Professional Documents
Culture Documents
Content
1. Brieft Description
3. Installtion
5. Troubleshooting
6. Installation Dimensions
Too much power consumed Packing too tight Loosen gland packing
by pump Stuffing box too hot Repace impeller
Impeller worn out Turn down discharger valve to
Too large flow that the pump is reducer flow
working in.
Apnormal noise inside the Flow too large Turn down dischager valve
pump Resistance too hight in the inlet pipe Reduce flow
Pump not primed Suction lift too high Fix leakage
Air leakage into the inlet pipe Lower liquid temperature
Liquid temperature too high
Bearings over-heat Short of lubricant or lubricant too dirty Filled with clean oil or grease
Pump shaft not in alignment to that of Align coupling centerline
the motor Bearing worn out Replace bearing
Vibration Pump shaft not in alignment to that of Align coupling center line
the motor
SIHI CBS
CBS 4016,