TRIAL DESIGN CHECKS

MEMBER Le.x Le.y LOAD N* M*x M*y SECTION Ns Msx Msy Mb Ncx Ncy Mcx Miy SECTION MEMBER
(m) (m) CASE (kN) (kNm) (kNm) (kN) (kNm) (kNm) (kNm) (kN) (kN) (kNm) (kNm) <1.0 <1.0
Stubs
Member flexural capacity for Plates bending about strong axis - compact sections (ie b/t<10)

b t Fy f.Msx f.Msy f.Mb a.m a.s Mm


mm mm Mpa kNm

100 8 250 4.5 0.36 4.5 1.82 0.79 1.9


100 10 250 5.6 0.56 5.5 1.82 0.54 1.9

110 8 250 5.4 0.40 5.4 1.82 0.77 1.9


60 6 250 1.2 0.12 1.2 1.82 0.78 1.9
M2 M3 M4 Iy Le J M.o
kNm kNm kNm m4 m m4 kNm

0.475 0.95 1.425 4.27E-09 0.40 1.71E-08 8.48E+00


0.475 0.95 1.425 8.33E-09 1.60 3.33E-08 4.14E+00

0.475 0.95 1.425 4.69E-09 0.40 1.88E-08 9.33E+00


0.475 0.95 1.425 1.08E-09 0.40 4.32E-09 2.15E+00