Professional Documents
Culture Documents
This guide
This guide
is a quick
is a quick
reference
reference
for the
forFlexi Multiradio
the Flexi Antenna
Multiradio System
Antenna FAGFinstallation.
System and FAGP
installation.
The Flexi Multiradio Antenna System can be mounted on the wall or on the pole.
This quick
The Flexi Multiradio Antenna guide
System is forand
FAGF basic wall
the FAGP can and pole installation
be mounted .
on the wall or on the pole.
Check Prepare
Prepare
thethe
installation
installation Ground the Active Antenna
Check the the site
delivery
Preparing
Preparing for Grounding
Contents
Contentsof
1 delivery
of 3 Active
2 Antenna 3
delivery installation principles
for installation
Site bag
Site bag content
content
Fixing thetools
strainand
relief Installation
Installation material
Clearances and fixing points Wall
4
Fixing the strain relief installation
Pole
5 installation
Adjusting
6 mechanical tilt
Cabling
7 Cabling
Power cabling
EAC cabling
Antenna cabling
RET/AISG cabling
Optical cabling
Installing Flexi
9 System External
OVP
10 Commissioning
11 Installation
check list
-2-
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Solutions and Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Solutions and Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Solutions and Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Solutions and Networks and the customer. However,
Nokia Solutions and Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions.
Nokia Solutions and Networks will, if deemed necessary Nokia Solutions and Networks, explain issues which
may not be covered by the document.
Nokia Solutions and Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SOLUTIONS AND NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION
OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
NSN is a trademark of Nokia Solutions and Networks. Nokia is a registered trademark of Nokia Corporation.
Other product names mentioned in this document may be trademarks of their respective owners,
and they are mentioned for identification purposes only.
NOTICE:
Incorrect cables and seals may not provide secured weather protection. In outdoor
installations, including the outdoor cabinet, use only tested IP65 class outdoor cables
with seals provided by Nokia Solutions and Networks. This is also recommended
for indoor installations.
NOTICE:
Electrostatic discharge (ESD) may damage the modules. Wear an ESD wrist strap or
use a corresponding method when handling the modules.
-3-
1 Contents of delivery
Delivery Contents Versions Codes
Active Antenna delivery Active Antenna FAGF AAS 2100/1800 FAGF 472559A
Active Antenna FAGP 2100act/800-900pas FAGP 472584A
Optional items
Pole mounting kit delivery Flexi Pole Kit, B (kit contains 2 pole kit assemblies) FPKB 472804A
Transmission cable delivery Flexi system fibre SM 4m FSOR 472607A
Flexi RRH System Fibre MM A 10m FSOH 472067A
Flexi RRH System Fibre SM L 50m FSOL 472069A
Flexi RRH System Fibre SM O 110m FSOO 472070A
Flexi RRH System Fibre SM Q 200m FSOQ 472068A
MM fiber, bended ends 2m FSFL 472894A
MM fiber, straights ends, 4m FSOD 472842A
Flexi RRH System Fibre MM A 10m FSOA 472066A
Flexi RRH System Fiber MM B 20m FSOB 472134A
Flexi RRH System Fiber MM C 30m FSOC 472135A
WiMAX Optical Cable LC 50m FYTF 471964A
Flexi RRH System Fiber MM E 75m FSOE 472136A
MM fiber, 90-90, OM3, 100m FSFM 472844A
MM fiber, 90-90, OM3, 200m FSFN 472845A
DC cable multibeam-open, 2m FPCC 472823A
Flexi Power DC Cable 4M FPTA 472246A
EAC Cable FTSI 472578A
EAC cable HDMI-D37 15m FSAH 472839A
Flexi RRH System Fiber MM E 75m FSOE 472136A
MM fiber, 90-90, OM3, 100m FSFM 472844A
MM fiber, 90-90, OM3, 200m FSFN 472845A
Flexi RRH Optical SFP G 850nm 3G 200m MM FOSG 472063A
Flexi Optical SFP L 1310 nm 3Gb 2km SM FOSL 472807A
3
5 2 5
1
6 8
3 6
(15.75 inch)
400 mm
Ensure that the wall
(15.75 inch)
installation surface
400 mm
and selected
fasteners can
sustains the device
under the
required
circumstances. m )
0 m ch
(93.14 inch)
m ) 40 5 in
2366 mm
0 m ch .7
40 5 in (15
(62.46 inch)
1587 mm
.7
(15
m )
m ) 0 m ch
0 m ch 40 5 in
40 5 in . 7
. 7 (15
(15
~45 kg ~55 kg
~99 lb ~121 lb
(15.75 inch)
400 mm
(15.75 inch)
400 mm
185 mm 185 mm
(7.28 inch) (7.28 inch)
3 Grounding principles
1. Connect the wrist strap.
1 2. Connect the grounding
cable to the antenna module.
