DC operation
IEC 60 947, EN 60 947 Coupling relays have a low No auxiliary switch blocks can
(VDE 0660) power consumption, an be mounted onto size S00
The 3RT10 coupling relays for extended coil voltage toler- 3RT10 1. coupling relays; two
switching motors are tailored to ance and an integrated surge single-pole auxiliary switch
the special requirements of suppressor for damping open- blocks can be mounted onto
working with electronic con- ing surges (exceptions: 3RT10 size S0 3RT10 2. coupling
trols. 1.-1HB4. and 3RT10 1.-.MB4.- relays.
0KT0).
nsb0073
nsb0072
Surge Ratings Auxiliary contacts Screw connection Cage Clamp connection Weight
suppressor Utilization category approx.
AC-2 and AC-3 Ident. Design DT Order No. Price DT Order No. Price
Tu: up to 60 °C no.
Operat. Ratings of
current Ie three-phase
motors at
50 Hz and
at 400 V 400 V
Surge Ratings Auxiliary contacts Screw connection Cage Clamp connection Weight
suppressor Utilization category for coil terminals approx.
AC-2 and AC-3 Ident. Design DT Order No. Price DT Order No. Price
Tu: up to 60 °C no.
Operat. Ratings of
current Ie three-phase
motors at
50 Hz and
at 400 V 400 V
Contactor type 3RT10 1 3RT10 2, 3RT14 3RT13 1, 3RT13 2 ... 3RT13 4, 3RT16
3RT10 3, 3RT15 1 3RT15 2 and 3RT15 3
Rated control Control sup-
3RT10 4
supply voltage ply voltage
Us at 60 Hz Preferred type (applies only to 12-digit Order Nos.)
Rated control supply voltages (changes to 10th and 11th positions of the Order No.)
Sizes S00 to S3
AC operation 1)
Coils for 50 Hz (exception: size S00: 50 and 60 Hz 2)
AC 24 V B0 B0 B0 B0 B0 B0
AC 42 V D0 D0 D0 D0 – –
AC 48 V H0 H0 H0 H0 – –
AC 110 V F0 F0 F0 F0 F0 F0
AC 230 V P0 P0 P0 P0 P0 P0
AC 400 V V0 V0 V0 V0 V0 V0
Coils for 50 and 60 Hz 2)
AC 24 V B0 C2 C2 B0 C2 C2
AC 42 V D0 D2 D2 D0 D2 –
AC 48 V H0 H2 H2 H0 H2 –
AC 110 V F0 G2 G2 F0 G2 G2
AC 220 V N2 N2 N2 N2 N2 N2
AC 230 V P0 L2 L2 P0 L2 L2
For USA and Canada 3)
50 Hz 60 Hz
AC 110 V AC 120 V K6 K6 K6 K6 K6 K6
AC 220 V AC 240 V P6 P6 P6 P6 P6 P6
For Japan
50/60 Hz 4) 60 Hz 5)
AC 100 V AC 110 V G6 G6 G6 G6 G6 G6
AC 200 V AC 220 V N6 N6 N6 N6 N6 N6
AC 400 V AC 440 V R6 R6 R6 R6 R6 R6
DC operation 1)
DC 12 V A4 – – A4 – –
DC 24 V B4 B4 B4 B4 B4 –
DC 42 V D4 D4 D4 D4 D4 –
DC 48 V W4 W4 W4 W4 – –
DC 60 V E4 E4 E4 – – –
DC 110 V F4 F4 F4 F4 F4 –
DC 125 V G4 G4 G4 G4 G4 –
DC 220 V M4 M4 M4 M4 M4 –
DC 230 V P4 P4 P4 P4 – –
Sizes S6 to S12
AC/DC operation (40 ... 60 Hz, DC)
Conventional operating mechanism
Size S6 S10, S12 Size S6 S10, S12
Us min to Us max 6) Contactor type 3RT1. 5. -. A 3RT1.6/7. -.A Us min to Us max 6) Contactor type 3RT1.5.- .A 3RT1. 6/7.-. A
AC/DC 23 ... 26 V B3 B3 AC/DC 240 ... 277 V U3 U3
AC/DC 42 ... 48 V D3 D3 AC/DC 380 ... 420 V V3 V3
AC/DC 110 ... 127 V F3 F3 AC/DC 440 ... 480 V R3 R3
AC/DC 200 ... 220 V M3 M3 AC/DC 500 ... 550 V S3 S3
AC/DC 220 ... 240 V P3 P3 AC/DC 575 ... 600 V T3 T3
Solid-state operating mechanism
Size S6 S10, S12
Us min to Us max 6) Contactor type 3RT1. 5. -. N 3RT1.5. -.P/Q 3RT1.6/7. -.N 3RT1. 6/7.-. P/Q
AC/DC 21 ... 27.3 V B3 – B3 –
AC/DC 96 ... 127 V F3 F3 F3 F3 7)
AC/DC 200 ... 277 V P3 P3 P3 P3 7)
1) The SITOP power DC 24 V power supply unit 3) Coil voltage tolerance Sizes S0 ... S3:
with extended-range input (AC 93 ... 264 V; DC Size S00: at 50 Hz: 0.8 ... 1.1 x Us
30 ... 264 V) can be used for energizing the coil at 50 Hz: 0.85 ... 1.1 x Us at 60 Hz: 0.85 ... 1.1 x Us
for other coil voltages and coil voltage toleran- at 60 Hz: 0.8 ... 1.1 x Us 5) Coil voltage tolerance
ces for sizes S00 and S0 (see Part 14). Sizes S0 ... S3: at 60 Hz: 0.8 ... 1.1 x Us
2) Coil voltage tolerance at 50 Hz and 60 Hz: 0.8 ... 1.1 x Us 6) Coil voltage tolerance:
at 50 Hz: 0.8 ... 1.1 x Us 4) Coil voltage tolerance 0.8 x Us min ... 1.1 x Us max
at 60 Hz: 0.85 ... 1.1 x Us Size S00: 7) 3RT12 vacuum contactors available from March
at 50/60 Hz: 0.85 ... 1.1 x Us 2002.
Y 27/28
37/38
t 50 ms
g_nsb_xx_00453g
g_nsb_xx_00454n
The variant for size S00 contac- The time-delay block for size S0
"OFF-delay" with auxiliary tors is fitted onto the front of the to S3 contactors is plugged into
power supply designs, allows A1 B1 A2 K3
contactor (with the supply volt- coil terminals A1 and A2 on top 1
time-delayed functions up to age switched off) and then slid of each contactor; the time-
100 s (3 distinct delay ranges). A1 A2
NSB00454
into its latched position; at the delay relay is connected both 2
Contactors fitted with a time- same time, the time-delay relay electrically and mechanically
delay block close or open after N
is connected by means of plug- by means of pins.
a delay according to the set in contacts to coil terminals A1
time. A varistor is integrated in the
and A2 of the contactor. Any timer module for damping $L1
The ON-delay variant of the contactor coil terminals which K3 S1
g_nsb_xx_00455n
opening surges in the contactor
time-delay relay is connected in are not required are sealed off coil.
series with the contactor coil; by means of covers on the A1 B1 A2 K3
terminal A1 of this coil must not enclosure of the time-delay 1
A1 A2
NSB00455
4000 V
Capacitive input to various ana- Since the EMC interference
log and digital signals makes it suppression module achieves a
V significant reduction in radio-
necessary to suppress interfe-
rence in the load circuit. frequency components and the
voltage level in three phases,
the contact endurance is also
improved considerably. This
g nsb xx 00456h
NSB00457a
NSB00458a
ations within each perfor-
V
mance class, as smaller motors V
inherently have a higher induc-
tance, so that one solution for
all fixed-speed drives up to
5.5 kW is adequate.
930 V 950 V
400 V 400 V
500 ms t 500 ms t
g_nsb_xx_00457h g_nsb_xx_00458h
Two electrical variants are The advantages of the RC cir- The varistor circuit is able to
available: cuit lie mainly in the reduction in absorb high energy levels and
the rate of rise and in its RF is also suitable for frequencies
damping ability. The selected from 10 to 400 Hz (variable-
values ensure effective interfer- speed drives). There is no limit-
ence suppression over a wide ing below the knee-point volt-
range. age, however.
OFF-delay device
for size S00 to S3 contactors
AC and DC operation contactor does not open. The A contactor opens after a delay Operation
IEC 60 947, EN 60 947 3RT1 916 OFF-delay devices when the capacitors of the con- In the case of the versions for
are specifically designed for tactor coil, built into the OFF- rated control supply voltages of
For screwing and snapping operation with the 3RT contac- delay device, are switched in
onto 35 mm standard mounting 110 V and 230 V, either AC volt-
tors and 3RH contactor relays parallel. In the event of voltage age or DC voltage can be
rail. The OFF-delay devices of the SIRIUS series. failures, the capacitors are dis-
have screw connections. applied on the line side, where
charged via the coil and as the variant for 24 V is
thereby delay the opening of designed for DC operation only.
Principle of operation the contactor.
Application The OFF-delay device operates A DC-operated contactor is con-
The OFF-delay device pre- If the command devices are nected to the output in accor-
without external voltage on a
vents a contactor from drop- upstream of the OFF-delay dance with the input voltage that
capacitive basis, and can be device in the circuit, the OFF
ping out unintentionally when energized with either AC or DC is applied.
there is a short-time voltage dip delay takes effect with every
(24 V version for DC operation opening operation. If the open- The mean value of the OFF
or voltage failure. It supplies the only). Voltage matching, which delay is approximately 1.5 times
necessary power for a series- ing operation is downstream of
is only necessary with AC oper- the specified minimum time.
connected, DC-operated con- the OFF-delay device, an OFF
ation, is performed using a rec-
tactor during a voltage dip to delay only applies in the event
tifier bridge.
ensure that the of failure of the mains voltage.
Application Functions
DC operation Design Surge suppression Mounting
IEC 60 947 and EN 60 947 System-compatible operation The 3RH19 24-1GP11 interface The 3RH19 24-1GP11 interface
The interface is suitable for use with DC 24 V, coil voltage toler- has an integrated surge sup- is mounted directly on the con-
in any climate. It is safe from ance 17 V to 30 V. pressor (varistor) for the con- tactor coil.
touch to DIN VDE 0106 Part Low power consumption in con- tactor coil being switched.
100. The terminal designations formity with the technical data
conform to EN 50 005. of the electronic systems.
A light-emitting diode indicates
the circuit state.
U A1 A2
2
A1
2
A2 NSB00184
NSB00182
$ $
% %
Interface Interface
Contactor Contactor
NSB0787g nsb0271g
nsb0721g nsb0730g
nsb0722g
Nsb0554b
3RH19 11-1HA . . 3RH19 11-2HA . . 3RH19 21-1HA . . 3RH19 21-2HA . . 3RH19 11-1AA . . 3RH19 11-1LA . .
-1FA . . -2FA . .
For Rated operational Auxiliary contacts Screw connection Cage Clamp connection Weight
contactors current approx.
Ie /AC-15/AC-14 Ident. Design DT Order No. Price DT Order No. Price
NS2SYM02
NS2SYM01
NS2SYM05
NS2SYM04
no.
at
230 V
3RH19 21-1F . . . 3RH19 21-2F . . . 3RH19 21-1C . . . 3RH19 21-2C . . . 3RH19 21-1LA . . 3RH19 21-1MA ..
For Rated operational Auxiliary contacts Screw connection Cage Clamp connection Weight Pack.
contactors current approx.
Ie /AC-15/AC-14 Ident. Design DT Order No. Price DT Order No. Price
NS2SYM02
NS2SYM01
NS2SYM05
NS2SYM04
no.
at
230 V
Type A NO NC NO NC PG 101 1 unit PG 101 1 unit kg
Auxiliary switch blocks for snapping onto the front
acc. to EN 50 005
Sizes S0 to S12 1)
4-pole auxiliary switch blocks
3RT10 2, 6 40 4 – – – } 3RH19 21-1FA40 } 3RH19 21-2FA40 0.065 1 unit
3RT1. 3 to 31 3 1 – – } 3RH19 21-1FA31 } 3RH19 21-2FA31
3RT1. 7, 22 2 2 – – } 3RH19 21-1FA22 } 3RH19 21-2FA22
3RT11 04 – 4 – – } 3RH19 21-1FA04 } 3RH19 21-2FA04
22 U – – 2 2 } 3RH19 21-1FC22 A 3RH19 21-2FC22
Single-pole auxiliary switch blocks acc. to EN 50 005 and EN 50 012 (1 pack = 10 units)
3RT1. 2 to 6 – 1 – – – } 3RH19 21-1CA10 } 3RH19 21-2CA10 0.015 1 pack
3RT1. 7, – – 1 – – } 3RH19 21-1CA01 } 3RH19 21-2CA01
3RT11 – – – 1 – A 3RH19 21-1CD10 –
– – – – 1 A 3RH19 21-1CD01 –
2-pole auxiliary switch blocks with cable entry from one side
Cable entry from above
3RT10 2, 6 – 1 1 – – } 3RH19 21-1LA11 – 0.065 1 unit
3RT1. 3 to – 2 – – – } 3RH19 21-1LA20 –
3RT1. 7, – – 2 – – } 3RH19 21-1LA02 –
3RT11
Cable entry from below
6 – 1 1 – – } 3RH19 21-1MA11 – 0.065 1 unit
– 2 – – – } 3RH19 21-1MA20 –
– – 2 – – } 3RH19 21-1MA02 –
NS2SYM02
230 V
For int. circuit diagrams, see page 3/148. 1) Cannot be used for 3RT11 2 weld-free contac-
For position of terminals, see page 3/153. tors, size S0 (see Part 5).
nsb0551g
3RH19 11-1NF . . 3RH19 11-2NF . . 3RH19 21-1FE22 3RH19 21-2FE22 3RH19 21-2DE11
-2JE11
For Design Contacts Screw connection Cage Clamp connection Weight
contactors approx.
Design DT Order No. Price DT Order No. Price
NS2SYM01
NS2SYM02
Nsk-sym2
For int. circuit diagrams, see page 3/149. 1) Cannot be used for 3RT11 2 weld-free contac-
For position of terminals, see page 3/153. tors, size S0 (see Part 5).
For int. circuit diagrams, see page 3/149. 1) The terminals for the rated control supply 3) The AC voltages are valid for 50 Hz and 60 Hz.
For position of terminals, see page 3/156. voltage are connected to the contactor by the 4) Cannot be fitted onto coupling relays.
integrated spring contacts of the solid-state 5) Position of the output contacts not defined in
time-delay auxiliary switch above it when this the as-delivered state (bistable relay). Applying
switch is mounted. the control voltage once results in the contacts
2) Terminals A1 and A2 for the rated control sup- switching to the correct position.
ply voltage of the solid-state time-delay auxi-
liary switch must be connected to the associa-
ted contactor by means of connecting leads.
3RT19 26-2C . . . 3RT10 2, AC/DC 24 V ... 66 V 0.05 ... 1 C 3RT19 26-2CG11 0.035 1
3RT10 3, 0.5 ... 10 A 3RT19 26-2CG21
3RT10 4 2), 5 ... 100 C 3RT19 26-2CG31
3RT13 2),
3RT15 AC/DC 90 V ... 240 V 0.05 ... 1 } 3RT19 26-2CH11 0.035 1
0.5 ... 10 } 3RT19 26-2CH21
5 ... 100 } 3RT19 26-2CH31
nsb0089
OFF-delay with auxiliary voltage (varistor integrated)
3RT19 26-2D . . . 3RT10 2, AC/DC 24 V ... 66 V 0.05 ... 1 C 3RT19 26-2DG11 0.037 1
3RT10 3, 0.5 ... 10 } 3RT19 26-2DG21
3RT10 4 2), 5 ... 100 C 3RT19 26-2DG31
3RT13 2),
3RT15 AC/DC 90 V ... 240 V 0.05 ... 1 C 3RT19 26-2DH11 0.037 1
nsb0090 0.5 ... 10 A 3RT19 26-2DH21
5 ... 100 C 3RT19 26-2DH31
OFF-delay device
3RT19 16-2B .01 3RT1 . 1, AC/DC 110 V } 3RT19 16-2BK01 1
3RT1 . 2,
3RH1 . . . -1BF40
3RT1 . 1, AC/DC 220/230 V } 3RT19 16-2BL01 1
3RT1 . 2,
3RH1 . . . -1BM40
3RT1 . 1 DC 24 V } 3RT19 16-2BE01 1
to 3RT1 . 4,
3RH1 . . . -1BB40
Nsb0566g
1) Can be used for AC operation at 50/60 Hz. 2) For packs of 10 units, the Order No. must be
Further voltages on request. supplemented with "–Z" and the order code
"X90".
