Legend/Notes
Safety, Health and Environmental Information
B01
Notes below are additional to hazards/risks normally GENERAL NOTES:
associated with this type of work:
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS STATED
COUNTRY CONSTRUCTION:
OTHERWISE.
107050
2. UNDERGROUND SERVICE LOCATIONS ARE TO BE VERIFIED PRIOR
Ci. FULL BURIED SERVICES TO BE CHECKED IN TO CARRYING OUT WORKS USING A CAT SCAN OR OTHER
D-1.3
D-1.1 ACCORDANCE WITH NETWORK RAIL PROCEDURES SUITABLE MEANS.
PLATFORM 1
ECV-
Ciii. WORKING AT HEIGHT. PROVIDED BY WED TEAM. SUBWAY SECTIONS PRE INDICATIVE
BASED ON AS BUILT RECORDS, SURVEY PHOTOS AND MODEL.
D-1.4
Civ. EXISTING CABLES AND PIPES TO BE PROTECTED
D-1.2
Mi DURING CORING. 6. POSITION OF DUCTS TO BE CORED SHOULD BE LOCALLY
PLATFORM 3
P2R-
PASSENGER SUBWAY
148234-
107050 107050 107050 107050 MAINTENANCE: 8. SECTIONS OF PLATFORM 2 ARE ONLY FOR GUIDANCE AND ARE
ASSUMED TO BE SIMILAR TO AS-BUILT DRAWINGS OF PLATFORM 4
awi
Mi. DAMAGE IN CABLING PASSENGER SUBWAY FROM PDF DMFP60018963 WITH REFERENCE
Ci TO PHOTOS SHOWN IN DRAWING.
Dr
D-4.2 Ci
D-4.4 DISMANTLING/DEMOLITION (FUTURE)
9. SECTIONS OF PLATFORM 1 ARE DRAWN ACCORDING TO PHOTOS
D-4.1 PASSENGER SUBWAY SHOWN IN DRAWING.
Di.
D-4.3 PLATFORM 4
10. CORING DISTANCE FROM CEILING TO TOP OF CORE SHOULD BE A
For more detailed information please refer to the designers H&S MINIMUM OF 200mm.
hazard record. Everyday or low risk hazards have not been
indicated on this drawing, neither have hazards that should be
DOWN MAIN UP MAIN DOWN RELIEF UP RELIEF obvious to a competent contractor. Should any additional
hazards be identified the contractor should notify all the relevant
project team members.
Lifesaving Rules
D-2.3
D-2.1 COLOUR KEY:
Mi Status Suitability
Civ
370
Ci
Fit for Internal Review & Comment S3
370
Civ
Outer Stations
Drawing Title
148234-191-P2R-MLN1-DRG-ECV-107050 B01