You are on page 1of 12

10.

Operation Function
10-1) Digital Panel ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙20

10-2) Temperature Control Function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙20


10-3) Power Freeze and Power cool Functions ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 20

10-4) Sound Function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21


10-5) Defrost Function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21

10-6) Forced Operation Function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 22


10-7) Power failure compensating Function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
10-8) Exhibition Function∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
10-9) Self - Diagnostics Function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 23
10-10) Component Load Operation Function. ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 24
10-11) C-Fan Motor Delay function ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 25

22
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-1) DISPLAY DESIGN

10-2) TEMP CONTROL

1. F-Room Temp Setting


℃ and R-Room will be set at 3℃
1) With the initial power on, F-Room will be set at -20℃ ℃ automatically.
At this time, the temp on the display panel means the temp in the fridge and as the temp decreases,
the displayed temp also decreases down to set temp. Afterward, the displayed temp is the set temp.
(Displayed range of actual temp: From 30℃ to -35℃)
2) F-Room Temp can be set from -14℃ ℃ to -25℃
℃ with F-Room temp setting buttons.

2. R-Room Temp Setting


1) R-Room Temp can be set from 7℃ ℃ to 1℃℃ with R-Room temp setting buttons.
2) R-Room set temp varies slightly from actual temperature according to the user’s way of storing food
and Ambient temp. (If food is stored too close to R-Room Temp Sensor, it can block air circulation
resulting in weak or over cooling. So, be careful not to block it.) (Displayed range of actual temp: From
30 ℃ to -9 ℃)

note) Note When power is out due to an instant power failure or the problems in an electric circuit and
restored again , the ref checks R-Room Temp. At this time, When F-Room Temp is lower than
℃ Ref considers it as an instant power failure and restores the previous temp and functions
5℃
stored in EEPROM for use.

10-3) QUICK FREEZING

�It is selected with Quick Freezing Button.


�Each time you press Quick Freezing Button, it repeats SELECT ↔ CANCEL (Relevant ICON ON/OFF).
�When Quick Freezing is selected, the temp settings of R/F-Room do not change.
�When Quick Freezing is selected, it is possible to change the temp settings of R/F-Room.

1. QUICK FREEZING
1) When Quick Freezing is selected by pressing Quick Freezing Button, ICON gets on immediately but Quick
Freezing starts its operation after 10 sec. However, when Quick Freezing Button is reselected during Quick
Freezing, ICON gets off and operation ends with the selection of Quick Freezing.
2) When Quick Freezing is selected, Comp & F-Fan operates continuously for 2hr. and 30min.
3) During Quick Freezing, R-Room continues its previous operation.
4) After turning off Quick Freezing, Quick Freezing lamp goes off automatically and F-Room operates
according to the set temp.
5) When it becomes conditions for Defrost during Quick Freezing, Defrost gets delayed and it starts operating
upon completion of Quick Freezing.
When Quick Freezing is selected during Defrost, Quick Freezing ICON lights up immediately. But, Comp
and F-Fan gets on upon completion of Defrost.
23
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-4) VACATION

�It is selected with Vacation Button.


�Each time you press Vacation Button, it repeats SELECT ↔ CANCEL (Relevant ICON ON/OFF).
�When Vacation is selected, the temp settings of R/F-Room does not change.

1. VACATION
1) When Vacation is selected by pressing Vacation Button, ICON gets on immediately but Vacation starts its
operation after 10 sec.
2) When the temp set in R-Room is selected during Vacation, Vacation is cancelled immediately.
3) When Vacation is selected, the temp DISPLY (7-SEG) in R-Room will be off and when Vacation is
cancelled, the temp DISPLY in R-Room will be on.
4) When Forced Operation and Forced Defrost operate during Vacation, Vacation stops immediately.
5) When Vacation operates again, the temp in R-Room will be at 12 ℃.

10-5) FAN MOTOR DELAY (COMPRESSOR ROOM)

�Among the functions depending on Ambient Temp, Comp Cooling Fan (Comp Room Fan) is controlled
according to Ambient Temp as follows.
Therefore, make sure to check the contents to refer to during A/S because Cooling Fan can operate or it
can’ t according to conditions during Comp operation,

Range of Ambient temp Load operation state


Above 18 ℃ With COMP.ON, Comp Room Fan
will be on immediately
Comp Room Between 13 ℃ and 17 ℃ After 5 min. from COMP.ON, Comp
DELAY Room Fan will be on
Below 12 ℃ Regardless of COMP., Comp Room
Fan will be off

24
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-6) DEFROST

1) F-Room Defrost will be determined by COMP ON Total hour.


2) On the initial POWER ON, Defrost in F-Room shall be executed after COMP ON total hour of 4 hr.
3) Defrost cycle changes automatically depending on the conditions from MIN 6 hr. to MAX 11 hr.
4) The judgment of defrost cycle shall be determined by Ambient temp, No. of DOOR OPEN in F/R-
Room, and the time for DOOR OPEN in F/R-Room.
5) Point of Defrost HEATER OFF is as follows when it is compared by the temp value of F Defrost
SENSOR.

Classification F-Room Others


Defrost cycle 6 hr. / 8 hr. / Initial 4 hr. 12 hr.
Defrost restoration temp 12 ℃ (Refer to Option) 10 ℃
Condition of general defrost 12 ℃ (Refer to Option)
Forced defrost in frost -for A/S
remove mode

�If F Defrost HEATER doesn‘ t reach to the point of Defrost OFF in 90 min., turn off forcibly and
complete F-Defrost. ( Prevention of inferior HEATER OPEN or inferior F-Room Defrost Sensor )

10-7) ALARM

1. Button TOUCH
1) When selecting each button in the CONTROL PANEL, the verification sound (Ding Dong) of input
shall be heard.
2) In the case of pressing more than two KEYS at the same time or pressing the wrong button, sound
will not be heard.
2. DOOR-OPEN
1) After passing 2 min. consecutively as F/R-Room DOOR opened, SOUND alarm (Ding Dong) shall
be heard.
2) If the door is still open afterward, sound alarm shall be circulated to SOUND (Ding Dong)
generating movement at the interval of a min.
3) Alarm stops when F/R-Room are all closed.

10-8) RESTORATION OF OPERATION CONDITIONS FOR POWER FAILURE

1) In the case of instant power failure and initialization of PANEL DISPLAY, it can make customer’ s
NON-SENSE CALL. To avoid this, if power is applied, it judges the temp of F-Room and operates
as either initialization or restoration of operation conditions.
2) With initial POWER ON, it judges the temp of F-Room and if it is below +5 ℃, it is judged as instant
power failure while operating and restoring the functions related to PANEL DISPLAY such as quick
freezing, CHILD LOCK and F/R-Room settings.
3) With initial POWER ON, it judges the temp of F-Room and if it is above +5 ℃, it is judged as
extended power failure and PANEL DISPLAY will be initialized (Automatic setting at - 20℃ ℃ for F-
Room and 3℃ ℃ for R-Room).

25
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-9) TEST (FORCED OPERATION / FORCED DEFROST)

�When pressing R-Room temp regulating KEY and ice selection KEY in PANEL PCB
simultaneously for more than 8 sec, PANEL DISPLAY will go off and it moves onto TEST MODE. At
this point, although F/R-room temp regulating KEY, quick freezing KEY, and ice selection KEY are
pressed, it operates by TEST KEY.
�When pressing TEST KEY, Test function shall be changed in the order as Forced Operation →
Forced F Defrost → Cancellation (normal operation) → Forced Operation.
If functions are canceled during the operation of TEST function, it is most desirable to turn off
the power and turn it on again.
Press for 8 sec

1. Forced Operation
1) When pressing TEST KEY once in TEST MODE, Forced Operation will be selected and with BEEP
sound, alarm will go off.
2) If Forced Operation is selected, COMP. operates instantly without 5 min. delay in any operation MODE. At
this point, if it is in Defrost, Defrost will be stopped instantly.
3) With the selection of Forced Operation, COMP. and F FAN operate for 24 hr. continuously and R-room will
be regulated by the set temp while forced operation continues until the completion of forced operation or
the conversion to other MODE (forced F Defrost) or cancellation.
4) With the selection of forced operation, F-room will be selected at “ MAX -25 ℃”and R-room will be set at
“ MID 2 ℃”automatically. However, although Forced Defrost or Test Cancellation is selected after a
minute while selecting forced operation, the set temp will not change. (Maintaining “ MAX -25℃”and
“ MID 2℃”) If forced defrost or test cancellation are selected in a minute while selecting forced operation,
the set temp will go back to the previous set temp before “ MAX -25℃”and “ MID 2℃”.
5) On the completion of Forced Operation (24 hr.), F Defrost shall be executed regardless of the previous
state.
6) After the above items, it operates under the conditions of normal defrost by judging case by case.
7) If it is cancelled randomly during forced operation, (On changing into Cancellation Mode), the time for
COMP. ON during forced operation shall be calculated in total and reflected in defrost cycle.
8) During forced operation, quick freezing doesn’ t function and with the selection of function, LED indication
for the selected POWER function will be off after 10 sec.
2. Forced Defrost
1) When pressing TEST KET twice in TEST MODE, F-room defrost will operate and BEEP sound alarm
shall be heard.
2) BEEP sound alarm shall operate until the completion of HEATING and pause.
3) With the selection of forced F defrost, it will operate regardless of the point of normal Heater On and
complete defrost while comparing the temp of the point of HEATER OFF.
3. TEST Cancellation MODE
1) When converting DISPLAY PANEL into TEST MODE and pressing TEST button one more time during F
Defrost, F Defrost will be cancelled and restored to normal operation. Also, if MAIN POWER is turned on
again after being turned off, all the TEST functions will be canceled.

26
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-10) SELF-DIAGNOSIS

Press for 8 sec

1. Self-diagnosis with initial POWER ON


1) With POWER ON, it shall diagnose the status of temp SENSOR in a minute in MICOM internally for
itself.
2) If inferior sensor is found after self-diagnosis, corresponding DISPLAY ICON will be all off at the
interval of 0.5 sec. and there shall be no sound with ICON ON. (Refer to the following the details of
self-diagnosis lighting by position)
3) In the state that inferior sensor is found and DISPLAY ICON is off, it only recognizes self-diagnosis
KEY (Press Vacation KEY + Quick Freezing KEY for 8 sec.) and normal temp control will be on
hold.
4) On self-diagnosis ERROR, if inferior sensor is fixed or if you press Vacation KEY + Quick Freezing
KEY for 8 sec., it will be canceled automatically.
2. Self-diagnosis during normal operation
1) When pressing “ Vacation KEY + Quick Freezing KEY ” simultaneously for 6 sec. in normal
operation of the fridge, the temp set DISPLAY will be All ON/OFF for 2 sec. at the interval of 0.5
sec. and when pressing “ Vacation KEY + Quick Freezing KEY ” simultaneously for 8 sec. including
TOGGLE for 2 sec., self-diagnosis will be selected.
2) At this point, “ SOUND ” shall be heard and it operates self-diagnosis.
3) When self-diagnosis operates, entire LED will be OFF and only relevant LED with malfunction will
be ON / OFF repeatedly signifying defects. (Refer to the below self-diagnosis CHECK LIST)
4) When an ERROR occurs, it will be indicated for 30 sec. and restored to the normal status
regardless of maintenance.
5) During self-diagnosis KEY input will not be recognized.

27
FUNCTIONS & HOW-TO-USE BY PRODUCTS
Details of self-diagnosis lighting by position

No ITEM DISPLAY LED TOURBLE SHOOTING REMARK

Fall out R-Room Sensor Indicating a defect


Housing, contact failure, when the temp
1 R-SENSOR
breakage of wire, short sensing of R-Sensor
circuit, inferior R-Sensor is above +65℃ or
and etc. below -50℃.

Fall out Damper Heater Indicating a defect


2 DAMPER
Housing, contact failure, when sensing below
SENSOR
and breakage of wire. +2.0V

Fall out Ambient Sensor Indicating a defect when the


3 AMBIENT ousing , contact failure, temp sensing of Ambient
SENSOR breakage of wire, short circuit, Sensor is above +65℃ or
inferior ambient sensor and etc. below - 50℃.

Fall out F-Room Sensor


F-ROOM Indicating a defect when the
ousing, contact failure,
4 DEFROST temp sensing of F-Sensor is
breakage of wire, short circuit,
SENSOR above +65℃ or below -50℃.
inferior F-Sensor and etc.

Fall out Defrost Sensor ousing Indicating a defect when the


F-ROOM in the evaporator in F-Room, temp sensing of F Defrost
5 DEFROST contact failure, breakage of Sensor is above +65℃ or below
SENSOR ire, short circuit, inferior sensor -50℃.
and etc.
Fall out Heater Housing,
F DEFROST ontact failure, breakage of On F Defrost 90min.
6 SENSOR wire, short circuit, inferior F- automatic completion
Heater or inferior Defrost temp
fuse and etc.

9-11) LOAD STATUS DISPLAY

1) When pressing “ Vacation KEY + Quick Freezing KEY ” simultaneously for 6 sec. in normal
operation, the indicators of temp set in F/R-room will all ON/OFF for 2 sec. at the interval of 0.5
sec. At this point, when pressing the Temp Set Key in R-Room while canceling “ Vacation KEY +
Quick Freezing KEY ”, it operates load status display.
2) Load status display will show the load in operation REAL TIME. However, it is not related to real
status of operation of load and it only shows the directed status of the load operation command
from MICOM.
3) Only corresponding ICON for the load in operation will be ON/OFF repeatedly and turned off.
4) Load status display will continue for 30 sec. and it will restore to the normal state.