2 3. Fix the grounding cable
Optional grounding
using M8 or two M5 screws.
to ESD stud 3
WARNING! Risk of
electric shock.
5 Pole installation
!
1 2 55 Nm
!
!
20 Nm
! !
20 Nm
!
3 4 Lifting
point
Lifting point 5 Lifting
point
Lifting point
NOTE:
FPKB is designed for poles between 60 mm (2.4 in.) and 120 mm (4.7 in.) in diameter.
1. Install the FPKB into the antenna’s lower bracket and tighten screws to 20 Nm (14.75 ft lb).
2. Install the second FPKB onto the pole and tighten M12 screws to 55 Nm (40.56 ft lb).
3. Lift the antenna, using the lifting point.
4. Lift the unit to pole and tighten it to the upper bracket.
5. Secure the mounting bracket upper/lower screw to 20 Nm and FPKB mounting kit screws with 55 Nm.
NOTICE: Excessive stress on the strain relief may cause it to break.
NOTICE: Do not release the lifting rope until the unit is safely secured.
Check list
The antenna is secured in position and is pointing in the appropriate direction.
-6-
6 Adjusting mechanical tilt
NOTE: Mechanical tilt adjustment can be performed only after antenna installation.
1. Loose the locking’s screws from both sides of the 4. Tight the locking screws to the slot on both sides of the bracket.
bracket. 5. Once the antenna is in its desired tilt angle, tighten the bolts on
2. Loosen the bolts on each side of the lower bracket. the upper and lower brackets to 20 Nm (14.75 ft lb).
3. Loosen the bolts on each side of the upper bracket.
NOTICE: Do not release the lifting rope until the unit is safely secured.
Upper bracket
1 2
11
5
NOTE: Only
the hex-head
screw can be
released.
!
20 Nm
!
Lower bracket
3 4
5
11
NOTE: Only
the hex-head
screw can be
released.
Lower bracket
-7-
7 Cabling
Power cabling
3 4 5
3. Wrap an extra tape around the exposed wires in order not to break the IP NOTICE: The IP boot edge must be smooth. No
boot. crack in the edge is allowed, as it breaks the
4. Insert the taped end of the DC feeder cable into the IP boot. boot's IP protection.
5. Remove the tape before you connect the wires to the screw terminal.
6 7 8
Check list
Power cable is properly installed.
-8 -
7 Cabling (continued)
EAC cabling
3 4
1 2
power cable
1. Remove the EAC connector seal from the module. 3. Expand the cable clamp.
2. Slide off the IP boot and push the connector seal firmly in 4. Place EAC cable into the cable clamp and close it.
place. 5. Fix the cable with a screw to the strain relief.
Check list
Antenna cabling
1 2 3
4
!
25 Nm
!
Check list
Antenna cable is properly installed.
-9-
7 Cabling (continued)
RET/AISG cabling
1 2 3
1 2
5
6 7
power cable
optical cables
grounding cable
1. Remove the connector seal from optical connector. 5. Push the connector seal firmly in place.
2. Push the optical transceiver into the connector. 6. Pull the cable through the optical cable clamp and
3. Pull back the connector seal to uncover the connector. tighten it.
4. Remove the protective plug, clean the connector end face, 7. Fix the clamp to the strain relief with the screw.
and connect the cable.
NOTICE: Overbending the optical cables can detach or damage the connectors.
Do not bend the optical cables beyond the maximum radius of 70 mm (2.75 in.).
Check list
Optical cable has been cleaned and properly installed.
Double check that the correct optical interface is installed.
-10-
8 Installing FPAC (optional step)
1 2
3 4
NOTE: Before installing the DC cable prepare it according the instructions provided in section 7.
Check list
FPAC is properly installed.
-11-
9 Installing FSES (optional step)
1 2 3
1. Mount FSES to FPIA. 2. Thread the straining strap. 3. Install the FPIA to the pole
10 Commissioning
11 Installation checklist