Professional Documents
Culture Documents
NO DRAWINGS TO BE SCALED.
ALL MEASUREMENTS, HEIGHTS AND LEVELS TO BE VERIFIED ON SITE PRIOR TO
COMMENCEMENT OF CONSTRUCTION AND ADAPTED TO SUGGESTED BUILDING WORK.
ANY DISCREPANCY OR CONTRADICTION TO BE DISCUSSED WITH THE ARCHITECT
IMMEDIATELY.
site boundary
ALL DIMENSIONS INDICATED ON PLAN TO BE SET OUT ON A LEVEL HORIZONTAL PLANE .
building line
ALL BRICKWORK TO BE SET OUT USING A PROFILE MARKED 85mm C/C.
THE CONTRACTOR IS RESPONSIBLE FOR THE CORRECT SETTING OUT OF THE BUILDING
site boundary
WORK ON SITE WITH PARTICULAR REFERENCE TO SITE BOUNDARIES, SERVITUTES AND
building line
BUILDING LINES.
THE CONTRACTOR IS TO BUILD IN APPROVED D.P.C's TO ALL EXTERNAL WALLS, UNDER
FLOORS AND UNDER WINDOW CILLS.
concrete roof slab as per Engineer to receive QUALITY OF ALL MATERIAL AND CRAFTMANSHIP TO COMPLY WITH THE RELEVANT S.A.B.S
approved waterproofing and chipped stone New chromadek corrugated iron STANDARDS.
chromadek corrugated iron roof + 36.000 (7500mm height restriction) THE CONTRACTOR SHOULD HAVE A FULL SET OF DRAWINGS AVAILABLE ON SITE AT ALL
sheeting, colour dove grey on roof sheeting, colour dove grey on TIMES.
approved timber trusses approved timber trusses THE CONTRACTOR IS RESPONSIBLE FOR HIS OWN QUALITY CONTROL.
ALL FLOOR LEVELS SHOWN ON THIS DRAWING REFER TO UNFINISHED FLOOR LEVELS.
1800
MIDAS: Talc powder
at least 200mmx600mm, min. 600mm.
channel +28.670 uffl
200mm under ground level
or to eng. details. Where any waste or soil branches
+28.670 uffl NOTE: THESE ARE MINIMUM are connected to a stack the centre
dpc DECK
+28.500 mean ground level
ngl dpc ngl
+28.500 mean ground level
REQUIREMENTS ONLY line of the waste branch shall not
intersect the stack within 200mm
Lintels to be supported min. 150mm below the centre line of the soil
floor finish on concrete surface for openings up to branch.
bed and well compacted fill 3,0m and at least 220mm for
openings up to 4,8m. Sewer connection : as shown: with
rodding eye ormanhole within 1,5m
concrete foundation concrete foundation Brickforce to built in every course from connection.
as per Engineer as per Engineer below floor level and above
window level, every third course
between, in continuous bands.
SECTION A-A
scale 1:50
IF IN DOUBT ASK
DONT ASSUME
site boundary
building line
chromadek corrugated iron roof
sheeting, colour dove grey on
+ 36.000 (7500mm height restriction) approved timber trusses + 36.000 (7500mm height restriction)
site boundary
building line
+34.280 wall plate height saftey glass saftey glass +34.195 top of parapet behind 34.120 top of chimney saftey glass saftey glass
+34.110 top of parapet
EAST ELEVATION SCALE 1:100 WEST ELEVATION SCALE 1:100 32 Clarendon Crescent
Ysterplaat
021 510 0072
079 502 6645
Daleen Holloway - PfSnrArch T
SACAP Registration - PSAT 20714
Cape Town
7405 daleen@hollowayandhound.com
www.hollowayandhound.com
PROJEK PROJECT
site boundary
building line
+ 36.000 (7500mm height restriction) approved timber trusses + 36.000 (7500mm height restriction)
MR + MRS HUGO
+35.835 top of apex +35.835 top of apex
ERF 1039
W19 W19 FERNKLOOF ESTATE
saftey glass Ø40mm vent pipe saftey glass saftey glass
+34.110 top of parapet chromadek corrugated iron roof STAND NO 55
sheeting, colour dove grey on +34.280 wall plate height
approved timber trusses
+33.770 underside slab aluminium purpose W17
+33.600 underside slab
made window
plaster and paint, plaster and paint, colour
D17 by Architect purpose made +32.920 top of parapet
colour by Architect whb +32.070 top of parapet +32.070 top of parapet aluminium window
+31.730 top of parapet MIDAS: Talc powder wc timber slats over duct
TITEL TITLE
+31.220 underside slab Ø50mm pvc wp plaster and paint, rwp ELEVATIONS
aluminium purpose timber slat colour by Architect
MIDAS: Talc powder SECTION A:A
site boundary
SOUTH ELEVATION SCALE 1:100 NORTH ELEVATION SCALE 1:100 TEK. NO. DRWG. NR:
ARCHITECTURAL PROFESSIONAL
DALEEN HOLLOWAY
PSAT 20714 2024-11-002
CONTACT NR: 079 502 6645