You are on page 1of 14

MZ & PARTNERS

ARCHITECTURAL & ENGINEERING CONSULTANCY


Tel: 44 79 845-Fax: 44 79 673-POBox: 5785Doha-Qatar

S TR U C TU R A L D E P A R TM E N T

TOWER CRANE FOOTING


STRUCTURAL DESIGN REPORT

PROJECT: NORTHGATE RETAIL/OFFICE BUILDINGS

0 27-12-2011 A.Z F.H F.M.I ISSUED FOR APPROVAL


Rev. Date By Chkd Appr. Status Revision reason for issue description

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 1 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
TABLE OF CONTENTS

1.0 CHAPTER I: GENRALITES ........................................................................................................ 3


1.1 OBJECT OF THE PRESENT DOCUMENT ............................................................................ 3
1.2 REFERENCE DRAWINGS & DOCUMENTS .......................................................................... 3
1.3 REFERENCES AND CODES ................................................................................................. 3
1.4 MATERIALS PROPERTIES ................................................................................................... 3
2.0 CHAPTER II: DESIGN CALCULATIONS .................................................................................... 5
2.1 DESIGN CONCEPT ............................................................................................................... 5
2.2 DESIGN LOADS..................................................................................................................... 5
2.3 LOADING COMBINATIONS ................................................................................................... 5
2.4 GEOMETRY OF CRANE LEGS ............................................................................................. 5
2.5 OVER TURNING STABILITY CALCULATIONS ..................................................................... 5
2.6 CHECK SLIDING AND SOIL CAPACITY................................................................................ 7
2.7 CHECK PUNCHING ............................................................................................................... 8
2.8 REINFORCEMENT ................................................................................................................ 8

APPENDIX A ………………………………………………………………………………………………………14

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 2 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
1.0 CHAPTER I: GENRALITES

1.1 OBJECT OF THE PRESENT DOCUMENT

The purpose of this document is to provide the final structural analysis and
design for the footing related to the tower crane in the considered project
(Northgate Retail/Office Buildings).

1.2 REFERENCE DRAWINGS & DOCUMENTS

The following drawings & documents have been used for establishing the final
design of the present structure:

 Foundation reaction forces Data sheet - Page 2-39 - For 52.0m height crane

The above data sheets are attached. refer to appendix A.

1.3 REFERENCES AND CODES

The references of codes and standards are:


- Qatar Construction Specification 2002
- BS 8110, 1997 Structural use of concrete - Code of practice For design
and Construction
- BS 8004, 1986 Code of Practice for Foundations
- BS449, 2005 steel for the reinforcement of concrete

1.4 MATERIALS PROPERTIES

1.4.1 Concrete
Concrete compressive strength (Cube) at 28days :
- Blinding Concret C20/25 20MPa
- footings C32/40 40MPa

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 3 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
1.4.2 Reinforcement
Steel bars of yield strength not less than 420MPa to be used for longitudinal &
transversal bars.

This design is for an isolated tower crane foundation.

1.4.3 Soil
The allowable bearing capacity was taken 300KN/m2.

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 4 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
2.0 CHAPTER II: DESIGN CALCULATIONS

2.1 DESIGN CONCEPT

• The footing dimensions was estimated based on over turning moment


calculations with factor of safty 1.5
• Checking for Sliding stability and soil capacity.
• Checking for Punching shear
• calculations for required reinforcement

2.2 DESIGN LOADS

As per manufacturer data sheet, the most critical design loads were considered
for the case of crane in operation as follows:

Moment (Over turning) M=4908 KN.m


Horizontal force (Sliding) H=91KN
gravity Load V=917 KN

2.3 LOADING COMBINATIONS

The given loads are mixed of dead loads, wind loads and live loads. However, a
1.5 ultimate factor can be considered as conservative load factor for concrete
design.

2.4 GEOMETRY OF CRANE LEGS

The crane have a base dimensions with square shape of 1.98m side length. The
fixing leg of 1.4m length should be embedded with 1.13m inside the footing. This
means that the footing should has minimum thickness 1.40m.

2.5 OVER TURNING STABILITY CALCULATIONS

As per the figure below, the stability calculations were calculated as follows:

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 5 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
Figure 1: Stability against over turning

assume h=1.50m ==>


over turning moment MOT = 4908+91*1.5 = 5044.5 KN.m
footing weight = 25*1.5*L2 = 37.5L2
Stability moment = Mst = 917*L/2 + 37.5*L2*L/2 = 18.75 L3 + 458.5 L
Use Factor of safty = F.O.S = 1.5 ==>

1.5=Mst / MOT ==>

18.75 L3 + 458.5 L - 7566.75 = 0 ==> L=6.5 m satisfy the equation.

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 6 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
2.6 CHECK SLIDING AND SOIL CAPACITY

- Sliding:
Sliding coefficient is equal H=tan I where I=angle of internal friction ==> H=tan
30 = 0.57, Use 0.5
Sliding force = H = 91KN
resisting force = (V+W)*H = (917+1584.375)*0.50 = 1250.7 >>91, OK

- Soil capacity:
soil stress = f = (V+W)/A ± MOT/(L*L2/6)
A=footing area=L2
==>
f= 2501.375/42.25 ± 4908/(6.53/6) = 59.2 ± 107.23

Negative value is rejected ==> use another approach. refer to figure 2.

Figure 2: soil stress calculations

e=MOT/(V+W) = 4908/2501.375 = 1.96 m ==> r=1.29 m

0.5f*(3r)*L = (V+W) ==> 0.5f*3.87*6.5=2501.375 ==> f=198.88 KN/m2 < 300KN/m2, OK

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 7 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
2.7 CHECK PUNCHING

The fixing leg consists of several steel plates welded to the main shaft. Each
plate of 350x350mm dimensions. The maximum force act for punching is
considered for the case where the moments is diagonal on the footing.

Fpunching = MOT/√(2*2.32) +V/4 = 4908/3.25 + 917/4 = 1510.2+229.25=1739.45 KN

fs= punching stress directly at plate edge = 1.5*1739450/(4*350*d)


where d=footing depth = 1500-65=1435mm ==>
fs=1.3MPa << 0.8√fcu=5MPa (BS8110-1:1997, clause 3.7.7.2)

it is obvious that the punching effect is very negligible.

2.8 REINFORCEMENT

For hign accuracy, the bending moment calculations were performed through
finit element analysis. Autodesk ROBOT structural analysis software was used for
that purpose. Note that only the large footing was considered (most critical)
and the reinforcement was applied to the small one.
The acting forces on the crane legs were calculated and applied to the model
as follows:
Compression side = M/2.3 + V/4 = 4908/2*2.3 + 917/4 = 1067+229.25=1296.25 KN
Tension side = M/2.3 - V/4 = 4908/2*2.3 - 917/4 = 1067-229.25 =837.75 KN
The fixing leg

The following figures represent the footing geometry with acting loads, soil stress
(As a verification on the manual calculations) and the service bending
moments maps.

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 8 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
Figure 3: acting forces on footing

Figure 4: Soil reaction

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 9 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
Figure 5: Moment on footing

The ultimate bending moment = 347*1.5=520.5 KN.m/m


==> T25@200mm is sufficient as per following data sheet extracted from ROBOT
expert software.

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 10 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
Section design for simple bending
1. Assumptions:

Concrete: fcu = 40.0 (MPa) Reinforcing steel: fy = 420.0 (MPa)

• Code: BS 8110

2. Section:

b = 1000.0 (mm)
h = 1500.0 (mm)
ds = 75.0 (mm)
d' = 75.0 (mm)

3. Applied loads:
Mmax (kN*m) Mmin(kN*m)
at Ultimate Limite State 520.50 0.00

4. Results:
Reinforcement:
Theoretical area: As = 2264.3 (mm2) A's = 0.0 (mm2)
Reinforcement ratio: ρ = 0.16 (%)
ρmin = 0.16 (%)
ρmax = 4.00 (%)
Case analysis:

Case No 1: ULS M = 520.50 (kN*m)


- not significant case

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 11 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
APPENDIX A
(Data sheets)

CLIENT: CONSULTANT: MAIN CONTRACTOR:


EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 12 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING
CLIENT: CONSULTANT: MAIN CONTRACTOR:
EQUINOX – NORTHGATE ASSOCIATED CONSULTING HABTOOR LEIGHTON GROUP
ENGINEERS

SUB CONTRACTOR: SUBCONSULTANT TO UNITED: MZ Project No:


UNITED EQUIPMENTS GROUP MZ & PARTNERS 10109 Rev. 0

Project: Northgate Retail/Office Building Sheet: 13 of 13


DESIGN CALCULATIONS – TOWER CRANE FOOTING