You are on page 1of 2

M/58112/09

Vacuum Pump
- 0,85 bar

● Compact dimensions

● Compressed air driven

● Low sound level

● Easy installation

Technical Data Ordering Information


Medium: To order a vacuum pump
Compressed air, filtered and non-lubricated quote: M/58112/09
Operation:
Single stage ejector
Operating Pressure:
5 bar optimum
8 bar maximum
Vacuum: Accessories See page
- 0,85 bar maximum Pneumatic vacuum switch N 4.3.101.01
Operating Temperature: Electric vacuum switch N 4.3.111.01
+150˚C Electronic vacuum switch N 4.3.121.01
Flat suction cups N 3.5.011.01
Weight:
Bellows suction cups N 3.5.031.01
0,054 kg
Vacuum gauge N 3.4.015.03
Sound Level:
66/74 dB (A) vacuum port closed/ open
Materials:
Anodised aluminium housing, brass nozzles

P+ R

P-

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
9/96 N/UK 3.4.005.01
For your local Norgren Technical Sales Centre phone 0345 662266. For your local Norgren Distributor phone 0345 227777.
IMI Norgren Limited, PO Box 22, Eastern Avenue, Lichfield, Staffordshire WS13 6SB
M/58112/09

Characteristics (All values given apply to an atmospheric pressure of 1013 mbar)

Air Consumption Vacuum Induced air (Nl/min), free air


(Nl / min.) ( bar )
Model 0 - 0,1 - 0,2 - 0,3 - 0,4 - 0,5 - 0,6 - 0,7 - 0,8
100 - 1,0 M/58112/09 28 24 18 14 11 8 5,5 3 1
90 - 0,9
80 - 0,8
70 - 0,7
Time (sec) for evacuation of 1 litre volume to vacuum
60 - 0,6
50 - 0,5 Model - 0,1 - 0,2 - 0,3 - 0,4 - 0,5 - 0,6 - 0,7 - 0,8 0,85
40 - 0,4 M/58112/09 0,27 0,56 0,89 1,44 2,00 2,88 4,31 7,97 14,36
30 - 0,3
20 - 0,2 Note: Values given in the tables are theoretical and apply to an operating pressure of 5 bar
10 - 0,1
0 ( bar ) 0 ( bar )
0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8
Operating Pressure Operating Pressure

Tube Dimensions Model Compressed air Vacuum Exhaust


Recommended tube dimensions M/58112/09 ≥∅3 ≥∅6 ≥∅6
(internal diameter)

Basic Dimensions P+ R ø 4,5


G 1/8

25
16,5
7

G 1/8 20

P- 27
42

Warning
These products are intended for use in industrial compressed air sys- The system designer is warned to consider the failure modes of
tems only. Do not use these products where pressures and tempera- all component parts used in fluid power systems and to provide ade-
tures can exceed those listed under ‘Technical Data’. quate safeguards to prevent personal injury or damage to equipment
in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the
for non-industrial applications, life-support systems, or other applica- system instructional manual if protection against a failure mode
tions not within published specifications, consult NORGREN. cannot be adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in warnings found in instruction sheets packed and shipped with
fluid power systems can fail in various modes. these products.

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.
N/UK 3.4.005.02 9/96
For your local Norgren Technical Sales Centre phone 0345 662266. For your local Norgren Distributor phone 0345 227777.
IMI Norgren Limited, PO Box 22, Eastern Avenue, Lichfield, Staffordshire WS13 6SB

You might also like