FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-1) DISPLAY DESIGN
note) Note When power is out due to an instant power failure or the problems in an electric circuit and
restored again , the ref checks R-Room Temp. At this time, When F-Room Temp is lower than
℃ Ref considers it as an instant power failure and restores the previous temp and functions
5℃
stored in EEPROM for use.
1. QUICK FREEZING
1) When Quick Freezing is selected by pressing Quick Freezing Button, ICON gets on immediately but Quick
Freezing starts its operation after 10 sec. However, when Quick Freezing Button is reselected during Quick
Freezing, ICON gets off and operation ends with the selection of Quick Freezing.
2) When Quick Freezing is selected, Comp & F-Fan operates continuously for 2hr. and 30min.
3) During Quick Freezing, R-Room continues its previous operation.
4) After turning off Quick Freezing, Quick Freezing lamp goes off automatically and F-Room operates
according to the set temp.
5) When it becomes conditions for Defrost during Quick Freezing, Defrost gets delayed and it starts operating
upon completion of Quick Freezing.
When Quick Freezing is selected during Defrost, Quick Freezing ICON lights up immediately. But, Comp
and F-Fan gets on upon completion of Defrost.
23
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-4) VACATION
1. VACATION
1) When Vacation is selected by pressing Vacation Button, ICON gets on immediately but Vacation starts its
operation after 10 sec.
2) When the temp set in R-Room is selected during Vacation, Vacation is cancelled immediately.
3) When Vacation is selected, the temp DISPLY (7-SEG) in R-Room will be off and when Vacation is
cancelled, the temp DISPLY in R-Room will be on.
4) When Forced Operation and Forced Defrost operate during Vacation, Vacation stops immediately.
5) When Vacation operates again, the temp in R-Room will be at 12 ℃.
�Among the functions depending on Ambient Temp, Comp Cooling Fan (Comp Room Fan) is controlled
according to Ambient Temp as follows.
Therefore, make sure to check the contents to refer to during A/S because Cooling Fan can operate or it
can’ t according to conditions during Comp operation,
24
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-6) DEFROST
�If F Defrost HEATER doesn‘ t reach to the point of Defrost OFF in 90 min., turn off forcibly and
complete F-Defrost. ( Prevention of inferior HEATER OPEN or inferior F-Room Defrost Sensor )
10-7) ALARM
1. Button TOUCH
1) When selecting each button in the CONTROL PANEL, the verification sound (Ding Dong) of input
shall be heard.
2) In the case of pressing more than two KEYS at the same time or pressing the wrong button, sound
will not be heard.
2. DOOR-OPEN
1) After passing 2 min. consecutively as F/R-Room DOOR opened, SOUND alarm (Ding Dong) shall
be heard.
2) If the door is still open afterward, sound alarm shall be circulated to SOUND (Ding Dong)
generating movement at the interval of a min.
3) Alarm stops when F/R-Room are all closed.
1) In the case of instant power failure and initialization of PANEL DISPLAY, it can make customer’ s
NON-SENSE CALL. To avoid this, if power is applied, it judges the temp of F-Room and operates
as either initialization or restoration of operation conditions.
2) With initial POWER ON, it judges the temp of F-Room and if it is below +5 ℃, it is judged as instant
power failure while operating and restoring the functions related to PANEL DISPLAY such as quick
freezing, CHILD LOCK and F/R-Room settings.
3) With initial POWER ON, it judges the temp of F-Room and if it is above +5 ℃, it is judged as
extended power failure and PANEL DISPLAY will be initialized (Automatic setting at - 20℃ ℃ for F-
Room and 3℃ ℃ for R-Room).
25
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-9) TEST (FORCED OPERATION / FORCED DEFROST)
�When pressing R-Room temp regulating KEY and ice selection KEY in PANEL PCB
simultaneously for more than 8 sec, PANEL DISPLAY will go off and it moves onto TEST MODE. At
this point, although F/R-room temp regulating KEY, quick freezing KEY, and ice selection KEY are
pressed, it operates by TEST KEY.
