SEM - 3036E
Piping Design Manual
RACK PIPING
REV. : 5
DATE : 1998. 9. 28
CONTENTS
Page
1. GENERAL
3. RACK ARRANGEMENT
6. LOADING DATA
1. GENERAL
1.1 Purpose
This manual shall be applied to all jobs executed by SECL unless otherwise specially required
from vendor or licensor.
The following piping shall be laid out on the pipe rack with 25% space for future piping.
2.1.5 Catwalk
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 2 OF 44
3. RACK ARRANGEMENT
Above- (1) Discharge piping and vibration piping (1) In-out piping for raw material and
ground of reciprocating compressor products
(2) Storage and in-out piping with dike
(3) Large size fluid piping
Rack arrangement is generally subject to the location of process lines such as raw material piping
and products piping and the location of utility lines that enter and leave the unit boundary.
(1) Installation and maintenance of equipment and transportation of equipment and materials.
(2) Piping between each unit shall be as short as possible.
(3) Length and number of rack shall be the minimum.
(1) Dead end yard lines enter and (2) Straight through yard, line can
leave one end the rack. enter and leave both ends of the
rack.
(3) L-shaped yard lines can enter (4) T-shaped rack piping can enter
and leave north and east of and leave on three sides of the
the rack. rack.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 4 OF 44
(5) U-shaped yard lines can enter (6) Combination of I and T shaped
and leave all four sides of the rack.
rack.
4. RACK HEIGHT
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 5 OF 44
(1) The height of top surface of the lowest rack beam shall be subject to the following:
(Unit : mm)
Classification H1 Remarks
Main road crossing at inside of B.L. 4500 Clearance for big vehicle : 3500
2) Decisions shall be made after examining mutual relation between the equipments, and problems
on taking-in, operation and maintenance of equipment.
3) For the minimum height mentioned on above item No.1), consider the highest point of road
paving.
4) According to the road traffic act enforcement ordinance, all facilities such as a bridge,
signs above the road shall have min. 4.5m headroom from lowest point of the road.
5) When the equipment such as exchanger is located under the rack, its highest part shall be
the base of rack height after examining each exchanger as shown on the below.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 6 OF 44
Difference of height (H) for each level of rack shall be 1000mm, 1500mm, 2000mm as the
standard.
(Unit : mm)
Elbow Dimension 228.6 304.8 381.0 457.2 533.4 609.6 685.8 762.0
Nominal Pipe Size 24B 26B 28B 30B 32B 34B 36B 40B
Elbow Dimension 914.4 990.6 1066.8 1143.0 1219.2 1295.4 1371.4 1524.0
Type Ⅰ (90°) - - - - - - - -
Type Ⅲ (30°) 557 625 673 721 762 817 865 961
(Note) : H ≥ 2h
For elbow 90°, 45°and 30°→ Consider it as a long radius elbow and
calculate the height.
(1) Large size pipes (14" and larger) shall be arranged close to the column in order to
decrease the bending moment of beam.
(2) The utility piping shall be laid on the middle of the rack If the rack has a
single level and these piping shall be laid on the upper level if the rack has two levels.
Piping in the rack shall be arranged according to the "Table of arrangement classification"
on the next page.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 8 OF 44
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 9 OF 44
Vibration piping ○
High and low pressure steam piping ○
Condensate piping ○
Boiler feed water piping ○ ○ ○
U
T
I Hose station piping (water, air, N₂, etc.) ○ ○
L
I Plant air piping ○ ○
T
Y Cooling water header piping for pump ○
(3) The end of utility header piping shall be arranged as same as the following figures.
(Note) : (*) For the class of 900LB and over, the piping similar to the above types shall
be avoided.
(4) Piping with corrosive fluids shall not be installed above the cable duct.
(5) For reciprocating compressor discharge piping, pressure drop valve and drain piping to be
installed on the pipe rack, thorough consideration shall be given to the vibration
protection.
(6) Piping at B.L. connection point shall be arranged through sufficient coordibation with the
client and the relevant contractor, discussing the piping arrangement and the anchor
locations.
(7) Platform or walkway with ladder shall be installed on the rack where frequent operation
and/or maintenance of valves are required. A ladder hall be installed with a cage .
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 11 OF 44
(8) When necessary to install an expansion loop on the condensate line, do it horizontally to
prevent water hammering. But, do as follows if horizontal loop is impossible.
Make lines into a group and install a large size piping and high temperature piping to
the edge of the rack.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 12 OF 44
(10) Grounding is necessary on the piping where static electricity is expected to occur.
[Reference]
┌ 1st Petroleum (crude oil, gasoline, solvent, naphtha, tar, light oil, etc.)
│
Petroleum ┼ 2nd Petroleum (kerosene, light oil, diesel oil, xylene, etc.)
│
└ 3rd Petroleum (heavy oil, lube oil, tars such as creosote oil)
Ether, carbon bisulfide, collodion, acetone, nitric acid ester, formic acid ester,
pyridine, chloro-benzol, animals and plants oils, etc.
(*) Pneumatic conveying piping for powders susceptible to the disaster due to static
electricity and non-conductive powders (synthetic resin, wheat powder, etc.).
Insulated pipe
L=30+ Insulation thickness
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 13 OF 44
Farication and
Sus Teminal attachment of lug
by piping contractor
③ For piping on the rack, it is recommended to consider the rack column connected
to grounding main line at every 18m as same as the piping.
(11) Harzadous gas piping shall be installed on the upper rack and it shall be away from high
temperature piping.
(12) Install steel shoes on the hot-insulated piping (except for protector) and the cold-
insulated piping operating at over 0℃.
(13) Install support with cradle (rest type or whole circumference type) for cold-insulated
piping operating at 0℃ and under.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 14 OF 44
(14) Install support with saddle for thin pipes or large size pipes (D/t > 95) to minimize
local stress. (But, as above support type is not necessary when the distance of rack
column is short, its application shall be determined after preliminary examination.)
(16) Oxygen piping shall not be arranged adjacent to the electrical duct.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 15 OF 44
(1) Piping spacing on the rack shall be decided in accordance with "Drafting Data C-9
(SEM-3007)".
(Thorough consideration shall be given to the maintenance, hot insulation, cold insulation
and lateral movement by thermal expansion.)
(2) If special valve and instrument are installed on the rack, make decision on the width
considering the space of operation and maintenance.
(3) For the area where there are orifice piping, provide space for installing orifice
considering the orientation of differential pressure taps.
* Type "B-1" and "C-1" shall be generally installed as the following figure.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 16 OF 44
B ≥ Bo + F
Bo = { (P1 + P2)) + CE } × (1 + F)
B : Rack width
Bo : Calculated rack width
P1, P2 : Pipe spacing (as per "Drafting Data C-9" in SEM-3007)
CE : Electric cable duct
α : 0.1 ~ 0.15
F : For future extension (α included)
6. LOADING DATE
Refer to line
Liquid load for hydrostatic pressure test. Vertical schedule.
Sustained
load
(Live load) Snow load (The difference of snowfall
depending on the region shall be considered Vertical
in making decision)
1) Liquid piping
a) Insulated and subject to hydrostatic pressure test
Load = piping weight + insulation weight + contents weight
b) Un-insulated and subject to hydrostatic pressure test
Load = piping weight + contents weight
c) Insulated and subject to pneumatic pressure test
Load = piping weight + insulation weight + contents weight
d) Un-insulated and subject to pneumatic pressure test
Load = piping weight + contents weight
2) Gas piping
a) Insulated and subject to hydrostatic pressure test
Load = piping weight + insulation weight + water weight
b) Un-insulated and subject to hydrostatic pressure test
Load = piping weight + water weight
c) Insulated and subject to pneumatic pressure test
Load = piping weight + insulation weight
d) Un-insulated and subject to pneumatic pressure test
Load = piping weight
Note : 1) For pipe and insulation weight, refer to weight table of paragraph 6.4.
2) For instrument duct and electric duct, refer to the following table.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 18 OF 44
Width (W) × Height (H) Weight (kg/m) Width (W) × Height (H) Weight (kg/m)
(1) The stress limit on anchors and guides is 1410 kg/㎠ Max.
(2) Force limit on anchors and guides is 1000 kg Max. unbalanced force including friction
loads.
Example 1 :
Example 2 :
Notes : 1. For friction loads, we can manually calculate them getting the unit weights from
the table in para.6.4.
2. For thermal loads, we can manually calculate them using the data and nomographs.
But computer program is very well prepared and is it faster, accurate to use
computer for total unbalanced force at the anchor point.
Example 3 :
△
▲ ▲
6.4 Weight Table for pipe and Thermal Insulation (for reference)
6.4.1 Calcium silicate hot-insulation (ρ = 0.22 g/㎤)
1/2 21.7 - 0.8 1.1 2.5 3.9 5.0 6.9 10.9 15.6 17.8 23.8 30.6 38.4 46.9
3/4 27.2 - 0.9 1.2 2.7 4.1 5.3 7.3 11.3 16.2 18.4 24.5 31.4 39.2 47.9
1 34.0 0.6 1.0 1.3 2.9 4.4 5.7 7.7 11.8 16.8 19.1 25.3 32.3 40.3 49.1
1½ 48.6 1.4 1.3 1.6 3.4 5.1 6.4 8.6 13.0 18.3 20.6 27.0 34.4 42.5 51.6
2 60.5 2.2 1.5 1.9 3.8 5.6 7.0 9.4 13.9 19.4 21.8 28.5 36.0 44.4 53.7
2½ 76.3 3.6 1.8 2.2 4.4 6.3 7.8 10.3 15.2 20.9 23.5 30.4 38.2 46.9 56.4
3 89.1 5.1 2.0 2.5 4.8 6.9 8.5 11.1 16.2 22.2 24.8 31.9 40.0 48.8 58.6
4 114.3 8.7 2.4 3.0 5.7 8.1 9.8 12.7 18.2 24.6 27.4 35.0 43.4 52.8 62.9
6 165.2 18.9 3.3 4.0 7.4 10.3 12.5 15.9 22.3 29.5 32.7 41.1 50.5 60.7 71.7
8 216.2 32.9 4.3 5.1 9.2 12.6 15.1 19.1 26.3 34.5 38.0 47.3 57.5 68.6 80.6
10 267.4 50.7 5.1 6.2 11.0 14.3 17.7 22.2 30.4 39.4 43.3 53.5 64.6 76.6 89.4
12 318.5 72.9 5.9 7.2 12.7 17.2 20.4 25.4 34.5 44.4 48.6 59.7 71.7 84.5 98.2
14 355.6 92.7 6.6 8.0 14.0 18.9 22.3 27.7 37.4 50.2 52.4 64.2 76.8 90.3 104.6
16 406.4 122.1 7.5 9.0 15.8 21.2 25.0 30.9 41.4 52.9 57.7 70.3 83.8 98.2 113.4
18 457.2 155.6 8.3 10.1 17.5 23.5 27.6 34.0 45.5 57.8 62.9 76.5 90.8 106.1 122.2
20 508.0 193.1 9.2 11.2 19.3 25.7 30.2 37.2 49.5 62.7 68.2 82.6 97.9 114.0 131.0
22 558.8 234.7 10.1 12.2 21.0 28.0 32.9 40.4 53.6 67.6 73.5 88.8 104.9 121.9 139.8
24 609.6 279.6 11.0 13.3 22.8 30.3 35.5 43.5 57.6 72.5 78.7 94.9 111.9 129.8 148.5
26 660.4 330.0 11.8 14.3 24.5 32.6 38.1 46.7 61.6 77.4 84.0 101.0 118.9 137.7 157.3
28 711.2 383.8 12.7 15.4 26.3 34.9 40.8 52.9 65.7 82.4 89.3 107.2 126.0 145.6 166.1
30 762.0 440.6 13.6 16.4 28.1 37.2 43.4 53.0 69.7 87.3 94.5 113.3 133.0 153.5 174.9
32 812.8 502.4 14.5 17.5 29.9 39.4 46.0 56.2 73.7 92.2 99.8 119.5 140.0 161.4 183.6
34 863.6 568.2 15.4 18.5 31.6 41.8 48.7 59.3 77.8 97.1 105.1 125.6 147.0 169.3 192.4
36 914.4 638.1 16.2 19.6 33.3 44.0 51.3 62.2 81.8 102.0 110.3 131.8 154.0 177.2 201.2
40 1016.0 782.8 18.0 21.7 36.8 48.6 56.6 68.8 89.9 111.9 120.9 144.1 168.1 193.0 218.7
42 1066.8 840.0 18.9 22.7 38.6 50.8 59.2 72.0 93.9 116.8 126.1 150.2 175.1 200.9 227.5
44 1117.6 944.7 19.7 23.8 40.3 53.1 61.8 75.1 98.0 121.7 131.4 156.3 182.1 208.8 236.3
48 1219.2 1125.0 21.5 25.9 43.9 57.7 67.1 81.4 106.0 131.5 141.9 168.6 196.2 224.6 253.9
54 1371.6 1426.0 24.1 29.1 49.1 64.5 75.0 90.9 118.2 146.3 157.7 187.1 217.2 248.3 280.2
60 1524.0 1763.0 26.8 32.2 54.4 71.4 82.9 100.4 130.3 161.0 173.5 205.5 238.3 272.0 306.5
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 22 OF 44
1/2 21.7 - 0.7 1.0 2.3 3.5 4.6 6.3 9.9 14.2 16.2 21.6 27.9 34.9 42.7
3/4 27.2 - 0.8 1.1 2.4 3.8 4.8 6.6 10.3 14.7 16.7 22.2 28.6 35.7 43.5
1 34.0 0.6 0.9 1.2 2.6 4.0 5.1 7.0 10.8 15.3 17.3 23.0 29.4 36.6 44.6
1½ 48.6 1.4 1.2 1.5 3.1 4.6 5.8 7.8 11.8 16.6 18.7 24.6 31.2 38.7 46.9
2 60.5 2.2 1.3 1.7 3.5 5.1 6.4 8.5 12.7 17.6 19.8 25.9 32.7 40.4 48.8
2½ 76.3 3.6 1.6 2.0 4.0 5.8 7.1 9.4 13.8 19.0 21.3 27.6 34.7 42.6 51.3
3 89.1 5.1 1.8 2.3 4.4 6.3 7.7 10.2 14.7 20.2 22.6 29.0 36.5 44.4 53.4
4 114.3 8.7 2.2 2.7 5.2 7.3 8.9 11.6 16.6 22.4 24.9 31.8 39.5 48.0 57.2
6 165.2 18.9 3.0 3.7 6.8 9.4 11.3 14.4 20.2 26.8 29.7 37.4 45.9 55.2 65.2
8 216.2 32.9 3.8 4.6 8.4 11.5 13.7 17.3 23.9 31.3 34.5 43.0 52.3 62.4 73.2
10 267.4 50.7 4.6 5.6 10.0 13.6 16.1 20.2 27.6 35.8 39.3 48.6 58.7 69.6 81.3
12 318.5 72.9 5.4 6.6 11.6 15.7 18.5 23.1 31.3 40.3 44.2 54.3 65.2 76.8 89.3
14 355.6 92.7 6.0 7.3 12.7 17.2 20.3 25.2 34.0 43.6 47.7 58.3 69.8 82.1 95.1
16 406.4 122.1 6.8 8.2 14.3 19.3 22.7 28.1 37.7 48.1 52.4 63.9 76.2 89.3 103.1
18 457.2 155.6 7.6 9.2 15.9 21.3 25.1 30.9 41.3 52.5 57.2 69.5 82.6 96.4 111.1
20 508.0 193.1 8.4 10.1 17.5 23.4 27.5 33.8 45.0 57.0 62.0 75.1 89.0 103.6 119.1
22 558.8 234.7 9.2 11.1 19.1 25.5 30.0 36.7 48.7 61.5 66.8 80.7 95.4 110.8 127.0
24 609.6 279.6 10.0 12.1 20.7 27.6 32.3 39.6 52.4 65.9 71.6 86.3 101.7 118.0 136.6
26 660.4 330.0 10.8 13.0 22.3 29.6 34.7 42.4 56.0 70.4 76.4 91.9 108.1 125.2 143.0
28 711.2 383.8 11.6 14.0 23.9 31.7 37.0 45.3 59.7 74.9 81.2 97.4 118.3 132.4 151.0
30 762.0 440.6 12.4 14.9 25.5 33.8 39.4 48.2 63.4 79.3 86.0 103.0 120.9 139.5 159.0
32 812.8 502.4 13.2 15.9 27.1 35.8 41.8 51.1 67.0 83.8 90.7 108.6 127.3 146.7 166.9
34 863.6 568.2 14.0 16.8 28.7 37.9 44.2 53.9 70.7 88.3 95.5 114.2 133.7 153.9 174.9
36 914.4 638.1 14.8 17.8 30.3 40.0 46.6 56.8 74.4 92.7 100.3 119.8 140.0 161.1 182.9
40 1016.0 782.8 16.4 19.7 33.5 44.1 51.4 62.5 81.7 101.7 109.9 131.0 152.8 175.4 198.9
42 1066.8 840.0 17.1 20.7 35.1 46.2 53.8 65.4 85.4 106.2 114.7 136.5 159.2 182.6 206.8
44 1117.6 944.7 17.9 21.6 36.7 47.9 56.2 68.3 88.3 110.6 119.5 142.1 165.6 189.8 214.8
48 1219.2 1125.0 19.5 23.5 39.9 52.4 61.0 74.0 96.4 119.6 129.0 153.3 178.3 204.2 230.8
54 1371.6 1426.0 21.9 26.4 44.7 58.7 68.2 82.7 107.6 133.0 143.4 170.1 197.5 225.7 254.7
60 1524.0 1763.0 24.3 29.3 49.4 64.9 75.4 91.3 118.4 146.4 157.8 186.8 216.6 247.3 278.7
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 23 OF 44
1/2 21.7 - 0.1 0.2 0.3 0.4 0.6 0.8 1.1 1.7 2.5 2.8 3.8 4.9 6.1 7.5
3/4 27.2 - 0.1 0.2 0.3 0.4 0.7 0.8 1.2 1.8 2.6 2.9 3.9 5.0 6.2 7.6
1 34.0 0.6 0.2 0.2 0.3 0.5 0.7 0.9 1.2 1.9 2.7 3.0 4.0 5.1 6.4 7.8
1½ 48.6 1.4 0.2 0.3 0.4 0.5 0.8 1.0 1.4 2.1 2.9 3.3 4.3 5.5 6.8 8.2
2 60.5 2.2 0.2 0.3 0.4 0.6 0.9 1.1 1.5 2.2 3.1 3.5 4.5 5.7 7.1 8.5
2½ 76.3 3.6 0.3 0.4 0.5 0.7 1.0 1.2 1.6 2.4 3.3 3.7 4.8 6.1 7.5 9.0
3 89.1 5.1 0.3 0.4 0.6 0.8 1.1 1.4 1.8 2.6 3.5 3.9 5.1 6.4 7.8 9.3
4 114.3 8.7 0.4 0.5 0.7 0.9 1.3 1.6 2.0 2.9 3.9 4.4 5.6 6.9 8.4 10.0
6 165.2 18.9 0.5 0.6 0.9 1.2 1.6 2.0 2.5 3.5 4.7 5.2 6.5 8.0 9.7 11.4
8 216.2 32.9 0.7 0.8 1.1 1.5 2.0 2.4 3.0 4.2 5.5 6.0 7.5 9.1 10.9 12.8
10 267.4 50.7 0.8 1.0 1.4 1.8 2.3 2.8 3.5 4.8 6.3 6.9 8.5 10.3 12.2 14.2
12 318.5 72.9 0.9 1.1 1.6 2.0 2.7 3.2 4.0 5.5 7.1 7.7 9.5 11.4 13.4 15.6
14 355.6 92.7 1.0 1.3 1.7 2.2 3.0 3.5 4.4 6.0 8.0 8.3 10.2 12.2 14.4 16.6
16 406.4 122.1 1.2 1.4 2.0 2.5 3.4 4.0 4.9 6.6 8.4 9.2 11.2 13.3 15.6 18.0
18 457.2 155.6 1.3 1.6 2.2 2.8 3.7 4.4 5.4 7.2 9.2 10.0 12.1 14.4 16.9 19.4
20 508.0 193.1 1.5 1.8 2.4 3.1 4.1 4.8 5.9 7.9 10.0 10.9 13.1 15.6 18.1 20.8
22 558.8 234.7 1.6 1.9 2.6 3.3 4.5 5.2 6.4 8.5 10.8 11.7 14.1 16.7 19.4 22.2
24 609.6 279.6 1.8 2.1 2.9 3.6 4.8 5.6 6.9 9.2 11.5 12.5 15.1 17.8 20.7 23.6
26 660.4 330.0 1.9 2.3 3.1 3.9 5.2 6.1 7.4 9.8 12.3 13.4 16.1 18.9 21.9 25.0
28 711.2 383.8 2.0 2.5 3.3 4.2 5.6 6.5 8.4 10.5 13.1 14.2 17.1 20.0 23.2 26.4
30 762.0 440.6 2.2 2.6 3.5 4.5 5.9 6.9 8.4 11.1 13.9 15.0 18.0 21.2 24.4 27.8
32 812.8 502.4 2.3 2.8 3.8 4.8 6.3 7.3 8.9 11.7 14.7 15.9 19.0 22.3 25.7 29.2
34 863.6 568.2 2.5 2.9 4.2 5.0 6.7 7.7 9.4 12.4 15.4 16.7 20.0 23.4 26.9 30.6
36 914.4 638.1 2.6 3.1 4.2 5.3 7.0 8.2 9.9 13.0 16.2 17.5 20.1 24.5 28.2 32.0
40 1016.0 782.8 2.9 3.5 4.6 5.9 7.7 9.0 10.9 14.3 17.8 19.2 22.9 26.7 30.7 34.8
42 1066.8 840.0 3.0 3.6 4.9 6.1 8.1 9.4 11.5 14.9 18.6 20.1 23.9 27.9 32.0 36.2
44 1117.6 944.7 3.1 3.8 5.1 6.4 8.4 9.8 11.9 15.6 19.4 20.9 24.9 29.0 33.2 37.6
48 1219.2 1125.0 3.4 4.1 5.5 7.0 9.2 10.7 13.0 16.8 20.9 22.6 26.8 31.2 35.7 40.4
54 1371.6 1426.0 3.8 4.6 6.2 7.8 10.3 11.9 14.5 18.8 23.3 25.1 29.8 34.6 39.5 44.6
60 1524.0 1763.0 4.3 5.1 6.9 8.7 11.4 13.2 16.0 20.7 25.6 27.6 32.7 37.9 43.3 47.8
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 24 OF 44
1/2 21.7 - 0.6 0.8 1.2 1.8 2.8 3.6 5.1 7.9 8.2 8.9 12.6 12.2 16.7
3/4 27.2 - 0.7 0.9 1.4 1.9 3.0 3.9 5.3 8.2 8.8 9.5 13.0 13.2 17.3
1 34.0 0.6 0.7 1.0 1.5 2.1 3.2 4.1 5.6 8.6 9.1 9.8 13.6 13.6 18.1
1½ 48.6 1.4 0.9 1.2 1.8 2.5 3.7 4.7 6.3 9.5 10.1 10.9 14.9 15.0 19.7
2 60.5 2.2 1.1 1.7 2.0 2.8 4.1 5.1 6.8 10.1 10.9 11.8 14.2 16.2 18.8
2½ 76.3 3.6 1.3 1.6 2.3 3.2 4.6 5.7 7.5 11.1 12.1 13.0 17.4 17.8 22.9
3 89.1 5.1 1.4 1.8 2.6 3.5 5.0 6.2 8.1 12.1 13.0 14.0 18.8 19.1 24.8
4 114.3 8.7 1.8 2.2 3.1 4.1 5.9 7.1 9.2 13.3 14.7 15.9 20.7 21.6 27.2
6 165.2 18.9 2.4 2.9 4.1 5.4 7.5 9.1 11.5 16.2 18.3 19.7 25.2 26.8 32.9
8 216.2 32.9 3.0 3.7 5.2 6.7 9.2 11.0 13.9 19.2 21.9 23.5 29.7 31.9 38.7
10 267.4 50.7 3.7 4.5 6.2 8.0 10.9 12.9 16.2 22.1 25.5 27.4 34.2 37.0 44.5
12 318.5 72.9 4.3 5.3 7.2 9.3 12.5 14.8 18.5 25.1 29.1 31.3 38.7 42.2 50.3
14 355.6 92.7 4.8 5.8 8.0 10.2 13.7 15.9 20.2 27.2 31.7 34.0 41.9 45.9 54.5
16 406.4 122.1 5.4 6.6 9.0 11.5 15.4 18.1 22.5 30.1 35.3 37.9 46.4 51.0 60.2
18 457.2 155.6 6.1 7.3 10.0 12.7 17.1 20.1 24.8 33.1 38.9 41.7 50.9 56.1 66.0
20 508.0 193.1 6.7 8.1 11.0 14.0 18.7 22.0 27.1 36.0 42.4 45.5 55.3 61.2 71.7
22 558.8 234.7 7.3 8.9 12.0 15.3 20.4 23.9 29.4 38.9 46.0 49.4 59.8 66.3 77.4
24 609.6 279.6 8.0 9.6 13.0 16.6 22.0 25.8 31.6 41.9 49.6 53.2 64.2 74.2 83.2
26 660.4 330.0 8.6 10.4 14.9 17.9 23.4 27.7 33.9 44.8 53.2 57.0 68.7 76.5 88.9
28 711.2 383.8 9.3 11.2 15.1 19.1 25.4 29.6 36.2 47.8 56.7 60.9 73.2 81.7 94.7
30 762.0 440.6 9.9 11.9 16.1 20.4 27.0 31.6 38.5 50.7 60.3 64.7 77.7 86.8 100.4
32 812.8 502.4 10.5 12.7 17.1 21.7 28.7 33.5 40.8 53.6 63.9 68.5 82.1 91.9 106.2
34 863.6 568.2 11.2 13.5 18.2 23.1 30.3 35.4 43.1 56.6 67.5 72.4 86.6 97.0 111.9
36 914.4 638.1 11.8 14.2 19.2 24.2 32.0 37.3 45.4 59.5 74.2 80.3 95.8 112.0 128.9
40 1016.0 782.8 13.1 15.8 21.2 26.8 35.3 41.1 50.0 65.4 81.3 87.9 104.8 122.2 140.4
42 1066.8 840.0 13.7 16.5 22.3 28.1 37.0 43.0 52.4 68.3 84.9 91.7 109.2 127.4 146.1
44 1117.6 944.7 14.4 17.3 23.3 29.3 38.6 45.0 54.6 71.3 88.5 95.6 113.7 132.5 151.8
48 1219.2 1125.0 15.6 18.8 25.3 31.9 42.0 48.8 59.2 77.1 95.6 103.2 122.6 142.7 164.3
54 1371.6 1426.0 17.6 21.1 28.4 35.7 46.9 54.5 66.1 85.9 106.4 114.7 136.0 158.0 180.6
60 1524.0 1763.0 19.5 23.4 31.4 39.6 51.9 60.3 73.0 94.7 117.8 127.0 149.5 174.3 197.8
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 25 OF 44
7. Expansion Loops
Loops designed according to these charts will be stressed to the allowable limit for A-53 Gr.B
seamless Pipe. or equal, with LR elbows of the same thicikness as straight pipe.
Do not use for weaker material, or extraploate beyond the range of the charts.
With long expansion lenghts and nested loops, investigate pipe movements.
If thrusts are critical, consult stress section.
The distance between the guides. "G" is a minimum.
If there is not sufficient room to accommodate the depth of loop shown on the chart, then some
relief can be found by widening the loop. This effect is small, and can only be counted on within
the following limits:
If it is desirable from a layout point of view, W may always be safely increased without any
decrease on H, providing that:
W ≥ ½ anchor distance
G ≥ 2W
For loops in which there is a vertical offset:
(Unit : mm)
(2) For conditions of rack span, decision shall be made considering the following:
Decision on what the minimum pipe diameter of rack piping shall be and what the allowable
bending of the minimum pipe diameter shall be.
Fluid weight of pipe, pipe weight, valve weight and insulation weight.
Relation with piping whose support span is short, such as copper, many kinds of plastic and
glass lining pipes.
If deflection of pipe is too great, drainage is not good, fluid which is in the slurry state
of high boiling point produces crystals and condensible vapor such as steam and dowtherm
vapor causes water hammering.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 42 OF 44
(4) For rack column around structure or building, use columns of structure or building column
together if possible, and allow easy access from the ground.
(8) If there is expansion loop, or a lot of branch piping is expected to the unit on the rack,
indicate it on the structure planning drawing of the below form.
(9) Basically, ladders shall be installed at every 40∼60m of the rack considering the relation of
each area and cat way.
(10) Install bracing on the rack within the range that it does not interfere with pipe run,
operation and maintenance. (One bracing shall be installed at least every six span of racks.)
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 43 OF 44
2) 2 level
① Normal structure (number of beam is 2 : one on the upper and the other on the lower) :
L = 6 m
(12) The maximum deflection of rack beam shall be generally 1/300 against 2 span.
SEM - 3036E
DESIGN MANUAL
REV. : 5
RACK PIPING
DATE : 1998. 9.28 PAGE 44 OF 44