D12M Off-Spec. Clinker Silo Design Calculations
D12M Off-Spec. Clinker Silo Design Calculations
BG1= 36 m BG4= -1 m
BG2= 30 m BG5= -4.2 m
BG3= 9 m
DIAMETER OF SILO D= 12 m Thickness t= 0.22 m
DENSITY(CAPACITY) γ1= 14 kN/m3
o
ANGLE OF NATURE REPOSE ρ1 = 35
γ= 16 kN/m3
CONCRETE GRADE: C30 Tensile strength design value ft= 1.43 N/mm2
REINFORCEMENT: HRB335 fy= 300 N/mm2
elasticity coefficient: Ec= 30000 N/mm2
elasticity coefficient: Es= 200000 N/mm2
2. SILO PRESSURE
Bulk density of clinker: γ= 16 kN/m3
Internal friction angle ¢ = 33 o
o
Angle of wall friction: δ=1.0 * ¢= 33
Wall friction: μ=tanδ= 0.649
Silo inside diameter: D = 12 m
Silo inside perimeter π* D= 37.699 m
Hydraulic radius: ρ = D/4 = 3 m
Pressure coefficient: k=(1-sin¢)/(1+sin¢)= 0.295
Height of cone gravity: H = (h2)/3 = 1.400 m
Static lateral pressures along depth: Py = γρ(1-e-μkz/ρ)/μ
Thus,static lateral pressures along depth: Stress of reinf.:≤ 230 N/mm2And<0.55fy
Dia.
Req'd hoop Spacing of Actual hoop
of steel
NO. steel Ast steel bar steel Ast' fvt (des) fvt' (st)
bar
(mm2) (mm) (mm2)
(mm)
4. Temperature reinforcement :
Materials characteristic :