5 units 2)
3RT19 36-1C . 00 3RT1 . 3, RC element AC 24 V ... 48 V } 3RT19 36-1CB00 0.01
3RT1 . 4 DC 24 V ... 70 V
AC 48 V ... 127 V } 3RT19 36-1CC00
DC 70 V ... 150 V
AC 127 V ... 240 V } 3RT19 36-1CD00
nsb0094 DC 150 V ... 250 V
AC 240 V ... 400 V } 3RT19 36-1CE00
AC 400 V ... 600 V A 3RT19 36-1CF00
For Design Rated control supply Power consump- Surge suppressor Weight Price
contactors voltage Us 1) tion of LED at Us approx.
DT Order No. 2) Price per
pack of
Type mW PG 101 1 unit kg 10 units 2)
Surge suppressors with LED (also for Cage Clamp connection)
Size S00
For plugging onto the front of contactors with or without an auxiliary switch block
3RT19 16-1L . 00 3RT1, Varistor AC 24 V ... 48 V 10 ... 120 } 3RT19 16-1JJ00 0.01
3RH1 . DC 12 V ... 24 V
AC 48 V ... 127 V 20 ... 470 } 3RT19 16-1JK00
DC 24 V ... 70 V
AC 127 V ... 240 V 50 ... 700 } 3RT19 16-1JL00
DC 70 V ... 150 V
DC 150 V ... 250 V 160 ... 950 } 3RT19 16-1JP00
1) Can be used for AC operation at 50/60 Hz. 2) For packs of 10 or 5 units, the Order No. must
Further voltages on request. be supplemented with "–Z" and the order code
"X90".
Type PG 101 kg
EMC interference suppression module, 3-phase; ≤ 5.5 kW
Size S00 (for contactors with AC or DC operation)
3RT19 16-1PA . See also description on page 3/39
1 unit
3RT10 1 RC element up to 400 V } 3RT19 16-1PA1 1 unit
(3 x 220 Ω/0.22 µF) 575 V A 3RT19 16-1PA2
690 V A 3RT19 16-1PA3
nsb0095
Main conducting path surge suppression module for 3RT12 vacuum contactors
Sizes S10 and S12 1 unit
3RT12 Rated operational voltage Ue ≥ AC 500 V ... ≤ AC 690 V B 3RT19 66-1PV3 0.18 1 unit
Rated operational voltage Ue ≤ AC 1 000 V B 3RT19 66-1PV4 0.36
For damping overvoltages and protecting the motor windings
against multiple reignition when switching off three-phase
motors.
For connection on the contactor feeder side (2-T1/4-T2/6-T3).
For separate installation.
Additional load module
Size S00 (also for Cage Clamp connection)
For plugging onto the front of contactors
3RT19 16-1GA00 with or without an auxiliary switch block
1 unit 1)
3RT1 . 1, For increasing the permissible residual current and for limiting } 3RT19 16-1GA00 1 unit
3RH1 . the residual voltage. Ensures safe opening of contactors with
direct control via AC 230 V semiconductor outputs of SIMATIC
controls. Also performs the function of a surge damping circuit.
Rated voltage: AC 50/60 Hz, 180 V ... 255 V.
Coil voltage tolerance: 0.8 ... 1.1 x Us
nsb0096 Size S6
For contactors with
conventional operat. mechanism 3RT1.5.-.A...
solid-state operat. mechanism 3RT1.5.-.N...
For separate installation.
1 unit
3RT1 . 5 For control voltage Us (40 Hz ... 60 Hz) ≤ AC 277 V } 3RT19 56-1GD00 0.03 1 unit
> AC 277 V B 3RT19 56-1GE00
Power consumption approx. 4.3 VA.
For reducing the interfering influence of the line capacitances
of long control leads (contactor does not switch off after OFF
command) and extending the critical line length in AC lead
lengths to approx. 1000 m.
(Not necessary for contactors with solid-state operating
mechanism and operation via PLC/AS-Interface)
Control kit
Size S00
3RT1 . 1, For manual operation of the contactor contacts for See Part 1, SIMATIC ET 200S
3RH1 . start-up and service Distributed I/O Devices,
motor starters,
3RK1 903-0CA00
nsa0207g
Type PG 101 kg
Interface for control by PLC
Sizes S0 to S3
For mounting onto the coil terminals of the contactors
1 unit
3RH19 24-1GP11 3RT1 . 2, Coil voltage tolerance DC 17 V ... 30 V } 3RH19 24-1GP11 1 unit
3RT1 . 3, Power consumption: 0.5 W at DC 24 V
3RT1 . 4 Permissible residual current of electronics (with 0 signal):
2.5 mA
Rated operational current Ie:
AC-15/AC-14 at 230 V: 3 A, DC-13 at 230 V: 0.1 A
With LED for indicating circuit state.
nsb0097 With integrated varistor for damping opening surges.
LED module for indicating contactor operation (also for Cage Clamp connection)
3RT19 26-1QT00 Sizes S0 to S3
mounted on contactor 1 pack
3RT1 . 2, For snapping into the location hole of an identification A 3RT19 26-1QT00 1 pack
3RT1 . 3, label on the front of a contactor.
3RT1 . 4 The LED module is connected to coil terminals A1 and A2 of
the contactor and indicates its energized state. Yellow LED.
Rated voltage: AC/DC 24 V ... 240 V, polarized.
(1 pack = 5 units)
nsb0098
nsb0099
Solder pin adapter for contactors with mounted 4-pole auxiliary switch block
Size S00
3RT1 . 1 Installation kit for soldering contactors with an auxiliary switch A 3RT19 16-4KA2 1
3RH11 block onto a printed circuit board
1 pack contains 16 parts for 4 contactors and 4 auxiliary switch
blocks.
nsb0101
nsb0726g
nsb0727g nsb0616g
nsb0728g
Size For Max. rated operational currents Max. conductor DT Order No. Price Weight Pack.
contactors Ie/AC-1 (at 60 °C) of contactors cross-sections approx.
Type A mm2 PG 101 1 unit kg Units
Links for paralleling
3-pole, with terminal 1)2)
S00 3RT10 1 . 50 25 } 3RT19 16-4BB31 1
1) The links for paralleling can be reduced by 2) Sizes S00 to S2: The links for paralleling are insulated.
one pole. Size S3: A cover plate is supplied separately packed for shock-hazard protection.
(Can only be used when the box terminal is removed.)
Sizes S6 to S12: The 3RT19 56-4EA1 (with S6) or 3RT19 66-EEA1 (with S10 and S12)
cover can be used for shock-hazard protection.
nsb0107
For identification labels, see Part 17. 1) As standard to 3RT10 54-1 contactor (55 kW) 2) Refer to the note on page 3/103, conductor
cross-sections.
Overview
The new SIRIUS generation is a
complete, modular system
family, logically designed right
down to the last detail, from the
basic units to the accessories.
12
5
7 13
8 2
14
10
11
15
16
g_nsb_xx_00066g
centrally positioned release diode) can be plugged onto all Ident. No. 80E, Ident. No. 40, 31,
lever for disassembly. contactor relays from the front 71E, 62E, 53E, 44E 22, 20, 11, 02
The contactor relays with 4 con- for damping opening surges in
the coil. The plug-in direction is g_nsb_de_00067b
tacts in accordance with
EN 50 011, with the identifica- determined by a coding
device.
tion number 40E, can be exten-
ded with 80E to 44E auxiliary
switch blocks to obtain contac- Note
tor relays with 8 contacts in The opening times of the NO
accordance with EN 50 011. contacts and the closing times
The identification numbers 80E of the NC contacts increase if
to 44E on the auxiliary switch the contactor coils are protec-
blocks apply to the complete ted against voltage peaks (sup-
contactors (see illustration alo- pression diode 6 to 10 times,
ngside). diode assemblies 2 to 6 times,
varistor +2 ms to 5 ms).
Application
AC and DC operation The terminal designations com- The number of auxiliary con- from the front for damping
IEC 60 947, EN 60 947 ply with EN 50 011. tacts can be extended by opening surges.
(VDE 0660) The contactor coil and the coil means of auxiliary switch The contactor relay can also
of the release solenoid are both blocks (up to 4 poles). be switched on and released
designed for continuous duty. RC elements, varistors, diodes manually.
or diode assemblies can be (For minimum actuating times,
plugged onto both coils see page 3/138)
Application
AC and DC operation Design Terminal designations accor- Surge suppression
IEC 60 947 and EN 60 947 The 3TH43 contactor relays are ding to EN 50 011 The 3TH43 contactors can be
(VDE 0660) suitable for use in any climate. In terms of their terminal desig- equipped with RC elements,
They are safe from touch to nations, identification numbers varistors, diodes or diode
DIN VDE 0106 Part 100. and identification letters, the assemblies (combination of a
3TH43 contactor relays con- diode and a Zener diode) for
Contact reliability form to the standard EN 50 011 damping opening surges. The
for "Specific contactor relays". surge suppressors can be
High contact stability at mounted directly on the coil
low voltages and currents (see accessories).
thanks to the use of moving
double-break contacts, suitable
for electronic circuits with cur- Note
rents ≥ 1 mA at voltages of 17 V The opening times of the NO
or higher. contacts and the closing times
of the NC contacts increase if
Make-before-break the contactor coils are protec-
contacting ted against voltage peaks (sup-
pression diode 6 to 10 times,
The 3TH43 contactor relays are diode assemblies 2 to 6 times,
available in variants with make- varistor +2 ms to 5 ms).
before-break contacting (make-
before-break between 1 NO
and 1 NC).
The make-before-break time is
approximately 1 ms. This is not
sufficient to cause another con-
tactor to close. If the make-
before-break current paths are
connected in series, a fleeting
contact element is created; the
wiping time is approximately
1 ms.
NSB0643g
nsb0267g NSB0600g
nsb0268g
Rated operational Contacts Rated control Screw connection Cage Clamp connection Weight Pack.
current supply voltage approx.
Us
Ie /AC-15/AC-14 Ident. no. Design DT Order No. Price DT Order No. Price
at 230 V
Rated operational current Contacts Rated control DT Order No. Price Weight
Ie /AC-15/AC-14 supply voltage approx.
at Ident. no. Design
230 V acc. to
EN 50 011
A NO NC PG 101 1 unit kg
With screw connections · for screwing and snapping onto 35 mm standard mounting rail
3RH14 22-1BB40 AC operation AC 50/60 Hz 1)
6 40 E 4 – 24 V } 3RH14 40-1AB00 0.38
42 V B 3RH14 40-1AD00
110 V B 3RH14 40-1AF00
230 V A 3RH14 40-1AP00
Rated control supply voltage (change the 10th and 11th positions of the Order No.) only for 3RH11 contactor relays
AC operation DC operation
Coils for AC 50 and 60 Hz No additional charge is made for all voltages
Rated control Control supply Rated control
supply voltage Us voltage at supply voltage Us
AC V AC V Supple- DC V Supple-
50/60 Hz 1) 60 Hz ment ment
24 B0 12 A4
42 D0 24 B4
48 H0 42 D4
110 F0 48 W4
220 N2 60 E4
230 P0 110 F4
400 V0 125 G4
220 M4
230 P4
For Japan 2)
100 110 G6
200 220 N6
400 440 R6
For USA and Canada 3)
AC V AC V
50 Hz 60 Hz
110 120 K6
220 240 P6
Further voltages on request. For accessories for 3RH14, see 3/41 and 3/58. 1) Coil voltage tolerance
For technical data, see 3/136. at 50 Hz: 0.8 ... 1.1 x Us
For multi-unit, recyclable packing, at 60 Hz: 0.85 ... 1.1 x Us
For overview, see 3/53.
see Part 17. 2) Coil voltage tolerance
For position of terminals, see 3/158.
For dimension drawings, see 3/226. at 50/60 Hz: 0.85 ... 1.1 x Us
at 60 Hz: 0.8 ... 1.1 x Us
3) Coil voltage tolerance
at 50 Hz: 0.85 ... 1.1 x Us
at 60 Hz: 0.8 ... 1.1 x Us
NSB0788g
nsb0105g
For contactor relays Rated operational current Contacts Screw connection Cage Clamp connection Weight
Ie/AC-15/AC-14 approx.
Type at Ident. no. Design DT Order No. Price DT Order No. Price
230 V
For further accessories for contactor relays size S00, see accessories, 3/41,
accessories for 3RT10 1 . contactors for switching motors, size S00.
A A A A NO NC NO NC PG 101 1 unit kg
With screw connections · for screwing and snapping onto 35 mm standard mounting rail
3TH43 ..-0A AC operation, rated control supply voltage Us: AC 50 Hz 230/220 V 1)
10 6 4 2 100 E 10 – – – } 3TH43 10-0AP0 0.48
91 E 9 1 – – } 3TH43 91-0AP0
82 E 8 2 – – } 3TH43 82-0AP0
73 E 7 3 – – } 3TH43 73-0AP0
73 E; U 6 2 1 1 } 3TH43 46-0AP0
3TH43 ..-0B DC operation · DC solenoid system, rated control supply voltage Us: DC 24 V
10 6 4 2 100 E 10 – – – } 3TH43 10-0BB4 0.69
91 E 9 1 – – } 3TH43 91-0BB4
82 E 8 2 – – } 3TH43 82-0BB4
73 E 7 3 – – } 3TH43 73-0BB4
73 E; U 6 2 1 1 } 3TH43 46-0BB4
Rated control supply voltage (change the 10th and 11th positions of the Order No.) only for 3TH43 contactor relays
AC operation DC operation
Coils for AC 50 Hz Coils for AC 50 and 60 Hz Additional charge
Rated control Control supply Rated control Rated control No additional charge.
supply voltage Us voltage at supply voltage Us supply voltage Us
Additional charges are app-
lied for devices with different
AC V AC V Supple- AC V Supple- DC V Supple- coil voltages (not shown high-
50 Hz 60 Hz ment 50/60 Hz ment ment lighted in colour).
24 29 B0 24 C2 12 A4 AC operation:
32 38 C0 42 D2 24 B4 DC operation:
36 42 G0 110 G2 30 C4
42 50 D0 115 J2 36 V4
48 58 H0 120 K2 42 D4
60 72 E0 208 M2 48 W4
110 132 F0 220 N2 60 E4
125/127 150/152 L0 230 L2 110 F4
230/220 276 P01) 240 P2 125 G4
240 288 U0 440 R2 180 K4
575 S2
400/380 480/460 V01) 220 M4
415 500 R0 230 P4
500 600 S0 240 Q4
For Japan
100 100-110 G6 2)
200 200-220 N6 2)
400 400-440 R6 2)
For USA and Canada
110 120 K6 2)
220 240 P6 2)
For multi-unit, recyclable packing, 1) Coil voltage tolerance at 220 V or 380 V: Spare parts
see Part 17. 0.85 ... 1.1 x Us; Coils: as for 3TF40, see Catalog NS E.
lower tolerance range limit acc. to IEC 60 947. Contacts: the contacts cannot be replaced on
For accessories for 3TH43, see 3/60. 2) Coil voltage tolerance at 60 Hz: 0.85 ... 1.1 x Us 3TH43 contactor relays.
For technical data, see 3/139.
For overview, see 3/55.
For position of terminals, see 3/159.
For dimension drawings, see 3/227.
Cover
for ON-OFF indicator – B 3TX4 210-0P 0.005 100
For Rated control Time setting DT Order No. Price Weight Pack.
contactor supply voltage range approx.
Us (minimum times)
Type AC 50/60 Hz PG 101 1 unit kg Units
ON-delay device
3TX4 180-0A 3TH43 NTC thermistor AC 230 ... 220 V 100 ms C 3TX4 180-0A 0.01 10
Time tolerance
+100%, –50%
For typical circuit diagrams
see page 3/159
Nsb0293g
1) The opening times of the NO contacts and the peaks (suppression diode 6 up to 10 times, 2) Includes the peak value of the ripple voltage on
closing times of the NC contacts increase if the diode assemblies 2 to 6 times, varistor +2 to the DC side.
contactor coils are protected against voltage 5 ms).
Application Functions
DC operation The 3RH11 coupling relays for No auxiliary switch blocks can Coupling relays have a low
IEC 60 947 and EN 60 947 switching auxiliary circuits are be snapped onto 3RH11 power consumption, an
(VDE 0660) tailored to the special require- coupling relays. extended coil voltage toler-
ments of working with elec- ance and an integrated surge
tronic controls. suppressor for damping open-
ing surges
(exceptions: 3RH11 ..-.HB40
and 3RH11 ..-.MB4.-0KT0).
Surge Rated operational current Contacts Screw connection Cage Clamp connection Weight
suppressor Ie/AC-15/AC-14 approx.