HI-BOND

COMPOSITE FLOOR

HB938-INV
Z275 GALVANIZED

LIMIT STATES
DESIGN
METRIC
DEPTH FROM MAXIMUM FACTORED PHYSICAL
Note SECTION MODULUS Moment of Inertia
NEUTRAL REACTIONS
1. Load Tables are NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO PROPERTIES
CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR STEEL PROPERTIES
based on the design Sm Ss Im If
THICKNESS STEEL GALVANIZED DECK Y b (kN) (kN)
of ONE-WAY (mm3 x 103) (mm3 x 103) (mm4 x 103) (mm4 x 103)
(mm) (mm2) (kg/m2) (mm)
composite slabs
carrying uniformly 0.76 996.8 8.08 9.76 9.59 228.3 228.3 14.90 10.9 15.7 (PER METRE WIDTH)
distubuted loads on a 0.91 1197.4 9.65 12.31 11.70 274.0 274.0 14.95 15.3 22.3 In accordance
simple span basis. with CSA
1.22 1593.0 12.83 16.21 15.87 364.0 364.0 15.06 25.8 38.4
For complete design Specification
criteria see the 1.52 1992.1 15.96 20.06 20.00 454.4 454.4 15.17 38.9 58.7
S136-07
VICWEST Hi-Bond
Composite Floor SLAB THICKNESS 101 111 126 136 PHYSICAL
Designer's Manual. h(mm)
Slab Weight, W1(kN/m2) 2.11 2.33 2.67 2.90 PROPERTIES
2. A uniform loading in
Concrete Volume, (m3/m2) 0.088 0.098 0.113 0.123 COMPOSITE SLAB
excess of 10 kPa Base Steel Nominal (PER METRE WIDTH)
(200 psf) is often an Thickness IC d IC d IC d IC d
indication of Composite
(mm)
concentrated or Moment of
moving loads. Such 0.76 6839 86.1 8918 96.1 12749 111.1 15821 121.1 Inertia,
conditions may 0.91 7300 86.1 9507 96.1 13565 111.1 16812 121.1 I C (mm4 x 103)
require additional
1.22 8127 85.9 10568 95.9 15042 110.9 18611 120.9 Effective Depth,
reinforcing steel.
Contact VICWEST d (mm)
1.52 8873 85.8 11528 95.8 16388 110.8 20256 120.8
for additional design
Base Steel
information
Nominal 1 2 3 1 2 3 1 2 3 1 2 3
LOAD TABLE
3. Slab Thickness h, is Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span
from underside of (mm) (mm)
steel deck to top of 1200 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Maximum
concrete. Maximum 1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Specified
0.76
span is not to exceed 1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Uniformly
32h. 1800 18.5 18.5 20.0
Distributed Load
4. Properties and loads 1200 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
are based on Grade in kN/m 2 (kPa)
1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
230 steel (Grade 33 1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
steel) with a 0.91
1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 Shear Bond
minimum yield stress 2000 16.9 16.9 18.8 18.8 20.0 Coefficents
of 230 MPa (33,000
2200 k 1 = 98.1159
psi) and a maximum
1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 2 = 69.1496
stress under
1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 3 = 0.0603
Factored loads of 207
MPa (29,700 psi). 1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 4 = 0.0485
2000 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
1.22
5. Load values are 2200 17.0 17.0 17.0 18.9 18.9 20.0 20.0 20.0 20.0
based on Normal 2400 14.6 14.6 16.3 16.3
Weight Concrete 2600
(density of 2300 2800
kg/m3) (145 pcf) with 1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
a minimum 2000 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0
compressive strength 19.6 20.0 20.0 20.0
2200 19.6 19.6 20.0 20.0 20.0 20.0 20.0 20.0
of 20.7 MPa (3,000 1.52 2400 16.8 16.8 16.8 18.8 18.8 18.8 20.0 20.0 20.0 20.0
psi) and a Modular
2600 14.7 14.7 16.4 16.4 18.9 18.9 20.0
Ratio n=9
2800 12.9 12.9 14.4
3000

Continued on back
In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved
HI-BOND
COMPOSITE FLOOR

HB938-INV
Z275 GALVANIZED

LIMIT STATES
DESIGN
IMPERIAL
PHYSICAL DEPTH FROM MAXIMUM FACTORED
SECTION MODULUS Moment of Inertia Note
NEUTRAL REACTIONS
PROPERTIES NOMINAL MASS WITH
MIDSPAN SUPPORT MIDSPAN FULL
AXIS TO
Continued from
STEEL PROFILE CORE AREA OF ZF75 BOTTOM OF EXTERIOR INTERIOR
STEEL GALVANIZED Sm Ss Im If DECK Y b front
THICKNESS (pounds) (pounds)
(inches) (inches2) (lb/ft2) (inches3) (inches3) (inches4) (inches4) (inches)

(PER FOOT WIDTH) .030 0.471 1.655 0.1815 0.1784 0.1672 0.1672 0.587 747 1076 6. No additional

In accordance reinforcing steel is


.036 0.566 1.977 0.2290 0.2176 0.2006 0.2006 0.589 1048 1528
required for the slab
with CSA
.048 0.753 2.628 0.3015 0.2952 0.2666 0.2666 0.593 1768 2631 thicknesses shown
Specification on this table. For
.060 0.941 3.268 0.3731 0.3720 0.3327 0.3327 0.597 2666 4022
S136-07 temperature
PHYSICAL SLAB THICKNESS 4.00 4.50 5.00 5.50 reinforcing (crack-
h(inches) control) steel, see
PROPERTIES Slab Weight, W1(lb/ft2) 44.3 50.3 56.2 62.2 the VICWEST Hi-
COMPOSITE SLAB Concrete Volume, (cu yd/100 ft2) 1.074 1.228 1.382 1.537 Bond Composite
Base Steel Nominal Floor Designer's
(PER FOOT WIDTH)
Thickness IC d IC d IC d IC d Manual.
Composite
(inches)
Moment of
.030 5.0892 3.413 7.0877 3.913 9.5402 4.413 12.4899 4.913 7. Hi-Bond composite
Inertia,
load capacities are
4
I C (inches ) .036 5.4323 3.411 7.5532 3.911 10.1503 4.411 13.2669 4.911 dependant on the
Effective Depth, .048 6.0478 3.407 8.3924 3.907 11.2547 4.407 14.6792 4.907 material finish of the
d (inches) steel. VICWEST
.060 6.6029 3.403 9.1532 3.903 12.2611 4.403 15.9722 4.903 publishes load tables
for ZF75 Galvanneal
Base Steel
LOAD Nominal 1 2 3 1 2 3 1 2 3 1 2 3 steel and Z275
TABLE Thickness Span Span Span Span Span Span Span Span Span Span Span Span Span Galvanized steel. For
(inches) (inches) other finishes contact
your local VICWEST
Maximum 4'-6" 400 400 400 400 400 400 400 400 400 400 400 400
office.
Specified 5'-0" 400 400 400 400 400 400 400 400 400
.030
Uniformly 5'-6" 400 400 400 400 400 400
6'-0" 378 378 8. Loads for the deck
Distributed Load
2 5'-0" 400 400 400 400 400 400 400 400 400 400 400 400 acting as a Form
in lb/ft (psf) include Slab Weight,
5'-6" 400 400 400 400 400 400 400 400 400 400 400
6'-0" 400 400 400 400 400 400 400 400 400 W 1 and a
.036
6'-6" 362 362 400 400 400 construction load of
7'-0" 318 318 1.0 kN/m2 (21 psf)
7'-6" Uniformly Distrubuted
5'-6" 400 400 400 400 400 400 400 400 400 400 400 400 Live Load
400 400 400 400 OR
6'-0" 400 400 400 400 400 400 400 400
2.0 kN/m (137 lb/ft)
6'-6" 400 400 400 400 400 400 400 400 400 400 400 400
Transverse Live
7'-0" 376 376 376 400 400 400 400 400 400 400
.048 Load.
7'-6" 334 334 383 383 400 400
8'-0" 299 299 342
8'-6" 9. Load Table values
9'-0" allow for slab self
7'-0" 400 400 400 400 400 400 400 400 400 400 400 400 weight.
7'-6" 385 385 385 400 400 400 400 400 400 400 400
8'-0" 345 345 345 396 396 396 400 400 400 400
.060 8'-6" 311 311 357 357 400 400
9'-0" 282 282 324
9'-6" 257
10'-0"

In accordance with ongoing efforts to improve our products and their performance, Vicwest
reserves the right to change without notice the specifications contained herein.
The contents herein are for general information and illustrative purposes only and are not intended to
serve as any type of advice. Every effort is made to ensure the accuracy of the information included in
this brochure and it is believed that the information contained herein is accurate and reliable as of the
date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any
information included in this brochure. Any reliance on any information without consultation with Vicwest VW00147EN10/10
or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved