Professional Documents
Culture Documents
API 570 - Close Book Mockup Exam Final
API 570 - Close Book Mockup Exam Final
2. For a P11 material piping under repair, what sort of heat treatment is
required?
3. For a 16mm thick 30ӯ pipe repair work what is the correct heat treatment
1. The inspector
2. The piping engineer
3. The owner/user
4. The Fabricator
1. The weld should be parallel to the longitudinal axis of the bend and
the root should be in the convex
2. The weld should be perpendicular to the longitudinal axis of the
bend and the root should be in the convex
3. The weld should be parallel to the longitudinal axis of the bend and
the root should be in the concave
4. The weld should be perpendicular to the longitudinal axis of the
bend and the root should be in the concave
(API-570-Mockup-CB) 2/18
1. It is to be rejected
2. It acceptable provided it meets the density and sensitivity
limitations of ASME Sec.V Article.II
3. It is depends on the project spec
4. A Level-III shall be consulted
8. A pipe support moved outs of its base and is hanging what is your
assessment as an inspector
1. < NPS 2
2. < NPS 3
3. < NPS 2 1/2
4. > NPS 2
11. A lead letter ‘B’ of ½” height and 1/16” thickness was used on a
radiographic set up what is the purpose of it.
1. A black image
2. A white image
3. A dark image
4. A gray image
13. Which one below is not a contributing factor for brittle fracture?
14. The MPI procedure should describe about which of the following?
15. The bolt hole size of a weld neck flange 12” dia 1500#
1. 51.4 mm
2. 53.84 mm
3. 53.00 mm
4. 54.98 mm
16. A flange material of A182 Gr.F1 of what class will be required for
operating pressure of 1000 psi @ 400°F
1. 600 #
2. 900#
3. 300 #
4. 400 #
17. What would be the maximum operating pressure of a flange A182 Gr.F2
400# at 500°F
1. 590 psi
2. 570 psi
3. 516 psi
4. 885 psi
(API-570-Mockup-CB) 4/18
19. Out of long and short-term corrosion rate which one will be used for
MAWP calculation
20. While doing welding repair on a system in service the inspector should
access the system in accordance to
1. API publ.2201
2. API RP 574
3. API RP 578
4. ASME Sec. VIII Division-1
21. What is the up-stream limit of an injection point for regular inspection
22. What are the minimum marking shall be made of a buried piping leak
temporarily clamped area
23. The soil closed potential survey is being carried out for a non-cathodically
protected system is
1. Once in 5 years
2. Once in 3 years
3. Half of the remaining life
4. Once in 6 months
(API-570-Mockup-CB) 5/18
24. A buried piping with sleeve is excavated for inspection,
26. Which of the valve in a piping system is not suitable for pigging
1. Gate valve
2. Ball valve
3. Globe valve
4. Slide valve
1. 2000F
2. 2000C
3. 930F
4. 3000F
1. Valve
2. elbows
3. flanges
4. Blind flanges
30. Which of the test method is not a material identification test method
1. visual
2. radiographic
3. internal visual
4. ultrasonic
34. A 20” dia pipe has internal leakage near the flange to pipe weld. During
shut down what sort of inspection will be planned for this
35.. Localized loss in thickness exhibiting directional pattern can occur due to
1. atmospheric corrosion
2. microbiologically induced corrosion
3. erosion - corrosion
4. sulphidation
36. To detect interior surface breaking planar flaws the owner/user should
specify
1. Approved inspector
2. Industry qualified UT inspector
3. API qualified inspector
4. Any examiner qualified to carry out NDT
(API-570-Mockup-CB) 7/18
37. Out of the patch mentioned which one is not allowed on a 12” piping
repair
38. Out of the repair carried out in the piping system which one is considered
to be a permanent one
1. 10 minutes
2. 3 minutes
3. 30 minutes
4. 1 hour
45. When a buried piping with a design pressure of 100 psi is under leak test
at 125 psi. The initial 4 hrs. of testing shows a slight pressure drop and
has been adjusted. The second 4 hrs recorded a drop in pressure
of 5 psi, the test
1. It is not acceptable
2. Check for leak along the pipe work
3. The test is acceptable
4. To be consulted with a inspector
46. The pressure gauge used on a sensitive leak test shall be of range….wrt
test pressure
1. 2 to 2.5
2. 2
3. 1.5 to 4.0
4. 1.5 to 3.0
48. A new branch is welded over an existing piping system it should meet
……
49. A radiographic testing for the welder qualification is not allowed for which
process
1. Piping Engineer
2. Inspector
3. Repair Organisation
4. Operating Personnel
(API-570-Mockup-CB) 10/18
53. Which of the following are some of the mandatory requirements for re-
rating a piping system?
1. Normally required
2. Not required at all
3. Depend on opinion of piping inspector
4. Only “1” and “3” above
55. Name a part of a piping system that thickness measurements are not
normally routinely taken:
1. Elbows
2. Expansion loops
3. Tees
4. Valves
57. Which of the following are areas on piping systems which are susceptible
to CUI during the range of 25°F to 250°F:
58. Listed below are several examples of piping system. Which is class I
piping for flammable fluids?
59. Which of the following documents referenced in API 570 addresses hot
tapping?
1. API 2201
2. API 574
3. ASME B 31 G
4. None of the above
61. For which of the following, the approval from piping engineer is not
mandatory:
63. For a project involving piping welding at site by 10 welders, (with only
one qualified welder) procedure and 9 welders were to be qualified. In this
case, identify correct statement from the following:
1. Ductility of weld
2. Strength of weld
3. Soundness of weld
4. Both soundness and ductility of weld
66. According to ASME Sec. IX, a welder for SMAW can be qualified by
following minimum tests:
1. True
2. False
3. Depends on company policy
4. Depends on client of the company
70. When dial-type indicating and recording pressure gauges are used to
monitor leak testing, the maximum gauge range shall not exceed which
multiple of the expected test pressure?
1. 1 ½ times
2. 2 ½ times
3. 3 times
4. 4 times
71. A radiographic technique in which radiation passed through two walls and
both the walls are viewed on the same radiograph (double wall, double
image – ellipse) the limitation for the outside diameter is:
1. 3-1/2”
2. 2”
3. 4”
4. Any diameter possible
1. 5.0 years
2. 4.5 years
3. 6.0 years
4. None of above
(API-570-Mockup-CB) 14/18
73. Common locations which are susceptible to CUI on the insulated piping
are:
1. All penetrations or breaches in the insulation jacketing
such as vents, drains, piping hangers
2. Termination of insulation at flanges
3. All insulated bends and elbows
4. ‘1’ and ‘2’ above
74. The accuracy of a piece of magnetizing equipment that is equipped with
an ammeter shall be verified:
1. Each year
2. Each two years
3. When possible
4. Every 6 months
1. Radiography
2. Ultrasonic
3. Hardness survey
4. None of above
80. In visual testing for qualifying the procedure, a defect of which minimum
width shall be used:
1. 1/16”
2. 1/8”
3. 1/32”
4. None of the above
1. Annually
2. Six monthly
3. Once in 3 years
4. None of the above
82. The pressure gauges for leak testing shall be calibrated as an ASME Sec.
V requirement, at least:
83. It is decided to carryout a surface NDT for austenitic S.S. pipe welds.
Choose the best combination.
86. When a pressure test is not necessary or practical, what shall be utilised
in lieu of a pressure test?
1. PMI Testing
2. Non-destructive examination
3. Vacuum visual examination
4. Hammer Testing
1. Sub-surface cracks
2. Surface cracks
3. Both ‘1’ and ‘2’
4. For none of ‘1’ and ‘2’
88. The pipe welding test position in which the pipe is horizontal and rotated
so that welding takes place at or near the top is designated as?
1. 2G
2. 5G
3. 3G
4. 1G
90. For thickness measurement of pipes NPS 1 and smaller, NDT technique
employed would be:
1. Ultrasonic technique
2. Radiographic profile technique
3. Anyone is okay.
4. None are okay.
(API-570-Mockup-CB) 17/18
91. API 578 requires at least _________ electrodes to be PMI tested from
each box.
1. one
2. two
3. minimum 10%
4. all
92. Which of the following make pipe system most susceptible to CUI?
93. Freeze damage can occur in case of which of the following fluids:
1. Water only
2. Oil only
3. Water and aqueous solutions
4. None of the above
94. For calculating MAWP of Piping Circuit which is put in service the wall
thickness used in computations is:
95. When checking austentic materials for cracks using PT methods only
liquid penetrants:
96. As per API 570 for bolted flanged joints, bolts and nuts are considered as
acceptably engaged if the lack of complete engagement is:
98. For a typical “injection point pipe circuit” starts upstream of injection point
from a distance of
99. For MT examination by Prod technique the spacing between prods shall
be between:
1. 4 inches to 12 inches
2. 4 inches to 10 inches
3. 3 inches to 10 inches
4. 3 inches to 8 inches
-0-0-0-0-0-
API 570 Authorized Piping Inspector Preparatory Program
MASTER
Q A Q A Q A Q A
1. 3 26. 3 51. 4 76. 1
2. 3 27. 1 52. 2 77. 1
3. 2 28. 1 53. 4 78. 4
4. 3 29. 4 54. 1 79. 3
5. 1 30. 3 55. 4 80. 3
6. 2 31. 1 56. 2 81. 1
7. 3 32. 3 57. 4 82. 2
8. 2 33. 1 58. 1 83. 1
9. 4 34. 1 59. 1 84. 1
10. 2 35. 3 60. 2 85. 2
11. 3 36. 2 61. 1 86. 2
12. 2 37. 1 62. 3 87. 2
13. 4 38. 1 63. 2 88. 4
14. 1 39. 3 64. 4 89. 2
15. 2 40. 2 65. 2 90. 2
16. 1 41. 1 66. 2 91. 1
17. 4 42. 1 67. 4 92. 4
18. 1 43. 2 68. 2 93. 3
19. 3 44. 1 69. 1 94. 3
20. 1 45. 3 70. 4 95. 4
21. 1 46. 3 71. 1 96. 2
22. 3 47. 1 72. 1 97. 4
23. 1 48. 1 73. 4 98. 1
24. 2 49. 2 74. 1 99. 4
25. 1check 50. 4 75. 4 100. 2
-0-0-0-0-0-