�When pressing TEST KEY, Test function shall be changed in the order as Forced Operation →
Forced F Defrost → Cancellation (normal operation) → Forced Operation.
If functions are canceled during the operation of TEST function, it is most desirable to turn off
the power and turn it on again.
Press for 8 sec
1. Forced Operation
1) When pressing TEST KEY once in TEST MODE, Forced Operation will be selected and with BEEP
sound, alarm will go off.
2) If Forced Operation is selected, COMP. operates instantly without 5 min. delay in any operation MODE. At
this point, if it is in Defrost, Defrost will be stopped instantly.
3) With the selection of Forced Operation, COMP. and F FAN operate for 24 hr. continuously and R-room will
be regulated by the set temp while forced operation continues until the completion of forced operation or
the conversion to other MODE (forced F Defrost) or cancellation.
4) With the selection of forced operation, F-room will be selected at “ MAX -25 ℃”and R-room will be set at
“ MID 2 ℃”automatically. However, although Forced Defrost or Test Cancellation is selected after a
minute while selecting forced operation, the set temp will not change. (Maintaining “ MAX -25℃”and
“ MID 2℃”) If forced defrost or test cancellation are selected in a minute while selecting forced operation,
the set temp will go back to the previous set temp before “ MAX -25℃”and “ MID 2℃”.
5) On the completion of Forced Operation (24 hr.), F Defrost shall be executed regardless of the previous
state.
6) After the above items, it operates under the conditions of normal defrost by judging case by case.
7) If it is cancelled randomly during forced operation, (On changing into Cancellation Mode), the time for
COMP. ON during forced operation shall be calculated in total and reflected in defrost cycle.
8) During forced operation, quick freezing doesn’ t function and with the selection of function, LED indication
for the selected POWER function will be off after 10 sec.
2. Forced Defrost
1) When pressing TEST KET twice in TEST MODE, F-room defrost will operate and BEEP sound alarm
shall be heard.
2) BEEP sound alarm shall operate until the completion of HEATING and pause.
3) With the selection of forced F defrost, it will operate regardless of the point of normal Heater On and
complete defrost while comparing the temp of the point of HEATER OFF.
3. TEST Cancellation MODE
1) When converting DISPLAY PANEL into TEST MODE and pressing TEST button one more time during F
Defrost, F Defrost will be cancelled and restored to normal operation. Also, if MAIN POWER is turned on
again after being turned off, all the TEST functions will be canceled.
26
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-10) SELF-DIAGNOSIS
27
FUNCTIONS & HOW-TO-USE BY PRODUCTS
Details of self-diagnosis lighting by position
1) When pressing “ Vacation KEY + Quick Freezing KEY ” simultaneously for 6 sec. in normal
operation, the indicators of temp set in F/R-room will all ON/OFF for 2 sec. at the interval of 0.5
sec. At this point, when pressing the Temp Set Key in R-Room while canceling “ Vacation KEY +
Quick Freezing KEY ”, it operates load status display.
2) Load status display will show the load in operation REAL TIME. However, it is not related to real
status of operation of load and it only shows the directed status of the load operation command
from MICOM.
3) Only corresponding ICON for the load in operation will be ON/OFF repeatedly and turned off.
4) Load status display will continue for 30 sec. and it will restore to the normal state.
28
FUNCTIONS & HOW-TO-USE BY PRODUCTS
Conditions
1 upon LED ON when ambient temp is over 35 ℃
verload
Conditions
2 upon low LED ON when ambient temp is lower than 17 ℃
temp
Exhibition
3 LED ON with display mode
Mode
F-Room
7 Defrost LED ON when F-Room defrost heater operates
Heater
SABBATH
10 When selecting SABBATH (Only for ISRAEL model)
MODE
29
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-12) OPTION SETTING
�When pressing R-Room temp setting KEY and Vacation KEY simultaneously for 12 sec, DISPLAY will
convert to Option Setting MODE.
1. For example, if you want to set option and SHIFT the standard temp of F-Room to -3℃, follow the irections
below.
This function is to change the standard temp and if the standard temp at present is at F-Room (MID -18 ℃),
it can be lowered by -3℃ via using options and the standard temp will be controlled at -21℃ That is, in the
case of changing temp option, although you set it at -18℃ on the display panel, the fridge will operate at -21
℃ internally. Therefore, when you set the standard temp at -3℃, temp will lowered by -3 ℃ additionally
compared to that set on the display panel while controlling.
1) Press F-Room temp setting key and Quick Freezing KEY simultaneously for more than 12 sec. as shown
in the picture.
- All DISPLAY will be OFF except for F/R-Room temp indicating DISPLAY.
2) After changing into Option Mode, DISPLAY will show "0" for R-Room and "0" for F-Room.
(When shipping of the products, there shall be "0" for R-Room and "0" for F-Room but for the purpose of
quality improvement while producing, the standard setting value can be changed.)
- If "0" for R-Room is indicated, temp option item in F-Room will be set and temp setting value of F-Room
at present will be shown in temp DISPLAY for F-Room.
3) After setting "0" in R-Room and selecting "6" as in the option table of F-Room below, the standard temp
of F-Room will be lowered by 3 degree Celsius. (Refer to the picture of temp change in F-room )
: If you wait for 20 sec. after the completion of adjusting, MICOM will store the set value in EEPROM and
restore to normal DISPLAY while canceling option setting mode.
4) Since option is already set in EEPROM while shipping, do not change it randomly except for the
special occasions and do not turn off power before restoring to normal display because option is
completed as long as it can restore to normal display after 20 sec.
note) Basically, when shipping of the products, data are all cleared in Option.
That is, the Set Values are all 0 .However, for the purpose of quality improvement while
producing, the part of set values is altered and manufactured.Therefore, make sure to check
quality information.
30
FUNCTIONS & HOW-TO-USE BY PRODUCTS
Example of application) In the case of decreasing the standard temp of Freezer by -3 ℃
Example of application) In the case of increasing the standard temp of Fridge by +1.5 ℃
31
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-13) OPTION TABLE
note) When using the temp set S/W in F-Room and Vacation S/W, other options except for the above
mentioned functions re ALREADY set.Those are the items related to the refrigerator control and
they will be omitted since it is not necessary for A/S. (Do not set other options except for those in
the above A/S MANUAL.
Table for changing temp in F-Room Table for changing temp in R-Room
SET ITEM F-ROOM TEMP SHIFT SET ITEM R-ROOM TEMP SHIFT
MODEL TD-PJT MODEL TD-PJT
LOCATION : R-ROOM 7-SEG LOCATION : R-ROOM 7-SEG
DISPLAY DISPLAY
0 1
SET VALUE SET VALUE SET VALUE SET VALUE
COMMON COMMON COMMON COMMON
F-ROOM 7-SEG F-ROOM 7-SEG F-ROOM 7-SEG F-ROOM 7-SEG
0 0 8 +0.5℃ 0 0 8 +0.5℃
1 -0.5℃ 9 +1.0℃ 1 -0.5℃ 9 +1.0℃
2 -1.0℃ 10 +1.5℃ 2 -1.0℃ 10 +1.5℃
3 -1.5℃ 11 +2.0℃ 3 -1.5℃ 11 +2.0℃
4 -2.0℃ 12 +2.5℃ 4 -2.0℃ 12 +2.5℃
5 -2.5℃ 13 +3.0℃ 5 -2.5℃ 13 +3.0℃
6 -3.0℃ 14 +3.5℃ 6 -3.0℃ 14 +3.5℃
7 -3.5℃ 15 +4.0℃ 7 -3.5℃ 15 +4.0℃
32
FUNCTIONS & HOW-TO-USE BY PRODUCTS
- PCB DIAGRAM