You are on page 1of 1

TYPICAL CROSS SECTION OF STORM WATER DRAIN

CLEAR INTERNAL DIMENSIONS- 1200mm x 600mm


TYPE- VEHICULAR- CAST IN SITU
RTL EL
1500
8 @ 250c/c DISTRIBUTION CUSHION UPTO 4000

.
400mm 400mm
TOP SLAB TO BE CAST SEPARATELY

16 @ 130 c/c BOTTOM FACE


10 @ 120c/c 10 @ 120c/c a) ALL DIMENSIONS ARE IN mm
O.F O.F
GRADE OF
8 @ 250c/c DISTRIBUTION B.F

8 @ 250 c/c DISTRIBUTION B.F


1200 b) M40
CONCRETE
GRADE OF Fe500
c)
REINFORCEMENT
COVER TO 40mm
10 @300 c/c I.F d)

600

925
REINFORCEMENT
e) THICKNESS
TOP SLAB 150mm
SIDE WALLS 150mm
BOTTOM RAFT 175mm
f) LAP LENGTH 50 X BAR DIA.

350
10 @300 c/c + 16@300 c/c I.F g) LEGENDS
10@ 120c/c O.F + 10@ 240c/c O.F
I.F INSIDE FACE
+
O.F OUTSIDE FACE
B.F BOTH FACE
S.F SIDE FACE

75 mm THK. PCC DWG.NO. 040/SWD/V/01-02


8 @200 c/c DISTRIBUTION REVISION - R1