This document contains calculations to determine the safe working load (SWL) for a stand. It lists the operating weight and load distribution of the equipment. It then calculates the required SWL as 1.2-1.5 times the maximum load on one side. Dimensions and material properties are provided for the plate used. Stress calculations are shown to determine the average allowable compressive stress. The minimum safety factor of 3 is met for the final SWL design.
This document contains calculations to determine the safe working load (SWL) for a stand. It lists the operating weight and load distribution of the equipment. It then calculates the required SWL as 1.2-1.5 times the maximum load on one side. Dimensions and material properties are provided for the plate used. Stress calculations are shown to determine the average allowable compressive stress. The minimum safety factor of 3 is met for the final SWL design.
This document contains calculations to determine the safe working load (SWL) for a stand. It lists the operating weight and load distribution of the equipment. It then calculates the required SWL as 1.2-1.5 times the maximum load on one side. Dimensions and material properties are provided for the plate used. Stress calculations are shown to determine the average allowable compressive stress. The minimum safety factor of 3 is met for the final SWL design.
Front (Wt) 31,457 Kg Rear (Wr) 35,473 Kg Load Max 1 side(Lmax) 17,736 Kg SWL Required (1,2-1,5)Lmax 26,605 Kg Material Plat 15 mm Plate Thickness 1 (s)-effective 15 mm Plate Thickness 2 (t)-effective 15 mm Plate Width 1(b)-effective 560 mm Plate Width 2(d)-effective 280 mm Cross Section Area (A) 12,375 mm² Moment Inertia (I) 27,593,281 mm4 Radius of gyratio (k) 47 mm Column Length (L) 1,250 mm Efeective Length Tactor (K) 1 Slenderness ratio (KL/k) 26 Modulus Elasticyty (E) -ASM Table E1 207,000 Mpa
Yield Point (sy) - ASM Table E1 252 Mpa
Cc 127 Safety Faktor (Sf) 2 (AISC Formula for KL/k <Cc)
Average Allowable Compressive Unit Stress (s)
145 Mpa (AISC Formula KL/k<Cc) Weld Quality (Wq) 1 Tatique Factor (ff) Life 3 years and for next 3 years 1
876,794 N SWL Design 89,469 kg
Safety Factor (Sf) 3.36
Minimum Standart Safety Factor For Jack Standart Construction 3
Untuk Mengakhiri Program ini Tekan (Y) lalu enter Di kolom yang berwarna Hijau ''''''''''wasalam''''''''''''' "KYAI TAKERAN SOFWARE"