Specializing in Oil Filtration

for the Power Industry


Locations

Almere, The Netherlands

Calgary, Canada
Specializing in Oil Filtration Cedex, France
for the Power Industry
Beijing, China

Evansville, Wyomig

Load Tap Changer Farmington, New Mexico

Filtration
Greensboro, North Carolina

Houston, Texas
Peco Facet Power Distribution
Kempen, Germany Filtration Products
• Reduce Operating Kuala Lumpur, Malaysia
and Maintenance Cost Call Us
La Coruna, Spain
Facet Filtration maintains
insulating oil cleaner than new
For
oil cleanliness levels by removing
metallic, particulate, and water
Manama, Bahrain
Clear
contamination to aerospace
specifications. Super clean oil
Mid Glamorgan, United Kingdom
Solutions
eliminates the precursors to oil Porto Alegre, Brazil
oxidation that leads to the formation
of sludge and coking in tap Typical view of LTC Tank Typical view of LTC Tank
Queretaro, Mexico
changers. Facet Filtration eliminates with filtration without filtration
insulating oil replacement cost and 12 months after 12000 operations 12 months after 12000 operations
indefinitely extends costly routine Sacramento, California
load tap changer maintenance.
Stilwell, Oklahoma

• Extend Equipment Life Torino, Italy


Facet Filtration increases the Tulsa, Oklahoma
effectiveness of insulating oil by
maintaining high oil dielectric
strength and interfacial tension and Vernal, Utah
low moisture and acid levels in oil.
Super clean oil prevents LTC contact Weifang, China
over-arcing which minimizes contact
scorching, reduces contact wear,
and extends internal component
and LTC contact life.

• Increase Equipment Life


and Reliability
Installing Facet Filtration can
eliminate the possibility of 9910 East 56th Street North
premature Load Tap Changer Tulsa, OK 74117
failure. Our filtration equipment
turns costly maintenance events
into simple inspections. Eliminate
unexpected outages and increase LTC with filtration LTC without filtration 800 • 223 • 9910
your equipment’s performance and No signs of contact degradation Heavily coked with signs of 918 • 272 • 8700
reliability with Facet Filtration. excessive arcing

www.facetinternational.com
Alternate Filter Selection Available for All Industry Standard Vessels info@facetusa.com
Specializing in Oil Filtration
for the Power Industry

Load Tap Changer


Filtration
• Reduce Operating
and Maintenance Cost
Facet Filtration maintains
insulating oil cleaner than new
oil cleanliness levels by removing

Insulating Oil Filters


metallic, particulate, and water
contamination to aerospace
specifications. Super clean oil

for Utilities Market UA-829-1*


eliminates the precursors to oil
oxidation that leads to the formation
of sludge and coking in tap Typical view of LTC Tank Typical view of LTC Tank
changers. Facet Filtration eliminates with filtration without filtration
Benefits insulating oil replacement cost and 12 months after 12000 operations 12 months after 12000 operations
• Absorbs highly emulsified water and dissolved water indefinitely extends costly routine
load tap changer maintenance.
• Retains larger amounts of water than our competitor
• High efficiency for ultra-fine carbon removal
• Extend Equipment Life
• High collapse rating of cartridges
Facet Filtration increases the
effectiveness of insulating oil by
Materials maintaining high oil dielectric
strength and interfacial tension and
• Metal components treated to protect against corrosion low moisture and acid levels in oil.
• Super-absorbent polymers which chemically lock in water Super clean oil prevents LTC contact
over-arcing which minimizes contact
• Glass cellulose pleated section for ultra-fine solids removal scorching, reduces contact wear,
and extends internal component
• Buna-N gaskets and LTC contact life.

Standard Design Features • Increase Equipment Life


• 250o F Maximum operating temperature and Reliability
• 75 psi Minimum collapse pressure UA-815-1* UA-822-1* Installing Facet Filtration can
• Media migration barrier eliminate the possibility of
premature Load Tap Changer
• Outside to in flow direction failure. Our filtration equipment
turns costly maintenance events
into simple inspections. Eliminate
Applications Single piece construction to replace unexpected outages and increase LTC with filtration LTC without filtration
* your equipment’s performance and No signs of contact degradation
• Circuit Breaker Oil • Tap Changer Oil Cuno/ErtelAlsop 2, 3 & 4 high stacked Heavily coked with signs of
reliability with Facet Filtration. excessive arcing
• Hydraulic Oil • Transformer Oil

partially open
disc type cartridges
• Silicone Dielectric Oil • Turbine Oil
• Switchgear Oil
Alternate Filter Selection Available for All Industry Standard Vessels
Specializing in Oil Filtration
for the Power Industry

