Professional Documents
Culture Documents
COMPOSITE FLOOR
HB306
Z275 GALVANIZED
LIMIT STATES
DESIGN
METRIC
DEPTH FROM MAXIMUM FACTORED PHYSICAL
Note SECTION MODULUS Moment of Inertia
NEUTRAL REACTIONS
1. Load Tables are NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO PROPERTIES
CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR STEEL PROPERTIES
based on the design Sm Ss Im If
THICKNESS STEEL GALVANIZED DECK Y b (kN) (kN)
of ONE-WAY (mm3 x 103) (mm3 x 103) (mm4 x 103) (mm4 x 103)
(mm) (mm2) (kg/m2) (mm)
composite slabs
carrying uniformly 0.76 1429.7 11.64 25.94 26.67 1186.8 1309.8 42.83 13.6 21.5 (PER METRE WIDTH)
distubuted loads on a 0.91 1717.3 13.94 33.41 33.81 1488.4 1572.3 42.94 19.0 30.1 In accordance
simple span basis. with CSA
1.22 2284.3 18.42 46.42 48.39 2071.6 2088.8 43.17 32.1 50.7
For complete design Specification
criteria see the 1.52 2856.1 23.03 59.06 60.10 2608.4 2608.4 43.40 48.2 76.4
S136-07
VICWEST Hi-Bond
Composite Floor SLAB THICKNESS 141 151 166 176 PHYSICAL
Designer's Manual. h(mm)
Slab Weight, W1(kN/m2) 2.32 2.55 2.90 3.12 PROPERTIES
2. A uniform loading in
Concrete Volume, (m3/m2) 0.095 0.105 0.120 0.130 COMPOSITE SLAB
excess of 10 kPa Base Steel Nominal (PER METRE WIDTH)
(200 psf) is often an Thickness IC d IC d IC d IC d
indication of Composite
(mm)
concentrated or Moment of
moving loads. Such 0.76 13790 98.2 16828 108.2 22205 123.2 26380 133.2 Inertia,
conditions may 0.91 14721 98.1 17953 108.1 23669 123.1 28103 133.1 I C (mm4 x 103)
require additional
1.22 16398 97.8 19978 107.8 26309 122.8 31214 132.8 Effective Depth,
reinforcing steel.
Contact VICWEST d (mm)
1.52 17920 97.6 21814 107.6 28703 122.6 34040 132.6
for additional design
Base Steel
information
Nominal 1 2 3 1 2 3 1 2 3 1 2 3
LOAD TABLE
3. Slab Thickness h, is Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span
from underside of (mm) (mm)
steel deck to top of 2600 11.7 11.7 11.7 12.9 12.9 12.9 14.6 14.6 14.6 15.8 15.8 15.8 Maximum
concrete. Maximum 2800 10.4 10.4 10.4 11.4 11.4 11.4 13.0 13.0 14.1 14.1 Specified
0.76
span is not to exceed 3000 9.3 9.3 10.2 10.2 11.7 Uniformly
32h. 3200 8.4 Distributed Load
4. Properties and loads 2600 13.7 13.7 13.7 15.1 15.1 15.1 17.1 17.1 17.1 18.5 18.5 18.5
are based on Grade in kN/m 2 (kPa)
2800 12.2 12.2 12.2 13.4 13.4 13.4 15.3 15.3 15.3 16.5 16.5 16.5
230 steel (Grade 33 3000 10.9 10.9 10.9 12.1 12.1 12.1 13.7 13.7 13.7 14.8 14.8 14.8
steel) with a 0.91
3200 9.9 9.9 9.9 10.9 10.9 10.9 12.4 12.4 13.5 13.5 Shear Bond
minimum yield stress 3400 9.0 9.0 9.0 10.0 10.0 11.4 Coefficents
of 230 MPa (33,000
3600 8.3 k 1 = 79.7831
psi) and a maximum
3000 14.4 14.4 14.4 15.8 15.8 15.8 18.0 18.0 18.0 19.5 19.5 19.5 k 2 = 71.2935
stress under
3200 13.1 13.1 13.1 14.4 14.4 14.4 16.4 16.4 16.4 17.7 17.7 17.7 k 3 = 0.2576
Factored loads of 207
MPa (29,700 psi). 3400 12.0 12.0 12.0 13.2 13.2 13.2 15.0 15.0 15.0 16.2 16.2 16.2 k 4 = -0.0676
3600 11.0 11.0 11.0 12.1 12.1 12.1 13.8 13.8 13.8 14.9 14.9 14.9
1.22
5. Load values are 3800 10.2 10.2 10.2 11.2 11.2 11.2 12.8 12.8 13.8 13.8
based on Normal 4000 9.5 9.5 10.4 10.4 11.9
Weight Concrete 4200 8.9 8.9 9.8
(density of 2300 4400 7.9
kg/m3) (145 pcf) with 3400 14.7 14.7 14.7 16.3 16.3 16.3 18.5 18.5 18.5 20.0 20.0 20.0
a minimum 3600 13.6 13.6 13.6 15.0 15.0 15.0 17.1 17.1 17.1 18.5 18.5 18.5
compressive strength 12.6 13.9 15.9 17.2
3800 12.6 12.6 13.9 13.9 15.9 15.9 17.2 17.2
of 20.7 MPa (3,000 1.52 4000 11.8 11.8 11.8 13.0 13.0 13.0 14.8 14.8 16.0 16.0
psi) and a Modular
4200 10.5 10.5 10.5 12.1 12.1 13.8 13.8 14.9 14.9
Ratio n=9
4400 9.1 9.1 10.8 10.8 13.0 13.0 14.0
4600 8.0 8.0 9.7 9.7
Continued on back
In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved
HI-BOND
COMPOSITE FLOOR
HB306
Z275 GALVANIZED
LIMIT STATES
DESIGN
IMPERIAL
PHYSICAL DEPTH FROM MAXIMUM FACTORED
SECTION MODULUS Moment of Inertia Note
NEUTRAL REACTIONS
PROPERTIES NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO
Continued from
STEEL PROFILE CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR
STEEL GALVANIZED Sm Ss Im If DECK Y b front
THICKNESS (pounds) (pounds)
(inches) (inches2) (lb/ft2) (inches3) (inches3) (inches4) (inches4) (inches)
(PER FOOT WIDTH) .030 0.675 2.384 0.4825 0.4961 0.8691 0.9591 1.686 932 1473 6. No additional
In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved