Professional Documents
Culture Documents
AUTHORITY STAMP:
Millimetres
GENERAL NOTES:
1. THIS DRAWING IS THE COPYRIGHT OF ATK ENGINEERING
10
1. All dimensions shown area in mm unless otherwise stated. All Levels shown are in
m unless otherwise stated.
2. This drawings is for design intent purpose only.It should be read in conjunction
with all Engineering/Architectural/Landscape and Interior Design Drawings as
Required.
3. Sub-contractor to generate all shop drawings. Neolight will then review and
return with comments to Sub-contractor and will need PRIOR APPROVAL BEFORE
CONTINUING.
4. Detail Shop drawings shall be submitted by sub-contractor and obtain approval
from consultant before proceeding.
5. Sub-contractor must check all set-out and measurement on site.
6. Any discrepancies must be reported immediately to the consultant before
proceeding.
7. This drawing consist of general M&E services and functional lighting legends,
sub-contractor shall verify and cross check.
8. All the dimension and linear lengths provided should be verified against the shop
drawings. contractors and suppliers to quote against shop drawings and site
conditions.
1 A L P H A C O D E S e . g . A A = L U M I N A I R E T Y P E
2001 N U M E R I C C O D E S e. g. 1.1 = LOGICAL CONTROL
C H A N N E L
* S E E L U M I N A I R E & C O N T R O L
H6 H7 * S E E C O N T R O L S C H E D U L E F O R M O R E
D E T A I L F O R D I M M I N G / S W I T C H I N G
4.050°
9700 9700 9700 8000 11400
8.125° H8 LI GHTI NG C ODE PLEAS E RE FER TO NEO LIG HT SPE CI FI CATI ONS
8.12
5°
H9
POSSIBLE LOCATION FOR FACADE LIGHTING
REMOTE DRIVER
8.7
0 0°
H10
FA(2)
F-03.04
147
50
H11
HC 6.0
17° H12
8.42
8°
H13
H14
8750
8.429° H15 H16 H17 H18 H19 H20 H21 H22 H23 H24 H25 H26 H27 H28 H29
6.126° 7875 10425 10425 10425 11000 11000 11000 11000 11000 11000 11000 11000 11000 11000
HD
POSSIBLE LOCATION FOR FACADE LIGHTING
REMOTE DRIVER
8750
FA(2)
F-03.02
153600
00
1UP
UP
21000
432001
DN
001
HE
FA(2)
F-03.04
FA(2) FA(2) FA(2)
F-03.02 F-03.02 F-03.02
KEY PLAN
HC
8750
HD
FA(2)
SR-03
F-03.02
SR-01
8750
1470
30-CG
C 26 APR 20 ISSUED FOR SCHEME DESIGN JR ME AA
B 29 JAN 20 ISSUED FOR SCHEME DESIGN LC ME AA
7
HOUSEKEEPING
93
TROLLEY
FA(2) FA(2)
FA(2)
F-03.02 F-03.02 Client
F-03.02
Project Management
Engineering Office - Al
Satwa P.O. Box 12188 ,
Dubai
Lead Consultant
Architect/Engineer of Record
neolight
R e gi s t e r e d i n R a s A l K h a i m a h a s N e o a l p ha F Z C w i t h a L i a s o n O f f i c e i n D u b ai
D e y a a r B u i l d i n g , A l B a r s h a 1
O f f i c e # 3 0 2 P . O . B o x 2 1 5 4 2 3 , T e l : + 9 7 1 4 3 7 9 2 8 9 7
eMail: dubai@neolightdesign.com www.neolightdesign.com
Project Title
MARSA AL ARAB
Date:
Drawing Title
01 MAA 01 - FACADE LIGHTING LAYOUT - 3RD FLOOR - FLOOR PLAN SCALE: 1:300 MTS MAA-NEO-MAA1-LD-GA-03-1003 C
Author: