , 15246 116263'\ 17889 \15955/117018 1 187201 15567 , 17491' 23089 116497 I 18498 120457 7th Floor
&VBth~~lOf;(~~l!f1J'i1?,l;;i*!t?bif:.f:;~:fjffi:!1;:tn~;;~~\:~;~~;~i;?;;:~t:t·";·,,,"2\~;~*-~~~]~:~':'*~NJ~Wl~i;?f~~i:~1~ES')~1~If •. ·16385~ 1i0T~Jjljp;i~r160t4-lfriiV,1~!il~1886CP~~!i.68471 -17623 .··F7i,,23.i~r;:T 16620K:18637'; ,'1 20611 I '9. 8th Floor
10 10 9th Floor
11 11. 10th Floor
g 11th Floor 16040 18022 19059 21078 12 ~
13 ·,~~-;f2OCF.iOGf?X:;I;~if.;~¥%~(fi~:J';!t:rn~l~f~tfNI~~1i:{f:~~:/ ?ii, 14df,t?\':;\ i'f6i~jh 18157 ."'19202 . 21"236 13 12th Floor
14 13th Floor 16281
L; ~
15 ;:?Kt4(ti"~~~~~h;82[;I~f$;Jt~·I~~,}:,%:~k~;. ~tin'J~'-t~~f:;;{t~~:!·;;I:·~··;/'?:A:~H;I>jYfr:-;i~iH~Ji~';;:~}"H'i~~~f~Ji}jnA;:'~~~~:;r ·I':;;:'M::;:~:{( ii~16403::':;; 14th Floor
16 15th Floor 16526 16 15th Floor
17 :;~1_~fAf~~:~1~2f~r%~~~~~~~~fJ!g~~?!~~¥'~1~~1:':!::ff;~tf.~~~~~I;f~~{~j~;i§f;g~~f&i~·;~)J;~~:~~:~1~1t~~~~'}!:~sWI¥~~kfI~1~::I;~- In;;::;~:'\~'1:;; . "~i,1665(f;;. . ..;::.17'· 16ih Floor
17th Floor 16775 18
1! ~
19 ·;,;:;;18tfi1.J~if;¥I.fEl:;;;i.~'f~i~X;'~!I:XQigt~~~l;;;;4SJi;i~~rJif;f:(:\Il,: ;).:,i;, ~'. b¥i(:l;~g;:;} X:1~901.'.. ":'19 18th Floor
~ 19th Floor 17028 20
~
21 I':-'~::;,;:!':";:h";' .' ";;1714t' 21 20th Floor
3! 21st Floor 17456 22 21st Floor
23 ',';22hrfFtc)Qt ;:<li:'1'.:i :,<E~L:':t$:d~:;;(~M:':};\ii:~;;k,l~;\,~i<·;:·:0D:;;::S~:, ."",
i ,,'hi, r~;l'i;:2"Li, :,~,~176r4, :,23 ~
24 23rd Floor 24 ~
2s :;'J.:224.tJf.JnOOi:~:J~\~f.t~:jt:f~~'~~;i\:;};(l~i~0;~~l"%iir~;,\iil:~~~tt'.~fi{!~k~;ii{. '::~Z~~'H'~*it.;~[~l~):~. ;',;>25" 24th Floor
26 25th Floor 18345 26 ~
21 ·!~~_ _~fJlj~~t~~b~«~~~;~Htf.~?;¥'~:~t~;4;~};{li~~~{ff.:~~~~i~~~~}Xht!t~i~~:;£j~~:~~lJls~}1jf~:::~~¥i~r.~·itl}:~~~?t~;~~~{~~;~:~di:;t:r(,~~;~t£:~N~~~;I· ',i';'27;: 26th Floor
28 27th Floor 18807 r. 21'f31 .·1 27893' I .19346 1 22348 I 24714 I 28 27th Floor
29 .~l3;i~~,Wi},·MEt~eN:p:i~~~~~~i4~~1~~,¥~t~1:'[~;1.f~:;:·t~~~5:;~:~t~~:.;m::~t~n~t~~~;~1~;Qt~~l~jKmI~]t~e~?~~~~Ul:1/1£~Q~~j~8}t~~~~~.~t~t~~-~:(::~'~·~,(;~;~ ~';~~W~;,t;~g.¥t~?~{:~il :~;' . ,: ·~:fi}1f.t;;i~:!'~~;~ ,"~I%~M;M 21395 -1~~;':2,m.~&.jTl19491 L,i,22~r;;,d25023 L.',29 .. 28th Floor
~ 29th Floor 30 ~
31 ·:iicff.~·~1Mt,;W(~K~~:~~~i;t~~n~f.;ff~;;r~~0:~1~~{~~lzlt&1~1~:JrJ.~·~~·~~j{I:~~Jft17:r1.~~g~~?;.~i·~1.~~iirl~~~J~~~~$: 3k\. 30th Floor
32 31st Floor 1 19765 1·.222081 29314 1'19933" 23486 , 25974 I 32 31st Floor
33 !4;~~~~ljijIlDfiflt~JjI\~~~:M£f.:.~#j~~~f,t~%i4.~~~~$~~~;iW~ft~~~~iill1~l;t#.~~~~~:t/~;~~E[~tt~~~~;~~~it.;~~i~~tf~~lt~am~~~~~~4: ...~ __ .lfriI~~;~~~t~~~f;il· (:%5b~t.4~~~~r~i IK~~~ET·2f48Ff~~~~~~Xi41: .20083 ·1::.4237ilJ0T26298 . I,:~L!,~' 32nd Floor
34 33rd Floor I· 20262 I '.22767"1 30052 '.20233 I 24077 I 26627 I 34 33rd Floor
35 Ei~Mltf~~fiif.*s,:,~,tt~;{;·~~\;Jjfi:]~':l::f:i;;'!')~"N:t?:8~j:;~';mT?'['f~(~(1;:1:i:'::'f!'iF~'~1Jt;;n?;,t:i1=~J.~if}f1J!:/\Hf';\ "f<I,?!:,t:":I .";,' :,\1~~S15\l 23051 TF~~,~04if'BI' -2C1385 Tr;.24378(.1 26960 I \35, 34th Floor
36 35th Floor 20772 23339 30808 20538 24683 27297 36 35th Floor
RoofTop LC 2135 2278 2506 2135 2278 2506 2135 2278 2506 2235 2384 2622 2156 2591 2865 2156 2591 2865 RqofTop LC
Porch 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 4857 Porch
~ ~
PWD SoR 2014 for Civil Works 249
@ ~
PWD SoR 2014 for Civil Works 250
Rate from
Structural
Member
Weightage
Tk.4,956
Table-3 +
Tk. 54,895 I Tk. 95,593 I Tk. 177,914 Tk. 2,O~9. Tk. 1,549 I Tk. 1,228 Tk. 881 Tk. 91
Tk. 5,384
*1 PLAR (Plinth Area Rate) to be calculated as sum of the costs divided by plinth area.
~ ~
PWD SoR 2014 for Civil Works 251
5. Roof-top RCC water tank in/c beams & supports etc. : Tk. 142 per gal.
7. Internal Electrification :
i
(i) Residential Building Standard Tk. 1,513.80 Persqm
Super Tk. 1,792.20 Persqm
Superior Tk. 2,134.40 Persqm
8. Gas Connection:
(i) Ground Floor Tk. 342.20 Persqm
(ii) Other Floor~ Tk. 136.88 Persqm
@: ~
PWD SoR 20.14 for Civil Works 252
(i) Boundary wall 125 mm thick with 250 x250 mm brick pillar, 1.52m in
height:
Construction of 125 mm thick boundary wall with 250 mm x 250 mm size Tk. 4,329.62 per rm
brick pillar @ 2.44 meter clc , of height 1.52 meter above G.L and 0.76 m
below G.L and RCC (fc = 19 MPa, minimumfcr =24 MPa in nominal mix 1
: 2 : 4) coping of 90 mm thick and 375 mm width, 12 mm thick plaster (1 :6)
in both sides of the wall including the cost of reinforcement and white
washing etc..
Construction of R.C.C.(fc = 19 MPa, minimum fcr =24 MPa in nominal mix Tk. 6,890.71 per rm
. 1 : 2 : 4) boundary wall of height 1.52 meter above G.L and one meter
below G.L with column 250 mm x 250 mm size and tie beam 250 mm x 250
mm at ground level, 75 mm thick and 375 mm width R.C.C coping and 125
mm (1 :4) brick work in between the columns, 12 mm thick cement plaster
(1 :6) on the both sides of brick surface and 6 mm thick cement plaster (1 :4)
on R.C.C., in all exposed surface on both sides of the boundary wall
including the cost of M.S rod white washing etc.
",
PWD SoR 2014 for Civil Works 254
Annexure-B
ROUGH ESTIMATE:
HEAD OF ACCOUNTS
• Revenue
• Development
COMPONENTS OF ESTIMATE
. CHARGES:
1. Project in Revenue Head: Charges Nil.
2. Preject in Development Head:
(a) Works undertaken by PWO for Ministry of Housing and Public Works:7.00%
(b) Works undertaken for other Ministries:8.00%
3. Deposit works:1 0.00%
DETAIL ESTIMATE
1. Report.
2. Detail Building Plan, Elevation, Section & Structural Drawings.
3. Detail measurement of each individual item along with their information in drawings, sites etc.
4. .An abstract of cost.
5. Proposed works specially boundary wall, gate, road, external water supply, sewerage line shown in red.
4. INTERNALELECTRIFICATION :Tk.D
7. Earthling system
8. Overhead transmission line
9. Underground cable laying
10. Compound light
17. QUALITY ASSURANCE, MATERIAL SAMPLE COLLECTION &TESTING, ETC (1.00% on Tk. Q) : Tk. R
18. CONTINGENCY (Probable unforeseen expenditure related to work). (5.00% on Tk. Q) : Tk~ S
. A. FOUNDATION COST
Quantity/Amount Unit Rate (Tk.) Total Amount
I (Tk.)
1. Soil Investigation : loS. or Actual cost 5 Nos. Tk. 16,364.00 INo. Tk. 81,820.00 :
(BH Nos. as primary, say) i
/2. Foundation cost: 371.97 sqm Tk. 12,697.59 Isqm " Tk 4,723,120.98
From PLAR Table -1, (For B.C.qa=3ksD
371.97 sqm @ Tk. 12,697;59 per sqm
.
!
3. Add extra 2% cost for wind (other than coastal area) & Tk. 4,723,120.98 2% 94,462.42 !
earthquake load: ITk i
i
2% on Tk 47,23,120.98 !
"A" = ITk. 4,899,403.40 ;
B. SUPER STRUCTURE COST.
4. (i) Ground floor as Parking (from PLAR Table-2) 371.97 sqm Tk.12,051.67 Isqm ITk. 4,482,857.86 i
371.97 sqm @Tk. 12051.67
I
(ii) Add extra cost for Member Weightage (M.W.) (from 371.97 sqm Tk. 978.56 Isqm Tk. 363,995.28 !
PLAR Table-3.) I
I
7. (i) 3rd floor (from PLAR Table-2) 371.97 sqm Tk. 21,551.76 /sqm Tk. 8,016,609.451
371.97 sqm @Tk.21551.76 per sqm I
(ii) Add extra cost forM.W (from PLAR Table~~) 371.97 sqm Tk. 588.49 /sqm Tk. 218,900.64J
371.97 sqm @Tk. 588.49 per sqm. . '1
8. (i) 4th floor (from PLAR Table-2) 371.97 sqm Tk. 22,198.32 /sqm Tk. 8,257,107.731
371.97 sqm @Tk. 22,198.32 per sqrn
I
I
(ii) Add extra cost for M.W (from' PLAR Table-3) 371.97 sqm Tk. 392.33 /sqm Tk. 145,933.76 i
371.97 sqm @Tk. 392.33 per sqm.
9. 5th floor (from PLAR Table-2) . 371'.97 sqm Tk. 22,864.27 /sqm Tk. 8,504,820.96
I
371.97 sqm @Tk. 22,864.27 per sqm i
"B" - Tk.45,986,466.86 ,
11~. Add extra super structure cost 2% for wind Tk. 45,986,466.86 Tk2% ITk. 919,729.34
I
(otherthanooastal area) & earth quake load resisting I.
structure. ): I
I
2% on Tk 45,986,466.86 I
I
11. Extra cost for Rooftop &Chiliakotha(From PLAR Table-2): 371.97 sqm Tk. 2,865.35 /sqm Tk. 1,065,824.00 !
371.97 sqm@ Tk. 2865.35 per sqm\ i
12. Extra cost for Roof top R.C. C Parapet (From Additional Cost 77.14 sqm Tk. 2,547.00 /sqm I Tk. 196,424.64 i
I Chart item4): !
1 4x19.28x1n=77.14sqm @ Tk. 2547.00 per sqm I I
!
13. Extra cost for Roof top.R.C.C 'water tank (From Additional 2000 gallon Tk. 142.00 /gal Tk. 284,000.00 I
Cost Chart. item-5):
2000 gal. @Tk. 142.00 per gal . I
!
IfC" = ITk. 2,465,977.98 1
~.
PWD SoR 2014 for Civil Works 260
19. (I) Ground Floor. (From Additional Cost Chart nem-8 (i) 185.99 sqm Tk. 342.20 Isqm Tk. 63,644.07
Consider 50% cost as parking.
0.50x371.97 sqm @Tk. 342.20 per sqm
(ii) Other floor (From Additional Cost Chart item-8-(ii): 1859.85 sqm Tk. 136.88 Jsqm - Tk. 254;576.27 I
5x371.97 sqm @Tk. 136.88 per sqm i
20. Construction of Compound drain ,-
i
I
Cost on running meter basis. Actual cost. a I
21. Approach Road. iI
R
As per required. (From Additional Cost Chart item-12-i/ii) I
22. (i) Boundary Wall. As per requirement.
(F rom Additional Cost Chart item-1.1-i/iiflii) S
(ii) Gate, Actual Cost (As per practical cost)
23. Site improvement. T i
24. Testing of materials as p.er requrement U i
25. Arboriculture/Landscape (As per requirement): V \
Annexure-C
(!{ ~
...l-
PWD SoR 2014 for Civil Works 262
Annexure-C
SUPER FINISH SCHEDULE FOR RESIDENTIAL BUILDING
- ~- -- - -.- - - - - - -- - - - -- - - -- - ~ - - --...::...6--
~. ~
PWD SoR 2014 for Civil Works 263
Annexure-C
SUPERIOR FINISH SCHEDULE FOR RESIDENTIAL BUILDING
. .... .,..,.---- .... ., ... _.. - ................ _.
..,,-,, ~. '\. ---- _....
INTERIOR FINISH MATERIAL EXTERIOR
NAME OF THE FINISH REMARKS
FLOOR
SPACE
FLOOR WALLS CEILING DOORS WINDOWS MATERIAL
--
rough casting I patterned paving plaster with plaster with Main door-Door
PARKING
block plastic ~aint plastic paint frame of timber,
GROUND
Local best quality homogeneous plaster with plaster with Shutter-solid wooden
STAIR LOBBY
mirror polish floor tiles. plastic paint .plastic paint (teak or other timber
Local best quality homogeneous plaster with plaster with of approved quality)
MASTER BED plastic caint decorative door with
floor tiles Iterrazo (in situ or tiles) clastic ~aint Grlll-5mm x
Local best quality homogeneous plaster with plaster with best quality polish.
OTHERS BED 19 mm. flat
floor tiles Iterrazo (in situ or tiles) plastic paint plastic paint bar with
Local best quality homogeneous plaster with plaster with enamel
DRAWING Other doors-Door Kitchen with
floor tiles Iterrazo (in situ or tiles) plastic paint plastic paint paint.
frame of timber (teak cabinet and
Local best quality homogeneous plaster with plaster with or other timber of foreign made
DINING
floor tiles Iterrazo (in situ or tiles) plastic pai~t plastic paint approved quality) hood.
Shutter-
local best quality sliding Plaster with
ceramic wall tilel aluminum weather coati
Local best quality homogeneous plaster with Shutter-Particle board
KITCHEN terrazo (in· situ or fabricated exposed brick·
floor tiles Iterrazo (in situ or tiles) plastic paint flush door of wood M.S box or G.!.
tile) upto 2100 with glass with pointing
TYPICAL mm height veneer with best stair railing with
shutter.
quality polish. wooden I G.I.
local best quality hand rail of
local best quality ceramic floor plaster with
TOILET ceramic wall tile
tiles plastic paint approved
upto false ceiling Window
Main gate-MS .. sheet design.
frame-
Local best quality homogeneous plaster with plaster with with M.S. angle/ S.S.
STAIR LOBBY aluminum
mirror pOli$h floor tiles. plastic paint plastic paint sheet with S.S. pipe
fabricated
as per deSign.
Local best quality homogeneous frame.
plaster with plaster with
STAIR glazed floor tiles Iterrazo (in situ or
plastic paint plastic paint
tiles) with brass of bronze nosina
Bathroom door-
CORRIDOOR Local best quality homogeneous plaster with plaster with Wooden door with
I PASSAGE f ~Iazed floor tiles IterrazQ (in situ or plastic paint plastic paint lacquer coating
tiles) (inside)
~ ~
-:....-
_.-c-
Annexure-C
SPECIAL FINISH SCHEDULE FOR R'ESIDENTIAL BUILDING
FLAT TYPE - 2500 sft. and ABOVE
NAME OF
FLOOR
SPACE
FLOOR SKIRTING WALL, CEILI,.ING DOOR WINDOW COMMENTS I
Rough & textured Plastic paint of Plastered &
DRIVE WAY & concrete tile of approved color painted with
PARKING approved color white plastic
design & size. paint I
Homogeneous tiles Homogeneo Plastic paint of Plastered & Solid wooden Aluminum sliding window with 6 Stainless steel i
of approved color us tiles of approved color painted with door of mm x 25 mm flat M.S bar grill as railing of
with nosing stair color white plastic approved design per design. Fly proof net. Frame: approved
STAIR
strips/terrazo with pa'int. in roof top. silver colour anodized. Glass: design with I
brass nosing. light brown tinted type. Grill wooden or s.'s I
~ ~
PWD SoR 2014 for Civil Works 265
--ill'
Annexure-C
-- -
NAME OF --COMMENTS I
FLOOR FLOOR SKIRTING WALL CEILLING DOOR WINDOW
SPACE
!
100 mm high Solid wooden designed ~oor Aluminum sliding ~indow with 6
Local best quality skirting local Plastic paint of Plastered & with check viewer, security min x 25 mm flat M.S bar grill as
homogeneous best quality approved color on painted with chain, door knocker, apartment per design. Fly proof net. Frame:
FOYER
tiles of approved homogeneous plaster upto false white plastic number plate, mortice lock, silver colour anodized. Glass:
color. tiles of floor ceiling. paint. tower bolt and magnetic door light brown tinted type. Grill color:
color. stopper inside room. of approved enamel paint.(if any)
-
Aluminumsliding window with 6
Mirror polished 100 mm high Plastered &
local best quality skirting with mm x 25 mm flat M.S bar grill as
Plastic paint of Aluminum sliding door. Frame:
LIVING painted with per deSign. Fly proof net. Frame:
ROOM homogeneous homogeneous approved color on silver colour anodized. Glass:
white plastic silver colour anodized. Glass:
tiles of approved tiles of floor plaster. light brown tinted type.(if any)
TYPICAL paint. light brown tinted type. Grill color:
c Jr. color.
FLOOR of approved enamel paint.
~ ~
--..l::""-
..::--..---
---
Annexure-C
- .. ------- .----
NAME OF COMMENTS·
FLOOR FLOOR SKIRTING WALL CEILLING DOOR WINDOW
SPACE
Wooden (Garjan or
other timber of
Aluminum sliding
approved quality)
window with 6 mm x
louvred catdoor
25 mm flat M.S bar
Ceramic wall tiles direcly above door
Ceramk. floor Plastered & Solid wooden door with grill as per design. Fly with same width
of approved
I TOILET
tiles (non-skid)
of approved
colour &size upto
bottom of false
painted with
white plastic
mortice lock & tower bolt.
Coated with lacquer paint
proof net. Frame:
silver colour anodized.
upto ceiling painted
with enamel paint of.
color & size. . ceiling .
paint (inside) . GlasS: light brown
tinted type. Grill color:
wall color and fly
proof net inside. 38
- of approved enamel
paint
mm high door sill !
maids toilet 150 rnm I
"---
~h door s~!:...____ .. .J
Aluminum sliding !
TYPICAL Door frame of (teak or window with 6 mm x i
!