Load Tap Changer


Filtration
• Reduce Operating
and Maintenance Cost
Facet Filtration maintains
insulating oil cleaner than new
oil cleanliness levels by removing

Insulating Oil Filters


metallic, particulate, and water
contamination to aerospace
specifications. Super clean oil

for Utilities Market UA-829-1*


eliminates the precursors to oil
oxidation that leads to the formation
of sludge and coking in tap Typical view of LTC Tank Typical view of LTC Tank
changers. Facet Filtration eliminates with filtration without filtration
Benefits insulating oil replacement cost and 12 months after 12000 operations 12 months after 12000 operations
• Absorbs highly emulsified water and dissolved water indefinitely extends costly routine
load tap changer maintenance.
• Retains larger amounts of water than our competitor
• High efficiency for ultra-fine carbon removal
• Extend Equipment Life
• High collapse rating of cartridges
Facet Filtration increases the
effectiveness of insulating oil by
Materials maintaining high oil dielectric
strength and interfacial tension and
• Metal components treated to protect against corrosion low moisture and acid levels in oil.
• Super-absorbent polymers which chemically lock in water Super clean oil prevents LTC contact
over-arcing which minimizes contact
• Glass cellulose pleated section for ultra-fine solids removal scorching, reduces contact wear,
and extends internal component
• Buna-N gaskets and LTC contact life.

Standard Design Features • Increase Equipment Life


• 250o F Maximum operating temperature and Reliability
• 75 psi Minimum collapse pressure UA-815-1* UA-822-1* Installing Facet Filtration can
• Media migration barrier eliminate the possibility of
premature Load Tap Changer
• Outside to in flow direction failure. Our filtration equipment
turns costly maintenance events
into simple inspections. Eliminate
Applications Single piece construction to replace unexpected outages and increase LTC with filtration LTC without filtration
* your equipment’s performance and No signs of contact degradation
• Circuit Breaker Oil • Tap Changer Oil Cuno/ErtelAlsop 2, 3 & 4 high stacked Heavily coked with signs of
reliability with Facet Filtration. excessive arcing
• Hydraulic Oil • Transformer Oil

partially open
disc type cartridges
• Silicone Dielectric Oil • Turbine Oil
• Switchgear Oil
Alternate Filter Selection Available for All Industry Standard Vessels
Tap Changer Filtration Systems Depth-Clear SA & U Series
U Series Modules provide reliable particle retention and

Specializing in Oil Filtration


long on-stream life cycles

for the Power Industry


Features & Benefits NA300KSA05 C9-04
Benefits
• Extends maintenance and inspection intervals • The proprietary
formulation process
• Eliminates coking and extends contact life used to produce the
SA Series results in
• Extends fluid life and maintains oil at aerospace depth media with
cleanliness levels exceptionally high
• Removes water and particulate matter moisture retention
properties
• NEMA 3R enclosure powder baked ANSI 61 Gray
with spill containment reservoir • Filter modules are easy
to handle and install
allowing for quick and NA600KSA05 C9-04
• Automatic high pressure, (plugged filter) shutdown
system and low pressure (loss of flow) shutdown easy change-outs
system with alarm • Very high surface area per module results in small
• Spill containment with oil spill shutdown system space requirements for filter housings
(patent # 5,691,706) • Filter modules are environmentally safe
• 3 GPM mechanical sealed positive displacement pump. • All SA Series modules are packaged with a desiccant
• Wired 110 volt, 1 phase with all electrical components to prevent absorption of moisture prior to use
assembled in a separate NEMA 4 enclosure
FLT105-B1
• Control circuit complete requiring only power and
alarm connections
Applications
• Transformer Oils • Lubrication Oils • Machine Oils
• Dielectric Oils • Turbine Oils • Tool Oil
• Hydraulic Oils