28
FUNCTIONS & HOW-TO-USE BY PRODUCTS

Press for 8 sec ①

Details of load status display lighting by position

No ITEM DISPLAY LED TROUBLE

Conditions
1 upon LED ON when ambient temp is over 35 ℃
verload

Conditions
2 upon low LED ON when ambient temp is lower than 17 ℃
temp

Exhibition
3 LED ON with display mode
Mode

4 Damper LED ON when Damper gets open

5 COMP LED ON when Comp operates

6 F-FAN LED ON when F-FAN operates

F-Room
7 Defrost LED ON when F-Room defrost heater operates
Heater

8 C-FAN LED ON when C-FAN operates

General First digit “ E, F ” LEDs of R-Room goes off when ambient


9
conditions temp is between 18 ℃ and 34 ℃

SABBATH
10 When selecting SABBATH (Only for ISRAEL model)
MODE

29
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-12) OPTION SETTING

�When pressing R-Room temp setting KEY and Vacation KEY simultaneously for 12 sec, DISPLAY will
convert to Option Setting MODE.

Press for 12 sec

1. For example, if you want to set option and SHIFT the standard temp of F-Room to -3℃, follow the irections
below.
This function is to change the standard temp and if the standard temp at present is at F-Room (MID -18 ℃),
it can be lowered by -3℃ via using options and the standard temp will be controlled at -21℃ That is, in the
case of changing temp option, although you set it at -18℃ on the display panel, the fridge will operate at -21
℃ internally. Therefore, when you set the standard temp at -3℃, temp will lowered by -3 ℃ additionally
compared to that set on the display panel while controlling.
1) Press F-Room temp setting key and Quick Freezing KEY simultaneously for more than 12 sec. as shown
in the picture.
- All DISPLAY will be OFF except for F/R-Room temp indicating DISPLAY.
2) After changing into Option Mode, DISPLAY will show "0" for R-Room and "0" for F-Room.
(When shipping of the products, there shall be "0" for R-Room and "0" for F-Room but for the purpose of
quality improvement while producing, the standard setting value can be changed.)
- If "0" for R-Room is indicated, temp option item in F-Room will be set and temp setting value of F-Room
at present will be shown in temp DISPLAY for F-Room.
3) After setting "0" in R-Room and selecting "6" as in the option table of F-Room below, the standard temp
of F-Room will be lowered by 3 degree Celsius. (Refer to the picture of temp change in F-room )
: If you wait for 20 sec. after the completion of adjusting, MICOM will store the set value in EEPROM and
restore to normal DISPLAY while canceling option setting mode.
4) Since option is already set in EEPROM while shipping, do not change it randomly except for the
special occasions and do not turn off power before restoring to normal display because option is
completed as long as it can restore to normal display after 20 sec.

note) Basically, when shipping of the products, data are all cleared in Option.
That is, the Set Values are all 0 .However, for the purpose of quality improvement while
producing, the part of set values is altered and manufactured.Therefore, make sure to check
quality information.

30
FUNCTIONS & HOW-TO-USE BY PRODUCTS
Example of application) In the case of decreasing the standard temp of Freezer by -3 ℃

Super Freeze S/W Freezer Fridge Vacation S/W

Freezer S/W Fridge S/W

Set Value Option Setting

Example of application) In the case of increasing the standard temp of Fridge by +1.5 ℃

Super Freeze S/W Freezer Fridge Vacation S/W

Freezer S/W Fridge S/W

Set Value Option Setting

31
FUNCTIONS & HOW-TO-USE BY PRODUCTS
10-13) OPTION TABLE

note) When using the temp set S/W in F-Room and Vacation S/W, other options except for the above
mentioned functions re ALREADY set.Those are the items related to the refrigerator control and
they will be omitted since it is not necessary for A/S. (Do not set other options except for those in
the above A/S MANUAL.

Table for changing temp in F-Room Table for changing temp in R-Room

SET ITEM F-ROOM TEMP SHIFT SET ITEM R-ROOM TEMP SHIFT
MODEL TD-PJT MODEL TD-PJT
LOCATION : R-ROOM 7-SEG LOCATION : R-ROOM 7-SEG
DISPLAY DISPLAY
0 1
SET VALUE SET VALUE SET VALUE SET VALUE
COMMON COMMON COMMON COMMON
F-ROOM 7-SEG F-ROOM 7-SEG F-ROOM 7-SEG F-ROOM 7-SEG
0 0 8 +0.5℃ 0 0 8 +0.5℃
1 -0.5℃ 9 +1.0℃ 1 -0.5℃ 9 +1.0℃
2 -1.0℃ 10 +1.5℃ 2 -1.0℃ 10 +1.5℃
3 -1.5℃ 11 +2.0℃ 3 -1.5℃ 11 +2.0℃
4 -2.0℃ 12 +2.5℃ 4 -2.0℃ 12 +2.5℃
5 -2.5℃ 13 +3.0℃ 5 -2.5℃ 13 +3.0℃
6 -3.0℃ 14 +3.5℃ 6 -3.0℃ 14 +3.5℃
7 -3.5℃ 15 +4.0℃ 7 -3.5℃ 15 +4.0℃

32
FUNCTIONS & HOW-TO-USE BY PRODUCTS

- PCB DIAGRAM

33