FLOOR 100 mm high other timber of approved 25 mmflat M.S bar
Homogeneous skirting with Ceramic wall tiles Plastered & quality) shutter-particle grill as per design. Fly
.tiles /terrazo (in homogeneous of approved painted with board flush door of wood proof net. Frame:
Kitchen with cabinet i
and foreign made
KITCHEN
situ or tile) of tiles / terrazzo colour & size upto white plastiC veneer with mortice lock, silver colour anodized.
hood.
I
approved color. (in situ) of 2100 mm height. paint tower bolt, magnetic door Glass: light brown
floor color stopper inside room and tinted type. Grill color:
best quality polish. of approved enamel
paint.
--
Local best Solid wooden door of
quality
100 mm high. Plastered & (teak or other timber of
Stainless steel/Mild
skirting with Plastic paint of steel railing of
homogeneous p~inted with approved quality) with
VERANDAH homogeneous approved color on approved design
non-skid glossy white plastiC mortice lock &tower bolt.
tiles of floor plaster. with 25 mm high
tiles of paint Coated with lacquer paint
color door sill.
approved color. > only in outside.
~ ~
PWD SoR 2014 for Civil Works 267
Annexure-D
NAME OF THE MATERIAL BRAND AS USER GUIDE*
(SUBJECT TO SATISFY THE STANDARD. TESTS AND APPROVAL BY PWD)
!
SL. NAME OF THE MATERIAL AND STANDARD*' BRAND NAME MANUFACTURER
\1
1.1 ANCHOR Olympic Cement Ltd.
Green Grandeur
58/E, Kemal Ataturk Avenue( 11 th Floor}
Banani, Dhaka-1213
Phone: 9821503,9821504
1.20
2.8·
2.9
2.10
2.11
3.9
·3.10
I
PWD So~ 2014 for Civil Works 270
4.2
4.3
5. uPVC PIPES FOR PORTABLE WATER 5.1 NPI National Polymer Industries Ltd.
- SUPPLY AND FlmNGS 36, Lake Circus Kalabagan,Dhaka
BOS 1496:2006 Phone: 02-8115054-57
BS 3505: 1986
5.2
ISO 4422-2:1996 (E)
5.3
7.4
9.2 RAK
Phone: 02-8012327
RAK Sanitary Wares (Bangladesh) Ltd.
I
. RAK Tower (7th , 81h&9 Floor), Plot #1/A. Jasimuddin
Avenue, Sector # 3, Uttara Model Town, Ohaka-1230
I
Phone: 8917393, 8922285, 8912303
10. CERAMIC TILES 10.1 ATI ATI Ceramic ltd. '
80S ISO 13006:2006 Khwaja Enayetpure® Tower, 17, Bir Uttam K.M.
Shafiul\ah Road (Green Road), Ohaka.. 1205
Phone: 02-9662611 ..4, 8628423-4
PWD SoR 2014 for Civil Works 271
i
I
I 10.2 CBC Tiles China Bangia Ceramic Industries Ltd.
f National Plaza (5 th floor),
109, Bir Uttam C.R Dutta Road Dhaka-12D5
Phone: 8615922,9668278-9
10.3 FU-WANG Fu-Wang Ceramic Industry Ltd.
204/B (4th Floor), Sir Uttam Mir Shawkat RQad, Tejgaon-
Guishan Link Road, Dhaka-1208 :;
Phone: 9883274-5, 8825573, 88239~5t4,··
10.4 GREAT WALL GreatWall Ceramic Industries Ltd.
1311, Paribagh, BirUtlom C.R.Dutte Road, Dhaka-1000.
I
I
Phone: 9666308,9664607 I
10.5 MIRCERAMIC Mir Ceramic Ltd.
House No. 13, Road No.12, Dhanmondi RIA Dhaka-1209
Phone: 8110131,8110997, 9134572-3
10.6 RAK RAK Ceramics (Bangladesh) Ltd.
RAK Tower (7 th , 81h & 9 Floor), Plot#1/A, Jasimuddin
Avenue, Sector # 3, Uttara Model Town, Dhaka-1230
Phone: 8917393,8922285,8912303
\
Ii
Building-34, Road-12, Block-K I
Baridhara Diplomatic Zone, Dhaka-1212 I
I
I 12.4 I
I