Insulating Oil Filters Features & Benefits

for Utilities Market UA-829-1*


• Extends maintenance and inspection intervals
• Eliminates coking and extends contact life Faci-Dry Filter Series
• Extends fluid life and maintains oil at aerospace Specifically designed to remove dissolved water and
Benefits cleanliness levels
particulate contamination from transformer oil
• Absorbs highly emulsified water and dissolved water • Removes water and particulate matter
• Retains larger amounts of water than our competitor
• NEMA 3R enclosure powder baked
Benefits
• High efficiency for ultra-fine carbon removal ANSI 61 Gray with spill containment reservoir • Removes dissolved water from insulating oil
to less than 5 PPM in a single pass
• High collapse rating of cartridges • Automatic high pressure, (plugged filter)
shutdown system and low pressure (loss of flow) • Single element will hold over 1900 ML
shutdown system with alarm or over 1 gallon of water
Materials • 1/2 Micron double pleated media provides
• Spill containment with oil spill shutdown system
• Metal components treated to protect against corrosion (patent # 5,691,706) particulate removal down to (1) Micron
• Super-absorbent polymers which chemically lock in water • Total containment holding capacity
• 3 GPM mechanical sealed positive displacement pump
• Glass cellulose pleated section for ultra-fine solids removal up to 1/3 pound
• Wired 110 volt, 1 phase with all electrical components
• Buna-N gaskets • Single element capable of
assembled in a separate NEMA 4 enclosure cleaning over 6000 gallons
• Control circuit complete requiring of insulating oil
Standard Design Features only power and alarm connections • Removes moisture
• 250o F Maximum operating temperature • Multifunctional timer, programmable from 1 hr. to 24 hrs. from transformer oil
to accommodate individual LTC needs
FLT105-C1 without heat or
• 75 psi Minimum collapse pressure UA-815-1* UA-822-1* vacuum system
• Media migration barrier • External Mount Package with:
0-100 glycerin filled pressure gauge
• Outside to in flow direction
Elapse hour counter to register run time Applications
External wiring lamp to indicate • Transformers
Applications * Single piece construction to replace high pressure shutdown • Oil Circuit Breakers
• Circuit Breaker Oil • Tap Changer Oil Cuno/ErtelAlsop 2, 3 & 4 high stacked FD-718-05 /P3
External warning lamp to indicate • Load Tap Changers FD-1107
• Hydraulic Oil • Transformer Oil disc type cartridges low pressure shutdown
• Silicone Dielectric Oil • Turbine Oil • Voltage Regulators
• Switchgear Oil • Insulating Oil storage tanks
Tap Changer Filtration Systems Depth-Clear SA & U Series
U Series Modules provide reliable particle retention and

Specializing in Oil Filtration


long on-stream life cycles

for the Power Industry


Features & Benefits NA300KSA05 C9-04
Benefits
• Extends maintenance and inspection intervals • The proprietary
formulation process
• Eliminates coking and extends contact life used to produce the
SA Series results in
• Extends fluid life and maintains oil at aerospace depth media with
cleanliness levels exceptionally high
• Removes water and particulate matter moisture retention
properties
• NEMA 3R enclosure powder baked ANSI 61 Gray
with spill containment reservoir • Filter modules are easy
to handle and install
allowing for quick and NA600KSA05 C9-04
• Automatic high pressure, (plugged filter) shutdown
system and low pressure (loss of flow) shutdown easy change-outs
system with alarm • Very high surface area per module results in small
• Spill containment with oil spill shutdown system space requirements for filter housings
(patent # 5,691,706) • Filter modules are environmentally safe
• 3 GPM mechanical sealed positive displacement pump. • All SA Series modules are packaged with a desiccant
• Wired 110 volt, 1 phase with all electrical components to prevent absorption of moisture prior to use
assembled in a separate NEMA 4 enclosure
FLT105-B1
• Control circuit complete requiring only power and
alarm connections
Applications
• Transformer Oils • Lubrication Oils • Machine Oils
• Dielectric Oils • Turbine Oils • Tool Oil
• Hydraulic Oils

