Field Service Ver. 2.0 Dec. 2008 3.

Periodical check

3.4.4 Replacing the transfer roller unit


A. Periodically replacing parts/cycle

bizhub C200
• Transfer roller unit: Every 120,000 prints

B. Removal procedure
1. Open the right door.
2. Unlock the lock levers [1] of the
[1] [2] [1]
transfer roller unit (at two places).
3. Holding onto the lock levers [1] (at
two places), remove the transfer
roller unit [2].

A02FF2C003DA

Maintenance
C. Reinstall procedure
1. Holding onto the lock levers [1] (at
[1] [2] [1]
two places), mount the new transfer
roller unit [2].
2. Lock the lock levers [1] (at two
places).
NOTE
• Make sure that the levers are locked
in position both at front and rear.

A02FF2C004DA

3. Close the right door.