Insulating Oil Filters Features & Benefits

for Utilities Market UA-829-1*


• Extends maintenance and inspection intervals
• Eliminates coking and extends contact life Faci-Dry Filter Series
• Extends fluid life and maintains oil at aerospace Specifically designed to remove dissolved water and
Benefits cleanliness levels
particulate contamination from transformer oil
• Absorbs highly emulsified water and dissolved water • Removes water and particulate matter
• Retains larger amounts of water than our competitor
• NEMA 3R enclosure powder baked
Benefits
• High efficiency for ultra-fine carbon removal ANSI 61 Gray with spill containment reservoir • Removes dissolved water from insulating oil
to less than 5 PPM in a single pass
• High collapse rating of cartridges • Automatic high pressure, (plugged filter)
shutdown system and low pressure (loss of flow) • Single element will hold over 1900 ML
shutdown system with alarm or over 1 gallon of water
Materials • 1/2 Micron double pleated media provides
• Spill containment with oil spill shutdown system
• Metal components treated to protect against corrosion (patent # 5,691,706) particulate removal down to (1) Micron
• Super-absorbent polymers which chemically lock in water • Total containment holding capacity
• 3 GPM mechanical sealed positive displacement pump
• Glass cellulose pleated section for ultra-fine solids removal up to 1/3 pound
• Wired 110 volt, 1 phase with all electrical components
• Buna-N gaskets • Single element capable of
assembled in a separate NEMA 4 enclosure cleaning over 6000 gallons
• Control circuit complete requiring of insulating oil
Standard Design Features only power and alarm connections • Removes moisture
• 250o F Maximum operating temperature • Multifunctional timer, programmable from 1 hr. to 24 hrs. from transformer oil
to accommodate individual LTC needs
FLT105-C1 without heat or
• 75 psi Minimum collapse pressure UA-815-1* UA-822-1* vacuum system
• Media migration barrier • External Mount Package with:
0-100 glycerin filled pressure gauge
• Outside to in flow direction
Elapse hour counter to register run time Applications
External wiring lamp to indicate • Transformers
Applications * Single piece construction to replace high pressure shutdown • Oil Circuit Breakers
• Circuit Breaker Oil • Tap Changer Oil Cuno/ErtelAlsop 2, 3 & 4 high stacked FD-718-05 /P3
External warning lamp to indicate • Load Tap Changers FD-1107
• Hydraulic Oil • Transformer Oil disc type cartridges low pressure shutdown
• Silicone Dielectric Oil • Turbine Oil • Voltage Regulators
• Switchgear Oil • Insulating Oil storage tanks
Specializing in Oil Filtration
for the Power Industry
Locations

Almere, The Netherlands

Calgary, Canada
Specializing in Oil Filtration Cedex, France
for the Power Industry
Beijing, China

Evansville, Wyomig

Load Tap Changer Farmington, New Mexico

Filtration
Greensboro, North Carolina

Houston, Texas
Peco Facet Power Distribution
Kempen, Germany Filtration Products
• Reduce Operating Kuala Lumpur, Malaysia
and Maintenance Cost Call Us
La Coruna, Spain
Facet Filtration maintains
insulating oil cleaner than new
For
oil cleanliness levels by removing
metallic, particulate, and water
Manama, Bahrain
Clear
contamination to aerospace
specifications. Super clean oil
Mid Glamorgan, United Kingdom
Solutions
eliminates the precursors to oil Porto Alegre, Brazil
oxidation that leads to the formation
of sludge and coking in tap Typical view of LTC Tank Typical view of LTC Tank
Queretaro, Mexico
changers. Facet Filtration eliminates with filtration without filtration
insulating oil replacement cost and 12 months after 12000 operations 12 months after 12000 operations
indefinitely extends costly routine Sacramento, California
load tap changer maintenance.
Stilwell, Oklahoma

• Extend Equipment Life Torino, Italy


Facet Filtration increases the Tulsa, Oklahoma
effectiveness of insulating oil by
maintaining high oil dielectric
strength and interfacial tension and Vernal, Utah
low moisture and acid levels in oil.
Super clean oil prevents LTC contact Weifang, China
over-arcing which minimizes contact
scorching, reduces contact wear,
and extends internal component
and LTC contact life.

• Increase Equipment Life


and Reliability
Installing Facet Filtration can
eliminate the possibility of 9910 East 56th Street North
premature Load Tap Changer Tulsa, OK 74117
failure. Our filtration equipment
turns costly maintenance events
into simple inspections. Eliminate
unexpected outages and increase LTC with filtration LTC without filtration 800 • 223 • 9910
your equipment’s performance and No signs of contact degradation Heavily coked with signs of 918 • 272 • 8700
reliability with Facet Filtration. excessive arcing

www.facetinternational.com
Alternate Filter Selection Available for All Industry Standard Vessels info@facetusa.com

You might also like